Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clock synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

Clock synchronization experiments using OMEGA transmissions

The OMEGA transmissions from North Dakota on 13.10 and 12.85 kHz were monitored at several sites using a recently developed OMEGA timing receiver specifically designed for this purpose. The experiments were conducted at Goddard Space Flight Center, Greenbelt, Maryland; U.S. Naval Observatory, Washington, D.C.; and at the NASA tracking station, Rosman, North Carolina. Results show that cycle identification of the two carrier frequencies was made at each test site, thus, coarse time (76 microseconds) from the OMEGA transmitted signals to within the ambiguity period of each OMEGA frequency was extracted. The fine time determination, which was extracted from the phase difference between the received OMEGA signals and locally generated signals, was about + or - 2 microseconds for daytime reception and about + or - 5 microseconds for nighttime reception.

Chi, A. R.↗

Source structure errors in the synchronization of clocks by radio interferometry

Radio interferometry has the potential of synchronizing clocks across intercontinental distances with accuracies better than one nanosecond. One of the potential error sources in such determinations is the spatial structure of the natural radio sources that provide the reference signals. Due to their extent, the effective position of these sources can vary as a function of the length and orientation of the baseline vector joining the two antennas. If they are not corrected, such variations can lead to errors in clock synchronization. The theory of structure corrections is presented and specific examples are given to illustrate the nature and size of the effect.

Thomas, J. B.↗

Precise time transfer using MKIII VLBI technology

It is well known that Very Long Baseline Interferometry (VLBI) is capable of precise time synchronization at subnanosecond levels. This paper deals with a demonstration of clock synchronization using the MKIII VBLI system. The results are compared with clock synchronization by traveling cesium clocks and GPS. The comparison agrees within the errors of the portable clocks (+ 5 ns) and GPS(+ or - 30 ns) systems. The MKIII technology appears to be capable of clock synchronization at subnanosecond levels and appears to be very good benchmark system against which future time synchronization systems can be evaluated.

Johnston, K. J.↗

Synchronizing computer clocks using a local area network

Researchers completed the first tests of a method to synchronize the clocks of networked computers to the National Institute of Standards and Technology (NIST) time scale. The method uses a server computer to disseminate the time to other clients on the same local-area network. The server is synchronized to NIST using the ACTS protocol over a dial-up telephone line. The software in both the server and the parameters of this model are used to adjust the time of the local clock and the interval between calibration requests in a statistically optimum way. The algorithm maximizes the time between calibrations while at the same time keeping the time of the local clock correct within a specific tolerance. The method can be extended to synchronize computers linked over wide-area networks, and an experiment to test the performance of the algorithms over such networks is being planned.

Levine, Judah↗

A Self-Stabilizing Synchronization Protocol for Arbitrary Digraphs

This paper presents a self-stabilizing distributed clock synchronization protocol in the absence of faults in the system. It is focused on the distributed clock synchronization of an arbitrary, non-partitioned digraph ranging from fully connected to 1-connected networks of nodes while allowing for differences in the network elements. This protocol does not rely on assumptions about the initial state of the system, other than the presence of at least one node, and no central clock or a centrally generated signal, pulse, or message is used. Nodes are anonymous, i.e., they do not have unique identities. There is no theoretical limit on the maximum number of participating nodes. The only constraint on the behavior of the node is that the interactions with other nodes are restricted to defined links and interfaces. This protocol deterministically converges within a time bound that is a linear function of the self-stabilization period. We present an outline of a deductive proof of the correctness of the protocol. A bounded model of the protocol was mechanically verified for a variety of topologies. Results of the mechanical proof of the correctness of the protocol are provided. The model checking results have verified the correctness of the protocol as they apply to the networks with unidirectional and bidirectional links. In addition, the results confirm the claims of determinism and linear convergence. As a result, we conjecture that the protocol solves the general case of this problem. We also present several variations of the protocol and discuss that this synchronization protocol is indeed an emergent system.

Malekpour, Mahyar R.↗

Time synchronization via lunar radar.

The advent of round-trip radar measurements has permitted the determination of the ranges to the nearby planets with greater precision than was previously possible. When the distances to the planets are known with high precision, the propagation delay for electromagnetic waves reflected by the planets may be calculated and used to synchronize remotely located clocks. Details basic to the operation of a lunar radar indicate a capability for clock synchronization to plus or minus 20 microsec. One of the design goals for this system was to achieve a simple semiautomatic receiver for remotely located tracking stations. The lunar radar system is in operational use for deep space tracking at Jet Propulsion Laboratory and synchronizes five world-wide tracking stations with a master clock at Goldstone, Calif. Computers are programmed to correct the Goldstone transmissions for transit time delay and Doppler shifts so as to be received on time at the tracking stations; this dictates that only one station can be synchronized at a given time period and that the moon must be simultaneously visible to both the transmitter and receiver for a minimum time of 10 min.-

Higa, W. H.↗

Synchronization of clocks by very-long-baseline interferometry

Two hydrogen-maser clocks, one at Haystack Observatory and one at the National Radio Astronomy Observatory, were synchronized by means of observations of several extragalactic radio sources on March 28, and again on September 23, 1977. Observations were made sequentially in eight 360-kHz bands distributed between about 8.4 and 8.5 GHz with spacings designed to enable the group-delay difference between the signals received at the two observatories from a given source to be estimated unambiguously, within an uncertainty of less than 1 ns set by receiver noise. The epoch and the rate differences between the observatories' clocks for each experiment were estimated by analysis of observations that spanned several hours. The application of corrections for the contributions to the delays of the antennas, feeds, receiver systems, and recorders yielded absolute determinations of the clock epoch differences. During each experiment, portable cesium clocks were flown from the U.S. Naval Observatory to the observatories and back. The traveling-clock data, analyzed in each case after the VLBI synchronization had been completed, confirmed the VLBI results to within 18 and 14 ns for the first and second experiments, respectively.

Clark, T. A.↗

Fast Synchronization With Burst-Mode Digital Signals

Oscillator quickly synchronized with data clock. Sampling clock synchronized with sinusoid by feedback technique. Signal is measure of phase-error angle theta and generated digitally by technique related to calculation of theta from periodic samples of sinusoid.

Lee, Lin-Nan↗

Scalable polylithic on-package integratable apparatus and method

Described is an apparatus which comprises: a first die including: a processing core; a crossbar switch coupled to the processing core; and a first edge interface coupled to the crossbar switch; and a second die including: a first edge interface positioned at a periphery of the second die and coupled to the first edge interface of the first die, wherein the first edge interface of the first die and the first edge interface of the second die are positioned across each other; a clock synchronization circuit coupled to the second edge interface; and a memory interface coupled to the clock synchronization circuit.

Khare, Surhud↗

Integrated Formal Analysis of Timed-Triggered Ethernet

We present new results related to the verification of the Timed-Triggered Ethernet (TTE) clock synchronization protocol. This work extends previous verification of TTE based on model checking. We identify a suboptimal design choice in a compression function used in clock synchronization, and propose an improvement. We compare the original design and the improved definition using the SAL model checker.

Dutertre, Bruno↗

Constellation Program Electrical Ground Support Equipment Research and Development

At the Kennedy Space Center, I engaged in the research and development of electrical ground support equipment for NASA's Constellation Program. Timing characteristics playa crucial role in ground support communications. Latency and jitter are two problems that must be understood so that communications are timely and consistent within the Kennedy Ground Control System (KGCS). I conducted latency and jitter tests using Alien-Bradley programmable logic controllers (PLCs) so that these two intrinsic network properties can be reduced. Time stamping and clock synchronization also play significant roles in launch processing and operations. Using RSLogix 5000 project files and Wireshark network protocol analyzing software, I verified master/slave PLC Ethernet module clock synchronization, master/slave IEEE 1588 communications, and time stamping capabilities. All of the timing and synchronization test results are useful in assessing the current KGCS operational level and determining improvements for the future.

McCoy, Keegan S.↗