PASP, a high voltage array/plasma interaction experiment

The author discusses the photovoltaic array space power (PASP) experiment, which is designed to obtain data on the interaction between high-voltage photovoltaic arrays and the polar, low-earth plasma environment. Up to six small test arrays (three each of planar and concentrator designs) can be voltage biased over a range of +/- 500 V. During the bias voltage sequence, the array current leakage is measured and array arc events are monitored. If any arcing occurs the arc characteristics will be measured by a transient pulse monitor. An emitter is included to allow voltage bias to be applied to a plasma-charged or uncharged spacecraft. Similarly, the frames of the concentrator arrays can be left floating or can be tied to the negative array terminal. An environmental data scan is made before each bias voltage sequence. This scan collects information on the plasma, array-current-versus-voltage curves, and neutral particle partial pressure. The requirement for high voltages created problems which were met by circuit isolation and logical fault protection.

Burger, Dale R.↗

Advanced Stirling Convertor Control Unit Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

Future NASA missions could include establishing Lunar or Martian base camps, exploring Jupiters moons and travelling beyond where generating power from sunlight may be limited. Radioisotope Power Systems (RPS) provide a dependable power source for missions where inadequate sunlight or operational requirements make other power systems impractical. Over the past decade, NASA Glenn Research Center (GRC) has been supporting the development of RPSs. The Advanced Stirling Radioisotope Generator (ASRG) utilized a pair of Advanced Stirling Convertors (ASC). While flight development of the ASRG has been cancelled, much of the technology and hardware continued development and testing to guide future activities. Specifically, a controller for the convertor(s) is an integral part of a Stirling-based RPS. For the ASRG design, the controller maintains stable operation of the convertors, regulates the alternating current produced by the linear alternator of the convertor, provides a specified direct current output voltage for the spacecraft, synchronizes the piston motion of the two convertors in order to minimize vibration as well as manage and maintain operation with a stable piston amplitude and hot end temperature. It not only provides power to the spacecraft but also must regulate convertor operation to avoid damage to internal components and maintain safe thermal conditions after fueling. Lockheed Martin Coherent Technologies has designed, developed and tested an Engineering Development Unit (EDU) Advanced Stirling Convertor Control Unit (ACU) to support this effort. GRC used the ACU EDU as part of its non-nuclear representation of a RPS which also consists of a pair of Dual Advanced Stirling Convertor Simulator (DASCS), and associated support equipment to perform a test in the Radioisotope Power Systems System Integration Laboratory (RSIL). The RSIL was designed and built to evaluate hardware utilizing RPS technology. The RSIL provides insight into the electrical interactions between as many as 3 radioisotope power generators, associated control strategies, and typical electric system loads. The first phase of testing included a DASCS which was developed by Johns Hopkins UniversityApplied Physics Laboratory and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. Testing included the following spacecraft electrical energy storage configurations: capacitive, battery, and supercapacitor. Testing of the DASCS and ACU in each energy storage configuration included simulation of a typical mission profile, and transient voltage and current data during load turn-on/turn-off. Testing for these devices also included the initiation of several system faults such as short circuits, electrical bus over-voltage, under-voltage and a dead bus recovery to restore normal power operations. The goal of this testing was to verify operation of the ACU(s) when connected to a spacecraft electrical bus.

Dugala, Gina M.↗

Advanced Stirling Convertor Control Unit Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

Future NASA missions could include long-duration flyby, orbital, lander, or rover applications where generating power from sunlight may be limited. Radioisotope power systems (RPSs) provide a dependable power source for missions where inadequate sunlight or operational requirements make other power systems impractical. Over the past 16 years, NASA Glenn Research Center has been supporting the development of RPSs. The advanced Stirling radioisotope generator (ASRG) utilized a pair of advanced Stirling convertors (ASCs). Although flight development of the ASRG has been canceled, much of the technology and hardware continued development and testing to guide future activities. Specifically, a controller for the convertor(s) is an integral part of a Stirling-based RPS. For the ASRG design, the controller maintains stable operation of the convertors, regulates the alternating current produced by the linear alternator of the convertor, provides a specified direct-current output voltage for the spacecraft, and synchronizes the piston motion of the two convertors to minimize vibration as well as manage and maintain operation with a stable piston amplitude and hot-end temperature. It not only provides power to the spacecraft but also must regulate convertor operation to avoid damage to internal components and maintain safe thermal conditions after fueling. Lockheed Martin Coherent Technologies, Inc., has designed, developed, and tested an ASC control unit engineering development unit (ACU EDU) to support this effort. GRC used the ACU EDU as part of its nonnuclear representation of a RPS that also consists of a Dual advanced Stirling convertor simulator (DASCS), and associated support equipment to perform a test in the Radioisotope Power Systems System Integration Laboratory (RSIL). The RSIL was designed and built with flexibility to evaluate hardware utilizing RPS technology. The RSIL provides insight into the electrical interactions between as many as three radioisotope power generators, associated control strategies, and typical electric system loads. The first phase of testing included a DASCS that was developed by Johns Hopkins University Applied Physics Laboratory and simulates the operation and electrical behavior of a pair of ASCs in real time via a combination of hardware and software. Testing included the following spacecraft electrical energy storage configurations: capacitor, battery, and supercapacitor. Testing of the DASCS and ACU in each energy storage configuration included simulation of a typical mission profile and transient voltage and current data during load turnon and turnoff. Testing for these devices also included the initiation of several system faults such as short circuits, electrical bus overvoltage, undervoltage, and a "dead bus" recovery to restore normal power operations. The goal of this testing was to verify operation of the ACU(s) when connected to a spacecraft electrical bus. The results of these tests are presented here.

General↗

Hard Fault Protection for a Silicon Carbide-Based Aerospace Motor Drive

Due to increasingly high DC link voltages and further advancements in the current density of silicon carbide (SiC) MOSFETs, it has become evident that conventional IGBT protection methods are not sufficient to protect these devices from overcurrent during low-inductance fault events. The use of an air core Rogowski coil topology was explored to see if it could mitigate these hard fault events. The design of this circuit resulted in safe shutdown of a low impedance phase-tophase fault, tested up to DC link voltages of 1 kV.

High Voltage↗

Detectors Ensure Function, Safety of Aircraft Wiring

Pedro Medelius waited patiently in his lab at Kennedy Space Center. He had just received word that a colleague was bringing over a cable from a Space Shuttle solid rocket booster to test Medelius new invention. Medelius was calm until his colleague arrived, with about 30 other people. "Talk about testing under pressure," says Medelius. "There were people there from the Navy, the Air Force, and the Federal Aviation Administration." After the group s arrival, Medelius took a deep breath and connected his Standing Wave Reflectometer (SWR) to the cable. He wiggled the cable around, and the display showed a fault (a short or open circuit in wire) about an inch and a half inside the connector on the cable. His colleague questioned the results, because he had already checked that area on the cable. Medelius used the SWR to check again but got the same result. "That is when we took the cable apart and looked inside," Medelius says. "Lo and behold, that was exactly where the fault was." The impetus for Medelius new wire inspection technology came about in 1999 when one of the space shuttles lost power due to a fault somewhere in its more than 200 miles of electrical wiring. "The backup circuit was activated and prevented a major dysfunction, but nevertheless, there was a problem with the wiring," Medelius describes. Even though technicians used a device called a multimeter to measure the electrical current to find which wire had a fault, it could not pinpoint exactly where on the wire the fault was located. For that, technicians had to visually inspect the wire. "Sometimes they would have to remove the whole wire assembly and visually inspect every single wire. It was a very tedious operation because the wires are behind cabinets. They go all over the place in the shuttle," says Medelius. "NASA needed an instrument capable of telling them exactly where the faults were occurring." To meet NASA s needs for a highly precise device to inspect electrical power bundles, wires, and connectors, Medelius devised the SWR. "It came down to what was affected when a wire is short circuited or opened," he says. "We worked out a few equations based on physical principles." The SWR proved very sensitive, and the technology was patented.

Source record↗

Detection of CMOS bridging faults using minimal stuck-at fault test sets

The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.

Ijaz, Nabeel↗

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor↗

Large transient fault current test of an electrical roll ring

The space station uses precision rotary gimbals to provide for sun tracking of its photoelectric arrays. Electrical power, command signals and data are transferred across the gimbals by roll rings. Roll rings have been shown to be capable of highly efficient electrical transmission and long life, through tests conducted at the NASA Lewis Research Center and Honeywell's Satellite and Space Systems Division in Phoenix, AZ. Large potential fault currents inherent to the power system's DC distribution architecture, have brought about the need to evaluate the effects of large transient fault currents on roll rings. A test recently conducted at Lewis subjected a roll ring to a simulated worst case space station electrical fault. The system model used to obtain the fault profile is described, along with details of the reduced order circuit that was used to simulate the fault. Test results comparing roll ring performance before and after the fault are also presented.

Yenni, Edward J.↗

Large transient fault current test of an electrical roll ring

The Space Station Freedom uses precision rotary gimbals to provide for sun tracking of its photoelectric arrays. Electrical power, command signals, and data are transferred across the gimbals by roll rings. Roll rings have been shown to be capable of highly efficient electrical transmission and long life, through tests conducted at the NASA Lewis Research Center and Honeywell's Satellite and Space Systems Division in Phoenix, AZ. Large potential fault currents inherent to the power system's DC distribution architecture have brought about the need to evaluate the effects of large transient fault currents on roll rings. A test recently conducted at Lewis subjected a roll ring to a simulated worst case space station electrical fault. The system model used to obtain the fault profile is described, along with details of the reduced order circuit that was used to simulate the fault. Test results comparing roll ring performance before and after the fault are also presented.

Yenni, Edward J.↗

Fault models

A major problem in the qualification of integrated circuit cells and in the development of adequate tests for the circuits is to lack of information on the nature and density of fault models. Some of this information is being obtained from the test structures. In particular, the Pinhole Array Capacitor is providing values for the resistance of gate oxide shorts, and the Addressable Inverter Matrix is providing values for parameter distributions such as noise margins. Another CMOS fault mode, that of the open-gated transistor, is examined and the state of the transistors assessed. Preliminary results are described for a number of open-gated structures such as transistors, inverters, and NAND gates. Resistor faults are applied to various CMOS gates and the time responses are noted. The critical value for the resistive short to upset the gate response was determined.

Sayah, H. R.↗

Lithosphere-Atmosphere-Ionosphere Coupling (LAIC) Model - An Unified Concept for Earthquake Precursors Validation

The paper presents a conception of complex multidisciplinary approach to the problem of clarification the nature of short-term earthquake precursors observed in atmosphere, atmospheric electricity and in ionosphere and magnetosphere. Our approach is based on the most fundamental principles of tectonics giving understanding that earthquake is an ultimate result of relative movement of tectonic plates and blocks of different sizes. Different kind of gases: methane, helium, hydrogen, and carbon dioxide leaking from the crust can serve as carrier gases for radon including underwater seismically active faults. Radon action on atmospheric gases is similar to the cosmic rays effects in upper layers of atmosphere: it is the air ionization and formation by ions the nucleus of water condensation. Condensation of water vapor is accompanied by the latent heat exhalation is the main cause for observing atmospheric thermal anomalies. Formation of large ion clusters changes the conductivity of boundary layer of atmosphere and parameters of the global electric circuit over the active tectonic faults. Variations of atmospheric electricity are the main source of ionospheric anomalies over seismically active areas. Lithosphere-Atmosphere-Ionosphere Coupling (LAIC) model can explain most of these events as a synergy between different ground surface, atmosphere and ionosphere processes and anomalous variations which are usually named as short-term earthquake precursors. A newly developed approach of Interdisciplinary Space-Terrestrial Framework (ISTF) can provide also a verification of these precursory processes in seismically active regions. The main outcome of this paper is the unified concept for systematic validation of different types of earthquake precursors united by physical basis in one common theory.

Pulinets, S.↗

Fault tolerance using self-checking building-block computers

The paper attempts to define and characterize a set of VLSI (very large scale integration) building-block circuits which can be used to combine existing microprocessors and memories into a wide variety of fault-tolerant computing systems. Such VLSI circuits would transform fault-tolerant computing into an off-the-shelf technology and enable its routine use for new applications. The self-checking computer module (SCCM) is the basic component out of which fault-tolerant computer systems are constructed. Several fault-tolerant configurations of SCCM are discussed, including the standby redundant uniprocessor, the voted/hybrid uniprocessor, and the distributed computer network.

Rennels, D. A.↗

Feasibility study for a generalized gate logic software simulator

Unit-delay simulation, event driven simulation, zero-delay simulation, simulation techniques, 2-valued versus multivalued logic, network initialization, gate operations and alternate network representations, parallel versus serial mode simulation fault modelling, extension of multiprocessor systems, and simulation timing are discussed. Functional level networks, gate equivalent circuits, the prototype BDX-930 network model, fault models, identifying detected faults for BGLOSS are discussed. Preprocessor tasks, postprocessor tasks, executive tasks, and a library of bliss coded macros for GGLOSS are also discussed.

Mcgough, J. G.↗

Technique for improving solid state mosaic images

Method identifies and corrects mosaic image faults in solid state visual displays and opto-electronic presentation systems. Composite video signals containing faults due to defective sensing elements are corrected by a memory unit that contains the stored fault pattern and supplies the appropriate fault word to the blanking circuit.

Saboe, J. M.↗

Fast-acting self-healing metallic fuse.

Description of a fast-acting nonmechanical self-healing mercury fuse capable of protecting a high current circuit or device from overcurrent fault damages. Basically the self-healing fuse consists of two enclosed mercury reservoirs connected by a fine capillary tube filled with mercury that serves as the fusing element. It is pointed out that a better understanding of the energy conversion process involved in the operation of the device could help explore other device configurations (such as a tapering geometry and use of magnetic field to drive the arc into the fuse wall on inductive loads, etc.) and thus extend the range of capabilities for this type of protective device.

Schwartz, F. C.↗

Simple tool removes IC flat packs

Handtool has bifurcated handle that can be tightened so that clamping head grips pack securely. Tool easily removes hybrid integrated-ciruit flat packs from printed-wiring boards. It does not damage circuit or board; thus, board can be reused with replacement circuit, and old circuit can be analyzed for faults and, if possible, repaired.

Eggebeen, J.↗

CADAT test pattern generator

CADAT test pattern generator (TPG) aids in checkout, fault detection, and fault isolation of complex digital circuits. Time and effort of manually generating digital test patterns can be major limiting factor in effectively utilizing automatic testing. This time and effort are reduced from several months to several days by TPG.

Source record↗

The SMART MIL-STD-1553 bus adapter hardware manual

The SMART Multiplexer Interface Adapter, (SMIA) a complete system interface for message structure of the MIL-STD-1553, is described. It provides buffering and storage for transmitted and received data and handles all the necessary handshaking to interface between parallel 8-bit data bus and a MIL-STD serial bit stream. The bus adapter is configured as either a bus controller of a remote terminal interface. It is coupled directly to the multiplex bus, or stub coupled through an additional isolation transformer located at the connection point. Fault isolation resistors provide short circuit protection.

Ton, T. T.↗