Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Molecular Insight into Fluorocarbon Adsorption in Pore Expanded Metal–Organic Framework Analogs

The rapid growth in the global energy demand for space cooling requires the development of more efficient environmental chillers for which adsorption-based cooling systems can be utilized. Here, in this contribution, we explore sorbents for chiller use via a pore-engineering concept to construct analogs of the 1-dimensional pore metal–organic framework MOF-74 by using elongated organic linkers and stereochemistry control. The prepared pore-engineered MOFs show remarkable equilibrium adsorption of the selected fluorocarbon refrigerant that is translated to a modeled adsorption-based refrigeration cycle. To probe molecular level interactions at the origin of these unique adsorption properties for this series of Ni-MOFs, we combined in situ synchrotron X-ray powder diffraction, neutron powder diffraction, X-ray absorption spectroscopy, calorimetry, Fourier transform infrared techniques, and molecular simulations. Our results reveal the coordination of fluorine (of CH2F in R134a) to the nickel(II) open metal centers at low pressures for each Ni-MOF analog and provide insight into the pore filling mechanism for the full range of the adsorption isotherms. The newly designed Ni-TPM demonstrates exceptional R134a adsorption uptake compared to its parent microporous Ni-MOF-74 due to larger engineered pore size/volume. The application of this adsorption performance toward established chiller conditions yields a working capacity increase for Ni-TPM of about 400% from that of Ni-MOF-74, which combined with kinetics directly correlates to both a higher coefficient of performance and a higher average cooling capacity generated in a modeled chiller.

Zheng, Jian↗

Simulation and Experimental Study of Metal Organic Frameworks Used in Adsorption Cooling

Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years in energy storage and gas separation, yet there have been few reports for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems and is an excellent alternative in industrial environments where waste heat is available. We explored the use of MOFs that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Recent computational studies of an adsorption chiller based on MOFs suggests that a thermally-driven coefficient of performance greater than one may be possible, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Presented herein are computational and experimental results for hydrophyilic and fluorophilic MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A COMPUTATIONAL AND EXPERIMENTAL STUDY OF METAL AND COVALENT ORGANIC FRAMEWORKS USED IN ADSORPTION COOLING

Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years due to their potential applications in energy storage and gas separation. However, there have been few reports on MOFs for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems. Adsorption cooling is an excellent alternative in industrial environments where waste heat is available. Applications also include hybrid systems, refrigeration, power-plant dry cooling, cryogenics, vehicular systems and building HVAC. Adsorption based cooling and refrigeration systems have several advantages including few moving parts and negligible power consumption. Key disadvantages include large thermal mass, bulkiness, complex controls, and low COP (0.2-0.5). We explored the use of metal organic frameworks that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. An adsorption chiller based on MOFs suggests that a thermally-driven COP>1 may be possible with these materials, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. In addition, a cost model has been developed to project manufactured cost of entire systems. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Presented herein are computational and experimental results for hydrophyilic MOFs, fluorophilic MOFs and also flourophilic Covalent-organic frameworks (COFs).

adsorption↗

A Distributed Intelligent Automated Demand Response Building Management System

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaporative chilling systems and methods using a selective transfer membrane

Compact membrane evaporative chillers, methods for cooling a process fluid (e.g., air) using a compact membrane evaporative chiller, and air conditioning systems and methods that include a compact membrane evaporative chiller are disclosed herein. Compact membrane evaporative chillers as disclosed herein can advantageously reduce or eliminate power consumption needed to circulate a working fluid.

Johnson, Brian↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

Solar absorption cooling plant in Seville

A solar/gas cooling plant at the Engineering School of Seville (Spain) was tested during the period 2008-2009. The system is composed of a double-effect LiBr + water absorption chiller of 174 kW nominal cooling capacity, powered by: (1) a pressurized hot water flow delivered by mean of a 352 m{sup 2} solar field of a linear concentrating Fresnel collector and (2) a direct-fired natural gas burner. The objective of the project is to indentify design improvements for future plants and to serve as a guideline. We focused our attention on the solar collector size and dirtiness, climatology, piping heat losses, operation control and coupling between solar collector and chiller. The daily average Fresnel collector efficiency was 0.35 with a maximum of 0.4. The absorption chiller operated with a daily average coefficient of performance of 1.1-1.25, where the solar energy represented the 75% of generator's total heat input, and the solar cooling ratio (quotient between useful cooling and insolation incident on the solar field) was 0.44. (author)

14 SOLAR ENERGY↗

Solar Thermal Demonstration Project

HVAC Retrofit and Energy Efficiency Upgrades at Clark High School, Las Vegas, Nevada. The overall objectives of this project are to increase usage of alternative/renewable fuels, create a better and more reliable learning environment for the students, and reduce energy costs. Utilizing the grant resources and local bond revenues, the District proposes to reduce electricity consumption by installing within the existing limited space, one principal energy efficient 100 ton adsorption chiller working in concert with two 500 ton electric chillers. The main heating source will be primarily from low nitrogen oxide (NOX), high efficiency natural gas fired boilers. With the use of this type of chiller, the electric power and cost requirements will be greatly reduced. To provide cooling to the information technology centers and equipment rooms of the school during off-peak hours, the District will install water source heat pumps. In another measure to reduce the cooling requirements at Clark High School, the District will replace single pane glass and metal panels with Kalwall building panels. An added feature of the Kalwall system is that it will allow for natural day lighting in the student center. This system will significantly reduce thermal heat/cooling loss and control solar heat gain, thus delivering significant savings in heating ventilation and air conditioning (HVAC) costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis of absorption thermal energy storage for distributed energy systems

In recent years, distributed energy systems (DES) have attracted worldwide attention. Distributed generation unit (DG) in DES usually works under part load during night, which results in low efficiency and the waste heat of DG cannot be fully utilized. This study proposes a novel absorption thermal energy storage system together with electric energy storage for distributed energy systems. The proposed absorption thermal energy storage system which is a combination of absorption chiller and liquid storage tanks, has a higher energy storage density. During off-peak hours, the extra electricity of DG can be used by electric chillers (EC) and the extra waste heat of DG is stored by the proposed absorption thermal energy storage system. The stored thermal energy is released in peak hours to meet the cooling loads of buildings. A case study of DES in a campus under cooling-dominated climate is conducted to evaluate the performance of the proposed system. The results in a typical summer day indicate that the DG utilization rate increases from 80% to 92.9%, meanwhile the required capacities of electric chillers can be obviously reduced. The operating cost of DES also reduces by 12.9% compared with the DES without energy storage. Through appropriate operation strategy, off-the-grid operation for DES can be achieved without energy waste by applying the proposed energy storage method.

Wang, Lingshi↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Analytical Study to Use the Excess Digester Gas of Wastewater Treatment Plants

This study presents an analytical method that can be used to enhance the power production rate and the energy-saving at wastewater treatment plants. The digester used at wastewater treatment plants produces digester gas by anaerobic digestion, with which biofuel production can be achieved. Biofuels can be used to meet some of the energy requirements of the wastewater treatment facility through combined heat and power (CHP) gas engines (cogeneration). Using micro gas turbine (MGT), a CHP technology can be introduced in wastewater treatment plants (WWTPs). The combination of MGTs and absorption chillers is a promising technology as it produces electricity, heating, and cooling simultaneously. The study demonstrated how the waste heat of MGTs could be used to drive absorption chillers. In this analytical study, a detailed technical and economic analysis is provided on the trigeneration system, i.e., the integration of MGTs and absorption chillers driven by waste digester gas of the wastewater treatment plants. It can meet the heating and cooling demands of the plants, which promote the reduction of utility costs. The technology presented is also useful for other thermal energy users.

09 BIOMASS FUELS↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗