Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Retrievals of Profiles of Fine And Coarse Aerosols Using Lidar And Radiometric Space Measurements

In couple of years we expect the launch of the CALIPSO lidar spaceborne mission designed to observe aerosols and clouds. CALIPSO will collect profiles of the lidar attenuated backscattering coefficients in two spectral wavelengths (0.53 and 1.06 microns). Observations are provided along the track of the satellite around the globe from pole to pole. The attenuated backscattering coefficients are sensitive to the vertical distribution of aerosol particles, their shape and size. However the information is insufficient to be mapped into unique aerosol physical properties and vertical distribution. Infinite number of physical solutions can reconstruct the same two wavelength backscattered profile measured from space. CALIPSO will fly in formation with the Aqua satellite and the MODIS spectro-radiometer on board. Spectral radiances measured by MODIS in six channels between 0.55 and 2.13 microns simultaneously with the CALIPSO observations can constrain the solutions and resolve this ambiguity, albeit under some assumptions. In this paper we describe the inversion method and apply it to aircraft lidar and MODIS data collected over a dust storm off the coast of West Africa during the SHADE experiment. It is shown that the product of the single scattering albedo, omega, and the phase function, P, for backscattering can be retrieved from the synergism between measurements avoiding a priori hypotheses required for inverting lidar measurements alone. The resultant value of (omega)P(180 deg.) = 0.016/sr are significantly different from what is expected using Mie theory, but are in good agreement with recent results obtained from lidar observations of dust episodes. The inversion is robust in the presence of noise of 10% and 20% in the lidar signal in the 0.53 and 1.06 pm channels respectively. Calibration errors of the lidar of 5 to 10% can cause an error in optical thickness of 20 to 40% respectively in the tested cases. The lidar calibration errors cause degradation in the ability to fit the MODIS data. Therefore the MODIS measurements can be used to identify the calibration problem and correct for it. The CALIPSO-MODIS measurements of the profiles of fine and coarse aerosols, together with CALIPSO measurements of clouds vertical distribution, is expected to be critically important in understanding aerosol transport across continents and political boundaries, and to study aerosol-cloud interaction and its effect on precipitation and global forcing of climate.

Kaufman, Yoram↗

A Rotary Flow Channel for Shear Stress Sensor Calibration

A proposed shear sensor calibrator consists of a rotating wheel with the sensor mounted tangential to the rim and positioned in close proximity to the rim. The shear stress generated by the flow at the sensor position is simply tau(sub omega) = (mu)r(omega)/h, where mu is the viscosity of the ambient gas, r the wheel radius, omega the angular velocity of the wheel, and h the width of the gap between the wheel rim and the sensor. With numerical values of mu = 31 (mu)Pa s (neon at room temperature), r = 0.5 m, omega = 754 /s (7200 rpm), and h = 50.8 m, a shear stress of tau(sub omega) = 231 Pa can be generated. An analysis based on one-dimensional flow, with the flow velocity having only an angular component as a function of the axial and radial coordinates, yields corrections to the above simple formula for the curvature of the wheel, flatness of the sensor, and finite width of the wheel. It is assumed that the sensor mount contains a trough (sidewalls) to render a velocity release boundary condition at the edges of the rim. The Taylor number under maximum flow conditions is found to be 62.3, sufficiently low to obviate flow instability. The fact that the parameters entering into the evaluation of the shear stress can be measured to high accuracy with well-defined uncertainties makes the proposed calibrator suitable for a physical standard for shear stress calibration.

Zuckerwar, Allan J.↗

In-Situ Measurements of Aerosol Optical Properties using New Cavity Ring-Down and Photoacoustics Instruments and Comparison with more Traditional Techniques

Carbonaceous species (BC and OC) are responsible for most of the absorption associated with aerosol particles. The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult aerosol properties to measure. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-ARC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Aerosol absorption coefficient is also measured by a photoacoustic (PA) instrument (DRI) that was operated on an aircraft for the first time during the DOE Aerosol Intensive Operating Period (IOP). This paper will report on measurements made with this new instrument and other in-situ instruments during two field recent field studies. The first field study was an airborne cam;oaign, the DOE Aerosol Intensive Operating Period flown in May, 2003 over northern Oklahoma. One of the main purposes of the IOP was to assess our ability to measure extinction and absorption coefficient in situ. This paper compares measurements of these aerosol optical properties made by the CRD, PA, nephelometer, and Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model. The second study was conducted in the Caldecott Tunnel, a heavily-used tunnel located north of San Francisco, Ca. The aerosol sampled in this study was characterized by fresh automobile and diesel exhaust. Measurements from Cadenza and from an aethalometer are presented. The aethalometer is a filter-based photometer and the infrared channel is calibrated to produce a measure of BC mass loading.

Strawa, A. W.↗

Digital Calibration of TR Modules for Real-time Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures such as that of the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). These new instrument concepts require new methods for calibrating the multiple channels, which must be combined on-board, in real-time. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on temperature, which ignores the effects of element aging and drifts unrelated to temperature. We are developing new methods for digitally calibrating digital beamforming arrays to reduce development time, risk and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop Digital Calibration, thus tracking systematic changes regardless of temperature. The benefit of this effort is that it would enable a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined on-board, in real-time.

Real-time digital beamforming↗

Short timescale stability monitoring of GOES-16 visible channels based on daily inter-calibration events with VIIRS and MODIS

The CERES project uses geostationary (GEO) imager derived broadband fluxes to estimate the diurnal flux variations between the Terra (10:30 LT) and Aqua (1:30 LT) flux obs. The GEO derived cloud properties are utilized for narrowband to broadband and angular directional model (ADM) algorithms. The GEO imager channels are first inter-calibrated to the Aqua-MODIS C6.1 calibration reference to ensure that the retrieved clouds and fluxes will be consistent. The CERES project has a 2-month latency, all GEO, MODIS and VIIRS calibration anomalies must be identified and mitigated. Convert the monthly GEO ray-matching algorithm into a daily monitoring algorithm to catch any daily calibration anomalies.

geostationary sensor calibration↗

Calibration results for NOAA-11 AVHRR channels 1 and 2 from congruent path aircraft observations

A method for using congruent atmospheric path aircraft-satellite observations to calibrate a satellite radiometer is presented. A calibrated spectroradiometer aboard a NASA ER-2 aircraft at an altitude of 19 km above White Sands (New Mexico) was oriented to view White Sands at the overpass time of the NOAA-11 AVHRR instrument along the same view vector as the satellite instrument. The data from six flights between November 1988 and October 1990 were transformed into corresponding estimates of AVHRR channel radiance at the satellite (derived from the aircraft measurements), and average counts (from the AVHRR measurements), both averaged across the footprint of the spectroradiometer. Prelaunch measurements of the AVHRR spectral response profiles are assumed, and the radiance spectrum measured by the spectroradiometer was adjusted to satellite altitude using the LOWTRAN-7 computer code. Results show reduced gains in both channel 1 (0.65 micron) and channel 2 (0.85 micron), compared to prelaunch values, with little further reduction in gain after 200 days in orbit. Results for the gain ratio (channel 1/channel 2), which is important for the calculation of the normalized vegetation index, show constant in-orbit values 5 percent above the prelaunch value.

Abel, Peter↗

Automatic PCM guard-band selector and calibrator

Automatic method for selection of proper guard band eliminates human error and speeds up calibration process. There is also an option which allows a single channel to be calibrated, independently of other channels. Entire system is designed on 3- by 4-inch printed-circuit cards and may be used with any pulse code modulation system.

Noda, T. T.↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Signal-Conditioning Amplifier Recorders

Signal-conditioning amplifier recorders (SCAmpRs) have been proposed as a means of simplifying and upgrading the Kennedy Space Center (KSC) Ground Measurement System (GMS), which is a versatile data-acquisition system that gathers and records a variety of measurement data before and during the launch of a space shuttle. In the present version of the GMS system, signal conditioning amplifiers digitize and transmit data to a VME chassis that multiplexes up to 416 channels. The data is transmitted via a high-speed data bus to a second VME chassis where it is available for snapshots. The data is passed from the second VME chassis to a high-speed data recorder. This process is duplicated for installations at two launch pads and the Vehicle Assembly Building (VAB). Since any failure of equipment in the data path results in loss of data, much of the system is redundant. The architecture of the existing GMS limits expansion or any modification to the system to meet changing requirements because of the cost and time required. A SCAmpR-based system is much more flexible. The basis of the simplification, flexibility, and reliability is the shifting of the recording function to the individual amplifier channels. Each SCAmpR is a self-contained single channel data acquisition system, which in its current implementation, has a data storage capacity of up to 30 minutes when operating at the fastest data sampling rates. The SCAmpR channels are self-configuring and self-calibrating. Multiple SCAmpR channels are ganged on printed circuit boards and mounted in a chassis that provides power, a network hub, and Inter-Range Instrument Group (IRIG) time signals. The SCAmpR channels share nothing except physical mounting on a circuit board. All circuitry is electrically separate for each channel. All that is necessary to complete the data acquisition system is a single master computer tied to the SCAmpR channels by standard network equipment. The size of the data acquisition system dictates the requirements for the specific network equipment.

Medelius, Pedro J.↗

Automatic calibration system for pressure transducers

Fifty-channel automatic pressure transducer calibration system increases quantity and accuracy for test evaluation calibration. The pressure transducers are installed in an environmental tests chamber and manifolded to connect them to a pressure balance which is uniform.

Source record↗

Nimbus-7 Earth radiation budget calibration history. Part 2: The Earth flux channels

Nine years (November 1978 to October 1987) of Nimbus-7 Earth radiation budget (ERB) products have shown that the global annual mean emitted longwave, absorbed shortwave, and net radiation were constant to within about + 0.5 W/sq m. Further, most of the small annual variations in the emitted longwave have been shown to be real. To obtain this measurement accuracy, the wide-field-of-view (WFOV) Earth-viewing channels 12 (0.2 to over 50 micrometers), 13 (0.2 to 3.8 micrometers), and 14 (0.7 to 2.8 micrometers) have been characterized in their satellite environment to account for signal variations not considered in the prelaunch calibration equations. Calibration adjustments have been derived for (1) extraterrestrial radiation incident on the detectors, (2) long-term degradation of the sensors, and (3) thermal perturbations within the ERB instrument. The first item is important in all the channels; the second, mainly in channels 13 and 14, and the third, only in channels 13 and 14. The Sun is used as a stable calibration source to monitor the long-term degradation of the various channels. Channel 12, which is reasonably stable to both thermal perturbations and sensor degradation, is used as a reference and calibration transfer agent for the drifting sensitivities of the filtered channels 13 and 14. Redundant calibration procedures were utilized. Laboratory studies complemented analyses of the satellite data. Two nearly independent models were derived to account for the thermal perturbations in channels 13 and 14. The global annual mean terrestrial shortwave and longwave signals proved stable enough to act as secondary calibration sources. Instantaneous measurements may still, at times, be in error by as much as a few Wm(exp -2), but the long-term averages are stable to within a fraction of a Wm(exp -2).

Kyle, H. Lee↗

Radiometric calibration and processing procedure for reflective bands on LANDSAT-4 protoflight Thematic Mapper

The radiometric subsystem of NASA's LANDSAT-4 Thematic Mapper (TM) sensor is described. Special emphasis is placed on the internal calibrator (IC) pulse shapes and timing cycle. The procedures for the absolute radiometric calibration of the TM channels with a 122-centimeter integrating sphere and the transfer of radiometric calibration from the channels to the IC are reviewed. The use of the IC to calibrate TM data in the ground processing system consists of pulse integration, pulse averaging, IC state identification, linear regression analysis, and histogram equalization. An overview of the SCROUNGE-era (before August 1983) method is presented. Procedural differences between SCROUNGE and the TIPS-era (after July 1983) and the implications of these differences are discussed.

Barker, J. L.↗

Development of a calibration workstation for SIR-C

The paper describes the status of a comprehensive synthetic aperture radar (SAR) software package developed specifically to aid the calibration of a multifrequency and multipolarization radar like the Shuttle Imaging Radar, SIR-C. The primary data types processed are engineering telemetry, point targets (corner reflectors and polarimetric active radar calibrators), distributed targets (clutter), tone-generators, and ground receivers. The parameters derived to aid the calibration of the production processor include measurements of relative radiometric channel to channel imbalance, absolute calibration constants, antenna pattern corrections, noise levels, polarimetric cross-talk, and geometric offsets. The software reports standard performance measurements such as resolution, peak and integrated sidelobes, radiometric response accuracy, and geometrical distortions such as scale errors, position bias and standard deviation, and image skew. Furthermore, the inclusion of software to allow updates of the shuttle-state vector (position and velocity) is considered.

Madsen, S. N.↗

Intercalibration of Meteorological Satellite Imagers Using VIRS, ATSR-2 and MODIS

Global retrievals of surface, cloud and radiative properties from geostationary (GEO) and low-Earth-orbit (LEO) meteorological satellites require accurate calibration of their imagers. An accurate and consistent calibration increases the reliability and effectiveness of long-term monitoring of climate changes. More emphasis has been placed on calibrating the thermal infrared (IR) channel. The lack of on-board calibration in the visible (VIS) channel has prompted efforts to characterize the degradation of the VIS sensor using vicarious post-launch calibration techniques that measure bright stable desert targets from space and aircraft or using satellite-to-satellite normalizations. While such inter-calibrations are valuable and widely used, the lack of a well-characterized calibration reference source and the lengthy time delay between updates have minimized their effectiveness in climate monitoring. To address these shortcomings, this paper examines the use of research satellite imagers to provide stable calibration references for the visible (VIS, approximately 0.65 micrometers) channels and develops a method for rapid intercalibration of existing satellites. Calibration coefficients are determined for the Geostationary Operational Environmental Satellites (GOES-8 to GOES-10), Geostationary Meteorological Satellite (GMS-5), Meteosat-7, and the NOAA-14 Advanced Very High Resolution Radiometer (AVHRR). As a reference calibration source, this technique uses the self-calibrating sensors on the Tropical Rainfall Measuring Mission (TRMM) Visible Infrared Radiometers (VIRS) or the ERS-2 Along Track Scanning Radiometer (ATSR-2). GOES-8 is calibrated with VIRS and then its calibration is transferred to other GEO or LEO satellites. The absolute accuracy of this technique relies on the assumption that the on-board calibration is stable and well maintained. Minnis et al. assessed the VIRS calibration using comparisons with other self-calibrated satellite sensors including the broadband Clouds and Earth's Radiant Energy System (CERES) scanners, the ERS-2 Along Track Scanning Radiometer (ATSR-2), and the Terra Moderate-resolution Imaging Spectrometer (MODIS). Thus, the VIRS data can be confidently used as the initial reference source.

Nguyen, Louis↗

Phase calibration of polarimetric radar images

The problem of phase calibration between polarization channels of an imaging radar is studied. The causes of various types of phase errors due to the radar system architecture and system imperfections are examined. A simple model is introduced to explain the spatial variation in phase error as being due to a displacement between the phase centers of the vertical and horizontal antennas. It is also shown that channel leakage can cause a spatial variation in phase error. Phase calibration using both point and distributed ground targets is discussed and a method for calibrating phase using only distributed target is verified, subject to certain constraints. Experimental measurements using the NADC/ERIM P-3 synthetic-aperture radar (SAR) system and NASA/JPL DC-8 SAR, which operates at C-, L-, and P-bands, are presented. Both of these systems are multifrequency, polarimetric, airborne, SAR systems.

Sheen, Dan R.↗