At least 91 records · Page 5

Comparison of photovoltaic cell temperatures in modules operating with exposed and enclosed back surfaces

Four different photovoltaic module designs were tested to determine the cell temperature of each design. The cell temperatures were compared to those obtained on identical design, using the same nominal operating cell temperature (NOCT) concept. The results showed that the NOCT procedure does not apply to the enclosed configurations due to continuous transient conditions. The enclosed modules had higher cell temperatures than the open modules, and insulated modules higher than the uninsulated. The severest performance loss - when translated from cell temperatures - 17.5 % for one enclosed, insulated module as a compared to that module mounted openly.

Namkoong, D.↗

PV Lifetime Project - 2025 NLR Annual Report

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light and elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions. Overall annual degradation rates are as follows: our first modules to be deployed (Jinko, Trina, QCells) have annual median degradation rate between -0.4%/yr and -0.5%/yr mainly concentrated in the first year. Mission Solar, LG and Panasonic modules are all displaying modest degradation, better than -0.3% / year. Indeed, Mission Solar fielded modules degraded less than their control modules which remain indoors and un-exposed. This is also true for the LONGi monofacial modules, which had some field degradation, but not as much as the degradation of the indoor control modules. The LONGi bifacial modules on the other hand have degraded more in the field than their monofacial counterparts, although still a modest amount (-0.4 %/yr). Of the four newest module types in the study, only one has had better than average degradation. REC360NP2 (N-type TOPCon) had a slight performance increase over the first year and a half of field deployment. For the other three new module types (plus one older module type), degradation was more rapid. In our study of 16 module types, four have demonstrated degradation faster than -1%/yr: two N-type Heterojunction, one PERC bifacial and one PERC shingled module. The two heterojunction modules in our study are degrading the most rapidly. Sunpreme n-HIT bifacial modules are showing a loss rate around -1.5%/yr, for over -10% total to date. This is largely attributed to loss in front-side Isc. This is distinct from the REC 405AA-Pure modules which have degraded -6.8% in only a year and a half, for an annualized decline of -3.9 %/yr. For this module type, the decline is roughly half in Voc, with the remaining split between FF and Isc. Of the remaining two module types, Prism Solar PERC bifacial has declined -5% total since 2019, although this loss appears to have stabilized in the most recent measurement. The Solaria PowerX-400R Shingled module type has also lost around -3.2% in the first 1.5 years of field deployment. It remains to be seen if these losses will continue with time.

14 SOLAR ENERGY↗

Characterization of Field Exposed Thin Film Modules: Preprint

Test arrays of thin film modules have been deployed at the Solar Energy Centre near New Delhi, India since 2002-2003. Performances of these arrays were reported by O.S. Sastry [1]. This paper reports on NREL efforts to support SEC by performing detailed characterization of selected modules from the array. Modules were selected to demonstrate both average and worst case power loss over the 8 yearsof outdoor exposure. The modules characterized included CdTe, CIS and three different types of a-Si. All but one of the a-Si types were glass-glass construction. None of the modules had edge seals. Detailed results of these tests are presented along with our conclusions about the causes of the power loss for each technology.

14 SOLAR ENERGY↗

Uncertainty Evaluation of Measurements with Pyranometers and Pyrheliometers

Evaluating photovoltaic (PV) cells, modules, arrays and systems performance of solar energy relies on accurate measurement of the available solar radiation resources. Solar radiation resources are measured using radiometers such as pyranometers (global horizontal irradiance) and pyrheliometers (direct normal irradiance). The accuracy of solar radiation data measured by radiometers depends not only on the specification of the instrument but also on a) the calibration procedure, b) the measurement conditions and maintenance, and c) the environmental conditions. Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This paper provides guidelines and recommended procedures for estimating the uncertainty in measurements by radiometers using the Guide to the Expression of Uncertainty (GUM) Method. Special attention is paid to the concept of data availability and its link to uncertainty evaluation.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

Life-cycle costs of high-performance cells

A life cycle cost analysis of high efficiency cells was presented. Although high efficiency cells produce more power, they also cost more to make and are more susceptible to array hot-spot heating. Three different computer analysis programs were used: SAMICS (solar array manufacturing industry costing standards), PVARRAY (an array failure mode/degradation simulator), and LCP (lifetime cost and performance). The high efficiency cell modules were found to be more economical in this study, but parallel redundancy is recommended.

Daniel, R.↗

Developing a Framework for Reference Cell Standards for PV Resource Applications

Quantifying and predicting electricity production from photovoltaic (PV) systems is based on measured or modeled irradiance data. These solar resource data consist of global horizontal irradiance, global tilted irradiance, direct normal irradiance, and diffuse horizontal irradiance, which are either derived from satellite observations validated against ground-based measurements or directly obtained from ground-based measurements. The ground-based measurements are made using thermopile or photodiode radiometers. For a PV plant, the efficiency of the energy production is verified by comparing measured output with the modeled production, which is computed using either modeled or measured irradiance data. Thus, plant performance assessments typically include the uncertainty of the transposition and, in some cases, decomposition of a given irradiance to convert to the appropriate plane-of-array (POA) irradiance corresponding to the orientation of the PV installation. Additionally, the various types of uncertainty in radiometric measurements or the modeled irradiance and the PV module specifications influence the model results and thereby further increase the uncertainty. An alternative method of assessing the PV system performance has been to use reference cells to measure the "PV resource." When used to calculate PV performance ratios, there are inherent systematic differences between radiometers and reference cells, such as spectral, directional, temperature, time responses, nonstability, and nonlinearity differences. Reference cells tend to mimic the performance and characteristics of a PV module more closely. In this report, a framework is proposed to develop standards that will better quantify and characterize the use of reference cells for PV resource measurements. The measurement from an appropriate reference cell in the POA correlates closely with the plant performance, reduces the number of modeling steps needed to simulate PV performance, and hence reduces the uncertainties of the comparisons. Because technologically matched reference cells and PV modules respond similarly to each wavelength of light that composes the incident solar radiation, the uncertainty associated with the changing spectral distribution of incident radiation during the day and year can be greatly reduced. This will reduce the overall uncertainty in estimated PV performance. The same can be said for the angle-of-incidence effects because the reference cells are deployed in the same POA as the PV module. At that point, the main sources of uncertainty are in modeling the temperature effect differences between the reference cells and the PV module and accounting for the difference between the short-circuit current monitored by the reference cells and max power point current and voltage at which the PV module operates. These sources of uncertainty are also associated with typical irradiance measurements made by pyranometers and pyrheliometers; however, typical irradiance measurements also include uncertainties associated with the spectral mismatch between thermopile or photodiode pyranometers and the PV module, which are minimized with the use of reference cells. To enhance the use of reference cells for resource assessment, we identify the necessary data, characteristics, and calibration methodologies of reference cells and how to standardize the use of these data and methods. Further, as we develop this framework, the classification of reference cells will be essential to provide guidance for selecting PV reference cells appropriate for a specific application. As we address the calibration and sources of uncertainties of reference cells, classification schemes and expected limits of performance with respect to certain parameters become important.

14 SOLAR ENERGY↗

A high efficiency photovoltaic module integrated converter with the asymmetrical half-bridge flyback converter

A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)

14 SOLAR ENERGY↗

Field studies of PERC and Al-BSF PV module performance loss using power and I-V timeseries

We have studied the degradation of both full-sized modules and minimodules with PERC and Al-BSF cell variations in fields while considering packaging strategies. We demonstrate the implementations of data-driven tools to analyze large numbers of modules and volumes of timeseries data to obtain the performance loss and degradation pathways. This data analysis pipeline enables quantitative comparison and ranking of module variations, as well as mapping and deeper understanding of degradation mechanisms. The best performing module is a half-cell PERC, which shows a performance loss rate ( PLR ) of −0.27 ± 0.12% per annum (%/ a ) after initial losses have stabilized. Minimodule studies showed inconsistent performance rankings due to significant power loss contributions via series resistance, however, recombination losses remained stable. Overall, PERC cell variations outperform or are not distinguishable from Al-BSF cell variations.

Curran, Alan J.↗

Hyperspectral Imaging and Spectroscopy of Fluorescently Coupled Acyl-CoA: Cholesterol Acyltransferase in Insect Cells

A high-performance hyperspectral imaging module with high throughput of light suitable for low-intensity fluorescence microscopic imaging and subsequent analysis, including single-pixel-defined emission spectroscopy, was tested on Sf21 insect cells expressing green fluorescence associated with recombinant green fluorescent protein linked or not with the membrane protein acyl-CoA:cholesterol acyltransferase. The imager utilized the phenomenon of optical activity as a new technique providing information over a spectral range of 220-1400 nm, and was inserted between the microscope and an 8-bit CCD video-rate camera. The resulting fluorescence image did not introduce observable image aberrations. The images provided parallel acquisition of well resolved concurrent spatial and spectral information such that fluorescence associated with green fluorescent protein alone was demonstrated to be diffuse within the Sf21 insect cell, and that green fluorescence associated with the membrane protein was shown to be specifically concentrated within regions of the cell cytoplasm. Emission spectra analyzed from different regions of the fluorescence image showed blue shift specific for the regions of concentration associated with the membrane protein.

Malak, H.↗

Reliability and Power Degradation Rates of PERC Modules Using Differentiated Packaging Strategies and Characterization Tools

The reliability, durability and lifetime performance of passivated emitter, rear cell (PERC) modules used in real-world PV power plants is a critical challenge underlying the rapid adoption and bankability of these PERC cells, whose high efficiency help reduce the levelized cost of electricity (LCOE). We propose a degradation-science study of PERC module degradation pathways, benchmarking them relative to known degradation mechanisms and pathways of the incumbent aluminum back surface field (Al-BSF) modules exposed to real-world and accelerated exposure conditions.

14 SOLAR ENERGY↗

On-demand formation of Lewis bases for efficient and stable perovskite solar cells

In the fabrication of FAPbI 3 -based perovskite solar cells, Lewis bases play a crucial role in facilitating the formation of the desired photovoltaic α-phase. However, an inherent contradiction exists in their role: they must strongly bind to stabilize the intermediate δ-phase, yet weakly bind for rapid removal to enable phase transition and grain growth. To resolve this conflict, we introduced an on-demand Lewis base molecule formation strategy. This approach utilized Lewis-acid-containing organic salts as synthesis additives, which deprotonated to generate Lewis bases precisely when needed and could be reprotonated back to salts for rapid removal once their role is fulfilled. This method promoted the optimal crystallization of α-phase FAPbI 3 perovskite films, ensuring the uniform vertical distribution of A-site cations, larger grain sizes and fewer voids at buried interfaces. Perovskite solar cells incorporating semicarbazide hydrochloride achieved an efficiency of 26.1%, with a National Renewable Energy Laboratory-certified quasi-steady-state efficiency of 25.33%. These cells retained 96% of their initial efficiency after 1,000 h of operation at 85 °C under maximum power point tracking. Additionally, mini-modules with an aperture area of 11.52 cm 2 reached an efficiency of 21.47%. This strategy is broadly applicable to all Lewis-acid-containing organic salts with low acid dissociation constants and offers a universal approach to enhance the performance of perovskite solar cells and modules.

14 SOLAR ENERGY↗

Stabilizing perovskite-substrate interfaces for high-performance perovskite modules

The interfaces of perovskite solar cells (PSCs) are important in determining their efficiency and stability, but the morphology and stability of imbedded perovskite-substrate interfaces have received less attention than have top interfaces. We found that dimethyl sulfoxide (DMSO), which is a liquid additive broadly applied to enhance perovskite film morphology, was trapped during film formation and led to voids at perovskite-substrate interfaces that accelerated the film degradation under illumination. Partial replacement of DMSO with solid-state carbohydrazide reduces interfacial voids. A maximum stabilized power conversion efficiency (PCE) of 23.6% was realized for blade-coated p-type/intrinsic/n-type (p-i-n) structure PSCs with no efficiency loss after 550-hour operational stability tests at 60°C. The perovskite mini-modules showed certified PCEs of 19.3 and 19.2%, with aperture areas of 18.1 and 50.0 square centimeters, respectively.

Chen, Shangshang↗

Electrochemical carbon dioxide concentrator subsystem math model

A steady state computer simulation model has been developed to describe the performance of a total six man, self-contained electrochemical carbon dioxide concentrator subsystem built for the space station prototype. The math model combines expressions describing the performance of the electrochemical depolarized carbon dioxide concentrator cells and modules previously developed with expressions describing the performance of the other major CS-6 components. The model is capable of accurately predicting CS-6 performance over EDC operating ranges and the computer simulation results agree with experimental data obtained over the prediction range.

Marshall, R. D.↗

Port of Galveston Solar Energy Project

This study on the performance characteristics of existing solar technologies in a maritime environment was funded by an award given to The Port of Galveston (POG) from the U.S. Department of Energy (DOE). The study includes research performed by The Center for Advanced Materials at the University of Houston (UH). The UH researchers examined how solar cell efficiencies and life spans can be improved by examining the performance of a variety of antireflective (AR) coatings mounted on the top of one of the POG’s Cruise Terminals. Supplemental supporting research was performed at the UH laboratories. An educational Kiosk was constructed with a 55” display screen providing information about solar energy, the research work UH performed at POG and real time data from the solar panels located on the roof of the Cruise Terminal. The Houston Advanced Research Center (HARC) managed the project.