Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The iQID Camera: An Ionizing-Radiation Quantum Imaging Detector

We have developed and tested a novel, ionizing-radiation Quantum Imaging Detector (iQID). This scintillation-based detector was originally developed as a high-resolution gamma-ray imager, called BazookaSPECT, for use in single-photon emission computed tomography (SPECT). Recently, we have investigated the detectors response and imaging potential with other forms of ionizing radiation including alpha, neutron, beta, and fission fragment particles. The detector’s response to a broad range of ionizing radiation has prompted its new title. The principle operation of the iQID camera involves coupling a scintillator to an image intensifier. The scintillation light generated particle interactions is optically amplified by the intensifier and then re-imaged onto a CCD/CMOS camera sensor. The intensifier provides sufficient optical gain that practically any CCD/CMOS camera can be used to image ionizing radiation. Individual particles are identified and their spatial position (to sub-pixel accuracy) and energy are estimated on an event-by-event basis in real time using image analysis algorithms on high-performance graphics processing hardware. Distinguishing features of the iQID camera include portability, large active areas, high sensitivity, and high spatial resolution (tens of microns). Although modest, iQID has energy resolution that is sufficient to discrimate between particles. Additionally, spatial features of individual events can be used for particle discrimination. An important iQID imaging application that has recently been developed is single-particle, real-time digital autoradiography. In conclusion, we present the latest results and discuss potential applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Screening of Catalytic H 2 Production

Hydrogenases, ferredoxins, and ferredoxin-NADP + reductases (FNR) are redox proteins that mediate electron metabolism in vivo, and are also potential components for biological H 2 production technologies. A high-throughput H 2 production assay device (H 2 PAD) is presented that enables simultaneous evaluation of 96 individual H 2 production reactions to identify components that improve performance. Using a CCD camera and image analysis software, H 2 PAD senses the chemo-optical response of Pd/WO 3 thin films to the H 2 produced. H 2 PAD-enabled discovery of hydrogenase and FNR mutants that enhance biological H 2 production is reported. From a library of 10 080 randomly mutated Clostridium pasteurianum [FeFe] hydrogenases, we found a mutant with nearly 3-fold higher H 2 production specific activity. From a library of 400 semi-randomly mutated Oryza sativa FNR, the top hit enabled a 60 % increase in NADPH-driven H 2 production rates. H 2 PAD can also facilitate elucidation of fundamental biochemical mechanisms within these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital Image Correlation as an Experimental Modal Analysis Capability

Digital image correlation (DIC) is an established test technique in several fields including quasi-static displacement measurements. Recently there has been growing interest in using DIC to measure structural dynamic response and even extract modal parameters from that information. Although high-speed cameras have become more ubiquitous, there are no commercial end-to-end packages for modal analysis based on image data, particularly when combined with traditional data acquisition systems. As such, the practitioner is left to develop several key data processing capabilities, hardware interface equipment, and testing practices themselves. This work highlights several practical aspects that have been encountered while establishing DIC as a viable modal testing capability in a laboratory environment.

47 OTHER INSTRUMENTATION↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from the Rapid-response Spectrophotometric Characterization of Near-Earth Objects Using RATIR

As part of our multi-observatory, multifilter campaign, we present r–i color observations of 82 near-Earth objects (NEOs) obtained with the reionization and transients infrared camera (RATIR) instrument on the 1.5 m robotic telescope at the San Pedro Martir’s National Observatory in Mexico. Our project is particularly focused on rapid-response observations of small (≲850 m) NEOs. The rapid response and the use of spectrophotometry allows us to constrain the taxonomic classification of NEOs with high efficiency. Here we present the methodology of our observations and our result, suggesting that the ratio of C-type to S-type asteroids in a size range of ~30–850 m is 1.1, which is in accordance with our previous results. We also find that 10% of all NEOs in our sample are neither C- nor S-type asteroids.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors

Purpose: In this paper, a photomultiplier tube (PMT) array dosimetry system has been developed and tested for the real-time readout of multiple scintillation signals from fiber optic dosimeters. It provides array dosimetry with the advantages in sensitivity provided by a PMT, but without the need for a separate PMT for each detector element. Methods: The PMT array system consisted of a multianode PMT, a multichannel data acquisition system, housing and optic fiber connections suitable for clinical use. The reproducibility, channel uniformity, channel crosstalk, acquisition speed, and sensitivity of the PMT array were quantified using a constant light source. Its performance was compared to other readout systems used in scintillation dosimetry. An in vivo HDR brachytherapy treatment was used as an example of a clinical application of the dosimetry system to the measurement of dose at multiple sites in the rectum. The PMT array system was also tested in the pulsed beam of a linear accelerator to test its response speed and its application with two separate methods of Cerenkov background removal. Results: The PMT array dosimetry system was highly reproducible with a measurement uncertainty of 0.13% for a 10 s acquisition period. Optical crosstalk between neighboring channels was accounted for by omitting every second channel. A mathematical procedure was used to account for the crosstalk in next-neighbor channels. The speed and sensitivity of the PMT array system were found be superior to CCD cameras, allowing for measurement of more rapid changes in dose rate. This was further demonstrated by measuring the dose delivered by individual photon pulses of a linear accelerator beam. Conclusions: The PMT array system has advantages over CCD camera-based systems for the readout of scintillation light. It provided a more sensitive, more accurate, and faster response to meet the demands of future developments in treatment delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-518: Development and Characterization of a Gated Treatment System Implemented with An In-House Optical Tracking System and the Elekta Response Interface

Purpose: To report the development and characterization of the first in-house gating system implemented with an optical tracking system (OTS) and the Elekta Response™ interface. Methods: The Response™ connects a patient tracking system with a linac, enabling the tracking system to control radiation delivery. The developed system uses an in-house OTS to monitor patient breathing. The OTS consists of two infrared-based cameras, tracking markers affixed on patient. It achieves gated or breath-held (BH) treatment by calling beam ON/OFF functions in the Response™ dynamic-link library (DLL). A 4D motion phantom was used to evaluate its dosimetric and time delay characteristics. Two FF- and two FFF-IMRT beams were delivered in non-gated, BH and gated mode. The sinusoidal gating signal had a 6 sec period and 15 mm amplitude. The duty cycle included 10%, 20%, 30% and 50%. The BH signal was adapted from the sinusoidal wave by inserting 15 sec BHs. Each delivery was measured with a 2D diode array (MapCHECK™) and compared with the non-gated delivery using gamma analysis (3%). The beam ON/OFF time was captured using the service graphing utility of the linac. Results: The gated treatments were successfully delivered except the 10% duty cycle. The BH delivery had perfect agreement (100%) with non-gated delivery; the agreement of gated delivery decreased from 99% to 88% as duty cycle reduced from 50% to 20%. The beam on/off delay was on average 0.25/0.06 sec. The delivery time for the 50%, 30% and 20% duty cycle increased by 29%, 71% and 139%, respectively. No dosimetric or time delay difference was noticed between FF- and FFF-IMRT beams. Conclusion: The in-house gating system was successfully developed with dosimetric and time delay characteristics in line with published results for commercial systems. It will be an important platform for further research and clinical development of gated treatment.

43 PARTICLE ACCELERATORS↗

The variation in self-organized anode plasma pattern structure with solution electrolyte type in 1 atm DC glow discharge

Abstract Plasma self-organization on anode surfaces in 1 atm DC glow discharges remains poorly understood. This effort aims to elucidate the nature of self-organization through the experimental study of resulting patterns on liquid anode surfaces with 13 different electrolytes and thus improves our understanding of the underlying physical processes that give rise to self-organization by investigating electrolyte sensitivity. Self-organization pattern formation and behavior were studied as a function of discharge current, solution ionic strength, and their chemical property evaluation. The response of the patterns to variation in these parameters was measured using an imaging camera and optical emission spectroscopy. Observed pattern characteristic length scales for all of the electrolytes were ranged from 2 to 13 mm and typically increased with current over the investigated range of 20–80 mA. Complex self-organized pattern structures not reported to date were also observed. The parameters associated with pattern formation and morphology complexity are discussed and summarized.

Physics↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

Time-Encoded Imagers

We have developed two neutron detector systems based on time-encoded imaging and demonstrated their applicability toward non-proliferation missions. The 1D-TEI system was designed for and evaluated against the ability to detect Special Nuclear Material (SNM) in very low signal to noise environments; in particular, very large stand-off and/or weak sources that may be shielded. We have demonstrated significant detection (>5 sigma) of a 2.8e5 n/s neutron fission source at 100 meters stand-off in 30 min. If scaled to an IAEA significant quantity of Pu, we estimate that this could be reduced to as few as ~5 minutes. In contrast to simple counting detectors, this was accomplished without the need of previous background measurements. The 2D-TEI system was designed for high resolution spatial mapping of distributions of SNM and proved feasibility of twodimensional fast neutron imaging using the time encoded modulation of rates on a single pixel detector. Because of the simplicity of the TEI design, there is much lower systematic uncertainty in the detector response typical coded apertures. Other imaging methods require either multiple interactions (e.g. neutron scatter camera or Compton imagers), leading to intrinsically low efficiencies, or spatial modulation of the signal (e.g., Neutron Coded Aperture Imager (Hausladen, 2012)), which requires a complicated, high channel count, and expensive position sensitive detector. In contrast, a single detector using a time-modulated collimator can encode directional information in the time distribution of detected events. This is the first investigation of time-encoded imaging for nuclear nonproliferation applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIF S600D Snout Final Design Review (FDR) Report

The S600D is a one or two channel mirror spectrometer which will provide temporal and spatial soft x-ray data in a single NIF shot. It mounts to the existing DIM Imaging Streak Camera (DISC) using the standard NIF kinematic mount design. LLE and LLNL each have responsibilities for the snout. The Laboratory for Laser Energetics (LLE) is subcontracted to design, fabricate, and align the S600D Snout at the OMEGA Laser facility in Rochester, NY before delivery to LLNL. The Snout consists of the Mirror Mount, Kinematic interface to DISC, Slit mount, and filter pack mount. Lawrence Livermore National Laboratory (LLNL) is responsible to fabricate and deliver the Mirror substrates and coatings, Pinhole slits and collimators, Filter material, and Image plates. LLNL is also responsible for the Requirements Definition, Concept of Operations, Debris and Shrapnel analysis, Stakeholder reviews and Integration in the NIF Facility.

42 ENGINEERING↗

K2 Observations of SN 2018oh Reveal a Two-component Rising Light Curve for a Type Ia Supernova

We present an exquisite 30 minute cadence Kepler (K2) light curve of the Type Ia supernova (SN Ia) 2018oh (ASASSN-18bt), starting weeks before explosion, covering the moment of explosion and the subsequent rise, and continuing past peak brightness. These data are supplemented by multi-color Panoramic Survey Telescope (Pan-STARRS1) and Rapid Response System 1 and Cerro Tololo Inter-American Observatory 4 m Dark Energy Camera (CTIO 4-m DECam) observations obtained within hours of explosion. The K2 light curve has an unusual two-component shape, where the flux rises with a steep linear gradient for the first few days, followed by a quadratic rise as seen for typical supernovae (SNe) Ia. This "flux excess" relative to canonical SN Ia behavior is confirmed in our i-band light curve, and furthermore, SN 2018oh is especially blue during the early epochs. The flux excess peaks 2.14 ± 0.04 days after explosion, has a FWHM of 3.12 ± 0.04 days, a blackbody temperature of $T = 17,500^{+11,500}_{-9,000}$ K, a peak luminosity of 4.3 ± 0.2 x 10 38 erg s -1 , and a total integrated energy of 1.27 ± 0.01 x 10 43 erg. We compare SN 2018oh to several models that may provide additional heating at early times, including collision with a companion and a shallow concentration of radioactive nickel. While all of these models generally reproduce the early K2 light curve shape, we slightly favor a companion interaction, at a distance of ~ 2 x 10 12 based on our early color measurements, although the exact distance depends on the uncertain viewing angle. Additional confirmation of a companion interaction in future modeling and observations of SN 2018oh would provide strong support for a single-degenerate progenitor system.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel technology of non-contact real-time radiation damage sensors for high power targets.

This report summarizes the contributions of an intern participating in the Community College Internship (CCI) program at Fermilab, focusing on the development of a novel, non-contact, real-time radiation damage sensor technology. The core objective is to create a reliable sensor capable of measuring radiation-induced degradation on high-power targets without physical contact. The experiment involves using a Class 3B supercontinuum laser directed toward a single material sample placed within a vacuum test chamber. The laser beam reflects off the sample's surface, with changes in reflectivity, indicative of radiation damage, measured by a spectrometer positioned at the chamber’s output port. The intern’s primary responsibilities included designing an interlock system to ensure laser operational safety, developing a camera-based monitoring system using Raspberry Pi devices, and creating structural supports using 3D modeling and printing techniques. Components for the interlock and camera systems were successfully designed and ordered, with preliminary 3D models printed and refined through iterative testing. Challenges encountered in the 3D printing process, such as fragile initial prototypes and difficult support removal, were overcome by adjusting printer settings and incorporating design enhancements like chamfered edges. Future activities, pending component delivery, involve installing and configuring the interlock and camera systems, as well as further improving the structural supports. Overall, the internship significantly enhanced the intern’s technical proficiency in hardware design, software integration, and advanced 3D printing, contributing directly to Fermilab’s operational safety standards and experimental effectiveness in high-energy physics research.

Pumarino Meza, Rafael [Unlisted; Fermilab]↗

Characterization of the Polarization Beam Response of SPT-3G Using Point Sources

Precise measurements of cosmic microwave background (CMB) polarization require rigorous control of instrumental systematics. For the South Pole Telescope's third-generation camera (SPT-3G), which observes in three bands centered near 95, 150, and 220 GHz, accurate beam characterization is critical for interpreting the polarized mm-wave sky. We present direct measurements of SPT-3G's polarized beam response from observations of 100 bright extragalactic point sources. Previous SPT-3G power spectrum analyses introduced a phenomenological parameter, $β_{\rm pol}$, to describe the polarization preserved in beam sidelobes, and found evidence for significant depolarization from the requirement of inter-frequency polarization power spectrum consistency. Our direct measurements yield $β_{\rm pol}=0.89\pm0.10$ at 95 GHz, $1.08\pm0.10$ at 150 GHz, and $0.90\pm0.22$ at 220 GHz, indicating minimal sidelobe depolarization. We validate these results with systematic tests of posterior sampling versus bootstrap resampling, real-space versus Fourier-space analysis, temperature-to-polarization leakage handling, covariance determination, and source selection. Compared to values inferred from previous cosmological analyses, our results differ by an effective $1.3σ$. This apparent discrepancy is model dependent, because the point source analysis derives much of its $β_{\rm pol}$ constraining power from higher multipoles than the power spectrum analysis. These measurements therefore admit three explanations for the frequency-dependent residuals observed in the power spectrum analysis: a statistical fluctuation, the need for more sophisticated polarized beam models, or systematics other than beam depolarization.

de Haan, T. [KEK, Tsukuba]↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved image quality in pinhole SPECT by accurate modeling of the point spread function in low magnification systems

Purpose: Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of reconstructed images. The aim of this study was to quantitatively assess the impact that an accurate modeling of spatially variant collimator/detector response has on image-quality parameters, using a low magnification SPECT system equipped with a pinhole collimator and a small gamma camera. Methods: Three methods were used to model the point spread function (PSF). For the first, only the geometrical pinhole aperture was included in the PSF. For the second, the septal penetration through the pinhole collimator was added. In the third method, the measured intrinsic detector response was incorporated. Tomographic spatial resolution was evaluated and contrast, recovery coefficients, contrast-to-noise ratio, and noise were quantified using a custom-built NEMA NU 4–2008 image-quality phantom. Results: A high correlation was found between the experimental data corresponding to intrinsic detector response and the fitted values obtained by means of an asymmetric Gaussian distribution. For all PSF models, resolution improved as the distance from the point source to the center of the field of view increased and when the acquisition radius diminished. An improvement of resolution was observed after a minimum of five iterations when the PSF modeling included more corrections. Contrast, recovery coefficients, and contrast-to-noise ratio were better for the same level of noise in the image when more accurate models were included. Ring-type artifacts were observed when the number of iterations exceeded 12. Conclusions: Accurate modeling of the PSF improves resolution, contrast, and recovery coefficients in the reconstructed images. To avoid the appearance of ring-type artifacts, the number of iterations should be limited. In low magnification systems, the intrinsic detector PSF plays a major role in improvement of the image-quality parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Orbit Performance of the Hard X-Ray Detector on Borad Suzaku

The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of {approx}4 keV (FWHM) at 40 keV and {approx}11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detector Response Function and Directional Gamma-Ray Source Calculations for Polaris

A Directional Unfolded Source Term (DUST) method was developed to compute directionally resolved gamma-ray source terms based on back-projection spectra synthesized by Compton Cameras. Spectral features in the unprocessed spectra are indistinct primarily because the rotational angles for the conical projections cannot be determined, so probability distributions are constructed from overlapping cones. The DUST method uses an angular response function to compute a covariance matrix, which is used to process count rates in back-projection spectra by linear regression to partition the gamma-rays among several spatial regions. This method was applied to analyze data collected by the Polaris detector during an evaluation that was conducted at Oak Ridge National Laboratory (ORNL). The evaluation includes measurements of calibration sources with angular separations ranging from 1° to more than 50°. Measurements were also performed for cylindrical depleted uranium castings and a 137 Cs source inside a large polyethylene sphere. The DUST algorithm was able to differentiate gamma-rays emitted by 137 Cs and 60 Co when the sources were separated by less than 2°, but separation greater than 10° was required to isolate the 133 Ba emission from gamma-rays emitted by the other sources. The computed source terms were consistent with emission profiles from the calibration sources and from models of the spatially-extended sources. Methods for viewing radiation profiles were also evaluated because user input is required to select spatial regions of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗