Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗

The AGORA High-resolution Galaxy Simulations Comparison Project. III. Cosmological Zoom-in Simulation of a Milky Way–mass Halo

In this work, we present a suite of high-resolution cosmological zoom-in simulations to z = 4 of a 10 12 M⊙ halo at z = 0, obtained using seven contemporary astrophysical simulation codes (Art-I, Enzo, Ramses, Changa, Gadget-3, Gear, and Gizmo) widely used in the numerical galaxy formation community. The physics prescriptions for gas cooling and heating and star formation are the same as the ones used in our previous Assembling Galaxies of Resolved Anatomy (AGORA) disk comparison but now account for the effects of cosmological processes such as the expansion of the universe, intergalactic gas inflow, and the cosmic ultraviolet background radiation emitted by massive stars and quasars. In this work, we introduce the most careful comparison yet of galaxy formation simulations run by different code groups, together with a series of four calibration steps each of which is designed to reduce the number of tunable simulation parameters adopted in the final run. In the first two steps, we methodically calibrate the gas physics, such as cooling and heating, in simulations without star formation. In the third step, we seek agreement on the total stellar mass produced with the common star formation prescription used in the AGORA disk comparison, in stellar-feedback-free simulations. In the last calibration step, we activate stellar feedback, where each code group is asked to set the feedback prescription to as close to the most widely used one in its code community as possible, while aiming for convergence in the stellar mass at z = 4 to the values predicted by semiempirical models. After all the participating code groups successfully complete the calibration steps, we achieve a suite of cosmological simulations with similar mass assembly histories down to z = 4. With numerical accuracy that resolves the internal structure of a target halo (≲100 physical pc at z = 4), we find that the codes overall agree well with one another, e.g., in gas and stellar properties, but also show differences, e.g., in circumgalactic medium (CGM) properties. We argue that, if adequately tested in accordance with our proposed calibration steps and common parameters, high-resolution cosmological zoom-in simulations can have robust and reproducible results. New code groups are invited to join and enrich this comparison by generating equivalent models or to test the code's compatibility on their own, by adopting the common initial conditions, the common easy-to-implement physics package, and the proposed calibration steps. Further analyses of the zoom-in simulations presented here will be presented in forthcoming reports from the AGORA Collaboration, including studies of the CGM, simulations by additional codes, and results at lower redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliable Power Rating of Perovskite PV Modules: Preprint

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group’s steady-state performance calibration protocol (i.e., Asymptotic PMAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic PMAX. Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Specifications of Cladding Diameter Measurements Conducted at AGHCF

Fuel element diameter data was collected on-site at the Alpha-Gamma Hot Cell Facility (AGHCF) before and after out-of-pile furnace transient tests of fuel elements. Available data records have been collected and preserved in the Out-of-Pile Transient Database (OPTD). This data is used to determine the transient-induced changes in fuel element diameter, or cladding strain, for the Whole Pin Furnace (WPF) tests. Fuel element diameter was measured by contact profilometry along the length of the fuel pin at specified rotational orientations and/or by a manually operated micrometer at several discrete axial locations along the pin. The Alpha-Gamma Hot Cell Facility Operations Manual details the way the facility operated, organizational and oversight responsibilities, and procedures for examination of samples. The working version of the manual at the time of the whole pin furnace tests and the test pin examinations is Doc. No. IPS-2-00-00, dated June 1989. This specification was developed using the operations manual and recovered measurement records in consultation with subject matter experts (SMEs). The measurement methods, format of the available post-test examination (PTE) data, and recommended methods for use and interpretation of that data are summarized. Section 2 describes the available diameter measurement data for the WPF tests with guidance for interpretation and usage, and Section 3 describes the instrument measurement procedures and calibration methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A protocol for calculating basal melt rates in the ISMIP6 Antarctic ice sheet projections

Climate model projections have previously been used to compute ice shelf basal melt rates in ice sheet models, but the strategies employed – e.g., ocean input, parameterization, calibration technique, and corrections – have varied widely and are often ad hoc. Here, a methodology is proposed for the calculation of circum-Antarctic basal melt rates for floating ice, based on climate models, that is suitable for ISMIP6, the Ice Sheet Model Intercomparison Project for CMIP6 (6th Coupled Model Intercomparison Project). The past and future evolution of ocean temperature and salinity is derived from a climate model by estimating anomalies with respect to the modern day, which are added to a present-day climatology constructed from existing observational datasets. Temperature and salinity are extrapolated to any position potentially occupied by a simulated ice shelf. A simple formulation is proposed for a basal melt parameterization in ISMIP6, constrained by the observed temperature climatology, with a quadratic dependency on either the nonlocal or local thermal forcing. Two calibration methods are proposed: (1) based on the mean Antarctic melt rate (MeanAnt) and (2) based on melt rates near Pine Island's deep grounding line (PIGL). Future Antarctic mean melt rates are an order of magnitude greater in PIGL than in MeanAnt. The PIGL calibration and the local parameterization result in more realistic melt rates near grounding lines. PIGL is also more consistent with observations of interannual melt rate variability underneath Pine Island and Dotson ice shelves. This work stresses the need for more physics and less calibration in the parameterizations and for more observations of hydrographic properties and melt rates at interannual and decadal timescales.

54 ENVIRONMENTAL SCIENCES↗

Estimation Matrix Calibration of PMU Data-driven State Estimation Using Neural Network

Linear state estimation (LSE) is a phasor measurement unit (PMU) data-based power system state estimation that incorporates a linear measurement model in rectangular coordinates. Due to the high computational efficiency and high observational time-resolution, LSE can act as a supplementary state estimation in a wide-area monitoring system (WAMS). The performance of LSE is relatively sensitive to noises in measurements. Therefore, the estimation accuracy relies heavily on the accuracy of the estimation matrix, which is directly influenced by the measurement weight matrix. This paper proposes two novel calibration method of the estimation matrix using neural networks. One is based on the minimum absolute network loss (ANL), and the other is based on the minimum average squared network loss (ASNL). Both methods are tested and compared with LSE algorithms on the IEEE 14-bus system

neural network↗

The WRF-Solar Ensemble Prediction System to Provide Solar Irradiance Probabilistic Forecasts

In this study, we introduce the recently developed WRF-solar ensemble prediction system and a calibration method. The performances of forecast models are evaluated using the National Solar Radiation Database observational analysis for day-ahead solar irradiance predictions. The results demonstrate that the ensemble forecast improves the quality of the forecasts by considering the uncertainty of each ensemble member. The analog ensemble calibration contributed to the reduction of positive bias and an overall improvement in the probabilistic attributes, such as reliability and statistical consistency.

14 SOLAR ENERGY↗

The WRF-Solar Ensemble Prediction System to Provide Solar Irradiance Probabilistic Forecasts

In this study, we introduce the recently developed WRF-Solar Ensemble System (WRF-Solar EPS) and a calibration method. The performances of forecast models are evaluated using the National Solar Radiation Data Base (NSRDB) observational analysis for day-ahead solar irradiance predictions. The results demonstrate that the ensemble forecast improves the quality of the forecasts by taking into account the uncertainty of each ensemble member. The Analog Ensemble (AnEn) calibration contributed to the reduction of positive bias and an overall improvement in the probabilistic attributes such as reliability and statistical consistency.

analog ensemble↗

Interlaced Characterization and Calibration (ICC) for Improved Computational Simulation Credibility

Accurate material characterization and model calibration are pivotal for simulations used for high-consequence engineering decisions. Current characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data is collected for a specific model of interest, (3) provide only mean parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work developed a new paradigm—coined Interlaced Characterization and Calibration (ICC)—which drives forward the state-of-the-art in model calibration by bringing together recent advancements into one improved workflow. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) provides uncertainty metrics on the calibrated model parameters, and (4) incorporates these advances into a quasi real-time feedback loop. The ICC framework was validated synthetically with both low-fidelity and high-fidelity simulations paired with several different elastoplastic material models, and was also demonstrated experimentally with an aluminum 6061 cruciform exemplar specimen. Results showed that the ICC framework—in which Bayesian optimal experimental design actively guided the experiment— resulted in calibrations with similar or better accuracy than predetermined experiments based on subject matter expertise. Moreover, the ICC framework produced a complete model calibration— with quantified uncertainties on model parameters—in 1 week, a 5 - 10× increase in efficiency over traditional approaches. Thus, the ICC paradigm improves both the calibration process and quality, by (1) improving efficiency, which increases agility of solid mechanics modeling and enables utilization of computational simulation (CompSim) at earlier stages of the design cycle and (2) providing quantified, and in some cases reduced, parameter uncertainties, which increases confidence in model predictions and supports credible decision making.

97 MATHEMATICS AND COMPUTING↗

First Sagittarius A* Event Horizon Telescope Results. II. EHT and Multiwavelength Observations, Data Processing, and Calibration

We present Event Horizon Telescope (EHT) 1.3 mm measurements of the radio source located at the position of the supermassive black hole Sagittarius A* (Sgr A*), collected during the 2017 April 5–11 campaign. The observations were carried out with eight facilities at six locations across the globe. Novel calibration methods are employed to account for Sgr A*'s flux variability. The majority of the 1.3 mm emission arises from horizon scales, where intrinsic structural source variability is detected on timescales of minutes to hours. The effects of interstellar scattering on the image and its variability are found to be subdominant to intrinsic source structure. The calibrated visibility amplitudes, particularly the locations of the visibility minima, are broadly consistent with a blurred ring with a diameter of ∼50 μas, as determined in later works in this series. Contemporaneous multiwavelength monitoring of Sgr A* was performed at 22, 43, and 86 GHz and at near-infrared and X-ray wavelengths. Several X-ray flares from Sgr A* are detected by Chandra, one at low significance jointly with Swift on 2017 April 7 and the other at higher significance jointly with NuSTAR on 2017 April 11. The brighter April 11 flare is not observed simultaneously by the EHT but is followed by a significant increase in millimeter flux variability immediately after the X-ray outburst, indicating a likely connection in the emission physics near the event horizon. We compare Sgr A*’s broadband flux during the EHT campaign to its historical spectral energy distribution and find that both the quiescent emission and flare emission are consistent with its long-term behavior.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Application of Generalized Standard Addition Method and Ultraviolet Spectroscopy to Quantify Electrolytic Depolymerization of Lignin

Industrial lignin waste is an important byproduct of bio-refineries and the paper industry. Depolymerization of this industrial lignin could generate useful aromatic compounds. This group has focused on electrolytic decomposition of biorefinery lignin. To quantify electrolytic decomposition of the lignin in a highly caustic solution, ultraviolet (UV) spectroscopy provides a useful probe. The conversion of the neat lignin to the oxidized products achieved by the electrolytic reactor may be measured by quantifying the amount of unreacted neat lignin that remains in the effluent. Because the properties of electrolytic decomposition products are largely unknown, a useful approach to quantify decomposition of the neat lignin is to use a multivariate calibration method referred to as the generalized standard addition method (GSAM). In this approach, the electrolytic decomposition products represent a background interference and the neat lignin that remains can be quantified. Furthermore, this approach allows the conversion of the neat lignin to be calculated in a solution that is a complex mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of hydrogen atoms measurement using femtosecond two-photon laser-induced fluorescence

What we believe to be a new calibration method for H-fs-TALIF is proposed, and the ratio of two-photon absorption cross-sections, σ (2) , for atomic hydrogen (H) and krypton (Kr) is determined using the broadband emission of a femtosecond laser system. The estimated ratio of the two-photon absorption cross-sections for H and Kr is σ (2) (Kr)/σ (2) (H) = 0.027 ± 20%, which is nearly twenty times lower than values previously obtained with narrowband nanosecond lasers. This discrepancy highlights the need for independent calibration of TALIF measurements for a specific laser pulsewidth range.

Starikovskiy, Andrey [Princeton Univ., NJ (United ↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗