Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration and fitting methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cosmology intertwined: A review of the particle physics, astrophysics, and cosmology associated with the cosmological tensions and anomalies

The standard Λ Cold Dark Matter (ΛCDM) cosmological model provides a good description of a wide range of astrophysical and cosmological data. However, there are a few big open questions that make the standard model look like an approximation to a more realistic scenario yet to be found. In this paper, we list a few important goals that need to be addressed in the next decade, taking into account the current discordances between the different cosmological probes, such as the disagreement in the value of the Hubble constant H 0 , the σ 8 – S 8 tension, and other less statistically significant anomalies. While these discordances can still be in part the result of systematic errors, their persistence after several years of accurate analysis strongly hints at cracks in the standard cosmological scenario and the necessity for new physics or generalisations beyond the standard model. In this paper, we focus on the 5.0 σ tension between the Planck CMB estimate of the Hubble constant H 0 and the SH0ES collaboration measurements. After showing the H 0 evaluations made from different teams using different methods and geometric calibrations, we list a few interesting new physics models that could alleviate this tension and discuss how the next decade's experiments will be crucial. Moreover, we focus on the tension of the Planck CMB data with weak lensing measurements and redshift surveys, about the value of the matter energy density Ω m , and the amplitude or rate of the growth of structure ( σ 8 , f σ 8 ). We list a few interesting models proposed for alleviating this tension, and we discuss the importance of trying to fit a full array of data with a single model and not just one parameter at a time. Additionally, we present a wide range of other less discussed anomalies at a statistical significance level lower than the H 0 – S 8 tensions which may also constitute hints towards new physics, and we discuss possible generic theoretical approaches that can collectively explain the non-standard nature of these signals. Finally, we give an overview of upgraded experiments and next-generation space missions and facilities on Earth that will be of crucial importance to address all these open questions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using a 1D Radially Symmetric Coda Envelope Model for Robust Moment Magnitude ( M w ) Estimation in Iraq’s Tectonically Diverse Zones

Robust estimation of moment magnitude (M w ) can be challenging for Iraq due to the strong lateral heterogeneity across diverse tectonic zones. We aim to improve moment magnitude estimation by investigating the reliability of using a 1D coda envelope model in diverse tectonic zones of different lateral effects and offer a way forward for reliable estimates of M w for small events that are difficult to waveform model. Iraq comprises two main tectonic zones: (1) the Outer platform, consisting of the northwestern Zagros fold-thrust belt and the Mesopotamian foredeep, and (2) the Inner Arabian platform which is overlain by the Iraqi desert. A simple 1D coda envelope model was used because coda waves have a low sensitivity to the source and path heterogeneity. Three separate coda calibrations were conducted to investigate the robustness of a single 1D calibration to fit the country: Whole-region calibration, Zagros calibration, and Mesopotamia calibration. In the whole-region calibration, we used stations from both the Zagros and Mesopotamia zones. In the two other calibration models, we used only stations that were in those particular zones. Ground-truth reference spectra derived from the coda spectral ratio method were used to constrain high-frequency site terms. There was no drastic difference when comparing the moment magnitudes calculated from the waveform modeling and the three calibration models. The results show that the 1D coda envelope model is a reliable method even for a region with diverse tectonic zones. Therefore, we recommend using the whole-region calibration model for moment magnitude estimation that provides more complete path coverage and avoids biases introduced by path correction failures. The proposed calibration is a fundamental step in updating the comprehensive earthquake catalog and probabilistic seismic hazard assessments for Iraq.

58 GEOSCIENCES↗

SDSS-IV MaStar: Stellar parameter determination with continuum-supplemented full-spectrum fitting

We present a stellar parameter catalog built to accompany the MaStar Stellar Library, which is a comprehensive collection of empirical, medium-resolution stellar spectra. We constructed this parameter catalog by using a multicomponent χ 2 fitting approach to match MaStar spectra to models generated by interpolating the ATLAS9-based BOSZ model spectra. The total χ 2 for a given model is defined as the sum of components constructed to characterize narrow-band features of observed spectra (e.g., absorption lines) and the broadband continuum shape separately. Extinction and systematics due to flux calibration were taken into account in the fitting. The χ 2 distribution for a given region of model space was sampled using a Markov chain Monte Carlo (MCMC) algorithm, the data from which were then used to extract atmospheric parameter estimates (T eff , log g, [Fe/H], and [α/Fe]), their corresponding uncertainties, and direct extinction measurements. Two methods were used to extract parameters and uncertainties: one that accepts the MCMC’s prescribed minimum-χ 2 result, and one that uses Bayesian inference to compute a likelihood-weighted mean from the χ 2 distribution sampled by the MCMC. Results were evaluated for internal consistency using repeat observations where available and by comparing them with external data sets (e.g., APOGEE-2 and Gaia DR2). Our spectral-fitting exercise reveals possible deficiencies in current theoretical model spectra, illustrating the potential power of MaStar spectra for helping to improve the models. This paper represents an update to the parameters that were originally presented with SDSS-IV DR17. The MaStar parameter catalog containing our BestFit results is available on the SDSS-IV DR17 website as part of version 2 of the MaStar stellar parameter value-added catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement and calibration of non-linear shear terms in galaxy cluster fields

Introduction Galaxy cluster lensing is a powerful tool for measuring the mass of galaxy clusters, but accurate shear measurement and calibration are critical to obtaining reliable results. This study focuses on the measurement and calibration of weak lensing shears to improve mass estimates in cluster lensing. To deal with the problem, we first developed an image simulation pipeline, jedisim, which utilizes galaxy images extracted from the Hubble Space Telescope (HST) Ultra Deep Field (UDF) and the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). Methods The simulations represent realistic galaxy distributions and morphologies as input sources. The foreground halo with a Navarro–Frenk–White (NFW) profile is constructed such that the lensing signals of background galaxies can be measured by the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Science Pipelines. By comparing the measured reduced shear g meas and the true reduced shear g true , we observe non-linearity up to g ≲ 0.6 . We fit polynomials to the data with quadratic correction adequate to g ≲ 0.4 . Meanwhile, we conduct mass estimates using the pzmassfitter code on four different clusters. Results The mass estimate results are significantly improved after applying the shear calibration derived from the present work—from 4.954 ± 0.504 × 1 0 14 M ⊙ to 10.507 ± 0.498 × 1 0 14 M ⊙ after calibration for a simulated cluster with the mass of 10 × 1 0 14 M ⊙ . In multiple cases of validation, the estimated results are all consistent with true cluster mass. Discussion This study yields the first relationship between reality and shape measurement of the LSST Science Pipelines and serves as the first step toward the overall goal of mass calibration in cluster lensing. By addressing the challenges in shear measurement and calibration, we aim to enhance the accuracy and reliability of mass estimates in galaxy cluster lensing studies.

Astronomy & Astrophysics↗

Computationally efficient and error aware surrogate construction for numerical solutions of subsurface flow through porous media

Limiting the injection rate to restrict the pressure below a threshold at a critical location can be an important goal of simulations that model the subsurface pressure between injection and extraction wells. The pressure is approximated by the solution of Darcy’s partial differential equation for a given permeability field. The subsurface permeability is modeled as a random field since it is known only up to statistical properties. This induces uncertainty in the computed pressure. Solving the partial differential equation for an ensemble of random permeability simulations enables estimating a probability distribution for the pressure at the critical location. These simulations are computationally expensive, and practitioners often need rapid online guidance for real-time pressure management. An ensemble of numerical partial differential equation solutions is used to construct a Gaussian process regression model that can quickly predict the pressure at the critical location as a function of the extraction rate and permeability realization. The Gaussian process surrogate analyzes the ensemble of numerical pressure solutions at the critical location as noisy observations of the true pressure solution, enabling robust inference using the conditional Gaussian process distribution. Our first novel contribution is to identify a sampling methodology for the random environment and matching kernel technology for which fitting the Gaussian process regression model scales as O ( n log n ) instead of the typical O ( n 3 ) rate in the number of samples n used to fit the surrogate. The surrogate model allows almost instantaneous predictions for the pressure at the critical location as a function of the extraction rate and permeability realization. Our second contribution is a novel algorithm to calibrate the uncertainty in the surrogate model to the discrepancy between the true pressure solution of Darcy’s equation and the numerical solution. Finally, although our method is derived for building a surrogate for the solution of Darcy’s equation with a random permeability field, the framework broadly applies to solutions of other partial differential equations with random coefficients.

54 ENVIRONMENTAL SCIENCES↗

Equation of state of boron carbide B 4 ⁢C

We present the results of recent experiments conducted on the Sandia Z machine and a new tabular equation of state for B 4 ⁢C. The equation of state was calibrated to a combination of density functional calculations reported here and fits to preexisting data. It was constructed partly to recover the effects of a shock-driven, polymorphic phase transition of unknown character beginning at particle velocities of just under 3 km/s (shock pressures of 95 GPa). Some of the Z experiments included sound speeds determined by the overtaking rarefaction method, from which we calculate the Grüneisen parameter and compare with previous experiments conducted at the OMEGA laser [Fratanduono et al ., Phys. Rev. B 94 , 184107 (2016)], our own first principles calculations, and another recent tabular equation of state [Zhang et al ., Phys. Rev. E 102 , 053203 (2020)]. We also compare our results with previous static compression, thermophysical, and melt studies, finding mixed consistency. We predict the onset and completion of shock melting at 225 and 265 GPa, respectively, and predict a melt curve that is largely flat to pressures of several hundred GPa.

36 MATERIALS SCIENCE↗

Predicting variations of the least principal stress with depth: Application to unconventional oil and gas reservoirs using a log-based viscoelastic stress relaxation model

Knowledge of layer-to-layer variations of the least principal stress, S hmin , with depth is essential for optimization of multi-stage hydraulic fracturing in unconventional reservoirs. Utilizing a geomechanical model based on viscoelastic stress relaxation in relatively clay rich rocks, we present a new method for predicting continuous S hmin variations with depth. The method utilizes geophysical log data and S hmin measurements from routine diagnostic fracture injection tests (DFITs) at several depths for calibration. We consider a case study in the Wolfcamp formation in the Midland Basin, where both geophysical logs and values of S hmin from DFITs are available. We compute a continuous stress profile as a function of the well logs that fits all of the DFITs well. We utilized several machine learning technologies, such as bootstrap aggregation (or bagging), to improve the generalization of the model and demonstrate that the excellent fit between predicted and observed stress values is not the result of over-fitting the calibration points. The model is then validated by accurately predicting hold-out stress measurements from four wells within the study area and, without recalibration, accurately predicting stress as a function of depth in an offset pad about 6 miles away.

58 GEOSCIENCES↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Bayesian Approach to Regional Decadal Predictability: Sparse Parameter Estimation in High-Dimensional Linear Inverse Models of High-Latitude Sea Surface Temperature Variability

Stochastic reduced models are an important tool in climate systems whose many spatial and temporal scales cannot be fully discretized or underlying physics may not be fully accounted for. One form of reduced model, the linear inverse model (LIM), has been widely used for regional climate predictability studies—typically focusing more on tropical or midlatitude studies. However, most LIM fitting techniques rely on point estimation techniques deriving from fluctuation–dissipation theory. In this methodological study we explore the use of Bayesian inference techniques for LIM parameter estimation of sea surface temperature (SST), to quantify the skillful decadal predictability of Bayesian LIM models at high latitudes. We show that Bayesian methods, when compared to traditional point estimation methods for LIM-type models, provide better calibrated probabilistic skill, while simultaneously providing better point estimates due to the regularization effect of the prior distribution in high-dimensional problems. We compare the effect of several priors, as well as maximum likelihood estimates, on 1) estimating parameter values on a perfect model experiment and 2) producing calibrated 1-yr SST anomaly forecast distributions using a preindustrial control run of the Community Earth System Model (CESM). Finally, we employ a host of probabilistic skill metrics to determine the extent to which an LIM can forecast SST anomalies at high latitudes. We find that the choice of prior distribution has an appreciable impact on estimation outcomes, and priors that emphasize physically relevant properties enhance the model’s ability to capture variability of SST anomalies.

54 ENVIRONMENTAL SCIENCES↗

The Simons Observatory: Beam Characterization for the Small Aperture Telescopes

Abstract We use time-domain simulations of Jupiter observations to test and develop a beam reconstruction pipeline for the Simons Observatory Small Aperture Telescopes. The method relies on a mapmaker that estimates and subtracts correlated atmospheric noise and a beam fitting code designed to compensate for the bias caused by the mapmaker. We test our reconstruction performance for four different frequency bands against various algorithmic parameters, atmospheric conditions, and input beams. We additionally show the reconstruction quality as a function of the number of available observations and investigate how different calibration strategies affect the beam uncertainty. For all of the cases considered, we find good agreement between the fitted results and the input beam model within an ∼1.5% error for a multipole range ℓ = 30–700 and an ∼0.5% error for a multipole range ℓ = 50–200. We conclude by using a harmonic-domain component separation algorithm to verify that the beam reconstruction errors and biases observed in our analysis do not significantly bias the Simons Observatory r -measurement

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Current interrupt method for calculating the electrochemical impedance in a solid oxide electrolysis stack

Here, in this work the time domain response of Solid Oxide Electrolysis Cells (SOEC) to a current interruption was transformed into the frequency domain using a carrier function Laplace transform, which is fit to the experimental data using a MATLAB Complex Nonlinear Least Squares (CNLS) solver. The hardware implementation, consisting principally of a high-speed switch and a fast-logging Analog to Digital Converter (ADC), was assembled and tested using a calibration module to assess the accuracy, repeatability, and speed of acquisition of the prototype device as compared against a calibrated commercial impedance spectrometer. Additionally, the current interrupt device and commercial FRA were used to acquire the impedance spectra of a four cell SOEC stack with a large, 300 cm 2 , active cell area.

SOEC↗

An integrated approach to derive relative permeability from capillary pressure

Surface tension affects all aspects of fluid flow in porous media. Through measurements of surface tension interaction under multiphase conditions, a relative permeability curve can be determined. Relative permeability is a numerical description of the interaction between two or more fluids and the porous media. It is a critical parameter for various tools that characterize subsurface multiphase flow systems, such as numerical simulation for carbon sequestration, oil and gas development, and groundwater contamination remediation. Therefore, it is critical to get a good statistical distribution of relative permeability in the porous media under study. Empirical formula for determining relative permeability from capillary pressure are already well established but do not provide the needed flexibility that is required to match laboratory-derived relative permeability curves. By expanding the existing methods for calculating relative permeability from capillary pressure data, it is possible to create both two and three-phase relative permeability curves. Mercury intrusion capillary pressure (MICP) data from the Morrow 'B' Sandstone coupled with interfacial tension and contact angle measurements were used to create a suite of relative permeability curves. Furthermore, these curves were then calibrated to a small sample of existing laboratory curves to elucidate common fitting parameters for the formation that were then used to create relative permeability curves from MICP data that does not have an associated laboratory-measured relative permeability curve.

58 GEOSCIENCES↗

Calibration of CDM-Based Creep Constitutive Model Using Accelerated Creep Test (ACT) Data

In conventional creep testing (CCT) a specimen is subject to constant load and temperature for a long-duration until creep rupture occurs. Conventional testing can be costly when considering the number of experiments needed to characterize the creep response of a material over a range of stress and temperature. To predict long-term creep-rupture properties, the time-temperature-stress superposition principle (TTSSP) approach has been employed where stress and/or temperature is applied at an elevated level; the result of which are extrapolated down to low stress and/or temperature conditions. These methods have been successful in predicting minimum-creep-strain-rate (MCSR) and stress-rupture (SR) but suffer from an inability to predict the creep deformation curve or account for changes in deformation mechanisms or aging that occurs at long-duration. An accelerated technique, termed the Stepped isostress method (SSM) allows the accelerated testing of materials to determine their creep deformation response. Unlike TTSSP tests, the SSM test employs a single specimen where the stress is periodically step increased until rupture. The SSM creep deformation curve is processed (time and strain shifted) to produce an accelerated creep deformation curve that represent the creep deformation curve at the initial stress level in SSM. A processing procedure for metals has yet to be developed. The research objective of this study is to develop a processing procedure for SSM test data using a creep-damage constitutive model. Triplicate SSM tests were conducted on Ni-based superalloy Inconel 718 at 650°C with stress being periodically increased until rupture. Triplicate CCT tests were conducted at the initial stress level of the SSM tests. The Sine-hyperbolic (Sinh) creep-damage model was employed in this study. The Sinh creep-damage constitutive model is based on coupled creep strain rate and damage evolution equations; where both rates are dependent on the current state of damage. Calibration is two-step: analytical and numerical optimization. Each stepped creep deformation curve is tackled quasi-analytically to determine MCSR and SR related material constants and accumulated damage. The damage accumulated at the end of each step was then passed onto subsequent steps to calibrate the MCSR, rupture prediction, and damage evolution. Numerical optimization was applied to optimize model constants involved in the creep strain constitutive equations in order to generate best-fitted Sinh creep deformation curves. The Sinh model predictions were compared to the SSM and CCT data. The Sinh model satisfactorily predicts the SSM data and thus the calibrated material constants provides a good estimate of rupture found in the CCT data. Calibration using SSM data reduces the number of tests needed to calibrate a model; significantly reducing costs. A single SSM test replaces numerous creep tests at different stresses.

36 MATERIALS SCIENCE↗