Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building fault detection and diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

85 records · Page 5

Model-Based Diagnosis and Prognosis of a Water Recycling System

A water recycling system (WRS) deployed at NASA Ames Research Center s Sustainability Base (an energy efficient office building that integrates some novel technologies developed for space applications) will serve as a testbed for long duration testing of next generation spacecraft water recycling systems for future human spaceflight missions. This system cleans graywater (waste water collected from sinks and showers) and recycles it into clean water. Like all engineered systems, the WRS is prone to standard degradation due to regular use, as well as other faults. Diagnostic and prognostic applications will be deployed on the WRS to ensure its safe, efficient, and correct operation. The diagnostic and prognostic results can be used to enable condition-based maintenance to avoid unplanned outages, and perhaps extend the useful life of the WRS. Diagnosis involves detecting when a fault occurs, isolating the root cause of the fault, and identifying the extent of damage. Prognosis involves predicting when the system will reach its end of life irrespective of whether an abnormal condition is present or not. In this paper, first, we develop a physics model of both nominal and faulty system behavior of the WRS. Then, we apply an integrated model-based diagnosis and prognosis framework to the simulation model of the WRS for several different fault scenarios to detect, isolate, and identify faults, and predict the end of life in each fault scenario, and present the experimental results.

Roychoudhury, Indranil↗

StarPlan: A model-based diagnostic system for spacecraft

The Sunnyvale Division of Ford Aerospace created a model-based reasoning capability for diagnosing faults in space systems. The approach employs reasoning about a model of the domain (as it is designed to operate) to explain differences between expected and actual telemetry; i.e., to identify the root cause of the discrepancy (at an appropriate level of detail) and determine necessary corrective action. A development environment, named Paragon, was implemented to support both model-building and reasoning. The major benefit of the model-based approach is the capability for the intelligent system to handle faults that were not anticipated by a human expert. The feasibility of this approach for diagnosing problems in a spacecraft was demonstrated in a prototype system, named StarPlan. Reasoning modules within StarPlan detect anomalous telemetry, establish goals for returning the telemetry to nominal values, and create a command plan for attaining the goals. Before commands are implemented, their effects are simulated to assure convergence toward the goal. After the commands are issued, the telemetry is monitored to assure that the plan is successful. These features of StarPlan, along with associated concerns, issues and future directions, are discussed.

Heher, Dennis↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gray-Box Fault Models and Applications for Low-Carbon Emission CO 2 Refrigeration Systems

CO 2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. This study investigated five common faults for supermarket transcritical CO 2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Cell degradation quantification—a performance metric-based approach

A safe and reliable battery operation needs effective diagnostic tools. A quantitative failure analysis (FA) to enable cell qualification and quantify its effectiveness for reliable and safe operation of rechargeable Li batteries (RLB) is shown here. The method can identify and quantify potential failure based on the state of charge (SOC) under any operating conditions. A precise and accurate electrochemical analytic diagnosis (eCAD) of 14 rechargeable Li || NMC622 cells of the same build are used as an example. The FA by eCAD can quantitatively decipher good, bad and ugly cells in cycle aging. The cell qualification is based on thermodynamic SOC, not experimental conditions. The method provides a quantitative failure mode and effect analysis (FMEA) to reveal diverse “dead Li” formation that affects the reversibility of the Li anode and charge retention in the cell. This cell qualification method highlights the potential to improve cell quality for safe operation, with strong implications for early fault detection, FA, risk mitigation, state estimation and life prediction for reliable and safe RLB operations

25 ENERGY STORAGE↗

Propulsion IVHM Technology Experiment

The Propulsion IVHM Technology Experiment (PITEX) successfully demonstrated real-time fault detection and isolation of a virtual reusable launch vehicle (RLV) main propulsion system (MPS). Specifically, the PITEX research project developed and applied a model-based diagnostic system for the MPS of the X-34 RLV, a space-launch technology demonstrator. The demonstration was simulation-based using detailed models of the propulsion subsystem to generate nominal and failure scenarios during captive carry, which is the most safety-critical portion of the X-34 flight. Since no system-level testing of the X-34 Main Propulsion System (MPS) was performed, these simulated data were used to verify and validate the software system. Advanced diagnostic and signal processing algorithms were developed and tested in real time on flight-like hardware. In an attempt to expose potential performance problems, the PITEX diagnostic system was subjected to numerous realistic effects in the simulated data including noise, sensor resolution, command/valve talkback information, and nominal build variations. In all cases, the PITEX system performed as required. The research demonstrated potential benefits of model-based diagnostics, defined performance metrics required to evaluate the diagnostic system, and studied the impact of real-world challenges encountered when monitoring propulsion subsystems.

Chicatelli, Amy K.↗

Inductive System Monitors Tasks

The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of the actual failure event. In the Aeronautics Research Mission Directorate, IMS successfully performed real-time engine health analysis. IMS was able to detect simulated failures and actual engine anomalies in an F/A-18 aircraft during the course of 25 test flights. IMS is also being used in colla

Source record↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model↗

Advanced Diagnostic and Prognostic Testbed (ADAPT) Testability Analysis Report

As system designs become more complex, determining the best locations to add sensors and test points for the purpose of testing and monitoring these designs becomes more difficult. Not only must the designer take into consideration all real and potential faults of the system, he or she must also find efficient ways of detecting and isolating those faults. Because sensors and cabling take up valuable space and weight on a system, and given constraints on bandwidth and power, it is even more difficult to add sensors into these complex designs after the design has been completed. As a result, a number of software tools have been developed to assist the system designer in proper placement of these sensors during the system design phase of a project. One of the key functions provided by many of these software programs is a testability analysis of the system essentially an evaluation of how observable the system behavior is using available tests. During the design phase, testability metrics can help guide the designer in improving the inherent testability of the design. This may include adding, removing, or modifying tests; breaking up feedback loops, or changing the system to reduce fault propagation. Given a set of test requirements, the analysis can also help to verify that the system will meet those requirements. Of course, a testability analysis requires that a software model of the physical system is available. For the analysis to be most effective in guiding system design, this model should ideally be constructed in parallel with these efforts. The purpose of this paper is to present the final testability results of the Advanced Diagnostic and Prognostic Testbed (ADAPT) after the system model was completed. The tool chosen to build the model and to perform the testability analysis with is the Testability Engineering and Maintenance System Designer (TEAMS-Designer). The TEAMS toolset is intended to be a solution to span all phases of the system, from design and development through health management and maintenance. TEAMS-Designer is the model-building and testability analysis software in that suite.

Ossenfort, John↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software Testbed for Developing and Evaluating Integrated Autonomous Subsystems

To implement fault tolerant autonomy in future space systems, it will be necessary to integrate planning, adaptive control, and state estimation subsystems. However, integrating these subsystems is difficult, time-consuming, and error-prone. This paper describes Intelliface/ADAPT, a software testbed that helps researchers develop and test alternative strategies for integrating planning, execution, and diagnosis subsystems more quickly and easily. The testbed's architecture, graphical data displays, and implementations of the integrated subsystems support easy plug and play of alternate components to support research and development in fault-tolerant control of autonomous vehicles and operations support systems. Intelliface/ADAPT controls NASA's Advanced Diagnostics and Prognostics Testbed (ADAPT), which comprises batteries, electrical loads (fans, pumps, and lights), relays, circuit breakers, invertors, and sensors. During plan execution, an experimentor can inject faults into the ADAPT testbed by tripping circuit breakers, changing fan speed settings, and closing valves to restrict fluid flow. The diagnostic subsystem, based on NASA's Hybrid Diagnosis Engine (HyDE), detects and isolates these faults to determine the new state of the plant, ADAPT. Intelliface/ADAPT then updates its model of the ADAPT system's resources and determines whether the current plan can be executed using the reduced resources. If not, the planning subsystem generates a new plan that reschedules tasks, reconfigures ADAPT, and reassigns the use of ADAPT resources as needed to work around the fault. The resource model, planning domain model, and planning goals are expressed using NASA's Action Notation Modeling Language (ANML). Parts of the ANML model are generated automatically, and other parts are constructed by hand using the Planning Model Integrated Development Environment, a visual Eclipse-based IDE that accelerates ANML model development. Because native ANML planners are currently under development and not yet sufficiently capable, the ANML model is translated into the New Domain Definition Language (NDDL) and sent to NASA's EUROPA planning system for plan generation. The adaptive controller executes the new plan, using augmented, hierarchical finite state machines to select and sequence actions based on the state of the ADAPT system. Real-time sensor data, commands, and plans are displayed in information-dense arrays of timelines and graphs that zoom and scroll in unison. A dynamic schematic display uses color to show the real-time fault state and utilization of the system components and resources. An execution manager coordinates the activities of the other subsystems. The subsystems are integrated using the Internet Communications Engine (ICE). an object-oriented toolkit for building distributed applications.

Testbed↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗