Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “buffer gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Effect of Gravity Axis Orientation on the Growth of Phthalocyanine Thin Films

Experimentally, many of the functions of electrical circuits have been demonstrated using optical circuits and, in theory, all of these functions may be accomplished using optical devices made of nonlinear optical materials. Actual construction of nonlinear optical devices is one of the most active areas in all optical research being done at this time. Physical vapor transport (PVT) is a promising technique for production of thin films of a variety of organic and inorganic materials. Film optical quality, orientation of microcrystals, and thickness depends critically on type of material, pressure of buffer gas and temperature of deposition. An important but understudied influence on film characteristics is the effect of gravity-driven buoyancy. Frazier, Hung, Paley, Penn and Long have recently reported mathematical modelling of the vapor deposition process and tested the predictions of the model on the thickness of films grown by PVT of 6-(2-methyl-4-nitroanilino)-2,4-hexadiyn-l-ol (DAMNA). In an historic experiment, Debe, et. al. offered definitive proof that copper phthalocyanine films grown in a low gravity environment are denser and more ordered than those grown at 1 g. This work seeks to determine the influence on film quality of gravity driven buoyancy in the low pressure PVT film growth of metal-free phthalocyanine.

Pearson, Earl F.↗

Laser Induced Optical Pumping Measurements of Cross Sections for Fine and Hyperfine Structure Transitions in Sodium Induced by Collisions with Helium Argon Atoms

Optical pumping of the ground states of sodium can radically alter the shape of the laser induced fluorescence excitation spectrum, complicating measurements of temperature, pressure, etc., which are based on these spectra. Modeling of the fluorescence using rate equations for the eight hyperfine states of the sodium D manifolds can be used to quantify the contribution to the ground state pumping of transitions among the hyperfine excited states induced by collisions with buffer gas atoms. This model is used here to determine, from the shape of experimental spectra, cross sections for (Delta)F transitions of the P(sub 3/2) state induced by collisions with helium and argon atoms, for a range of values assumed for the P(sub 1/2), (Delta)F cross sections. The hyperfine cross sections measured using this method, which is thought to be novel, are compared with cross sections for transitions involving polarized magnetic substates, m(sub F), measured previously using polarization sensitive absorption. Also, fine structure transition ((Delta)J) cross sections were measured in the pumped vapor, giving agreement with previous measurements made in the absence of pumping.

Dobson, Chris C.↗

Laser-Induced Optical Pumping Measurements of Cross Section for Fine- and Hyperfine-Structure Transitions in Sodium Induced by Collisions with Helium and Argon Atoms

Optical pumping of the ground states of sodium can radically alter the shape of the laser-induced fluorescence excitation spectrum, complicating measurements of temperature, pressure, etc., which are based on these spectra. Modeling of the fluorescence using rate equations for the eight hyperfine states of the sodium D manifolds can be used to quantify the contribution to the ground state pumping of transitions among the hyperfine excited states induced by collisions with buffer gas atoms. This model is used here to determine, from the shape of experimental spectra, cross sections lor DELTA.F transitions of the P(sub 3/2) state induced by collisions with helium and argon atoms, for a range of values assumed for the P(sub 1/2), DELTA.F cross sections. The hyperfine cross sections measured using this method, which to our knowledge is novel, are compared with cross sections for transitions involving polarized magnetic substates m(sub F) measured previously using polarization sensitive absorption. Also, fine-structure transition cross sections were measured in the pumped vapor, giving agreement with previous measurements made in the absence of pumping.

Dobson, Chris C.↗

Short Duration Base Heating Test Improvements

Significant improvements have been made to a short duration space launch vehicle base heating test technique. This technique was first developed during the 1960's to investigate launch vehicle plume induced convective environments. Recent improvements include the use of coiled nitrogen buffer gas lines upstream of the hydrogen / oxygen propellant charge tubes, fast acting solenoid valves, stand alone gas delivery and data acquisition systems, and an integrated model design code. Technique improvements were successfully demonstrated during a 2.25% scale X-33 base heating test conducted in the NASA/MSFC Nozzle Test Facility in early 1999. Cost savings of approximately an order of magnitude over previous tests were realized due in large part to these improvements.

Bender, Robert L.↗

Efficient Quenching of Population Trapping in Excited Yb(+)

We report on a study to determine the efficiency of various buffer gases in quenching the population trapping states of laser-excited ytterbium ions. The ions were confined in an rf-dc hybrid trap, and their (2)S(.5) left and right arrow (2)P(3/2) transition was excited with 329-nm laser light. Buffer gases used include H2, N2, CO2, Ar, and He at several different pressure regimes. We have identified N2 to be highly efficient in quenching the population of the trapping states and thus be the most suitable buffer gas to use with ytterbium for the development of a trapped-ion microwave frequency standard.

Seidel, D. J.↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Performance of Adsorption - Based CO2 Acquisition Hardware for Mars ISRU

Chemical processing of the dusty, low-pressure Martian atmosphere typically requires conditioning and compression of the gases as first steps. A temperature-swing adsorption process can perform these tasks using nearly solid-state hardware and with relatively low power consumption compared to alternative processes. In addition, the process can separate the atmospheric constituents, producing both pressurized CO2 and a buffer gas mixture of nitrogen and argon. To date we have developed and tested adsorption compressors at scales appropriate for the near-term robotic missions that will lead the way to ISRU-based human exploration missions. In this talk we describe the characteristics, testing, and performance of these devices. We also discuss scale-up issues associated with meeting the processing demands of sample return and human missions.

Finn, John E.↗

Continuous Processing With Mars Gases

Current Martian missions call for the production of oxygen for breathing, and fuel and oxygen for propulsion to be produced from atmospheric carbon dioxide (CO2). Adsorption and freezing are the two methods considered for capturing CO2 from the atmosphere. However, the nitrogen (N2) and argon (Ar), which make up less than 5 percent of the atmosphere, cause difficulties with both of these processes by blocking the CO2. This results in the capture process rapidly changing from a pressure driven process to a diffusion controlled process. To increase the CO2 capture rates, some type of mechanical pump is usually proposed to remove the N2 and Ar. The N2 and Ar are useful and have been proposed for blanketing and pressurizing fuel tanks and as buffer gas for breathing air for manned missions. Separation of the Martian gases with the required purity can be accomplished with a combination of membranes. These membrane systems do not require a high feed pressure and provide suitable separation. Therefore, by use of the appropriate membrane combination with the Martian atmosphere supplied by a compressor a continuous Supply Of CO2 for fuel and oxygen production can be supplied. This phase of our program has focused on the selection of the membrane system. Since permeation data for membranes did not exist for Martian atmospheric pressures and temperatures, this information had to be compiled. The general trend as the temperature was lowered was for the membranes to become more selective. In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar. This paper will present the membrane data, provide the design requirements for a compressor, and compare the results with adsorption and freezer methods.

Parrish, Clyde↗

Continuous Processing with Mars Gases

Current Martian missions call for the production of oxygen for breathing, and fuel and oxygen for propulsion to be produced from atmospheric carbon dioxide (CO2). Adsorption and freezing are the two methods considered for capturing CO, from the atmosphere. However, the nitrogen (N2) and argon (Ar), which make up less than 5 percent of the atmosphere, cause difficulties with both of these processes by blocking the CO2, This results in the capture process rapidly changing from a pressure driven process to a diffusion controlled process. To increase the CO, capture rates, some type of mechanical pump is usually proposed to remove the N2 and Ar. The N2 and Ar are useful and have been proposed for blanketing and pressurizing fuel tanks and as buffer gas for breathing air for manned missions. Separation of the Martian gases with the required purity can be accomplished with a combination of membranes. These membrane systems do not require a high feed pressure and provide suitable separation. Therefore, by use of the appropriate membrane combination with the Martian atmosphere supplied by a compressor a continuous supply of CO2 for fuel and oxygen production can be supplied. This phase of our program has focused on the selection of the membrane system. Since permeation data for membranes did not exist for Martian atmospheric pressures and temperatures, this information had to be compiled. The general trend as the temperature was lowered was for the membranes to become more selective. In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar. This paper will present the membrane data, provide the design requirements for a compressor, and compare the results with adsorption and freezer methods.

Parrish, Clyde↗

Real-Time Quantitative Analysis of H2, He, O2, and Ar by Quadrupole Ion Trap Mass Spectrometry

The use of a quadrupole ion trap mass spectrometer for quantitative analysis of hydrogen and helium as well as other permanent gases is demonstrated. The customized instrument utilizes the mass selective instability mode of mass analysis as with commercial instruments; however, this instrument operates at a greater RF trapping frequency and without a buffer gas. With these differences, a useable mass range from 2 to over 50 Da is achieved, as required by NASA for monitoring the Space Shuttle during a launch countdown. The performance of the ion trap is evaluated using part-per-million concentrations of hydrogen, helium, oxygen and argon mixed into a nitrogen gas stream. Relative accuracy and precision when quantitating the four analytes were better than the NASA-required minimum of 10% error and 5% deviation, respectively. Limits of detection were below the NASA requirement of 25-ppm hydrogen and 100-ppm helium; those for oxygen and argon were slightly higher than the requirement. The instrument provided adequate performance at fast data recording rates, demonstrating the utility of an ion trap mass spectrometer as a real-time quantitative monitoring device for permanent gas analysis.

Ottens, Andrew K.↗

Electron Density and Two-Channel Neutron Emission Measurements in Steady-State Spherical Inertial-Electrostatically Confined Plasmas, with Review of the 1-D Kinetic Model

Electron density measurements have been made in steady-state plasmas in a spherical inertial electrostatic confinement (IEC) discharge using microwave interferometry. Plasma cores interior to two cathodes, having diameters of 15 and 23 cm, respectively, were probed over a transverse range of 10 cm with a spatial resolution of about 1.4 cm for buffer gas pressures from 0.2 to 6 Pa in argon and deuterium. The transverse profiles are generally flat, in some cases with eccentric symmetric minima, and give mean densities of from approx. = 0.4 to 7x 10(exp 10)/cu cm, the density generally increasing with the neutral gas pressure. Numerical solutions of the 1-D Poisson equation for EC plasmas are reviewed and energy distribution functions are identified which give flat transverse profiles. These functions are used with the plasma approximation to obtain solutions which also give densities consistent with the measurements, and a double potential well solution is obtained which has minima qualitatively similar to those observed. Explicit consideration is given to the compatibility of the solutions interior and exterior to the cathode, and to grid transparency. Deuterium fusion neutron emission rates were also measured and found to be isotropic, to within the measurement error, over two simultaneous directions. Anisotropy was observed in residual emissions during operation with non-fusing hydrogen-1. The deuterium rates are consistent with predictions from the model.

Dobson, Chris C.↗

Electron Density and Two-Channel Neutron Emission Measurements in Steady-State Spherical Inertial-Electrostatically Confined Plasmas, with Review of the One-Dimensional Kinetic Model

Electron density measurements have been made in steady-state plasmas in a spherical inertial electrostatic confinement (IEC) discharge using microwave interferometry. Plasma cores interior to two cathodes, having diameters of 15 and 23 cm, respectively, were probed over a transverse range of 10 cm with a spatial resolution of about 1.4 cm for buffer gas pressures from 0.2 to 6 Pa in argon and deuterium. The transverse profiles are generally flat, in some cases with eccentric symmetric minima, and give mean densities of from approx. = 0.4 to 7 x 10(exp 10)/cu cm, the density generally increasing with the neutral gas pressure. Numerical solutions of the one-dimensional Poisson equation for IEC plasmas are reviewed and energy distribution functions are identified which give flat transverse profiles. These functions are used with the plasma approximation to obtain solutions which also give densities consistent with the measurements, and a double potential well solution is obtained which has minima qualitatively similar to those observed. Explicit consideration is given to the compatibility of the solutions interior and exterior to the cathode, and to grid transparency. Deuterium fusion neutron emission rates were also measured and found to be isotropic, to within the measurement error, over two simultaneous directions. Anisotropy was observed in residual emissions during operation with nonfusing hydrogen- 1. The deuterium rates are consistent with predictions from the model.

Dobson, Chris C.↗

Separation of Carbon Monoxide and Carbon Dioxide for Mars ISRU

The atmosphere of Mars has many resources that can be processed to produce things such as oxygen, fuel, buffer gas, and water for support of human exploration missions. Successful manipulation of these resources is crucial for safe, cost-effective, and self-sufficient long-term human exploration of Mars. In our research, we are developing enabling technologies that require fundamental knowledge of adsorptive gas storage and separation processes. In particular, we are designing and constructing an innovative, low mass, low power separation device to recover carbon dioxide and carbon monoxide for Mars ISRU (in-situ resource utilization). The technology has broad implications for gas storage and separations for gas-solid systems that are ideally suited for reduced gravitational environments. This paper describes our separation process design and experimental procedures and reports results for the separation of CO2 and CO by a four-step adsorption cycle.

Walton, Krista S.↗

Wavelengths, f-Values, and Cross Sections in the UV Spectra of Astrophysical, Atoms, Ions, and Molecules

Data analysis for Fe III was completed in 2004. The new spectra give wavelengths and some energy levels for Fe III that are at least an order of magnitude more accurate than values in the literature. However, the data set is missing - because they are outside the wavelength range that we can study at Imperial College or with ancillary FT spectroscopy measurements at NIST - important transitions that would allow all energy levels to be determined with improved accuracy. We are assessing collaborations at other labs. We have made test runs with a number of cathodes (pure metals and alloys) in the Penning discharge source and selected four iron group (3d) elements, Cr, Mn, Co, and Ni, for further measurements. Cathodes of pure Cr and Co and an alloy of Ni were found to be best. Mn has not nm stably yet, and other cathode geometries or alloys may need to be assessed. Optimum Penning discharge (PD) lamp conditions (buffer gas, gas pressure, and current/voltage) were established for Co, and investigations are underway for Cr and Ni. Definitive measurements for Co await purchase of new mirrors and photomultiplier tubes that will improve signal to noise ratio. Our plan for the next year is to continue evaluating cathodes and operating conditions through March 05, and then to begin definitive measurements. The UV wavelength measurements made at Imperial College with the unique UV FT spectrometer will be complemented by visible and near IR range measurements at NIST in June and/or July. Approximately one year from now, we intend to visit Lund University to collaborate on lifetime measurements that will allow our branching ration data to be used to determine f-values.

Raymond, John C.↗

A parametric study of single-wall carbon nanotube growth by laser ablation

Results of a parametric study of carbon nanotube production by the double-pulse laser oven process are presented. The effect of various operating parameters on the production of single-wall carbon nanotubes (SWCNTs) is estimated by characterizing the nanotube material using analytical techniques, including scanning electron microscopy, transmission electron microscopy, thermo gravimetric analysis and Raman spectroscopy. The study included changing the sequence of the laser pulses, laser energy, pulse separation, type of buffer gas used, operating pressure, flow rate, inner tube diameter, as well as its material, and oven temperature. It was found that the material quality and quantity improve with deviation from normal operation parameters such as laser energy density higher than 1.5 J/cm2, pressure lower than 67 kPa, and flow rates higher than 100 sccm. Use of helium produced mainly small diameter tubes and a lower yield. The diameter of SWCNTs decreases with decreasing oven temperature and lower flow rates.

Nanotubes, Carbon/chemistry↗

Nanotube Activities at NASA-Johnson Space Center

Nanotube activities at NASA-Johnson Space Center include production, purification, characterization as well as applications of single wall carbon nanotubes (SWCNTs). A parametric study of the pulsed laser ablation process is recently completed to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Enhancement of production is achieved by rastering the graphite target and by increasing the target surface temperature with a cw laser. In-situ diagnostics during production included time resolved passive emission and laser induced fluorescence from the plume. The improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymer/nanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large Surface area as well as high electrical and thermal conductivity exhibited by SWCNTs. Comparison with existing technologies and possible future improvements in the SWCNT materials sill be presented.

Arepalli, Sivaram↗

Carbon Nanotube Activities at NASA-Johnson Space Center

Research activities on carbon nanotubes at NASA-Johnson Space Center include production, purification, characterization and their applications for human space flight. In-situ diagnostics during nanotube production by laser oven process include collection of spatial and temporal data of passive emission and laser induced fluorescence from C2, C3 and Nickel atoms in the plume. Details of the results from the "parametric study" of the pulsed laser ablation process indicate the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymednanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large surface area as well as high electrical and thermal conductivity exhibited by SWCNTs.

Arepalli, Sivaram↗