Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bolts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

In-service Oxidation and IASCC in High Fluence Baffle-Former Bolts Retrieved from a Westinghouse PWR

Baffle-former bolts (BFBs) are subjected to significant mechanical stress and neutron irradiation from the reactor core during the plant operation. Over the long operation period, these conditions lead to potential degradation and reduced load-carrying capacity of the bolts, and life extension of existing pressurized water reactors (PWRs) would only cause more damage to the bolt material. To this end, the Light Water Reactor Sustainability (LWRS) Program Materials Research Pathway (MRP) successfully harvested two high fluence BFBs from a Westinghouse two-loop downflow type PWR in 2016. In the same year, the two BFBs were received at the Westinghouse Churchill facility for inspection and specimen fabrication. The fabrication was completed in 2017 with specimens shipped to Oak Ridge National Laboratory (ORNL) for further testing. The objective of this project is to provide information that is integral to evaluating end of life microstructure and properties as a benchmark of international models developed for predicting radiation-induced swelling, segregation, precipitation, mechanical property degradation, and with the latest findings, susceptibility to irradiation-assisted stress corrosion cracking (IASCC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SEM/EBSD Characterization of Baffle-Former Bolts Designated for High Energy X-ray Microscopy Studies at the Advanced Photon Source

This report documents the microstructural and surface characterization of two high-fluence baffle-former bolts (BFBs) harvested from a commercial pressurized water reactor (PWR) after nearly four decades of service. These bolts experienced extreme conditions including high neutron fluence, elevated temperatures, corrosive primary water, and sustained mechanical loads, all of which contribute to degradation mechanisms such as irradiation-assisted stress corrosion cracking (IASCC). Using scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), the study assessed bulk and near-surface microstructures, grain boundary characteristics, and in-service oxide layers. The results revealed significant differences between bolts exposed to 41 dpa and 29 dpa, including differences in recrystallization extent, deformation structures, and oxidation morphology. These findings establish critical baseline data for integration with advanced synchrotron-based high-energy X-ray microscopy (HEXM) and computational crystal plasticity models. Ultimately, the work supports improved mechanistic understanding and predictive capability regarding the long-term performance of reactor core internal components.

Lach, Tim [Oak Ridge National Laboratory (ORNL), O↗

Mitigation of Galvanic Corrosion in Bolted Joint of AZ31B and Carbon Fiber-Reinforced Composite Using Polymer Insulation

The use of polymer insulation to mitigate galvanic corrosion was examined for bolted joints of AZ31B Mg alloy and carbon fiber-reinforced composite. To assess the corrosion behaviors of bolted joints with and without polymer insulation, solution immersion and salt spray exposure (ASTM B117) tests were conducted, and the corrosion depths and volumes were determined for the joint specimens after the tests. The polymer-insulated bolted joints exhibited much lower corrosion depths and volumes, highlighting the effective mitigation of galvanic corrosion. The reductions of joint strength in the post-corrosion joint specimens were relatively small (up to ~10%) in the polymer-insulated group but greater (up to 90%) in the group with no insulation. Cross-sectional characterization of post-corrosion joints with polymer insulation revealed local pits developed on AZ31B under galvanic influence, indicating that limited galvanic attack (that did not decrease the joining integrity significantly) could still occur during a long salt spray exposure (~1264 h) owing to the permeation of an aqueous corrosive medium.

36 MATERIALS SCIENCE↗

Fastener provides for bolt misalignment and quick release of flange

Fastener enables two large flanges to be bolted together without close alignment between the bolt and bolt-hole diameters, and provides for a quick release of one of the flanges under emergency conditions. It contains a nut that is retained by a square head in a recess in one side of the removable flange and by a collar and snap ring on the other side of the flange.

England, C.↗

Stress relaxation of high strength A-286 bolts in simulated storage at room temperature

It was concluded that thermally activated relaxation of the type customarily encountered at high temperatures was not expected to occur at the low temperatures where long time NERVA storage conditions will prevail. Instances where relaxation occurred by a different mechanism at such moderate temperatures were also reported. Twelve simulated bolted flange test specimens were prepared. Parameters that were varied among the twelve specimens were the flange material, the bolt shank diameter, and the bolt loading in terms of percent of yield strength.

Sampson, R. C.↗

Torquing preload in a lubricated bolt

The tension preload obtained by torquing a 7/8 in. diam UNC high strength bolt was determined for lubricated and dry conditions. Consistent preload with a variation of + or - 3% was obtained when the bolt head area was lubricated prior to each torque application. Preload tensions nearly 70% greater than the value predicted with the commonly used formula occurred with the lubricated bolt. A reduction to 39% of the initial preload was observed during 50 torque applications without relubrication. Little evidence of wear was noted after 203 cycles of tightening.

Seegmiller, H. L.↗

Space Shuttle orbiter separation bolts

Evolution of the space shuttle from previous spacecraft systems dictated growth and innovative design of previously standard ordnance devices. Initially, one bolt design was programmed for both 747 and external tank application. However, during development and subsequent analyses, two distinct designs evolved. The unique requirements of both bolts include: high combined loading, redundant initiation, flush separation plane, self-righting and shank attenuation. Of particular interest are the test methods, problem areas, and use of subscale models which demonstrated feasibility at an early phase in the program. The techniques incorporated in the shuttle orbiter bolts are applicable to other mechanisms.

Ritchie, R. S.↗

Preliminary bolted-joint data

Bolted-joint strength and failure modes for advanced graphite/polyimide composite laminates at 116K (-250 F), room temperature, and 589K (600 F) were determined to provide preliminary design data. The bolted-joint test setup for the low and elevated temperature tests is described. Test results are reported on a quasi-isotropic laminate of Celion 6000/PMR-15. Single bolt, double lap shear specimens were tested to obtain maximum joint strength and failure mode. The effect of joint geometry and temperature on joint strength and failure mode is presented.

Wichorek, G. R.↗

Bolt-bearing fatigue of a graphite/epoxy laminate

Graphite/epoxy laminates were tested under bolt-bearing loads for a range of bolt clampup torques and for several test conditions involving water. High clampup torque improved both the static strength and fatigue limit by about 100 percent compared to a simple pin-bearing case, which had no through-the-thickness constraint. The static strength improvement was explained in terms of failure modes. Bolt clampup also influenced the hole elongation that developed before failure. For both the static and fatigue tests, the hole elongations were much larger for the low-torque clampup. Tests in water degraded static bearing strength only slightly, but reduced the fatigue limit about 40 percent below that for tests conducted in air.

Crews, J. H., Jr.↗

Development of forward and aft separation bolts for the NASA Space Shuttle solid rocket booster separation system

A program is underway to design, develop, fabricate, and qualify large high-load forward and aft separation bolts for the Space Shuttle; the bolts will serve as attachment between two solid rocket boosters and the external tank. This paper reviews bolt development, with emphasis on the scaling of components, the use of high strength maraging steel for the internal components, and the use of lead as a hydraulic fluid.

Nein, H.↗

Strain-Gaged Bolts Are Easily Prepared

New method for installing strain gages in structural bolts is implemented as standard workbench procedure. Rather than potting gages in a hole along axis of bolt, gages are first installed on outside of plastic carrier tube. Tube is then epoxied in axial hole. Procedure can be used to prepare gages to monitor bolt tension, shear, or torsion.

Walker, R. L.↗

Safety Bolt Doubles as a Bushing-Removal Tool

Bushings fitted to close tolerances and limited access can be removed without damage to housing by using bolt with integrated locking dog. Such self-retaining positive - locking bolts are normally used as fasteners in critical joints where accidentally loosened bolt could cause damage or injuries.

Haverkamp, C. E.↗

Locking Nut and Bolt

Threaded fastener locks parts securely together despite together large loosening torques, even under conditions of high temperature and vibration. Positive locking action is suitable for use where conventional fasteners tend to work loose--for example, on high-speed rotating machinery. Bolt, nut and key are joined together so key occupies alined slots in bolt and nut and prevents nut from rotating off bolt.

Bishop, R.↗

Pulsed-echo interface wave characterization of bolted plates

Ultrasonic waves which propagate along the plane boundary separating two solid substrates were used to characterize aluminum and titanium plates adhesively bonded and bolted together. Wave pulses were used to produce interface waves between the aluminum and a Ti-6Al-4V titanium alloy bar by normal mode conversion. Interface wave reflections from bolt holes drilled through the interface were reconverted to surface wave pulses and detected by the same wedge by standard pulse-echo techniques. Time of flight measurements indicate that the reflected waves are a supersonic of longitudinal modes and circularly symmetric waves that propagate around the bolt hole.

Turner, T. M.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was developed for clampup force relaxation. This generalized equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well.

Shivakumar, K. N.↗

Bolt-bearing fatigue of a graphite/epoxy laminate

Graphite/epoxy laminates (T300/5208) were tested under bolt-bearing loads for a range of bolt clampup torques and for several test conditions involving water. High clampup torque improved both the static strength and fatigue limit by about 100 percent compared to a simple pin-bearing case, which had no through-the-thickness constraint. The static strength improvement was explained in terms of failure modes. Bolt clampup also influenced the hole elongation that developed before failure. For both the static and fatigue tests, the hole elongations were much larger for the low-torque-clampup case than for the pin-bearing case or for tests with moderate clampup torques. Tests in water degraded static bearing strength only slightly, but reduced the fatigue limit about 40 percent below that for tests conducted in air.

Crews, J. H., Jr.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well. Previously announced in STAR as N82-19320

Shivakumar, K. N.↗