Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bolt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Strain-Gaged Bolts Are Easily Prepared

New method for installing strain gages in structural bolts is implemented as standard workbench procedure. Rather than potting gages in a hole along axis of bolt, gages are first installed on outside of plastic carrier tube. Tube is then epoxied in axial hole. Procedure can be used to prepare gages to monitor bolt tension, shear, or torsion.

Walker, R. L.↗

Safety Bolt Doubles as a Bushing-Removal Tool

Bushings fitted to close tolerances and limited access can be removed without damage to housing by using bolt with integrated locking dog. Such self-retaining positive - locking bolts are normally used as fasteners in critical joints where accidentally loosened bolt could cause damage or injuries.

Haverkamp, C. E.↗

Locking Nut and Bolt

Threaded fastener locks parts securely together despite together large loosening torques, even under conditions of high temperature and vibration. Positive locking action is suitable for use where conventional fasteners tend to work loose--for example, on high-speed rotating machinery. Bolt, nut and key are joined together so key occupies alined slots in bolt and nut and prevents nut from rotating off bolt.

Bishop, R.↗

Pulsed-echo interface wave characterization of bolted plates

Ultrasonic waves which propagate along the plane boundary separating two solid substrates were used to characterize aluminum and titanium plates adhesively bonded and bolted together. Wave pulses were used to produce interface waves between the aluminum and a Ti-6Al-4V titanium alloy bar by normal mode conversion. Interface wave reflections from bolt holes drilled through the interface were reconverted to surface wave pulses and detected by the same wedge by standard pulse-echo techniques. Time of flight measurements indicate that the reflected waves are a supersonic of longitudinal modes and circularly symmetric waves that propagate around the bolt hole.

Turner, T. M.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was developed for clampup force relaxation. This generalized equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well.

Shivakumar, K. N.↗

Bolt-bearing fatigue of a graphite/epoxy laminate

Graphite/epoxy laminates (T300/5208) were tested under bolt-bearing loads for a range of bolt clampup torques and for several test conditions involving water. High clampup torque improved both the static strength and fatigue limit by about 100 percent compared to a simple pin-bearing case, which had no through-the-thickness constraint. The static strength improvement was explained in terms of failure modes. Bolt clampup also influenced the hole elongation that developed before failure. For both the static and fatigue tests, the hole elongations were much larger for the low-torque-clampup case than for the pin-bearing case or for tests with moderate clampup torques. Tests in water degraded static bearing strength only slightly, but reduced the fatigue limit about 40 percent below that for tests conducted in air.

Crews, J. H., Jr.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well. Previously announced in STAR as N82-19320

Shivakumar, K. N.↗

Stress analysis method for a clearance fit bolt under bearing loads

In the present, simple analysis method for bolt hole clearance stresses in mechanically fastened joints, an inverse formulation is used with a finite element analysis. Conditions along the bolt hole contact arc are specified by displacement constraint equations. The method was applied to a single fastener clearance-fit joint with typical clearance values, for the cases of a rigid, frictionless bolt and a quasi-isotropic graphite/epoxy laminate. Results indicate that the contact arc, as well as the peak stresses around the hole (and their locations), were strongly influenced by the clearance. After a minor initial nonlinearity, peak stresses varied linearly with applied load. Clearance levels are found to have only a minor influence on overall joint stiffness.

Crews, J. H., Jr.↗

Structural analysis of a bolted joint concept for the Space Shuttle's solid rocket motor casing

The Space Shuttle Challenger accident is thought to have been caused by the failure of one of the tang-clevis joints which join together the casing segments of the Solid Rocket Motors (SRM). Excessive displacement between the tang and clevis, possibly unseating the O-ring seals, may have initiated the resulting accident. An effort was undertaken at NASA's Langley Research Center to design an alternative concept for mating the casing segments. A bolted flanged joint concept was designed and analyzed to determine if the concept would effectively maintain a seal while minimizing joint weight and controlling stress levels. It is shown that under the loading condition analyzed the seal area of the joint remains seated. The only potential stress problem is a stress concentration in the flange at the edge of the bolt hole, which is highly localized. While heavier than the existing joint, this concept does have some advantages which make the bolted joint an attractive alternative.

Lindell, Michael C.↗

Structural analysis of a bolted joint concept for the space shuttle's solid rocket motor casing

The Space Shuttle Challenger accident is thought to have been caused by the failure of one of the tang-clevis joints joining together the casing segments of the Solid Rocket Motors (SRM). Excessive displacement between the tang and clevis, possibly unseating the O-ring seals, may have initiated the resulting accident. An effort was made at NASA Langley Research Center to design an alternative concept for mating the casing segments. A bolted flange joint concept was designed and analyzed to determine if the concept would effectively maintain a seal while minimizing joint weight and controlling stress levels. It is shown that under the loading conditions analyzed the seal area of the joint remains seated. The only potential stress problem is a stress concentration in the flange at the edge of the bolt hole, which is highly localized. While heavier than the existing joint, this concept does have some advantages making the bolted joint an attractive alternative.

Lindell, Michael C.↗

Simplified procedures for designing composite bolted joints

Simplified procedures are described to design and analyze single and multi-bolt composite joints. Numerical examples illustrate the use of these methods. Factors affecting composite bolted joints are summarized. References are cited where more detailed discussion is presented on specific aspects of composite bolted joints. Design variables associated with these joints are summarized in the appendix.

Chamis, Christos C.↗

Simplified procedures for designing composite bolted joints

Simplified procedures are described to design and analyze single and multi-bolt composite joints. Numerical examples illustrate the use of these methods. Factors affecting composite bolted joints are summarized. References are cited where more detailed discussion is presented on specific aspects of composite bolted joints. Design variables associated with these joints are summarized in the appendix.

Chamis, Christos C.↗

A microprocessor based portable bolt tension monitor

A bolt tension monitor (BTM) which uses ultrasonics and a pulsed phase locked loop circuit to measure load-induced acoustic phase shifts which are independent of friction is described. The BTM makes it possible to measure the load in a bolt that was tightened at some time in the past. This capability to recertify a load after-the-fact will help to insure the integrity of a bolted joint.

Perey, D. F.↗

Bolt-Tension Sensor

In technique for measuring tensile force of bolt, specially fabricated magnetostrictive washer used as force transducer. Compact, portable inductive electronic sensor placed against washer to measure tension force. New system provides accurate, economical, and convenient way to measure bolt tension in field. Measurements on test assembly shows that tension can be measured to accuracy of about plus or minus 1 percent of load capacity of typical bolt.

Goldie, James H.↗

Quick-Connect, Slow-Disconnect Bolt

Proposed bolt functions similarly to device described in article "Quick-Connect, Slow-Disconnect Nut" (MFS-28833). Bolt installed in standard threaded hole simply by pushing it into hole. Once inserted, bolt withdrawn only by turning it in conventional way.

Weddendorf, Bruce↗

Easing The Calculation Of Bolt-Circle Coordinates

Bolt Circle Calculation (BOLT-CALC) computer program used to reduce significant time consumed in manually computing trigonometry of rectangular Cartesian coordinates of holes in bolt circle as shown on blueprint or drawing. Eliminates risk of computational errors, particularly in cases involving many holes or in cases in which coordinates expressed to many significant digits. Program assists in many practical situations arising in machine shops. Written in BASIC. Also successfully compiled and implemented by use of Microsoft's QuickBasic v4.0.

Burley, Richard K.↗

Standard Methods for Bolt-Bearing Testing of Textile Composites

The response of three 2-D braided materials to bolt bearing loading was evaluated using data generated by Boeing Defense and Space Group in Philadelphia, PA. Three test methods, stabilized single shear, unstabilized single shear, and double shear, were compared. In general, these textile composites were found to be sensitive to bolt bearing test methods. The stabilized single shear method yielded higher strengths than the unstabilized single shear method in all cases. The double shear test method always produced the highest strengths but these results may be somewhat misleading. It is therefore recommended that standard material comparisons be made using the stabilized single shear test method. The effects of two geometric parameters, W/D and e/D, were also studied. An evaluation of the effect of the specimen width (W) to hole diameter (D) ratio concluded that bolt bearing responses were consistent with open hole tension results. A W/D ratio of 6 or greater should be maintained. The proximity of the hole to the specimen edge significantly affected strength. In all cases, strength was improved by increasing the ratio of the distance from the hole center to the specimen edge (e) to the hole diameter (D) above 2. An e/D ratio of 3 or greater is recommended.

Portanova, M. A.↗

Probabilistic Evaluation of Bolted Joints in Polymer Matrix Composites

Computational methods are described to probabilistically simulate fracture in bolted composite structures. Progressive fracture is simulated via an innovative approach independent of stress intensity factors and fracture toughness. The effect on structure damage of design variable uncertainties is quantified. The Fast Probability Integrator is used to assess the scatter in the composite structure response before and after damage. Sensitivity of the response to design variables is evaluated. The methods are demonstrated for bolted joint polymer matrix composite panels under end loads. The effects of fabrication process are included in the simulation of damage in the bolted panel. The results show that the most effective way to reduce the end displacement at fracture is to control the load and ply thickness.

Chamis, C. C.↗