Sensor Technology for Biomedical Applications
This presentation describes smart chemical gas species sensors technology for a variety of applications including smart sensor systems for human health breath monitoring applications.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation describes smart chemical gas species sensors technology for a variety of applications including smart sensor systems for human health breath monitoring applications.
Biomedical data were collected during high-G portions of 11 YF-16 test flights. Test pilots monitored revealed increased respiratory rate and volume, decreased tidal volume, and increased heart rate at higher G levels, with one pilot exhibiting various cardiac arrhythmias. Anti-G suit inflation and pressurization lags varied inversely with G-onset rate, and suit pressurization slope was near the design value.
Papers on issues related to Mars exploration are presented, covering topics such as the social implications of manned missions to Mars, mission strategies, mission designs, the economics of a Mars mission, Space Station support for a Mars mission, a Diagnostic and Environmental Monitoring System, and a zero-g CELSS/recreation facility for an earth/Mars crew shuttle. Other topics include biomedical concerns and fitness in spaceflight, spaceflight environment habitability, the Mars Rover/Sample Return Mission, a rooitic Mars surface sampler, a Mars Orbiter, and scientific goals of Mars exploration. Additional topics include Space Station evolution, mission options, modeling advanced space systems, computer support for Mars missions, launch system options, advanced propulsion techniques, the utilization of resources on Mars, the development of a Martian base, and options for mobility on Mars.
The SENSORS 2000! (S2K!) program at NASA's Ames Research Center is currently developing a biotelemetry system for monitoring pH and temperature in unrestrained subjects. This activity is part of a broader scope effort to provide an Advanced Biotelemetry System (ABTS) for use in future space life sciences research. Many anticipated research endeavors will require biomedical and biochemical sensors and related instrumentation to make continuous inflight measurements in a variable-gravity environment. Since crew time is limited, automated data acquisition, data processing, data storage, and subject health monitoring are required. An automated biochemical and physiological data acquisition system based on non invasive or implantable biotelemetry technology will meet these requirements. The ABTS will ultimately acquire a variety of physiological measurands including temperature, biopotentials (e.g. ECG, EEG, EMG, EOG), blood pressure, flow and dimensions, as well as chemical and biological parameters including pH. Development activities are planned in evolutionary, leveraged steps. Near-term activities include 1) development of a dual channel pH/temperature telemetry system, and 2) development of a low bandwidth, 4-channel telemetry system, that measures temperature, heart rate, pressure, and pH. This abstract describes the pH/temperature telemeter.
Conformable stress and strain sensors are required for monitoring the integrity of airframe structures as well as for sensing the mechanical stimuli in prosthetic arms. For this purpose, we have developed a series of piezoresistive single-wall carbon nanotube (SWCNT)/polymer nanocomposites. The electromechanical coupling of pressure with resistance changes in these nanocomposites is exceptionally greater than that of metallic piezoresistive materials. In fact, the piezoresistive stress coefficient (pi) of a SWCNT/polymer nanocomposite is approximately two orders of magnitude higher than that of a typical metallic piezoresistive. The piezoresistive stress coefficient is a function of the nanotube concentration wherein the maximum value occurs at a concentration just above the percolation threshold concentration (phi approx. 0.05 %). This response appears to originate from a change in intrinsic resistivity under compression/tension. A systematic study of the effect of the modulus of the polymer matrix on piezoresistivity allowed us to make flexible and conformable sensors for biomedical applications. The prototype haptic sensors using these nanocomposites are demonstrated. The piezocapacitive properties of SWCNT/polymer are also characterized by monitoring the capacitance change under pressure.
Space related biomedical research involving nonhuman primates is reviewed. The scientific assets of various species and the instruments used for monitoring physiological processes during long duration experimentations are described.
NASA uses areal bone mineral density (aBMD) by dual-energy X-ray absorptiometry (DXA) to monitor skeletal health in astronauts after typical 180-day spaceflights. The osteoporosis field and NASA, however, recognize the insufficiency of DXA aBMD as a sole surrogate for fracture risk. This is an even greater concern for NASA as it attempts to expand fracture risk assessment in astronauts, given the complicated nature of spaceflight-induced bone changes and the fact that multiple 1-year missions are planned. In the past decade, emerging analyses for additional surrogates have been tested in clinical trials; the potential use of these technologies to monitor the biomechanical integrity of the astronaut skeleton will be presented. OVERVIEW: An advisory panel of osteoporosis policy-makers provided NASA with an evidence-based assessment of astronaut biomedical and research data. The panel concluded that spaceflight and terrestrial bone loss have significant differences and certain factors may predispose astronauts to premature fractures. Based on these concerns, a proposed surveillance program is presented which a) uses Quantitative Computed Tomography (QCT) scans of the hip to monitor the recovery of spaceflight-induced deficits in trabecular BMD by 2 years after return, b) develops Finite Element Models [FEM] of QCT data to evaluate spaceflight effect on calculated hip bone strength and c) generates Trabecular Bone Score [TBS] from serial DXA scans of the lumbar spine to evaluate the effect of age, spaceflight and countermeasures on this novel index of bone microarchitecture. SIGNIFICANCE: DXA aBMD is a widely-applied, evidence-based predictor for fractures but not applicable as a fracture surrogate for premenopausal females and males <50 years. Its inability to detect structural parameters is a limitation for assessing changes in bone integrity with and without countermeasures. Collective use of aBMD, TBS, QCT, and FEM analysis for astronaut surveillance could accommodate NASA's aggressive schedule for risk definition and inform a NASA-developed model which assesses the probability of overloading bones during mechanically-loaded mission tasks and possibly for physical activities after return to Earth.
During missions to the Moon or Mars, the crew will need medical capabilities to diagnose and treat disease as well as for maintaining their health. The Exploration Medical Capability Element develops medical technologies, medical informatics, and clinical capabilities for different levels of care during space missions. The work done by team members in this Element is leading edge technology, procedure, and pharmacological development. They develop data systems that protect patient's private medical information, aid in the diagnosis of medical conditions, and act as a repository of relevant NASA life sciences experimental studies. To minimize the medical risks to crew health the physicians and scientists in this Element develop models to quantify the probability of medical events occurring during a mission. They define procedures to treat an ill or injured crew member who does not have access to an emergency room and who must be cared for in a microgravity environment where both liquids and solids behave differently than on Earth. To support the development of these medical capabilities, the Element manages the development of medical technologies that prevent, monitor, diagnose, and treat an ill or injured crewmember. The Exploration Medical Capability Element collaborates with the National Space Biomedical Research Institute (NSBRI), the Department of Defense, other Government-funded agencies, academic institutions, and industry.
My fall 2015 semester was spent at the Lyndon B. Johnson Space Center working in the Integrated Graphics, Operations, and Analysis Laboratory (IGOAL). My first project was to create a video animation that could tell the story of OMICS. OMICS is a term being used in the field of biomedical science to describe the collective technologies that study biological systems, such as what makes up a cell and how it functions with other systems. In the IGOAL I used a large 23 inch Wacom monitor to draw storyboards, graphics, and line art animations. I used Blender as the 3D environment to sculpt, shape, cut or modify the several scenes and models for the video. A challenge creating this video was to take a term used in biomedical science and describe it in such a way that an 8th grade student can understand. I used a line art style because it would visually set the tone for what we thought was an educational style. In order to get a handle on the perspective and overall feel for the animation without overloading my workspace, I split up the 2 minute animation into several scenes. I used Blender's python scripting capabilities which allowed for the addition of plugins to add or modify tools. The scripts can also directly interact with the objects to create naturalistic patterns or movements. After collecting the rendered scenes, I used Blender's built-in video editing workspace to output the animation. My second project was to write software that emulates a physical system's interface. The interface was to simulate a boat, ROV, and winch system. Simulations are a time and cost effective way to test complicated data and provide training for operators without having to use expensive hardware. We created the virtual controls with 3-D Blender models and 2-D graphics, and then add functionality in C# using the Unity game engine. The Unity engine provides several essential behaviors of a simulator, such as the start and update functions. A framework for Unity, which was developed in the lab, provided a way to place the different widgets on the virtual console dock and have them resize correctly based on the window dimensions.. My task in this project was to create the controls and visualizations for the data coming in from the simulator for the boat portion of the project. I wrote a class for each control window to handle the functionality of that widget. I implemented 11 widgets that make up the ship portion of the simulator. The members of the lab were each masters of their craft and I'm glad I had the opportunity to learn from them. I learned to plan strategically so I could finish this project on time. I allotted time for storyboarding, development, and refinement. In regards to animating I learned to use modifiers like lattice, boolean and build deformers. I also learned how to animate with drivers, how to use the dope sheet, and how to use the graph editor. In coding I learned to limit the chances for bugs by privatizing functions that should be exclusive to their class. I learned how to use the GIT repository to commit, stash and pull the latest build. I learned a bit of everything because I had the chance to see the entire application development process from the artwork, to the implementation.
Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.
Development of a temporal query framework for time-oriented medical databases has hitherto been a challenging problem. We describe a novel method for the detection of hemodynamic events in multiparameter trends utilizing wavelet coefficients in a MySQL relational database. Storage of the wavelet coefficients allowed for a compact representation of the trends, and provided robust descriptors for the dynamics of the parameter time series. A data model was developed to allow for simplified queries along several dimensions and time scales. Of particular importance, the data model and wavelet framework allowed for queries to be processed with minimal table-join operations. A web-based search engine was developed to allow for user-defined queries. Typical queries required between 0.01 and 0.02 seconds, with at least two orders of magnitude improvement in speed over conventional queries. This powerful and innovative structure will facilitate research on large-scale time-oriented medical databases.
Analog-to-digital computer accepts physiological flight data as three basic analog input signals - the ECG signal, the flowmeter signal which is a respiration monitor, and the accelerometer signal which measures the normal-g-load on the subject.
Method of automated, continuous monitoring to detect faults in complicated dynamic system based on hidden-Markov-model (HMM) approach. Simpler than another, recently proposed HMM method, but retains advantages of that method, including low susceptibility to false alarms, no need for mathematical model of dynamics of system under normal or faulty conditions, and ability to detect subtle changes in characteristics of monitored signals. Examples of systems monitored by use of this method include motors, turbines, and pumps critical in their applications; chemical-processing plants; powerplants; and biomedical systems.
Radiation is considered to be one of three or four major hazards for personnel in space and has emerged as the most critical issue to be resolved for long-term missions, both orbital and interplanetary. Space habitats are stressful and dangerous environments. Health and medical consequences arising from microgravity, stress, and trauma include weakened immune systems, increased viral activity, and loss of bone mass. The greatest risks from radiation are generally assumed to be cancers and possibly damage to the central nervous system. Synergistic effects arising from the other environmental hazards along with abscopal and exogenic factors are likely. Space programs represent an exceptional opportunity for examining the biological consequences of low-dose exposures of humans to radiation at every level of progression. Although astronauts are a relatively small population, they are healthy, physically active volunteers who undergo extensive testing and medical examinations before, during, and after protracted exposures with periodic follow-up examinations. The radiation environments along with other hazards are likewise monitored and documented. Extensive international research programs are in progress. Seven years ago the U.S. National Aeronautics and Space Administration established the National Space Biomedical Research Institute through a cooperative agreement with a consortium of research and academic institutions in order to address radiation issues through a concerted, programmatic effort. Advanced technologies are rapidly being incorporated into these programs to determine the significance of new biological data and to evaluate the interplay among the different medical hazards. Programmatic in vivo and in vitro studies of the processes leading to carcinogenesis are in progress. Drugs and dietary supplements are being examined at the cellular and in vivo levels to assess their potential as dose-modifying agents. The infrastructure of this new approach, recent results, and research in progress are reviewed and discussed.
The National Space Biomedical Research Institute, based in Houston and funded by NASA, began funding research for Harvard University researchers to design Palm software to help astronauts monitor and assess their cognitive functioning. The MiniCog Rapid Assessment Battery (MRAB) was licensed by the Criteria Corporation in Los Angeles and adapted for Web-based employment testing. The test battery assesses nine different cognitive functions and can gauge the effect of stress-related deficits, such as fatigue, on various tasks. The MRAB can be used not only for pre-employment testing but also for repeat administrations to measure day-to-day job readiness in professions where alertness is critical.
This custom bibliography from the NASA Scientific and Technical Information Program lists a sampling of records found in the NASA Aeronautics and Space Database. The scope of this topic includes space medicine, remote monitoring, diagnosis, and treatment. This area of focus is one of the enabling technologies as defined by NASA s Report of the President s Commission on Implementation of United States Space Exploration Policy, published in June 2004.
Treatment and prevention of the physiologic problems of spacecrews are discussed. Preflight procedures, inflight monitoring and medication, and postflight examination are described. Specific factors covered include: medical screening and astronaut selection; health stabilization and exposure prevention; preflight medical examinations and training; biomedical data; medical kits; diagnosis and treatment; and implications of postflight findings.
For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.