Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Aerospace reliability applied to biomedicine.

An analysis is presented that indicates that the reliability and quality assurance methodology selected by NASA to minimize failures in aerospace equipment can be applied directly to biomedical devices to improve hospital equipment reliability. The Space Electric Rocket Test project is used as an example of NASA application of reliability and quality assurance (R&QA) methods. By analogy a comparison is made to show how these same methods can be used in the development of transducers, instrumentation, and complex systems for use in medicine.

Lalli, V. R.↗

Removal of Biologically Active Organic Contaminants using Atomic Oxygen

Biomedical devices that are to come into contact with living tissue, such as prosthetic and other implants for the human body and the containers used to store and transport them, are together cleaned of non-living, but biologically active organic materials, including endotoxins such as lipopolysaccharides, and assembled into a hermetically sealed package without recontamination. This is achieved by cleaning both the device and package components together in an apparatus, which includes a hermetically sealed chamber, in which they are contacted with atomic oxygen which biocleans them, by oxidizing the biologically active organic materials. The apparatus also includes means for manipulating the device and container and hermetically sealing the cleaned device into the cleaned container to form the package. A calibrated witness coupon visually indicates whether or not the device and container have received enough exposure to the atomic oxygen to have removed the organic materials from their surfaces. Gamma radiation is then used to sterilize the device in the sealed container.

Bruce A Banks↗

The Validation of Vapor Phase Hydrogen Peroxide Microbial Reduction for Planetary Protection and a Proposed Vacuum Process Specification

The Jet Propulsion Laboratory, in conjunction with the NASA Planetary Protection Officer, has selected the vapor phase hydrogen peroxide sterilization process for continued development as a NASA approved sterilization technique for spacecraft subsystems and systems. The goal is to include this technique, with an appropriate specification, in NPR 8020.12C as a low temperature complementary technique to the dry heat sterilization process.To meet microbial reduction requirements for all Mars in-situ life detection and sample return missions, various planetary spacecraft subsystems will have to be exposed to a qualified sterilization process. This process could be the elevated temperature dry heat sterilization process (~115 C for 40 hours) which was used to sterilize the Viking lander spacecraft. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements.The VHP process is widely used by the medical industry to sterilize surgical instruments and biomedical devices, but high doses of VHP may degrade the performance of flight hardware, or compromise material properties. Our goal for this study was to determine the minimum VHP process conditions to achieve microbial reduction levels acceptable for planetary protection.

planetary protection↗

Solar Fridges and Personal Power Grids: How Berkeley Lab is Fighting Global Poverty (LBNL Science at the Theater)

At this November 26, 2012 Science at the Theater, scientists discussed the recently launched LBNL Institute for Globally Transformative Technologies (LIGTT) at Berkeley Lab. LIGTT is an ambitious mandate to discover and develop breakthrough technologies for combating global poverty. It was created with the belief that solutions will require more advanced R&D and a deep understanding of market needs in the developing world. Berkeley Lab's Ashok Gadgil, Shashi Buluswar and seven other LIGTT scientists discussed what it takes to develop technologies that will impact millions of people. These include: 1) Fuel efficient stoves for clean cooking: Our scientists are improving the Berkeley Darfur Stove, a high efficiency stove used by over 20,000 households in Darfur; 2) The ultra-low energy refrigerator: A lightweight, low-energy refrigerator that can be mounted on a bike so crops can survive the trip from the farm to the market; 3) The solar OB suitcase: A low-cost package of the five most critical biomedical devices for maternal and neonatal clinics; 4) UV Waterworks: A device for quickly, safely and inexpensively disinfecting water of harmful microorganisms.

CLIMATIC CHANGE↗

Integrating Symbolic and Statistical Methods for Testing Intelligent Systems Applications to Machine Learning and Computer Vision

Embedded intelligent systems ranging from tiny im- plantable biomedical devices to large swarms of autonomous un- manned aerial systems are becoming pervasive in our daily lives. While we depend on the flawless functioning of such intelligent systems, and often take their behavioral correctness and safety for granted, it is notoriously difficult to generate test cases that expose subtle errors in the implementations of machine learning algorithms. Hence, the validation of intelligent systems is usually achieved by studying their behavior on representative data sets, using methods such as cross-validation and bootstrapping.In this paper, we present a new testing methodology for studying the correctness of intelligent systems. Our approach uses symbolic decision procedures coupled with statistical hypothesis testing to. We also use our algorithm to analyze the robustness of a human detection algorithm built using the OpenCV open-source computer vision library. We show that the human detection implementation can fail to detect humans in perturbed video frames even when the perturbations are so small that the corresponding frames look identical to the naked eye.

Jha, Sumit Kumar↗

Wireless optofluidic systems for programmable in vivo pharmacology and optogenetics

Provided are implantable, injectable and/or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate, one or more microfluidic channels embedded in or supported by the substrate and a fluid actuator in operational communication with one or more reservoirs and responsive to a wireless control signal. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In some embodiments, the devices are self-powered and fully implantable. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

Rogers, John A.↗

Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

Willis, Peter↗

A facile route to synthesize CdZnSe core–shell-like alloyed quantum dots via cation exchange reaction in aqueous system

Highlights: • Water-soluble CdZnSe alloyed QDs synthesized by cation exchange reaction. • The as-prepared CdZnSe QDs have fairly good luminescence properties. • The surface defects of obtained QDs were removed due to the alloyed structure. - Abstract: Water-soluble CdZnSe alloyed nanocrystals have been successfully prepared via “green” cation exchange reaction in aqueous system. The X-ray diffraction (XRD) patterns indicate that the as-prepared nanocrystals had high crystallinity and small particle size of 4–5 nm. The absorption spectra of CdZnSe show red shift of 100 nm from 375 to 475 nm. Moreover, the band-gap photoluminescent (PL) emission has a red shift of 50 nm from 430 to 480 nm with the increase of the reaction time. On the basis of the PL properties and transmission electron microscopy (TEM) images, one kind of core–shell-like structure model was proposed, which resulted from the different cation exchange reaction rates. This structure could greatly improve the luminescence properties by the removal of surface defect of quantum dots. This work would support potential applications in optoelectronic devices, and biomedical tags fields.

36 MATERIALS SCIENCE↗

Unlocking the brain's mysteries: Meet the bioengineers behind next-generation neural devices

Bioengineers in the Neural Technologies Group at Lawrence Livermore are creating the next generation of clinical- and research-quality neural interfaces. The goal is to gain a fundamental understanding of neuroscience, treat a variety of debilitating neurological disorders (such as Parkinson's, depression, and epilepsy), and restore lost neural functions such as sight, hearing, and mobility.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoparticle Assembly at Liquid–Liquid Interfaces: From the Nanoscale to Mesoscale

Abstract In the past few decades, novel syntheses of a wide range of nanoparticles (NPs) with well‐defined chemical composition and structure have opened tremendous opportunities in areas ranging from optical and electronic devices to biomedical markers. Controlling the assembly of such well‐defined NPs is important to effectively harness their unique properties. The assembly of NPs at liquid–liquid interfaces is becoming a central topic both in surface and colloid science. Hierarchical structures, including 2D films, 3D capsules, and structured liquids, have been generating significant interest and are showing promise for physical, chemical, and biological applications. Here, a brief overview of the development of the self‐assembly of NPs at liquid–liquid interfaces is provided, from theory to experiment, from synthetic NPs to bio‐nanoparticles, from water–oil to water–water, and from “liquid‐like” to “solid‐like” assemblies.

Shi, Shaowei↗

Synthesis, Characterization and Comparative Luminescence Studies of Rare-Earth-Doped Gd{sub 2}O{sub 3} Nanoparticles

A facile direct precipitation method was used for the synthesis of luminescence nanomaterial. Gd{sub 2}O{sub 3} doped with rare earth element Eu{sup 3+} is synthesized by polyol route. The synthesized nanoparticles show their characteristic red emission. The nanoparticles are characterized by x-ray diffractometer (XRD), Fourier transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM) and photoluminescence (PL) study. The synthesized nanoparticles are spherical particles with ~ 30 nm size. The photoluminescence studies show the characteristic Eu{sup 3+} red emission. The PL study shows the intensity of the magnetic dipole transition ({sup 5}D{sub 0}→ {sup 7}F{sub 1}) at 592 nm compared to that of the electronic dipole transition ({sup 5}D{sub 0}→ {sup 7}F{sub 2}) at 615 nm. The nanomaterials can show significant application in various display devices and biomedical applications for tracking.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Porous Janus materials with unique asymmetries and functionality

Porous Janus materials have attracted widespread attention due to their asymmetry in wettability, charge, pore size or structure, thermal/electrical conductivity, and chemical activity, among other properties. Multifunction integration and unique directional manipulation of liquid, ions, or gas within porous Janus materials enable rapid progress in diverse applications such as water-oil separation, fog collection, personal moisture and healthcare management, energy conversion, desalination, sensor devices, and biomedical applications. Additionally, compared with conventional homogeneous materials, porous Janus materials not only showcase superior performance and energetic potential but also open up new applications by virtue of the synergistic or independent effects of asymmetry. This in-depth review systematically analyzes the research progress of porous Janus materials, highlighting fabrication strategies, synergistic/independent work mechanisms, and emerging advanced applications. Finally, ongoing challenges and outlook for the future research of porous Janus materials are presented.

36 MATERIALS SCIENCE↗

Perspectives on Machine Learning-assisted Plasma Medicine: Towards Automated Plasma Treatment

Cold atmospheric plasmas (CAPs) have shown great promise for medical applications through their synergistic chemical, electrical, and thermal effects, which can induce therapeutic outcomes. However, safe and reproducible plasma treatment of complex biological surfaces poses a major hurdle to the widespread adoption of CAPs for medical applications. Predictive modeling of the mutual interactions between the plasma and biological surfaces and, thus, systematic approaches to quantify and predict plasma treatment outcomes remain largely elusive due to the lack of mechanistic understanding of plasma-surface interactions that can span across vastly different length-and time-scales. In addition, real-time sensing capabilities in biomedical CAP devices are often limited, which can be detrimental to plasma treatment due to the intrinsic plasma and surface variability during the treatment, as well as sensitivity to external perturbations. All of these challenges can make reproducible and effective plasma treatment of biological surfaces difficult to realize, which is further compounded by errors due to human operation of hand-held CAP devices. Machine learning and data-driven approaches can be particularly useful in addressing these challenges in three major ways: (i) data-driven modeling of hard-to-model plasma-surface interactions and plasma treatment outcomes; (ii) learning data analytics for plasma and surface diagnostics in real-time; and (iii) developing predictive controllers that enable reliable and effective CAP treatments. Furthermore, this paper discusses the promise of machine learning to accelerate plasma medicine research in these areas, toward machine learning-assisted and automated CAP treatment of complex biological surfaces.

60 APPLIED LIFE SCIENCES↗

SU-E-T-434: Evaluation of the Machine Performance Check (MPC) Program for Truebeam 2.0

Purpose: Machine Performance Check (MPC) is a software application used to verify that the TrueBeam machine is operating within major specifications prior to treatment. Used in combination with a phantom named Isocal, it verifies beam output, beam uniformity, treatment isocenter size, coincidence of treatment and imaging isocenters, positioning accuracy of kV and MV imaging systems, accuracy of collimator and gantry rotation angle, positioning accuracy of jaws and MLC leafs, and couch positioning. The tests can be performed semi-automatically and requires approximately 10 minutes of machine time. It is the purpose of this study to report the performance of this program. Methods: A pre-release version of the MPC tool was installed on a Truebeam linac with 6D couch at our center. Baseline beam output measurements were taken for 5 photon beams (6–15 MV, 6 FFF, 10 FFF) and 5 electron beams (6–20 MeV). Deviations from the baseline output were subsequently recorded for several days and compared against independent measurements from a PTW farmer chamber and our daily QA device (Fluke Biomedical Tracker) as part of an ongoing evaluation. Results: The beam output deviations between the MPC and the PTW chamber measurements were within ±0.7% for photons beams and ±1.0% for electrons beams. This was similar to the tracker performance. There were some isolated incidents where the MPC measurements had unexplained spikes (>3%) that disappeared on a repeat measurement. MPC was also able to detect maximum positioning errors in the jaws (1.12 mm), MLCs (1.14 mm), and couch roll (0.11°). Conclusion: Overall, the ability of the MPC to monitor linac output stability was comparable to that of ionization chamber-based measurements. MPC also provided fast daily mechanical tests not currently available in the clinic. How best to utilize this previously unavailable data is still under investigation.

07 ISOTOPE AND RADIATION SOURCES↗

Perovskite nanowire–block copolymer composites with digitally programmable polarization anisotropy

One-dimensional (1D) nanomaterials with highly anisotropic optoelectronic properties are key components in energy harvesting, flexible electronics, and biomedical imaging devices. 3D patterning methods that precisely assemble nanowires with locally controlled composition and orientation would enable new optoelectronic device designs. As an exemplar, we have created and 3D-printed nanocomposite inks composed of brightly emitting colloidal cesium lead halide perovskite (CsPbX 3 , X = Cl, Br, and I) nanowires suspended in a polystyrene-polyisoprene-polystyrene block copolymer matrix. The nanowire alignment is defined by the programmed print path, resulting in optical nanocomposites that exhibit highly polarized absorption and emission properties. Several devices have been produced to highlight the versatility of this method, including optical storage, encryption, sensing, and full-color displays.

36 MATERIALS SCIENCE↗

Neutron Scattering Investigation of the Relationship between Molecular Structure, Morphology and Dynamics in Conjugated Polymers

Conjugated polymers (CP) have enabled significant technological advances such as inexpensive organic solar cells (OPVs), biomedical sensor devices and flexible displays incorporating organic light emitting diodes (OLEDs) among others. Some of the distinguishing properties of CPs include simple processing from solutions, synthesis from abundant raw materials (C, H, S, N), flexible device form-factors and a capacity to fine-tune optical and electronic properties. Moreover, conductive polymers can assemble into large organized structures, such as nanowires and networks, that can significantly boost their performance. However, it is observed that small changes in the structure of the molecules (e.g. addition of alkyl groups) results in drastic and unpredictable changes in organized structures and electronic properties. This project utilized a comprehensive suite of elastic (SANS and USANS) and quasi-elastic (NSE and backscattering spectroscopy) neutron scattering techniques along with simultaneous property evaluation to unravel the relationships between molecular structure, self-assembly, directed-assembly and the resulting properties. Completed project objectives were: 1) to evaluate the influence of chain architecture on solution conformation, 2) to determine of the influence of molecular structure on CP self and directed assembly and 3) to study the correlation between dynamic molecular relaxations and macroscopic properties of CPs in the solid state. The experimental components of the project were further complemented by advanced molecular simulation strategies (e.g. atomistic MD and DFT) to fully understand the relationship between chain structure, mesoscale morphology, dynamic relaxation processes and the macroscopic properties.

36 MATERIALS SCIENCE↗

Portable mass spectrometer

Eighteen-pound unit gives real-time onsite sample analysis. Mass range is twelve to two hundred atomic mass units with resolution of two hundred. Device has biomedical application possibilities, such as determination of alcohol and gas content of blood and breath.

Giffin, C. E.↗