Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bifacial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Understanding and Advancing Bifacial Thin Film Solar Cells

Because bifacial solar cells increase the power generated per area, their market share is projected to increase over the next decade. While silicon technologies have implemented bifacial technology, little progress has occurred in bifacial thin film (BTF) solar cells. Understanding the factors that limit performance is critical to advancing BTF cells. We show that recombination at the back interface has limited device performance of fabricated BTF devices. Improved BTF performance will require decreasing recombination at the back interface, through passivation or by reducing downward band-bending at this interface. Increasing carrier lifetimes improves performance, but increasing hole density has little effect.

14 SOLAR ENERGY↗

Light Management in Bifacial Photovoltaics with Spectrally Selective Mirrors

Spectrally-selective mirrors that simultaneously provide above-bandgap anti-reflection and sub-bandgap light rejection are tested for their ability to provide passive cooling to partially sub-bandgap transparent bifacial photovoltaics. The optical and thermal benefits of both idealized and real, low-complexity spectrally-selective mirrors on single-axis tracking, bifacial PERC arrays under realistic conditions are tested via rigorous finite element simulations. Four- and six-layer mirror designs increased carrier generation beyond what traditional antireflection coatings can provide without the associated cell heating. Here, idealized mirrors were found to provide up to 2.4 °C of cooling when included on both air/glass interfaces of the bifacial module.

14 SOLAR ENERGY↗

Comparison of Bifacial Solar Irradiance Model Predictions With Field Validation

Models predicting rear irradiance for bifacial systems are critical to establish accurate estimates of energy yield. In this paper, we compare five published bifacial irradiance models, varying clearance, row spacing, tilt, and albedo to measure the sensitivity to these parameters. Bifacial energy gains (BG E ) as high as 20% are predicted for some configurations. Model agreement is generally good for low ground clearance (clearance heights lower than 0.75 times the collector width), but at higher clearances, finite system size and edge effects become a significant factor in simulations, stretching assumptions of infinite system extent made in some models. In addition, rear irradiance uniformity is improved at high ground clearance, as expected. A test-bed construction and results are described for comparison between modeled and measured data in Golden, CO, USA. Finally, the investigations indicate that model agreement for BG E calculation is better than 2% (absolute) when compared with measured results, depending on the system configuration.

14 SOLAR ENERGY↗

Model and Validation of Single-Axis Tracking with Bifacial PV

Single-axis tracking is a cost-effective deployment strategy for large-scale ground-mount photovoltaic systems in regions with high direct-normal irradiance. Bifacial modules in 1-axis-tracking systems boost energy yield by 4%-15% depending on module type and ground albedo, with a global average of 9%. This benefit is in addition to the 15%-25% energy gain already afforded by single-axis tracking relative to fixed-tilt deployments. Here, we compare model results against field performance data for two side-by-side bifacial/monofacial tracked systems - one in Albuquerque, NM, USA, and one in eastern Oregon. The Albuquerque system shows monthly rear irradiance gain of 10%-14.9%, and the Oregon bifacial system has an average performance ratio 9.4% higher than the monofacial system. Both results match bifacial irradiance model results within uncertainty. Simulations show that smart tracking algorithms can offer more than 1% improvement on annual energy yield by adjusting tilt angle under cloudy conditions. Finally, ray-tracing simulations investigated edge brightening, suggesting a 15%-25% increase in rear irradiance at the ends of tracker rows, but up to 20% loss from center-mounted torque tubes, creating multiple shadows.

14 SOLAR ENERGY↗

Suggested Modifications for Bifacial Capacity Testing

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of photovoltaic systems. With the increasing deployment of bifacial photovoltaic modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error were inherently higher for the measured capacity of bifacial systems, they could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance—either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2–10-month observation period. Capacity test accuracy could be improved further by using the measured back-of-module temperature and the IEC 61724-2 test method for well curated systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

Bifacial Simulation in SAM

A bifacial irradiance model is introduced within the System Advisor Model (SAM). The modeling steps and implementation in SAM are presented. The results of a bifacial simulation are compared against several other modeling programs and shown to match within 1 - 2 percent for fixed-axis and horizontal single axis tracked systems. An example case study is presented to demonstrate how the model can be used to evaluate bifacial systems, with a variety of results presented to illustrate different sensitivities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Albedo Data to Facilitate Bifacial PV System Planning

For mono-facial photovoltaic (PV) systems, the ground-reflected radiation typically comprises only 1% to 2% of the total radiation received by the PV module. Consequently, a rudimentary understanding of the ground albedo is adequate for predicting their performance. However, for bifacial PV modules where their benefit is determined by the additional radiation reflected by the ground to their backside, a better understanding of albedo values and characteristics is needed by both the PV and financial communities to better estimate performance and to reduce risk. This was identified as a key need at the 2018 Bifacial PV Workshop. Subsequently, the Department of Energy (DOE) has initiated work with the National Renewable Energy Laboratory (NREL) to provide albedo data for different locations and ground surfaces for both the simulation of bifacial PV systems and for summary information, including variations in albedo with respect to time of day, season, and year. This albedo data base will include data from measurement networks (SURFRAD and Ameriflux), and the PV industry is also asked to provide their albedo measurements and take part in a cooperative effort to provide an expansive and accurate data base of albedo values.

14 SOLAR ENERGY↗

The Subtle Art of Bifacial Performance Modeling

The PV industry is set for rapid uptake of bifacial PV if key barriers are eliminated, such as accurate performance models, standards around the rating of bifacial modules, and accurate assessment of site albedo. In this presentation we will talk about the changes to the ray-trace program bifacial_radiance, it's new capabilities that allow it to model the performance for any module at any size array. A new graphical user interface has been released on time for this conference. Preliminary results for torque-tube shading are also presented.

14 SOLAR ENERGY↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Spectral Effects in Albedo and Rearside Irradiance Measurment for Bifacial Performance Estimation: Preprint

Albedo data are essential for accurate prediction of bifacial PV module performance. However, spectral response mismatch between PV modules and irradiance sensors used in albedometers can limit the accuracy of performance predictions. In order to provide quantitative assessment of this effect, we investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystallinesilicon PV reference cells in comparison to a representative crystalline-silicon bifacial PV module for nine different representative ground surface materials. Calculations are performed using simulated solar spectra together with catalogued spectral reflectivity data distributed with the SMARTS simulation software. For the specific materials considered, the results show that albedo measurement using thermopile pyranometers could over or under-estimate the ground-reflected radiation usable by a bifacial PV module by up to 10%, versus only approximately 4% total range of variation for a PV reference cell.

Albedo↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.

bifacial modules↗

IEA PVPS Task 13 Techno-Economic Study of Bifacial Photovoltaic Systems on Single Axis Trackers

The International Energy Agency PVPS Task 13 has assembled an international team of photovoltaic (PV) researchers from government labs, academia, and industry to study the specific application of bifacial PV modules deployed on tracking systems. This configuration is of particular interest as it has been identified as the PV system design with the lowest Levelized Cost of Electricity (LCOE) for over 90% of the world [1]. As such, much research, development, and commercial activity are focused on further optimizing this system design for different regions and markets, including field deployment and advanced modeling activities. Despite these efforts, many challenges remain to overcome with this system design. This conference paper will report on several areas the team is working on as part of this project. The first part of this study focuses on extensive interviews with PV tracker companies (we have identified 35) and customers worldwide to identify emerging technology trends, design diversity, market environments, and the reliability and performance of these systems. We will provide a market summary of technologies such as advanced tracking algorithms, methods for dealing with topography within the PV plant, different system configurations and layouts, backside irradiance optimization from albedo enhancement, and ground sculpting. We will also review dual-use applications of tracked bifacial systems, such as Agrivoltaics and Building-Integrated PV. These interviews are underway now, and we will be able to report our initial findings at the conference. The second part of the study focuses on summarizing performance monitoring and evaluation methods, with particular attention to capacity and acceptance testing for such systems. The third part of the study reviews performance modeling and yield assessment methods for these tracked bifacial PV systems. The final part of the study covers reliability and operations, and maintenance data from these systems.

albedo↗

Validating Irradiance Models for High-Latitude Vertical Bifacial Photovoltaic Systems

Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.

bifacial↗

Thermodynamic efficiency limits of classical and bifacial multi-junction tandem solar cells: An analytical approach

Bifacial tandem cells promise to reduce three fundamental losses (i.e., above-bandgap, below bandgap, and the uncollected light between panels) inherent in classical single junction photovoltaic (PV) systems. The successive filtering of light through the bandgap cascade and the requirement of current continuity make optimization of tandem cells difficult and accessible only to numerical solution through computer modeling. The challenge is even more complicated for bifacial design. In this paper, we use an elegantly simple analytical approach to show that the essential physics of optimization is intuitively obvious, and deeply insightful results can be obtained with a few lines of algebra. This powerful approach reproduces, as special cases, all of the known results of conventional and bifacial tandem cells and highlights the asymptotic efficiency gain of these technologies.

Alam, Muhammad Ashraful (ORCID:0000000187756043)↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗