Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam position monitors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

The design, construction, and commissioning of the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90%C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times,and present details on their respective commissioning campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Embedded EPICS server for PowerPMAC motion controllers

An embedded server layer of Experimental Physics and Industrial Control System (EPICS) for PowerPMAC motion controllers has been developed and deployed at two undulator beamlines of the National Institute of General Medical Sciences and the National Cancer Institute (GM/CA) Structural Biology Facility at the Advanced Photon Source (APS). This compact, open source solution makes the power and versatility of PowerPMAC motion controls directly accessible to distributed EPICS clients. At GM/CA the system controls about 200 servo and stepper motors — both encoded and unencoded — and multiple digital and analog I/O accessories. The server stack comprises two sublayers: a lower-level driver and database that communicates directly with PowerPMAC, and a facility-specific soft sublayer built on top. The paper describes installing EPICS on PowerPMAC, the implementation of both layers and client examples, including on-the-fly scanning.

EPICS↗

Sidelooking laser altimeter for a flight simulator

An improved laser altimeter for a flight simulator which allows measurement of the height of the simulator probe above the terrain directly below the probe tip is described. A laser beam is directed from the probe at an angle theta to the horizontal to produce a beam spot on the terrain. The angle theta that the laser beam makes with the horizontal is varied so as to bring the beam spot into coincidence with a plumb line coaxial with the longitudinal axis of the probe. A television altimeter camera observes the beam spot and has a raster line aligned with the plumb line. Spot detector circuit coupled to the output of the TV camera monitors the position of the beam spot relative to the plumb line.

Webster, L. D.↗

Measurement of Beam Energy in the Fermilab's Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portable Electron-Beam Free-Form Fabrication System

A portable electron-beam free-form fabrication (EB F3) system, now undergoing development, is intended to afford a capability for manufacturing metal parts in nearly net sizes and shapes. Although the development effort is oriented toward the eventual use of systems like this one to supply spare metal parts aboard spacecraft in flight, the basic system design could also be adapted to terrestrial applications in which there are requirements to supply spare parts on demand at locations remote from warehouses and conventional manufacturing facilities. Prior systems that have been considered for satisfying the same requirements (including prior free-form fabrication systems) are not easily portable because of their bulk and massive size. The mechanical properties of the components that such systems produce are often inferior to the mechanical properties of the corresponding original, conventionally fabricated components. In addition, the prior systems are not efficient in the utilization of energy and of feedstock. In contrast, the present developmental system is designed to be sufficiently compact and lightweight to be easily portable, to utilize both energy and material more efficiently, and to produce components that have mechanical properties approximating those of the corresponding original components. The developmental EB F3 system will include a vacuum chamber and associated vacuum pumps, an electron-beam gun and an associated power supply, a multiaxis positioning subsystem, a precise wire feeder, and an instrumentation system for monitoring and control. The electron-beam gun, positioning subsystem, and wire feeder will be located inside the vacuum chamber (see figure). The electron beam gun and the wire feeder will be mounted in fixed positions inside the domed upper portion of the vacuum chamber. The positioning subsystem and ports for the vacuum pumps will be located on a base that could be dropped down to provide full access to the interior of the chamber when not under vacuum. During operation, wire will be fed to a fixed location, entering the melted pool created by the electron beam. Heated by the electron beam, the wire will melt and fuse to either the substrate or with the previously deposited metal wire fused on top of the positioning table. Based on a computer aided design (CAD) model and controlled by a computer, the positioning subsystem

Watson, J. Kevin↗

Metrology system for the Terrestrial Planet Finder Coronagraph

The Terrestrial Planet Finder (TPF) employs an aggressive coronagraph designed to obtain better than 1e-10 contrast inside the third Airy ring. Minute changes in low-order aberration content scatter significant light at this position. One implication is the requirement to control low-order aberrations induced by motion of the secondary mirror relative to the primary mirror; sub-nanometer relative positional stability is required. We propose a 6-beam laser truss to monitor the relative positions of the two mirrors. The truss is based on laser metrology developed for the Space Interferometry Mission.

Terrestrial Planet Finder (TPF)↗

Machine Learning for LBNF Beam Diagnostics

This paper focuses on developing a machine learning model for predicting initial beam parameters for the Long Baseline Neutrino Facility (LBNF) beamline using downstream muon monitor data. Parameters such as proton beam position on target, sigma on target, focusing horn current, and focusing horn tilt are parameters we anticipate to be predictable based on the muon monitors. Uncertainty in initial beam condition measurements are a major contributor to uncertainty in downstream flux, and over operation time beam misalignment can occur [1]. A machine learning model has promise to detect anomalies along the beamline based on discrepancies between predicted configurations and measured configurations, and thus can expedite error detection and handling. A PyTorch neural network is defined, trained, and tested. The developed model currently does not provide reliable predictions, with the lowest loss being 0.09.. Further steps to improve the model’s accuracy are discussed, as well as future plans to detect anomalous beam conditions using a digital twin.

O'Brien, Bridget [Fermilab]↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

Position-And-Direction Sensor For Light Beams

Optoelectronic sensor measures both position and direction of incidence of laser beam or other narrow beam of light. New sensor part of robotic welding system in which laser beam reflected from pool of molten metal and monitored by lateral-position sensor. To provide unambiguous measurement of both lateral position and direction of incident beam, sensor includes two position-sensitive photodetectors or linear arrays of photodetectors.

Smith, Matthew A.↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Capability Improvements at Marshall Space Flight Center's X-Ray and Cryogenic Facility

The X-Ray & Cryogenic Facility (XRCF) at Marshall Space Flight Center is the world’s largest x-ray optic calibration facility and NASA’s premier cryogenic optical test facility. Built specifically to calibrate the Chandra telescope, the facility contributed to several other x-ray missions until 2005 when it became dedicated to normal incidence optical testing at cryogenic temperatures. Recently the facility’s x-ray test capability has been returned to service and updated. New beam monitors, focal plane detectors, and test article and instrument positioning systems have been added. The x-ray data acquisition system has been updated. A real-time position monitoring metrology system is being developed that will enable calibration of large diameter optics via partial illumination in a diverging beam. The newly expanded x-ray test capabilities of the facility will be discussed.

XRCF↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

AI-driven Neutrino Beam Diagnostics for Next-Generation Neutrino Experiments

The accelerator-driven beam uncertainty limits oscillation measurements in long-baseline neutrino experiments. Spill-resolved beam diagnostics and real-time inference are necessary to address these neutrino flux systematics. As such, we present a machine-learning-based beam monitoring framework developed and validated using data from the T2K experiment. Our approach uses downstream, spill-by-spill muon monitor observables to predict upstream parameters such as proton beam position and width. We achieve high predictive accuracy on nominal runs, demonstrating robust baseline performance whether the model is trained on stable runs or systematically varied conditions. The framework is designed to be robust against domain shifts, allowing the neural network architectures and inference strategies developed with T2K data to be retrained and validated using LBNF simulations, with the goal of eventual deployment under real LBNF/DUNE operating conditions. This scalable approach to real-time beam inference offers a pathway toward reducing flux systematics for next-generation neutrino experiments such as DUNE.

Aney, Noah [Fermilab; U. Chicago (main)]↗

Metrology Arrangement for Measuring the Positions of Mirrors of a Submillimeter Telescope

The position of the secondary mirror of a submillimeter telescope with respect to the primary mirror needs to be known .0.03 mm in three dimensions. At the time of this reporting, no convenient, reasonably priced arrangement that offers this capability exists. The solution proposed here relies on measurement devices developed and deployed for the GeoSAR mission, and later adapted for the ISAT (Innovative Space Based Radar Antenna Technology) demonstration. The measurement arrangement consists of four metrology heads, located on an optical bench, attached to the secondary mirror. Each metrology head has a dedicated target located at the edge of the primary mirror. One laser beam, launched from the head and returned by the target, is used to measure distance. Another beam, launched from a beacon on the target, is monitored by the metrology head and generates a measurement of the target position in the plane perpendicular to the laser beam. A 100-MHz modulation is carried by a collimated laser beam. The relevant wavelength is the RF one, 3 m, divided by two, because the light carries it to the target and back. The phase change due to travel to the target and back is measured by timing the zero-crossing of the RF modulation, using a 100-MHz clock. In order to obtain good resolution, the 100-MHz modulation signal is down-converted to 1 kHz. Then, the phase change corresponding to the round-trip to the target is carried by a 1-kHz signal. Since the 100-MHz clock beats 100,000 times during one period of the 1-kHz signal, the least-significant-bit (LSB) resolution is LSB = 0.015 mm.

Abramovici, Alex↗