Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electron beam diagnostics for a superconducting radio frequency photoelectron injector

A superconducting radio frequency (SRF) photoelectron injector is currently under construction by a collaboration of BESSY, DESY, FZD, and MBI. The project aims at the design and setup of a continuous-wave SRF injector including a diagnostics beamline for the ELBE free electron laser (FEL) and to address R and D issues on low emittance injectors for future light sources such as the BESSY FEL. Of critical importance for the injector performance is the control of the electron beam parameters. For this reason a compact diagnostics beamline is under development, serving a multitude of operation settings. In this paper the layout and the rationale of the diagnostics beamline are described. Furthermore detailed information on specific components is given, together with results from laboratory tests and data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development Of Non-Invasive Beam Diagnostics By Quantum Optics-Based Detection

We report our effort and latest progress developing diagnostics using quantum optics-based detection method for determining the spatial properties and current of electron beams. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin’s quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size and total current. We tested this method for an e-beam with currents ranging from 30 to 110 µA. Our study shows this approach is insensitive to electron kinetic energy, and is initially verified experimentally between 10 to 20 keV. A different approach was also performed with highly excited rubidium atoms in Rydberg states through a coherent two photon process. We use this detection scheme to measure the electric field generated by a

Zhang, S. [Thomas Jefferson National Accelerator F↗

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

43 PARTICLE ACCELERATORS↗

Measurements of the Propagation of EM Waves through the Vacuum Chamber of the PEP-II Low Energy Ring for Beam Diagnostics

We present the results of our measurements of the electron cloud density in the PEP-II low energy ring (LER) by propagating a TE wave into the beam pipe. By connecting a signal generator to a beam position monitor button we can excite a signal above the vacuum chamber cut-off frequency and measure its propagation through the beam pipe with a spectrum analyzer connected to another button about 50 meters away. The measurement can be performed with different beam conditions and also at different settings of the solenoids used to reduce the build up of electrons. The presence of a modulation in the TE wave transmission, synchronous with the beam revolution frequency, which appear to increase in depth when the solenoids are switched off, seem to be directly correlated to the electron cloud density in the region between the two BPM's. In this paper we present and discuss the measurements taken in the Interaction Region 12 straight of the LER during 2006 and the first part of 2007.

43 PARTICLE ACCELERATORS↗

Optical Sideband Generation: a Longitudinal Electron Beam Diagnostic Beyond the Laser Bandwidth Resolution Limit

Electro-optic sampling (EOS) is widely used as a technique to measure THz-domain electric field pulses such as the self-fields of femtosecond electron beams. We present an EOS-based approach for single-shot spectral measurement that excels in simplicity (compatible with fiber integration) and bandwidth coverage (overcomes the laser bandwidth limitation), allowing few-fs electron beams or single-cycle THz pulses to be characterized with conventional picosecond probes. It is shown that the EOS-induced optical sidebands on the narrow-bandwidth optical probe are spectrally-shifted replicas of the THz pulse. An experimental demonstration on a 0-3 THz source is presented.

43 PARTICLE ACCELERATORS↗

Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

Source record↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗

The He/Ne beam diagnostic for line-ratio spectroscopy in the island divertor of Wendelstein 7-X

a versatile gas injection system and an absolute calibrated spectroscopic observation system with more than 200 lines-of-sight have been installed in two divertor locations in the Wendelstein 7-X stellarator. This powerful setup enables among other measurements to infer T e and n e in the divertor region by means of line-ratio spectroscopy on thermal helium. This is a robust and routinely used diagnostic at W7-X and this work describes its main characteristics and shows some examples of T e and n e profiles. In particular it is shown that the inclusion of high Rydberg states in the helium collisional-radiative model is necessary to obtain a realistic estimate of T e . The applicability of the diagnostic is currently being extended towards the low T e and high n e conditions occurring during detachment by means of line-ratio spectroscopy on neon. Initial T e , n e profiles obtained with a neon-beam are here presented.

47 OTHER INSTRUMENTATION↗

Modeling of Diamond Based Devices for Beam Diagnostics

Beamlines at new light sources, such as the National Synchrotron Light Source II will operate at flux levels beyond the saturation level of existing diagnostics, necessitating the development of new devices. Currently, there is no detector which can span the entire flux range that is possible even in a second generation light source and will become crucial for next generation light sources. One new approach is a diamond-based detector that will be able to monitor beam position, flux and timing to much better resolution. Furthermore, this detector also has linear response to flux over 11 orders of magnitude. However, the successful development of the detector requires thorough understanding and optimization of the physical processes involved. We will discuss the new modeling capabilities we have been implementing in the VORPAL 3D code to investigate the effects of charge generation due to absorption of x-ray photons, transport, and charge trapping. We will report results from VORPAL simulations on charge collection and how it depends on applied field, charge trapping, and the energy of absorbed photons.

43 PARTICLE ACCELERATORS↗

Beamline Design and Beam Diagnostic for Mo-99 Production Facility Utilizing High Power Electron Accelerators

NorthStar Medical Isotope, LLC, is planning to produce 99 Mo through a γ,n reaction on 100 Mo. This pathway for 99 Mo production relies on the use of high-power electron accelerators, which are not currently commercially available. IBA Industrial announced in its Summer 2017 newsletter (http://iba-industrial.com/emailing/2017-beamline/index.html) that they have begun working on pulsed Rhodotron features (New Horizon project). This accelerator is capable of producing a high power and high energy electron beam suitable for production via a photonuclear route. Argonne National Laboratory (Argonne), in collaboration with Los Alamos National Laboratory (LANL), provided assistance to NorthStar in technology development. Over the course of several years, we have conducted several demonstrations of the technology that proved the feasibility of photo-nuclear approach. The target, designed by LANL, is composed of a series of 99 Mo disks held in a target holder with cooling gaps between the thin disks. Cooling of the target is provided by flowing helium gas under high pressure through the target holderHandling the high-power beam requires a carefully designed beam transport system because of likely vacuum failure if the beam strikes an uncooled part of the system. This publication summarizes recommendations on the beam transport line equipment, costs, and on the optional components.

43 PARTICLE ACCELERATORS↗

Electro-optic techniques in electron beam diagnostics

Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

43 PARTICLE ACCELERATORS↗

SU-F-I-73: Surface Dose from KV Diagnostic Beams From An On-Board Imager On a Linac Machine Using Different Imaging Techniques and Filters

Purpose: To quantitatively investigate the surface dose deposited in patients imaged with a kV on-board-imager mounted on a radiotherapy machine using different clinical imaging techniques and filters. Methods: A high sensitivity photon diode is used to measure the surface dose on central-axis and at an off-axis-point which is mounted on the top of a phantom setup. The dose is measured for different imaging techniques that include: AP-Pelvis, AP-Head, AP-Abdomen, AP-Thorax, and Extremity. The dose measurements from these imaging techniques are combined with various filtering techniques that include: no-filter (open-field), half-fan bowtie (HF), full-fan bowtie (FF) and Cu-plate filters. The relative surface dose for different imaging and filtering techniques is evaluated quantiatively by the ratio of the dose relative to the Cu-plate filter. Results: The lowest surface dose is deposited with the Cu-plate filter. The highest surface dose deposited results from open fields without filter and it is nearly a factor of 8–30 larger than the corresponding imaging technique with the Cu-plate filter. The AP-Abdomen technique delivers the largest surface dose that is nearly 2.7 times larger than the AP-Head technique. The smallest surface dose is obtained from the Extremity imaging technique. Imaging with bowtie filters decreases the surface dose by nearly 33% in comparison with the open field. The surface doses deposited with the HF or FF-bowtie filters are within few percentages. Image-quality of the radiographic images obtained from the different filtering techniques is similar because the Cu-plate eliminates low-energy photons. The HF- and FF-bowtie filters generate intensity-gradients in the radiographs which affects image-quality in the different imaging technique. Conclusion: Surface dose from kV-imaging decreases significantly with the Cu-plate and bowtie-filters compared to imaging without filters using open-field beams. The use of Cu-plate filter does not affect image-quality and may be used as the default in the different imaging techniques.

60 APPLIED LIFE SCIENCES↗