Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-P-39: Characterization of Dose Impact On Different Beam Fields Size Attenuation for Elekta IGRT Couch

Purpose: Quantification of the dosimetric impact of the Elekta IGRT treatment couch in different beam field sizes. Established the relationship of relative dose versus beam angle at different beam field sizes. Methods: Measurements of couch attenuation were performed at gantry angles from 180° to 120°, using a 0.125cc semiflex ionization chamber, isocentrically placed in the center of a homogeneous cylindric sliced RW3 phantom for 6 photon beams. Measurements were performed at six different field sizes (3×3, 5×5, 7×7,10×10, 12×12 and 15×15 cm2). The phantom were positioned at the center of the couche,100 MU were delivered at every gantry angle. The dose difference to the ion chamber was determined. Results: For oblique fields with 6 MV photons at the same gantry angle the attenuation coefficient value from the lagest to the smallest the order is field size 7 cm2,5 cm2,10 cm2,12 cm2,15 cm2 and 3 cm2. The biggest couch attenuation by up to 4.15% at the gantry angle of 140°for the field size of 7 cm2, while for the field size of 3 cm2 the couch attenuated value only 3.5%. The other field size couch attenuation values are between the couch attenuated value of field size of 7 cm2 and 3 cm2 Conclusion: The recommended treatment couch attenuation measured beam field size is 10×10 or 12×12 cm2. When measured using the beam field size 3×3 cm2 the tested value will be lower, while measuerd using the beam field size 7×7 cm2 the tested value will be higer than the recommended beam field size. This should be noted when modeling the treatment couch in the treatment planning system.

60 APPLIED LIFE SCIENCES↗

Radiative transfer model of dust attenuation curves in clumpy, galactic environments

The attenuation of starlight by dust in galactic environments is investigated through models of radiative transfer in a spherical, clumpy interstellar medium (ISM). We show that the attenuation curves are primarily determined by the wavelength dependence of absorption rather than by the underlying extinction (absorption+scattering) curve; the observationally derived attenuation curves cannot constrain a unique extinction curve unless the absorption or scattering efficiency is specified. Attenuation curves consistent with the “Calzetti curve” are found by assuming the silicate-carbonaceous dust model for the Milky Way (MW), but with the 2175 Å bump suppressed or absent. The discrepancy between our results and previous work that claimed the Small Magellanic Cloud dust to be the origin of the Calzetti curve is ascribed to the difference in adopted albedos; we use the theoretically calculated albedos, whereas the previous works adopted albedos derived empirically from observations of reflection nebulae. It is found that the attenuation curves calculated with the MW dust model are well represented by a modified Calzetti curve with a varying slope and UV bump strength. The strong correlation between the slope and UV bump strength, as found in star-forming galaxies at 0.5<z<2.0, is well reproduced when the abundance of the UV bump carriers is assumed to be 30%–40% of that of the MW dust; radiative transfer effects lead to shallower attenuation curves with weaker UV bumps as the ISM is more clumpy and dustier. We also argue that some local starburst galaxies have a UV bump in their attenuation curves, albeit very weak.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a low cost humate solution as an in situ amendment to enhance attenuation of uranium in an acidic plume - 15445

A single well injection test was conducted in the acidic portion of a groundwater contamination plume beneath the F-Area Seepage Basins on the U.S. Department of Energy's Savannah River Site to evaluate humate as a viable amendment to enhance attenuation of uranium and other radionuclides. Humate is typically used as an inexpensive organic fertilizer. A solution of humate was injected into a monitoring well in the heart of the F-Area Seepage Basins plume. The geochemical conceptual model suggests humate adsorbs to mineral surfaces creating a subsurface treatment zone in which uranium adsorption is enhanced. Following humate injection, groundwater was sampled from the injection well at regular intervals to determine the composition of groundwater and to evaluate the sorption of contaminants within the treatment zone. Attenuation of uranium, radioiodine and Strontium-90 was determined by comparing concentrations to analytes unaffected by the humate, specifically tritium, nitrate, and specific conductance. The post-injection monitoring data showed enhanced uranium attenuation in the treatment zone as uranium concentrations rebounded to only 68% of the pre-test concentrations. Radioiodine attenuation was complicated by changing speciation during the test. When pH was elevated by the humate injection, iodate dominated and enhanced attenuation was observed. As pH decreased, iodide dominated and enhanced attenuation decreased. Humate did not significantly attenuate Strontium-90. Results of the humate injection test demonstrate that humate strongly adsorbs to the aquifer sediments at acidic pH. Humate desorption curves suggest that a substantial fraction of humate will remain adsorbed to the sediments for long-periods of time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Broadband Lg Attenuation Modeling in the Middle East

We present a broadband tomographic model of Lg attenuation in the Middle East derived from source- and site-corrected amplitudes. Absolute amplitude measurements are made on hand-selected and carefully windowed seismograms for tens of stations and thousands of crustal earthquakes resulting in excellent coverage of the region. A conjugate gradient method is used to tomographically invert the amplitude dataset of over 8000 paths over a 45{sup o} x 40{sup o} region of the Middle East. We solve for Q variation, as well as site and source terms, for a wide range of frequencies ranging from 0.5-10 Hz. We have modified the standard attenuation tomography technique to more explicitly define the earthquake source expression in terms of the seismic moment. This facilitates the use of the model to predict the expected amplitudes of new events, an important consideration for earthquake hazard or explosion monitoring applications. The attenuation results have a strong correlation to tectonics. Shields have low attenuation, while tectonic regions have high attenuation, with the highest attenuation at 1 Hz is found in eastern Turkey. The results also compare favorably to other studies in the region made using Lg propagation efficiency, Lg/Pg amplitude ratios and two-station methods. We tomographically invert the amplitude measurements for each frequency independently. In doing so, it appears the frequency-dependence of attenuation is not compatible with the power law representation of Q(f), an assumption that is often made.

58 GEOSCIENCES↗

DUST ATTENUATION IN DISK-DOMINATED GALAXIES: EVIDENCE FOR THE 2175 A DUST FEATURE

The attenuation of starlight by interstellar dust is investigated in a sample of low-redshift, disk-dominated star-forming galaxies using photometry from GALEX and SDSS. By considering broadband colors as a function of galaxy inclination, we are able to confidently separate trends arising from increasing dust opacity from possible differences in stellar populations, since stellar populations do not correlate with inclination. We are thus able to make firm statements regarding the wavelength-dependent attenuation of starlight for disk-dominated galaxies as a function of gas-phase metallicity and stellar mass. All commonly employed dust attenuation curves (such as the Calzetti curve for starbursts, or a power-law curve) provide poor fits to the ultraviolet colors for moderately and highly inclined galaxies. This conclusion rests on the fact that the average FUV-NUV color varies little from face-on to edge-on galaxies, while other colors such as NUV-u and u - r vary strongly with inclination. After considering a number of model variations, we are led to speculate that the presence of the strong dust extinction feature at 2175 A seen in the Milky Way extinction curve is responsible for the observed trends. If the 2175 A feature is responsible, these results would constitute the first detection of the feature in the attenuation curves of galaxies at low redshift. Independent of our interpretation, these results imply that the modeling of dust attenuation in the ultraviolet is significantly more complicated than traditionally assumed. These results also imply a very weak dependence of the FUV-NUV color on total FUV attenuation, and we conclude from this that it is extremely difficult to use only the observed UV spectral slope to infer the total UV dust attenuation, as is commonly done. We propose several simple tests that might finally identify the grain population responsible for the 2175 A feature.

79 ASTRONOMY AND ASTROPHYSICS↗

Attenuator design for organs at risk in total body irradiation using a translation technique

Total body irradiation (TBI) is an efficient part of the treatment for malignant hematological diseases. Dynamic TBI techniques provide great advantages (e.g., dose homogeneity, patient comfort) while overcoming treatment room space restrictions. However, with dynamic techniques come additional organs at risk (OAR) protection challenges. In most dynamic TBI techniques, lead attenuators are used to diminish the dose received by the OARs. The purpose of this study was to characterize the dose deposition under various shapes of attenuators in static and dynamic treatments. This characterization allows for the development of a correction method to improve attenuator design in dynamic treatments. The dose deposition under attenuators at different depths in dynamic treatment was compared with the static situation based on two definitions: the coverage areas and the penumbra regions. The coverage area decreases with depth in dynamic treatment while it is stable for the static situation. The penumbra increases with depth in both treatment modes, but the increasing rate is higher in the dynamic situation. Since the attenuator coverage is deficient in the dynamic treatment mode, a correction method was developed to modify the attenuator design in order to improve the OAR protection. The correction method is divided in two steps. The first step is based on the use of elongation charts, which provide appropriate attenuator coverage and acceptable penumbra for a specific depth. The second point is a correction method for the thoracic inclination, which can introduce an orientation problem in both static and dynamic treatments. This two steps correction method is simple to use and personalized to each patient's anatomy. It can easily be adapted to any dynamic TBI techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pathogenesis of virulent and attenuated foot-and-mouth disease virus in cattle

Background: Understanding the mechanisms of attenuation and virulence of foot-and-mouth disease virus (FMDV) in the natural host species is critical for development of next-generation countermeasures such as live-attenuated vaccines. Functional genomics analyses of FMDV have identified few virulence factors of which the leader proteinase (Lpro) is the most thoroughly investigated. Previous work from our laboratory has characterized host factors in cattle inoculated with virulent FMDV and attenuated mutant strains with transposon insertions within Lpro. Methods: In the current study, the characteristics defining virulence of FMDV in cattle were further investigated by comparing the pathogenesis of a mutant, attenuated strain (FMDV-Mut) to the parental, virulent virus from which the mutant was derived (FMDV-WT). The only difference between the two viruses was an insertion mutation in the inter-AUG region of the leader proteinase of FMDV-Mut. All cattle were infected by simulated-natural, aerosol inoculation. Results: Both viruses were demonstrated to establish primary infection in the nasopharyngeal mucosa with subsequent dissemination to the lungs. Immunomicroscopic localization of FMDV antigens indicated that both viruses infected superficial epithelial cells of the nasopharynx and lungs. The critical differences between the two viruses were a more rapid establishment of infection by FMDV-WT and quantitatively greater virus loads in secretions and infected tissues compared to FMDV-Mut. The slower replicating FMDV-Mut established a subclinical infection that was limited to respiratory epithelial sites, whereas the faster replication of FMDV-WT facilitated establishment of viremia, systemic dissemination of infection, and clinical disease. Conclusion: The mutant FMDV was capable of achieving all the same early pathogenesis landmarks as FMDV-WT, but was unable to establish systemic infection. The precise mechanism of attenuation remains undetermined; but current data suggests that the impaired replication of the mutant is more responsible for attenuation than differences in host immunological factors. These results complement previous studies by providing data of high-granularity describing tissue-specific tropism of FMDV and by demonstrating microscopic localization of virulent and attenuated clones of the same field-strain FMDV.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing dust attenuation in local star-forming galaxies: UV and optical reddening

The dust attenuation for a sample of ∼10,000 local (z ≲ 0.1) star-forming galaxies is constrained as a function of their physical properties. We utilize aperture-matched multiwavelength data available from the Galaxy Evolution Explorer and the Sloan Digital Sky Survey to ensure that regions of comparable size in each galaxy are being analyzed. We follow the method of Calzetti et al. and characterize the dust attenuation through the UV power-law index, β, and the dust optical depth, which is quantified using the difference in Balmer emission line optical depth, τ{sub B}{sup l}=τ{sub Hβ}−τ{sub Hα}. The observed linear relationship between β and τ{sub B}{sup l} is similar to the local starburst relation, but the large scatter (σ{sub int} = 0.44) suggests that there is significant variation in the local universe. We derive a selective attenuation curve over the range 1250 Å < λ < 8320 Å and find that a single attenuation curve is effective for characterizing the majority of galaxies in our sample. This curve has a slightly lower selective attenuation in the UV compared to previously determined curves. We do not see evidence to suggest that a 2175 Å feature is significant in the average attenuation curve. Significant positive correlations are seen between the amount of UV and optical reddening and galaxy metallicity, mass, star formation rate (SFR), and SFR surface density. This provides a potential tool for gauging attenuation where the stellar population is unresolved, such as at high z.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic measurements of the far-ultraviolet dust attenuation curve at z ∼ 3

We present the first spectroscopic measurements of the shape of the far-ultraviolet (far-UV; λ=950--1500 Å) dust attenuation curve at high redshift (z∼3). Our analysis employs rest-frame UV spectra of 933 galaxies at z∼3, 121 of which have very deep spectroscopic observations (≳7 hr) at λ=850--1300 A-ring , with the Low Resolution Imaging Spectrograph on the Keck Telescope. By using an iterative approach in which we calculate the ratios of composite spectra in different bins of continuum color excess, E(B−V), we derive a dust curve that implies a lower attenuation in the far-UV for a given E(B−V) than those obtained with standard attenuation curves. We demonstrate that the UV composite spectra of z∼3 galaxies can be modeled well by assuming our new attenuation curve, a high covering fraction of H i, and absorption from the Lyman–Werner bands of H{sub 2} with a small (≲20%) covering fraction. The low covering fraction of H{sub 2} relative to that of the H I and dust suggests that most of the dust in the ISM of typical galaxies at z∼3 is unrelated to the catalysis of H{sub 2}, and is associated with other phases of the ISM (i.e., the ionized and neutral gas). The far-UV dust curve implies a factor of ≈2 lower dust attenuation of Lyman continuum (ionizing) photons relative to those inferred from the most commonly assumed attenuation curves for L* galaxies at z∼3. Our results may be utilized to assess the degree to which ionizing photons are attenuated in H ii regions or, more generally, in the ionized or low column density (N(H I)≲10{sup 17.2} cm{sup −2}) neutral ISM of high-redshift galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Lateral noise-attenuation results from flyovers of three transport aircraft

Lateral noise-attenuation data have been compiled in a one-third-octave-band analysis from an available set of flyover tests using DC-8, DC-9, and DC-10 aircraft. For an intermediate frequency range of 400 through 2000 Hertz the lateral noise has been approximately separated into its two components - the excess ground attenuation and the aircraft shielding attenuation. Both attenuation factors varied from a maximum at small elevation angles to zero at an elevation angle of approximately 40 degrees. The lateral attenuation in this range generally did not vary with frequency. For frequencies of 80 Hertz and lower, negative lateral attenuation values were obtained. For high frequencies, the data were not complete enough to generate definitive lateral attenuation curves.

Mashita, E. M.↗

C-band attenuation by tropical rainfall in Darwin, Australia, using climatologically tuned Z(e)-R relations

The probability matching method (PMM) is used as a basis for estimating attenuation in tropical rains near Darwin, Australia. PMM provides a climatological relationship between measured radar reflectivity and rain rate, which includes the effects of rain and cloud attenuation. When the radar sample is representative, PMM estimates the rainfall without bias. When the data are stratified for greater than average rates, the method no longer compensates for the higher attenuation and the radar rainfall estimates are biased low. The uncompensated attenuation is used to estimate the climatological attenuation coefficient. The two-way attenuation coefficient was found to be 0.0085 dB/km ( mm/h) exp -1.08 for the tropical rains and associated clouds in Darwin for the first two months of the year for horizontally polarized radiation at 5.63 GHz. This unusually large value is discussed. The risks of making real-time corrections for attenuation are also treated.

Atlas, David↗

Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0{sup o} and sub-0{sup o}C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0{sup o}C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of transmission line attenuation in broad band millimeter wave frequency range

Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic wave attenuation measurements in a ring-shaped inductively coupled air plasma

An aerocraft with the surface, inlet and radome covered large-area inductive coupled plasma (ICP) can attenuate its radar echo effectively. The shape, thickness, and electron density (N{sub e}) distribution of ICP are critical to electromagnetic wave attenuation. In the paper, an air all-quartz ICP generator in size of 20 × 20 × 7 cm{sup 3} without magnetic confinement is designed. The discharge results show that the ICP is amorphous in E-mode and ring-shaped in H-mode. The structure of ICP stratifies into core region and edge halo in H-mode, and its width and thickness changes from power and pressure. Such phenomena are explained by the distribution of RF magnetic field, the diffusion of negative ions plasma and the variation of skin depth. In addition, the theoretical analysis shows that the N{sub e} achieves nearly uniform within the electronegative core and sharply steepens in the edge. The N{sub e} of core region is diagnosed by microwave interferometer under varied conditions (pressure in range of 10–50 Pa, power in 300–700 W). Furthermore, the electromagnetic wave attenuation measurements were carried out with the air ICP in the frequencies of 4–5 GHz. The results show that the interspaced ICP is still effective to wave attenuation, and the wave attenuation increases with the power and pressure. The measured attenuation is approximately in accordance with the calculation data of finite-different time-domain simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ultraviolet attenuation law in backlit spiral galaxies

The effective extinction law (attenuation behavior) in galaxies in the emitted ultraviolet (UV) regime is well known only for actively star-forming objects and combines effects of the grain properties, fine structure in the dust distribution, and relative distributions of stars and dust. We use Galaxy Evolution Explorer, XMM Optical Monitor, and Hubble Space Telescope (HST) data to explore the UV attenuation in the outer parts of spiral disks which are backlit by other UV-bright galaxies, starting with the candidate list of pairs provided by Galaxy Zoo participants. New optical images help to constrain the geometry and structure of the target galaxies. Our analysis incorporates galaxy symmetry, using non-overlapping regions of each galaxy to derive error estimates on the attenuation measurements. The entire sample has an attenuation law across the optical and UV that is close to the Calzetti et al. form; the UV slope for the overall sample is substantially shallower than found by Wild et al., which is a reasonable match to the more distant galaxies in our sample but not to the weighted combination including NGC 2207. The nearby, bright spiral NGC 2207 alone gives an accuracy almost equal to the rest of our sample, and its outer arms have a very low level of foreground starlight. Thus, this widespread, fairly 'gray' law can be produced from the distribution of dust alone, without a necessary contribution from differential escape of stars from dense clouds. Our results indicate that the extrapolation needed to compare attenuation between backlit galaxies at moderate redshifts from HST data, and local systems from Sloan Digital Sky Survey and similar data, is mild enough to allow the use of galaxy overlaps to trace the cosmic history of dust in galaxies. For NGC 2207, HST data in the near-UV F336W band show that the covering factor of clouds with small optical attenuation becomes a dominant factor farther into the UV, which opens the possibility that widespread diffuse dust dominates over dust in star-forming regions deep into the UV. Comparison with published radiative-transfer models indicates that the role of dust clumping dominates over differences in grain populations at this coarse spatial resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation framework

Purpose: The purpose of this work is to introduce a new device that allows for patient-specific imaging-dose modulation in conventional and cone-beam CT. The device is called a digital beam attenuator (DBA). The DBA modulates an x-ray beam by varying the attenuation of a set of attenuating wedge filters across the fan angle. The ability to modulate the imaging dose across the fan beam represents another stride in the direction of personalized medicine. With the DBA, imaging dose can be tailored for a given patient anatomy, or even tailored to provide signal-to-noise ratio enhancement within a region of interest. This modulation enables decreases in: dose, scatter, detector dynamic range requirements, and noise nonuniformities. In addition to introducing the DBA, the simulation framework used to study the DBA under different configurations is presented. Finally, a detailed study on the choice of the material used to build the DBA is presented. Methods: To change the attenuator thickness, the authors propose to use an overlapping wedge design. In this design, for each wedge pair, one wedge is held stationary and another wedge is moved over the stationary wedge. The composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. To validate the DBA concept and study design changes, a simulation environment was constructed. The environment allows for changes to system geometry, different source spectra, DBA wedge design modifications, and supports both voxelized and analytic phantom models. A study of all the elements from atomic number 1 to 92 were evaluated for use as DBA filter material. The amount of dynamic range and tube loading for each element were calculated for various DBA designs. Tube loading was calculated by comparing the attenuation of the DBA at its minimum attenuation position to a filtered non-DBA acquisition. Results: The design and parametrization of DBA implemented FFMCT has been introduced. A simulation framework was presented with which DBA-FFMCT, bowtie filter CT acquisitions, and unmodulated CT acquisitions can be simulated. The study on wedge filter design concluded that the ideal filter material should have an atomic number in the range of 21-34. Iron was chosen for an experimental relative-tube-loading measurement and showed that DBA-FFMCT scans could be acquired with negligible increases in tube power demands. Conclusions: The basic idea of DBA implemented fluence field modulated CT, a simulation framework to verify the concept, and a filter selection study have been presented. The use of a DBA represents another step toward the ultimate in patient specific CT dose delivery as patient dose can be delivered uniquely as a function of view and fan angle using this device.

60 APPLIED LIFE SCIENCES↗

SU-E-T-137: Attenuation of Carbon Fiber IGRT Couch Top for SBRT By Using a MapCheck 2 and Ion Chamber

Purpose: It is common to use posterior oblique beams in intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) for regular and stereotactic body radiotherapy (SBRT). Beam attenuation by the treatment couch is not negligible when the couch is in the beam portal. In this study, we have correlated relative dose versus beam angle through a MapCheck 2TM diode array and an ionization chamber measurement. Methods: A Varian TrueBeam linear accelerator equipped with the image-guided radiation therapy (IGRT) carbon fiber couch was used for delivery of radiation with different photon energies of 6MV, 15MV and 6MV FFF. A MapCHECK 2TM diode array with a MapPhan was employed for the measurement at three field sizes (3 by 3, 5 by 5, and 10 by 10 cm). The independent measurement was performed with an ionization chamber placed at the center of an acrylic cylindrical phantom at the isocenter. The measured data with the MapCHECK 2TM diode array were averaged over the central 2×2 cm diodes for each measurement. The couch attenuation was deduced from the angular dependence with and without the couch involvement. Results: For the MapCHECK 2TM with MapPhan used only the obvious attenuation was observed at the beam angle between 5 and 10 degree from the angular dependence using a 6MV photon beam. The similar Result was obtained for the MapCHECK 2TM /MapPhan with the couch involvement. The couch attenuation was then deduced from the difference of these two sets of data measurements. Maximum couch attenuation was found up to 4.2% which was verified with the ion chamber measurement. Conclusion: A maximum attenuation of 4.2% was found for the carbon fiber couch top using the MapCHECK 2TM/MapPhan, which is consistent with the ion chamber measurement.

60 APPLIED LIFE SCIENCES↗

SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

60 APPLIED LIFE SCIENCES↗