Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atmospheric pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-electrode/multi-modal atmospheric pressure glow discharge plasma ionization device

Apparatus include an atmospheric pressure glow discharge (APGD) analyte electrode defining an analyte discharge axis into an APGD volume, and a plurality of APGD counter electrodes having respective electrical discharge ends directed to the APGD volume, wherein the APGD analyte electrode and the APGD counter electrodes are configured to produce an APGD plasma in the APGD volume with a voltage difference between the APGD analyte electrode and one or more of the AGPD counter electrodes. An electrode can be integrated into an ion inlet. Apparatus can be configured to perform auto-ignition and/or provide multi-modal operation through selectively powering electrodes. Electrode holder devices are disclosed. Related methods are disclosed.

Koppenaal, David W.↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineering a laser remote sensor for atmospheric pressure and temperature

A system for the remote sensing of atmospheric pressure and temperature is described. Resonant lines in the 7600 Angstrom oxygen A band region are used and an organic dye laser beam is tuned to measure line absorption changes with temperature or pressure. A reference beam outside this band is also transmitted for calibration. Using lidar techniques, profiling of these parameters with altitude can be accomplished.

Kalshoven, J. E., Jr.↗

Atmospheric Pressure Plasma Jet as a Dry Alternative to Inkjet Printing in Flexible Electronics

We have developed an atmospheric pressure plasma jet printing system that works at room temperature to 50 deg C unlike conventional aerosol assisted techniques which require a high temperature sintering step to obtain desired thin films. Multiple jets can be configured to increase throughput or to deposit multiple materials, and the jet(s) can be moved across large areas using a x-y stage. The plasma jet has been used to deposit carbon nanotubes, graphene, silver nanowires, copper nanoparticles and other materials on substrates such as paper, cotton, plastic and thin metal foils.

Printable electronics↗

Optical and mass-spectral characterization of mixed-gas flowing atmospheric-pressure afterglow sources

Plasma-based ambient desorption/ionization (ADI) sources for mass spectrometry (MS) often use helium as the primary discharge gas due to the large reaction cross section of excited helium species with atmospheric gases, which ultimately leads to efficient reagent-ion formation. However, some studies have shown that mixed-gas plasmas provide unique advantages. For instance, our group showed that a helium-oxygen flowing atmospheric-pressure afterglow (He:O 2 -FAPA) source yielded enhanced ion signals for small polar analytes, but compounds with aromatic rings underwent chemical modification to produce pyrylium species. Here, it is shown that the addition of H 2 to the helium FAPA gas significantly decreased the reagent-ion signals, but analyte-ion signal was not affected to the same degree. In addition, mass spectra obtained with He:H 2 -FAPA were chemically cleaner with fewer ions stemming from analyte species and produced less oxidation of analytes. Addition of nitrogen increased the abundance of negative reagent ions (e.g., NO 2 - and NO 3 - ) which led to enhanced ion signal for RDX. To better understand these unique advantages of a mixed-gas FAPA, the impact of molecular-gas (O 2 , N 2 , or H 2 ) addition on the optical-emission spectra from the discharge was also measured. Spatially resolved emission was obtained from the anode- and negative-glow regions. In general, addition of small fractions (~0.1%) of molecular gases decreased helium and OH emission intensities. Atomic oxygen and hydrogen emission increased with the addition of O 2 and H 2 , respectively. Furthermore, emission characteristics of N 2 , N 2 + , and NO with respect to molecular gas composition on He-FAPA were measured. Finally, fundamental plasma parameters, such as OH rotational temperature (T rot ), were also calculated for these mixed-gas systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer↗

Remote sensing of atmospheric pressure and sea state using laser altimeters

Short-pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak-tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems have been used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

Gardner, C. S.↗

Remote sensing of atmospheric pressure and sea state from satellites using short-pulse multicolor laser altimeters

Short pulse multicolor laser ranging systems are currently being developed for satellite ranging applications. These systems use Q-switched pulsed lasers and streak tube cameras to provide timing accuracies approaching a few picoseconds. Satellite laser ranging systems was used to evaluate many important geophysical phenomena such as fault motion, polar motion and solid earth tides, by measuring the orbital perturbations of retroreflector equipped satellites. Some existing operational systems provide range resolution approaching a few millimeters. There is currently considerable interest in adapting these highly accurate systems for use as airborne and satellite based altimeters. Potential applications include the measurement of sea state, ground topography and atmospheric pressure. This paper reviews recent progress in the development of multicolor laser altimeters for use in monitoring sea state and atmospheric pressure.

Gardner, C. S.↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spatially resolved absolute densities of reactive species and positive ion flux in He-O 2 RF-driven atmospheric pressure plasma jet: touching and non-touching with dielectric substrate

Atmospheric pressure plasma jets (APPJs) are operating in direct contact with dielectric substrates for many applications. Nonetheless, many studies have been focusing on free jets. In this letter, we report spatially resolved measurements of reactive species including neutral and ionic species in an He + 1% O 2 RF-driven APPJ by molecular beam mass spectrometry equipped with a dielectric sampling plate, enabling to detect species densities for APPJ operating remotely or in direct contact with a substrate. Here, the spatially resolved distribution of O, O 2 (a 1 Δ g ) and O 3 is dominated by convection and, remarkably, shows minimum differences between touching and non-touching conditions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Absolute atomic hydrogen density measurements in an atmospheric pressure plasma jet: generation, transport and recombination from the active discharge region to the effluent

Atomic hydrogen (H) generated by atmospheric pressure radio frequency (RF) plasma jet is investigated by two-photon absorption laser induced fluorescence in a He-H 2 mixture. The reported time and spatially resolved H density profiles enable a detailed analysis of the species generation, transport and decay along the axis of symmetry of the jet. Here, the H density distribution for a continuous RF plasma jet corresponds well with the outcome of a Pseudo-1D plug flow model. In addition, RF power modulation has a strong effect on the H density in the active discharge region but has a negligible effect on the H density in the far effluent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The charge reduction rate for multiply charged polymer ions via ion–ion recombination at atmospheric pressure

The charge reduction of multiply charged macromolecular ions via recombination with small ions in the gas phase is commonly employed to modulate the charge on macromolecules prior to mass spectrometric and mobility analyses. We employ a recently developed continuum-Molecular Dynamics (MD) calculation approach to determine the recombination rate coefficient of multiply charged (1 to 7 excess positive charged) polyethylene glycol ions (mass of 4600 Da) with smaller singly charged anions, modeled as NO 2 – ions. The continuum-MD approach accounts explicitly for the influence of the background gas on the recombination process, accounts explicitly for ion translational, vibrational, and rotational motion, and enables recombination rate coefficient calculation in nitrogen near atmospheric pressure, wherein neither low pressure nor high pressure recombination theories are strictly applicable. Continuum-MD simulations yield recombination rate coefficients near 3.9 × 10 –14 m 3 s –1 for singly charged ions, increasing to 3.0 × 10 –11 m 3 s –1 for the +7 ion. Pre-existing collision rate coefficient expressions for rigid ions are found to be within a factor of 2–5 of calculations for all charge states, but their use requires knowledge of an appropriate collision distance, which is not well-defined for flexible polymer ions. Continuum-MD-inferred rate coefficients are incorporated into a model of charge reduction, and the charge state distribution versus anion concentration determined with it is compared to charge reduction measurements made via atmospheric pressure differential mobility analysis. Furthermore, good agreement is observed between simulations and experiments; although results are extremely sensitive to the recombination rate coefficients, experimental results are bound by models utilizing rates within a factor of 2 (0.5–2.0×) of the continuum-MD rates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microwave Atmospheric-Pressure Sensor

Report describes tests of microwave pressure sounder (MPS) for use in satellite measurements of atmospheric pressure. MPS is multifrequency radar operating between 25 and 80 GHz. Determines signal absorption over vertical path through atmosphere by measuring strength of echoes from ocean surface. MPS operates with cloud cover, and suitable for use on current meteorological satellites.

Flower, D. A.↗