Effect of simulated hyperemia on the flow field in a mildly atherosclerotic coronary artery casting of man

Changes in an arterial flow field due to mild atherosclerosis were determined using a main coronary artery casting with a maximum obstruction of about 50 percent by area. Local pressure changes were measured using six pressure tap holes along the wall of the casting. The test-fluid was a 33 percent sugar-water solution of approximately the same viscosity as human blood. Flow visualization results were obtained by injecting blue-dye through the pressure tap holes. Measurement of local pressure demonstrated a significant Reynolds number effect. At Reynolds numbers of 80-710, a local pressure rise was observed downstream of the mild atherosclerotic constriction due to momentum changes. The Reynolds number necessary for flow separation in the divergent region of the coronary casting was about 330. The experimental results can be used to obtain a quantitative relation between coronary morphology and the fluid dynamic consequences of mild diffuse disease under conditions of maximum cardiac demand i.e., higher coronary flow rates and Reynolds numbers associated with space and atmospheric flight.

Cho, Y. I.↗

Fluid particle motion and Lagrangian velocities for pulsatile flow through a femoral artery branch model

A flow visualization study using selective dye injection and frame by frame analysis of a movie provided qualitative and quantitative data on the motion of marked fluid particles in a 60 degree artery branch model for simulation of physiological femoral artery flow. Physical flow features observed included jetting of the branch flow into the main lumen during the brief reverse flow period, flow separation along the main lumen wall during the near zero flow phase of diastole when the core flow was in the downstream direction, and inference of flow separation conditions along the wall opposite the branch later in systole at higher branch flow ratios. There were many similarities between dye particle motions in pulsatile flow and the comparative steady flow observations.

Cho, Y. I.↗

Flows In Model Human Femoral Arteries

Flow is visualized with dye traces, and pressure measurements made. Report describes experimental study of flow in models of human femoral artery. Conducted to examine effect of slight curvature of artery on flow paths and distribution of pressure.

Back, Lloyd H.↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

Experiments On Flow In A Coronary Artery

Report describes experiments on simulated flow of blood in atherosclerotic human coronary artery. Experiments performed on polyurethane cast made from S-shaped coronary artery of cadaver. Sucrose solution with viscosity of blood pumped through cast at physiologically realistic rates, and flow made pulsatile by mechanism alternately compressing and releasing elastic tube just upstream of cast.

Back, Lloyd H.↗

Decreased femoral arterial flow during simulated microgravity in the rat

To determine whether the blood supply to the hindlimbs of rats is altered by the tail-suspension model of weightlessness, rats were chronically instrumented for the measurement of femoral artery flow. Ultrasonic transit-time flow probes were implanted into 8-wk-old Wistar-Furth rats under ketamine-xylazine anesthesia, and, after 24 h of recovery, flow was measured in the normal ambulatory posture. Next, rats were suspended and flow was measured immediately and then daily over the next 4-7 days. Rats were subsequently returned to normal posture, and flow was monitored daily for 1-3 days. Mean arterial flow decreased immediately on the rats being suspensed and continued to decrease until a new steady state of approximately 60% of control values was attained at 5 days. On the rats returning to normal posture, flow increased to levels observed before suspension. Quantile-quantile plots of blood flow data revealed a decrease in flow during both systole and diastole. The observed decrease in hindlimb blood flow during suspension suggests a possible role in the etiology of muscular atrophy and bone loss in microgravity.

Roer, Robert D.↗

Effects of Sustained Low-Level Elevations of Carbon Dioxide on Cerebral Blood Flow and Autoregulation of the Intracerebral Arteries in Humans

Cerebral blood flow velocity (CBFv) was measured by insonating the middle cerebral arteries of 4 subjects using a 2 Mhz transcranial Doppler. Ambient CO2 was elevated to 0.7% for 23 days in the first study and to 1.2% for 23 days in the same subjects in the second study. By non-parametric testing CBFv was elevated significantly by +35% above pre-exposure levels during the first 1-3 days at both exposure levels after which CBFv progressively readjusted to pre-exposure levels. Despite similar CBFv responses, headache was only reported during the initial phase of exposure to 1.2% CO2. Vascular reactivity to CO2 assessed by rebreathing showed a similar pattern with the CBFv increases early in the exposures being greater than those elicited later. An increase in metabolic rate of the visual cortex was evoked by having the subjects open and close their eyes during a visual stimulus. Evoked CBFv responses measured in the posterior cerebral artery were also elevated in the first 1-3 days of both studies returning to pre-exposure levels as hypercapnia continued. Cerebral vascular autoregulation assessed by raising head pressure during 10 deg head-down tilt both during the low-level exposures and during rebreathing was unaltered. There were no changes in the retinal microcirculation during serial fundoscopy studies. The time-dependent changes in CO2 vascular reactivity might be due either to retention of bicarbonate in brain extracellular fluid or to progressive increases in ventilation, or both. Cerebral vascular autoregulation appears preserved during chronic exposure to these levels of ambient CO2.

Sliwka, U.↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

A fluid--structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery

A new model is used to analyze the fully coupled problem of pulsatile blood flow through a compliant, axisymmetric stenotic artery using the finite element method. The model uses large displacement and large strain theory for the solid, and the full Navier-Stokes equations for the fluid. The effect of increasing area reduction on fluid dynamic and structural stresses is presented. Results show that pressure drop, peak wall shear stress, and maximum principal stress in the lesion all increase dramatically as the area reduction in the stenosis is increased from 51 to 89 percent. Further reductions in stenosis cross-sectional area, however, produce relatively little additional change in these parameters due to a concomitant reduction in flow rate caused by the losses in the constriction. Inner wall hoop stretch amplitude just distal to the stenosis also increases with increasing stenosis severity, as downstream pressures are reduced to a physiological minimum. The contraction of the artery distal to the stenosis generates a significant compressive stress on the downstream shoulder of the lesion. Dynamic narrowing of the stenosis is also seen, further augmenting area constriction at times of peak flow. Pressure drop results are found to compare well to an experimentally based theoretical curve, despite the assumption of laminar flow.

Non-NASA Center↗

A Primary Care Approach to the Diagnosis and Management of Peripheral Arterial Disease

The objectives of this work are: (1) Be able to recognize characteristic symptoms of intermittent claudication (2) Diagnose PAD on the basis of history, physical exam, and simple limb blood pressure measurements (3) Recognize the significance of peripheral artery disease as a marker for coronary or cerebrovascular atherosclerosis (4) Provide appropriate medical management of atherosclerosis risk factors-- including use of antiplatelet therapy to reduce risk of myocardial infarction, stroke and death (5) Manage symptoms of intermittent claudication with program of smoking cessation, exercise, and medication The diagnosis of intermittent claudication secondary to peripheral artery disease (PAD) can often be made on the basis of history and physical examination. Additional evaluation of PAD is multi-modal and the techniques used will vary depending on the nature and severity of the patient's presenting problem. Most patients can be appropriately managed without referral for specialized diagnostic services or interventions.

Dawson, David L.↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure syndrome (VIIP) is a newly described space flight-associated medical condition made up of a constellation of symptoms affecting at least 34% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures, and is thought to be related to elevated intracranial pressure secondary to space flightinduced cephalad fluid shifts. Loss of visual acuity could be a significant threat to crew health and performance and may be suggestive of other adaptations with implications for years post-flight. Our primary objective is to determine whether vascular compliance is altered by space flight and whether such adaptations are related to the incidence of VIIP. In particular, we will measure ocular parameters and vascular compliance in vessels of the head and neck in astronauts who have no space flight experience, in astronauts before, during, and after space flight, and in bed rest subjects with conditions similar to space flight. Additionally, we will analyze astronaut data from the Lifetime Surveillance of Astronaut Health (LSAH) archive to determine which factors might be predictive of the development of VIIP. The project will be conducted in four separate but related parts. To understand the baseline condition of astronauts without any prior space flight experience, we will study 10 astronauts who have never flown in space by performing a comprehensive evaluation of the vasculature of the head, neck and eyes. Hemodynamic data (stroke volume and blood pressure), ocular (tonometry and ocular ultrasound), venous and arterial parameters will be acquired across a range of tilt angles (20, 10, 0, -10, -20 degrees). Vessels to be studied include the temporal, jugular, and vertebral veins and the cerebral, carotid and vertebral arteries. Ophthalmic data from the annual physical will be obtained through data sharing. To examine the relation between vascular compliance in the head and neck and the development of VIIP after a long duration space flight, we will study 10 astronauts before, during, and after long-duration ISS missions. Pre- and post-flight testing will be identical to that described above. During flight, images of the same vessels of interest will be obtained for later analysis. Ophthalmic data including VIIP scores will be obtained through data sharing from medically-required tests. To investigate the effects of age and elevated sodium intake, two potential contributors to VIIP, we will study 24 men (in two age groups: 25-35 and 45-55) during a 14 day 6deg head-down bed rest, a well-accepted analog of space flight. Standard NASA bed rest conditions will be maintained except for dietary sodium. Sodium intake will be similar to that of ISS astronauts, which is higher than consumed in previous bed rest studies. Pre- and post-bed rest testing procedures will be identical to the testing protocol described above for astronauts. Ophthalmic testing (optical coherence tomography, fundoscopy, and tonometry) will be conducted on the same day that vascular compliance measures are obtained. To identify parameters that may relate to an increase in an astronaut's susceptibility to developing VIIP, we will use data mining techniques to evaluate astronaut data obtained from the LSAH. Medical history, family history, space flight history and its related exposures, and history of high performance jet aircraft exposure will be examined for their potential relationship to ocular data. We hypothesize that the cephalad fluid shift induced by space flight will result in structural and functional adaptations in head and neck vessels leading to decreased vascular compliance and related to the development of VIIP symptoms. Further, although VIIP has not been observed in previous bed rest studies, we hypothesize that an elevated sodium intake will increase the incidence of VIIP symptoms in this space flight analog. Finally, we hypothesize that data mining analyses will reveal relationships between health history, previous exposures (including space flight and high performance aircraft), and the development of VIIP in the astronaut population.

Ribeiro, L. C.↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance in Astronants

1. Project Overview Visual impairment and intracranial pressure (VIIP) is a spaceflight-associated medical condition affecting at least a third of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures. In some astronauts, eye-related changes do not revert back to the preflight state upon return to Earth. Our team will study some of the possible causes for this syndrome. This will be achieved by reviewing previous astronaut data for factors that may predispose astronauts to higher rates of developing this syndrome or greater severity of symptoms. Additionally, we will conduct 3 separate experiments that will characterize vessels in the head and neck and measure the effects of the experimental conditions on ocular structures and function. 2. Technical Summary The primary objective of this study is to determine whether vascular compliance is altered by spaceflight and whether such adaptations are related to the incidence of the VIIP. In particular, we will measure ocular parameters and vascular compliance in vessels of the head and neck in astronauts who have no spaceflight experience (Ground), in astronauts before, during, and after spaceflight (Flight), and in bed rest subjects with conditions similar to spaceflight (Bed Rest). Additionally, we will analyze astronaut data from the Lifetime Surveillance of Astronaut Health (LSAH) archives to determine which factors might be predictive of the development of VIIP (Data Mining). The project will be conducted in four separate, but related parts. Hypothesis The central hypothesis of this proposal is that exposure to the spaceflight environment aboard the ISS may lead to development of the VIIP syndrome (increased intracranial pressure and impaired visual acuity) and that this may be related to alterations in venous and/or arterial compliance in the head and neck. Specific Aims 1. To determine whether noninvasive measures of venous and arterial compliance are altered by long-duration spaceflight exposure in ISS astronauts and whether these changes are related to the development of the VIIP syndrome. (Flight) 2. To determine whether previous spaceflight experience predispose astronauts to lower venous compliance and/or the development of the VIIP syndrome. (Ground + Flight) 3. To use a 14-day, 6deg head-down-tilt bed rest as a model of spaceflight, to evaluate the effect of aging on vascular compliance using a subject population similar to younger (25-35 yr) and older (45-55 yr) astronaut cohorts. (Bed Rest) 4. To determine what factors contribute to lower venous compliance and/or the development of the VIIP syndrome in astronauts. (Data Mining) 3. Earth Applications This research may inform the mechanisms that regulate blood/fluid flow in and out of the brain in the head and neck. This information may help with understanding of the mechanisms behind idiopathic intracranial hypertension. 4. Link to NASA Taskbook Entry Not Yet Available

Platts, Steven↗

NASA Screening and Clinical Practice for the Monitoring and Mitigation of Coronary Artery Disease: Application to Terrestrial Practice

Coronary artery disease (CAD) surveillance has led to the development of risk stratification tools that drive clinical mitigation efforts for CAD risk. As common risk assessment tools, including the Framingham Risk Score (FRS) or Pooled Cohort Risk Equations, have insufficient accuracy on an individual level to meet NASA’s stringent screening guidelines, NASA has required new approaches to address the risk of catastrophic cardiovascular (CV) medical events among astronauts. Coronary artery calcium (CAC) scanning has emerged as the current best tool to enhance CV risk assessment in asymptomatic individuals, with risk information incremental to FRS data.

Khera, Amit↗