Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Tech Briefs, July 2008

Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.

Source record↗

Phase-change Reconfigurable Optical WavEfront Synthesis System (PROWESS)

We report the design, fabrication, and testing of electrically tunable metasurface k-space filters based on the low-loss, high-contrast phase-change material GSST and a transparent Si electrode heating architecture. A 10x10 array of PCM elements integrated with Si heaters was fabricated via foundry processes, and used to actively control the crystallinity of a metasurface consisting of GSST nano antennae. By selectively varying the structural state of individual PCM elements, specific k-vectors of transmitted light can effectively be filtered out, resulting in improved imaging quality by reducing the scattered light that reaches a detector. Optimized doping profiles in the Si heaters allow for uniform, low power, reliable and repeatable switching of the GSST state. Compared to other k-space filters, this new architecture is completely transparent to the wavelength of interest and can be actively reconfigured in real time with high performance, low power consumption and a small footprint. The 10x10 array device is a proof-of-concept demonstration that can enable high-resolution arbitrary wavefront synthesis and correction in the future, with key applications in optical communications, beam steering, remote sensing, and adaptive optics.

phase change material↗

Properties criteria for components and materials used in lightweight solar arrays

The present work describes the characteristics and design criteria for components and materials used in lightweight substrate solar arrays. This includes descriptions of wraparound-electrode solar cells, cell covers, and cell interconnects. Cell cover systems briefly discussed are fused silica, cerium stabilized glass, microsheet, FEP (tape, heat laminated, and spray on), and ESB 7070 glass integral covers. The majority of solar arrays orbited have used either silver, Kovar, copper, or molybdenum as interconnect metals. Data are presented comparing the Young's modulus E, ultimate tensile strength, coefficient of expansion, thermal conductivity, and percent elongation of these and other interconnect candidate materials. Guidelines for the use of end tab wraparound cells are listed.

Lott, D. R.↗

E-tongue 2 REDOX response to heavy metals

E-Tongue 2 an array of electrochemical sensors including REDOX electrodes for Cylic Voltammetry and Anodic Stripping Voltammetry measurements, Galvanic cells for corrosion measurements, and Ion Selective Electrodes.

electromechanical sensors↗

Self-protected electrodes limit field-emission current

One cathode includes array of square-shaped conductor columns. Columns are electrically interconnected by conducting plate on bottom. Each column provides field-emission current. Another cathode includes array of rodlike conductors. Layer is covered by control film made of conducting material. Film is isolated from each conductor.

Lees, W. L.↗

Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy

A next-generation microshutter array, LArge Microshutter Array (LAMA), was developed as a multi-object field selector. LAMA consists of small-scaled microshutter arrays that can be combined to form large-scale microshutter array mosaics. Microshutter actuation is accomplished via electrostatic attraction between the shutter and a counter electrode, and 2D addressing can be accomplished by applying an electrostatic potential between a row of shutters and a column, orthogonal to the row, of counter electrodes. Microelectromechanical system (MEMS) technology is used to fabricate the microshutter arrays. The main feature of the microshutter device is to use a set of standard surface micromachining processes for device fabrication. Electrostatic actuation is used to eliminate the need for macromechanical magnet actuating components. A simplified electrostatic actuation with no macro components (e.g. moving magnets) required for actuation and latching of the shutters will make the microshutter arrays robust and less prone to mechanical failure. Smaller-size individual arrays will help to increase the yield and thus reduce the cost and improve robustness of the fabrication process. Reducing the size of the individual shutter array to about one square inch and building the large-scale mosaics by tiling these smaller-size arrays would further help to reduce the cost of the device due to the higher yield of smaller devices. The LAMA development is based on prior experience acquired while developing microshutter arrays for the James Webb Space Telescope (JWST), but it will have different features. The LAMA modular design permits large-format mosaicking to cover a field of view at least 50 times larger than JWST MSA. The LAMA electrostatic, instead of magnetic, actuation enables operation cycles at least 100 times faster and a mass significantly smaller compared to JWST MSA. Also, standard surface micromachining technology will simplify the fabrication process, increasing yield and reducing cost.

Moseley, Samuel↗

Carbon Nanofiber Nanoelectrode Arrays for Neural Implant Devices

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

carbon nanotubes↗

Fluctuations and turbulence in an electric field Bumpy Torus plasma

Fluctuation characteristics of plasma number density and electrostatic potential below the ion plasma and ion cyclotron frequencies in an electric field Bumpy Torus plasma were investigated experimentally, using digitally implemented spectral analysis techniques. The toroidal plasma was biased to high potentials by applying positive or negative voltage to electrodes located in the midplanes of two sectors of the toroidal array. The plasma was observed to be biased to 80 or 90% of the potential on the midplane electrodes, regardless of polarity. The radial electric field exceeded 1 kV/cm at the plasma boundary and penetrated inward to at least one-half of the plasma radius. When the imposed radial electric fields reached values characteristic of the experiment, the E/B drift velocities were comparable to the particle thermal velocities. The amplitude statistics of both the density and the potential fluctuations were found to be Gaussian for the most part, with near-zero skewness and a kurtosis of about 3.0. The spectral index of the density and potential fluctuations ranged from 2 to 6. The higher frequency components were found to propagate faster than the E/B drift velocity, which is the characteristic speed of the lower-frequency components.

Roth, J. R.↗

Linear charge coupled device detector array for imaging light propagating in an integrated thin-film optical waveguide

Device design, fabrication, and operation of a linear charge coupled device (CCD) detector array integrated with a thin film optical waveguide and applications of this structure to integrated optical signal processing and fiber optical communications were discussed. A two phase, overlapping-gate CCD is connected in parallel by means of a series of gates to an array of photodiodes. The photodiode provides an electrode free surface region so that a highly efficient waveguide detector coupling technique can be implemented. A thermally-oxidized layer of SiO2 forms an effective substrate for the optical waveguide.

Chen, C. L.↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

Boundary Layer Flow Control with a One Atmosphere Uniform Glow Discharge Surface Plasma

Low speed wind tunnel data have been acquired for planar panels covered by a uniform, glow-discharge surface plasma in atmospheric pressure air known as the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP). Streamwise and spanwise arrays of flush, plasma-generating surface electrodes have been studied in laminar, transitional, and fully turbulent boundary layer flow. Plasma between symmetric streamwise electrode strips caused large increases in panel drag, whereas asymmetric spanwise electrode configurations produced a significant thrust. Smoke wire flow visualization and mean velocity diagnostics show the primary cause of the phenomena to be a combination of mass transport and vortical structures induced by strong paraelectric ElectroHydroDynamic (EHD) body forces on the flow.

J Reece Roth↗

Mars Surveyor Program '01 Mars Environmental Compatibility Assessment wet chemistry lab: a sensor array for chemical analysis of the Martian soil

The Mars Environmental Compatibility Assessment (MECA) instrument was designed, built, and flight qualified for the now canceled MSP (Mars Surveyor Program) '01 Lander. The MECA package consisted of a microscope, electrometer, material patch plates, and a wet chemistry laboratory (WCL). The primary goal of MECA was to analyze the Martian soil (regolith) for possible hazards to future astronauts and to provide a better understanding of Martian regolith geochemistry. The purpose of the WCL was to analyze for a range of soluble ionic chemical species and electrochemical parameters. The heart of the WCL was a sensor array of electrochemically based ion-selective electrodes (ISE). After 20 months storage at -23 degrees C and subsequent extended freeze/thawing cycles, WCL sensors were evaluated to determine both their physical durability and analytical responses. A fractional factorial calibration of the sensors was used to obtain slope, intercept, and all necessary selectivity coefficients simultaneously for selected ISEs. This calibration was used to model five cation and three anion sensors. These data were subsequently used to determine concentrations of several ions in two soil leachate simulants (based on terrestrial seawater and hypothesized Mars brine) and four actual soil samples. The WCL results were compared to simulant and soil samples using ion chromatography and inductively coupled plasma optical emission spectroscopy. The results showed that flight qualification and prolonged low-temperature storage conditions had minimal effects on the sensors. In addition, the analytical optimization method provided quantitative and qualitative data that could be used to accurately identify the chemical composition of the simulants and soils. The WCL has the ability to provide data that can be used to "read" the chemical, geological, and climatic history of Mars, as well as the potential habitability of its regolith.

Non-NASA Center↗

Flexible Microsensor Array for the Monitoring and Control of Plant Growth System

Testing for plant experiments in space has begun to explore active nutrient delivery concepts in which water and nutrients are replenished on a continuous basis for long-term growth. The goal of this study is to develop a novel microsensor array to provide information on the dissolved oxygen environment in the plant root zone for the optimum control of hydroponics and solid substrate plant cultivation systems in the space environment. Miniaturized polarographic dissolved oxygen sensors have been designed and fabricated on a flexible Kapton (trademark) (polyimide) substrate. Two capabilities of the new microsensor array were explored. First, measurements of dissolved oxygen in the plant root zone in hydroponics and solid substrate culture systems were made. The microsensor array was fabricated on a flexible substrate, and then cut out into a mesh type to make a suspended array that could be placed either in a hydroponics system or in a solid substrate cultivation system to measure the oxygen environments. Second, the in situ self-diagnostic and self-calibration capability (two-point for oxygen) was adopted by dynamically controlling the microenvironment in close proximity to the microsensors. With a built-in generating electrode that surrounds the microsensor, two kinds of microenvironments (oxygen-saturated and oxygen-depleted phases) could be established by water electrolysis depending on the polarity of the generating electrode. The unique features of the new microsensor array (small size, multiple sensors, flexibility and self-diagnosis) can have exceptional benefits for the study and optimization of plant cultivation systems in both terrestrial and microgravity environments. The in situ self-diagnostic and self-calibration features of the microsensor array will also enable continuous verification of the operability during entire plant growth cycles. This concept of automated control of a novel chemical monitoring system will minimize crew time required for maintenance, as well as reduce volume, mass, and power consumption by eliminating bulky diagnosis systems including calibrant (fluid and gas) reservoir and flow system hardware.

Kim, Chang-Soo↗

Vacuum microelectronics and miniature instruments based on application specific electrode-integrated nanotube cathodes (ASINCs)

JPL has developed high performance cold cathodes using arrays of carbon nanotube bundles thay routinely produce > 15 A/cm2 at 5 to 8 V/μm applied fields for extreme environment vacuum electronics and miniature instrumentation. These cathodes have been monolithically integrated with additional electrodes using double siliconon-insulator process.

Mojarradi, M.M.↗

Plasma Enhanced Growth of Carbon Nanotubes For Ultrasensitive Biosensors

The multitude of considerations facing nanostructure growth and integration lends itself to combinatorial optimization approaches. Rapid optimization becomes even more important with wafer-scale growth and integration processes. Here we discuss methodology for developing plasma enhanced CVD growth techniques for achieving individual, vertically aligned carbon nanostructures that show excellent properties as ultrasensitive electrodes for nucleic acid detection. We utilize high throughput strategies for optimizing the upstream and downstream processing and integration of carbon nanotube electrodes as functional elements in various device types. An overview of ultrasensitive carbon nanotube based sensor arrays for electrochemical biosensing applications and the high throughput methodology utilized to combine novel electrode technology with conventional MEMS processing will be presented.

Cassell, Alan M.↗

Microchannel detector array for X-rays and UV

Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.

Timothy, J. G.↗

High voltage solar array experiments

The interaction between the components of a high voltage solar array and a simulated space plasma is studied to obtain data for the design of a high voltage solar array capable of 15kW at 2 to 16kV. Testing was conducted in a vacuum chamber 1.5-m long by 1.5-m diameter having a plasma source which simulated the plasma conditions existing in earth orbit between 400 nautical miles and synchronous altitude. Test samples included solar array segments pinholes in insulation covering high voltage electrodes, and plain dielectric samples. Quantitative data are presented in the areas of plasma power losses, plasma and high voltage induced damage, and dielectric properties. Limitations of the investigation are described.

Kennerud, K. L.↗

Si/IrSi3 Schottky-Barrier Infrared Detectors

Si/IrSi or Si/IrSi3 Schottky-barrier detector fabricated by stoichiometric codeposition of Ir and Si on p Si substrate. Includes p+ substrate contact, silicide electrode, and n Si guard ring, which suppresses leakage around periphery of silicide electrode. Part of continuing effort to develop imaging arrays of Schottky-barrier detectors operating at far-infrared wavelengths.

Lin, True-Lon↗