Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Small Particle Response to Fluid Motion using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Before two members of our team found an analytical solution of the equations, numerical methods and/or neglecting terms were required. The general solution predicts that the usually neglected history term becomes important when the characteristic viscous time is in the same order as the vibration period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We also developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the "virtual apparatus". Using state-of-the-art methods in holography we will quantify the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. The motion of particles up to 4 mm in diameter in a fluid that oscillates at frequencies up to 100 Hz with amplitudes up to 200 microns is being examined. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle at the time of recording. The hologram of the particle provides microscopic images of the particle that are used for finding the position with an accuracy of a few microns. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. The electronic holograms can be downlinked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, J. D.↗

Thermal and Mechanical Buckling and Postbuckling Responses of Selected Curved Composite Panels

The results of an experimental and numerical study of the buckling and postbuckling responses of selected unstiffened curved composite panels subjected to mechanical end shortening and a uniform temperature increase are presented. The uniform temperature increase induces thermal stresses in the panel when the axial displacement is constrained. An apparatus for testing curved panels at elevated temperature is described, numerical results generated by using a geometrically nonlinear finite element analysis code are presented. Several analytical modeling refinements that provide more accurate representation of the actual experimental conditions, and the relative contribution of each refinement, are discussed. Experimental results and numerical predictions are presented and compared for three loading conditions including mechanical end shortening alone, heating the panels to 250 F followed by mechanical end shortening, and heating the panels to 400 F. Changes in the coefficients of thermal expansion were observed as temperature was increased above 330 F. The effects of these changes on the experimental results are discussed for temperatures up to 400 F.

Breivik, Nicole L.↗

Multistage Electrophoretic Separators

A multistage electrophoresis apparatus has been invented for use in the separation of cells, protein molecules, and other particles and solutes in concentrated aqueous solutions and suspensions. The design exploits free electrophoresis but overcomes the deficiencies of prior free-electrophoretic separators by incorporating a combination of published advances in mathematical modeling of convection, sedimentation, electro-osmotic flow, and the sedimentation and aggregation of droplets. In comparison with other electrophoretic separators, these apparatuses are easier to use and are better suited to separation in relatively large quantities characterized in the art as preparative (in contradistinction to smaller quantities characterized in the art as analytical). In a multistage electrophoretic separator according to the invention, an applied vertical steady electric field draws the electrically charged particles of interest from within a cuvette to within a collection cavity that has been moved into position of the cuvette. There are multiple collection cavities arranged in a circle; each is aligned with the cuvette for a prescribed short time. The multistage, short-migration-path character of the invention solves, possibly for the first time, the fluid-instability problems associated with free electrophoresis. The figure shows a prototype multistage electrophoretic separator that includes four sample stations and five collection stages per sample. At each sample station, an aqueous solution or suspension containing charged species to be separated is loaded into a cuvette, which is machined into a top plate. The apparatus includes a lower plate, into which 20 collection cavities have been milled. Each cavity is filled with an electrophoresis buffer solution. For the collection of an electrophoretic fraction, the lower plate is rotated to move a designated collection cavity into alignment with the opening of the cuvette. An electric field is then applied between a non-gassing electrode in the collection cavity and an electrolyte compartment, which is separated from the cuvette by a semipermeable membrane. The electrolyte is refreshed by circulation by use of a peristaltic pump. In subsequent steps, the lower plate is rotated to collect other electrophoretic fractions. Later, the collected fractions are removed from the collection cavities through ports that have threaded plugs. The base of the apparatus contains power supplies and a computer interface. The design includes provisions for monitoring and feedback control of cavity position, electric field, and temperature. The operation of the apparatus can easily be automated, as demonstrated by use of software that has already been written for this purpose.

Thomas, Nathan↗

Atomic Mixing of Initially Separated Mixtures

We consider the atomic mixing of two materials, initially separated in space, at fixed temperature– pressure conditions [T, p], and zero mass-mean velocity. Each material is composed of a specified set of atomic species whose density corresponds to the specieswise real Equation of State (EOS) $\tilde{&#961}$ i [T, p]. Because there are no spatial gradients in the mean [T, p] state, the only mechanism for mixing is a specieswise nonequilibrium thermal velocity distribution. The recipe for nonequilibrium species mass fluxes is taken directly from Hirschfelder, Curtiss, and Bird, who express the diffusion velocities in terms of gradients in the molar concentrations and pairwise coefficients of diffusion. EOS data from the SESAME library is used for all species. Data for the specieswise self diffusion coefficients is adopted from the Orbital Free Molecular Dynamics (OFMD) simulations of Ticknor et al.; the so-called Darken approximation is used to express the mutual diffusion coefficients of a mixture in the manner used by White et al. A one-dimensional spatial domain is used; with the left half occupied by one multispecies material and the right half occupied by the other, and with zero–gradient boundary conditions at the ends of the domain. Hence the total mass in the domain is a constant. At time t = 0 the materials are separated. Accordingly, spatial gradients at the separation point are infinite and the species fluxes are also infinite. As t → $\textbf{∞}$ the spatial gradients approach zero and a uniform set of species concentrations is obtained; at this point the system is said to be at “thermodynamic equilibrium.” Analytic solution of the problem is not possible in general due to the nonlinear concentration dependence of the species fluxes. Hence we utilize the numerical solution apparatus in Mathematica for obtaining accurate time-dependent solutions for the mixing of various initial species masses for conditions of interest in laser-driven Inertial Confinement Fusion. Concentration profiles and the speed of propagation of the mixing fronts are discussed in light of the nonlinearity of the problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excitation of positive ions by low-energy electrons - Relevance to the Io Torus

The importance of measuring electron-ion excitation cross sections in singly and multiply charged positive ions is outlined, and recent results for Mg II and O II ions are given using the JPL's electron energy-loss merged-beams apparatus. Theoretical comparisons are given with two five-state close-coupling calculations. The energy variation of the collision strength is fitted with a semiempirical analytic function which includes approximations to polarization, resonance, and exchange contributions. In O II, first spectra anywhere of electron excitation of the optically allowed transitions are presented. In addition, excitations of two low lying, optically forbidden transitions are detected for the first time.

Smith, Steven J.↗

Community Extreme Tonnage User Service (CETUS): A 5000 Ton Open Research Facility in the United States

Large sample volume 5000 ton multi-anvil presses have contributed to the exploration of deep Earth and planetary interiors, synthesis of ultra-hard and other novel materials, and serve as a sample complement to pressure and temperature regimes already attainable by diamond anvil cell experiments. However, no such facility exists on the North American continent. We propose the establishment of an open user facility for COMPRES members and the entire research community, with the unique capability of a 5000 ton (or more) press, supported by a host of extant co-located experimental and analytical laboratories and research staff. We offer wide range of complementary and/or preparatory experimental options. Any required synthesis of materials or follow up experiments can be carried out controlled atmosphere furnaces, piston cylinders, multi-anvil, or experimental impact apparatus. Additionally, our division houses two machine shops that would facilitate any modification or custom work necessary for development of CETUS, one for general fabrication and one located specifically within our experimental facilities. We also have a general sample preparation laboratory, specifically for experimental samples, that allows users to quickly and easily prepare samples for ebeam analyses and more. A service we can offer to COMPRES community members in general, and CETUS visiting users specifically, is a multitude of analytical instrumentation literally steps away from the experimental laboratories. This year we will be pursuing site funding of our laboratories through NASA's Planetary Science Directorate, which should result in substantial cost savings to all visiting users, and supports our mission of interagency cooperation for the enhancement of science for all (see companion PSAMS abstract). The PI is in a unique position as an employee of Jacobs Technology to draw funding from multiple sources, including those from industry and commerce. We submitted a Planetary Major Equipment proposal to the NASA Emerging Worlds solicitation for the full cost of a press, with competitive bids submitted from Sumitomo, Rockland Research, and Voggenreiter. Additional funding is currently being sought from industry sources through the Strategic Partnerships Office at NASA JSC, External Pursuits Program Office on the JETS contract, and Jacobs corporate in the United States. Internal funding is available for JETS contract personnel to travel to large press locations worldwide to study set-up and operations. We also anticipate a fortuitous cost savings in installation of the large press because plans are already underway for major renovations to the entire experimental petrology suite within the next 2 years in order to accommodate our growing user base. Our focus as contract staff is on serving the scientific needs of our users and collaborators. We are seeking community expert input on multiple aspects of this proposed facility, such as the press type and design, access management, immediate projects, and future innovation initiatives.

Danielson, L.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Design and performance of high-temperature furnace and cell holder for in situ spectroscopic, electrochemical, and radiolytic investigations of molten salts

To facilitate the development of molten salt reactor technologies, a fundamental understanding of the physical and chemical properties of molten salts under the combined conditions of high temperature and intense radiation fields is necessary. Optical spectroscopic (UV–Vis–near IR) and electrochemical techniques are powerful analytical tools to probe molecular structure, speciation, thermodynamics, and kinetics of solution dynamics. In this paper, we report the design and fabrication of three custom-made apparatus: (i) a multi-port spectroelectrochemical furnace equipped with optical spectroscopic and electrochemical instrumentation, (ii) a high-temperature cell holder for time-resolved optical detection of radiolytic transients in molten salts, and (iii) a miniaturized spectroscopy furnace for the investigation of steady-state electron beam effects on molten salt speciation and composition by optical spectroscopy. Initial results obtained with the spectroelectrochemical furnace (i) and high-temperature cell holder (ii) are reported.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effective thermal conductivity of fully and partially saturated metal wicks

The purpose of the study is threefold: (1) to perform accurate experiments covering a wide range of porosities to determine the effective thermal conductivity of sintered fiber porous metals fully saturated with air, water, and water vapor; (2) to propose correlations for these cases, and to compare these correlations with existing analytical predictions, experimental correlations and data; and (3) to determine the effective thermal conductivity of porous metals partially saturated with water and water vapor, respectively. The experimental apparatus, based on the steady-state method of comparison, is designed and used for determining the effective thermal conductivity. The wicks are made of nickel 200, stainless steel 430, and copper, covering a porosity range 0.30-0.67. Based on the experimental results, a single correlation is derived for predicting the effective thermal conductivity of all wicks fully saturated with air, water, and water vapor. For two partially saturated wick specimens with both high porosity and large matrix thermal conductivity, a liquid-vapor transition zone is observed between the phases, which increases the total combined effective thermal conductivity of the specimen.

Kar, K.↗

Design and Preparation of a Particle Dynamics Space Flight Experiment, SHIVA

ABSTRACT This paper describes the flight experiment, supporting ground science, and the design rationale for project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA is a fundamental study of particle dynamics in fluids in microgravity. Gravity often dominates the equations of motion of a particle in a fluid, so microgravity provides an ideal environment to study the other forces, such as the pressure and viscous drag and especially the Basset history force. We have developed diagnostic recording methods using holography to save all of the particle field optical characteristics, essentially allowing the experiment to be transferred from space back to earth in what we call the "virtual apparatus" for on-earth microgravity experimentation. We can quantify precisely the three-dimensional motion of sets of particles, allowing us to test and apply new analytical solutions developed by members of the team as reported in the 2001 Conference (Banff, Canada). In addition to employing microgravity to augment the fundamental study of these forces, the resulting data will allow us to quantify and understand the ISS environment with great accuracy. This paper shows how we used both experiment and theory to identify and resolve critical issues and produce an optimal the study. We examined the response of particles of specific gravity from 0.1 to 20, with radii from 0.2 to 2mm. to fluid oscillation at frequencies up to 80 Hz with amplitudes up to 200 microns. To observe some of the interesting effects predicted by the new solutions requires the precise location of the position of a particle in three dimensions. To this end we have developed digital holography algorithms that enable particle position location to a small fraction of a pixel in a CCD array. The spaceflight system will record holograms both on film and electronically. The electronic holograms can be downlinked providing real time data, essentially acting like a remote window into the ISS experimental chamber. Ground experiments have provided input to a flight system design that can meet the requirements for a successful experiment on ISS. Moreover the ground experiments have provided a definitive, quantitative observation of the Basset History force over a wide range of conditions. Results of the ground experiments, the flight experiment design, preliminary flight hardware design, and data analysis procedures are reported.

Trolinger, James↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.

Shelley, Jacob T.↗

Small Particle Response to Fluid Motion Using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Through an innovative application of fractional differential equations, two members of our team produced the first analytical solution of a fundamental equation of motion, which had only been solved numerically or by approximation before. The general solution predicts that the usually neglected history term becomes important in particle response to a sinusoidal fluid movement when the characteristic viscous time is in the same order as the fluid oscillation period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We have developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the virtual apparatus for on-earth microgravity experimentation. We can quantify precisely the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. We are examining the response of particles up to 2 mm radius to fluid oscillation at frequencies up to 80 Hz with amplitudes up to 200 microns. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle to within microns during recording, and techniques for achieving this are one of the project challenges. Focused microscopic images and diffraction patterns are used. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. A cross correlation procedure enables sub pixel accuracies for electronic recordings, partially accommodating the lower spatial resolution of CCDs. The electronic holograms can be down linked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, James↗

Computer implemented empirical mode decomposition method, apparatus and article of manufacture

A computer implemented physical signal analysis method is invented. This method includes two essential steps and the associated presentation techniques of the results. All the steps exist only in a computer: there are no analytic expressions resulting from the method. The first step is a computer implemented Empirical Mode Decomposition to extract a collection of Intrinsic Mode Functions (IMF) from nonlinear, nonstationary physical signals. The decomposition is based on the direct extraction of the energy associated with various intrinsic time scales in the physical signal. Expressed in the IMF's, they have well-behaved Hilbert Transforms from which instantaneous frequencies can be calculated. The second step is the Hilbert Transform. The final result is the Hilbert Spectrum. Thus, the invention can localize any event on the time as well as the frequency axis. The decomposition can also be viewed as an expansion of the data in terms of the IMF's. Then, these IMF's, based on and derived from the data, can serve as the basis of that expansion. The local energy and the instantaneous frequency derived from the IMF's through the Hilbert transform give a full energy-frequency-time distribution of the data which is designated as the Hilbert Spectrum.

Huang, Norden E.↗

Computer implemented empirical mode decomposition method apparatus, and article of manufacture utilizing curvature extrema

A computer implemented physical signal analysis method is includes two essential steps and the associated presentation techniques of the results. All the steps exist only in a computer: there are no analytic expressions resulting from the method. The first step is a computer implemented Empirical Mode Decomposition to extract a collection of Intrinsic Mode Functions (IMF) from nonlinear, nonstationary physical signals based on local extrema and curvature extrema. The decomposition is based on the direct extraction of the energy associated with various intrinsic time scales in the physical signal. Expressed in the IMF's, they have well-behaved Hilbert Transforms from which instantaneous frequencies can be calculated. The second step is the Hilbert Transform. The final result is the Hilbert Spectrum. Thus, the invention can localize any event on the time as well as the frequency axis. The decomposition can also be viewed as an expansion of the data in terms of the IMF's. Then, these IMF's, based on and derived from the data, can serve as the basis of that expansion. The local energy and the instantaneous frequency derived from the IMF's through the Hilbert transform give a full energy-frequency-time distribution of the data which is designated as the Hilbert Spectrum.

Huang, Norden Eh↗

Method and apparatus for spur-reduced digital sinusoid synthesis

A technique for reducing the spurious signal content in digital sinusoid synthesis is presented. Spur reduction is accomplished through dithering both amplitude and phase values prior to word-length reduction. The analytical approach developed for analog quantization is used to produce new bounds on spur performance in these dithered systems. Amplitude dithering allows output word-length reduction without introducing additional spurs. Effects of periodic dither similar to that produced by a pseudo-noise (PN) generator are analyzed. This phase dithering method provides a spur reduction of 6(M + 1) dB per phase bit when the dither consists of M uniform variates. While the spur reduction is at the expense of an increase in system noise, the noise power can be made white, making the power spectral density small. This technique permits the use of a smaller number of phase bits addressing sinusoid look-up tables, resulting in an exponential decrease in system complexity. Amplitude dithering allows the use of less complicated multipliers and narrower data paths in purely digital applications, as well as the use of coarse-resolution, highly-linear digital-to-analog converters (DAC's) to obtain spur performance limited by the DAC linearity rather than its resolution.

Zimmerman, George A.↗