Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Ambient Conditions on Helicopter Harmonic Noise Radiation: Theory and Experiment

The effects of ambient atmospheric conditions, air temperature, and density on rotor harmonic noise radiation are characterized using theoretical models and experimental measurements of helicopter noise collected at three different test sites at elevations ranging from sea level to 7000 ft above sea level. Significant changes in the thickness, loading, and blade–vortex interaction noise levels and radiation directions are observed across the different test sites for an AS350 helicopter flying at the same indicated airspeed and gross weight. However, the radiated noise is shown to scale with ambient pressure when the flight condition of the helicopter is defined in nondimensional terms. Although the effective tip Mach number is identified as the primary governing parameter for thickness noise, the nondimensional weight coefficient also impacts lower harmonic loading noise levels, which contribute strongly to low-frequency harmonic noise radiation both in and out of the plane of the horizon. Strategies for maintaining the same nondimensional rotor operating condition under different ambient conditions are developed using an analytical model of single main rotor helicopter trim and confirmed using a CAMRAD II model of the AS350 helicopter. The ability of the Fundamental Rotorcraft Acoustics Modeling from Experiments (FRAME) technique to generalize noise measurements made under one set of ambient conditions to make accurate noise predictions under other ambient conditions is also validated.

rotorcraft↗

The Effects of Ambient Conditions on Helicopter Harmonic Noise Radiation: Theory and Experiment

The effects of ambient atmospheric conditions, air temperature and density, on rotor harmonic noise radiation are characterized using theoretical models and experimental measurements of helicopter noise collected at three different test sites at elevations ranging from sea level to 7000 ft above sea level. Significant changes in the thickness, loading, and blade-vortex interaction noise levels and radiation directions are observed across the different test sites for an AS350 helicopter flying at the same indicated airspeed and gross weight. However, the radiated noise is shown to scale with ambient pressure when the flight condition of the helicopter is defined in nondimensional terms. Although the effective tip Mach number is identified as the primary governing parameter for thickness noise, the nondimensional weight coefficient also impacts lower harmonic loading noise levels, which contribute strongly to low frequency harmonic noise radiation both in and out of the plane of the horizon. Strategies for maintaining the same nondimensional rotor operating condition under different ambient conditions are developed using an analytical model of single main rotor helicopter trim and confirmed using a CAMRAD II model of the AS350 helicopter. The ability of the Fundamental Rotorcraft Acoustics Modeling from Experiments (FRAME) technique to generalize noise measurements made under one set of ambient conditions to make accurate noise predictions under other ambient conditions is also validated.

Greenwood, Eric↗

Spray and combustion characteristics of butanol-diesel and hexanol-diesel blends under high-altitude conditions

Due to their excellent fuel properties, butanol and hexanol are considered as two promising renewable fuels for diesel engine applications. The objective of this work is to investigate and compare the spray and combustion characteristics of butanol-diesel and hexanol-diesel blends under high-altitude conditions. A constant volume combustion chamber was used to provide the desired environment. Experiments were conducted under various ambient temperatures ranging from 800 K to 1200 K and various ambient densities ranging from 11 kg/m3 to 15 kg/m3. Fuel blends with 20% blend ratio (B20 and H20) and neat diesel were used as test fuels. The spray and combustion characteristics of the test fuels were analyzed using measured liquid penetration length, ignition delay, combustion duration, flame lift-off length (FLoL), and spatially integrated natural luminosity (SINL). Here the results revealed that B20 and H20 had shorter liquid penetration length than diesel under low ambient temperature and density conditions due to their higher volatility. The blended fuels showed significantly longer ignition delay than diesel under low ambient temperature conditions, but it could be overcome by increasing the ambient temperature. Adding butanol and hexanol into diesel both extended FLoL especially under low ambient temperature and density conditions, but the effects of hexanol was less dramatic compared to butanol due to its lower latent heat of vaporization and higher chemical reactivity. Both B20 and H20 showed lower SINL than diesel under any conditions, indicating their ability of reducing soot emissions. However, no apparent differences could be found between these two fuels until the ambient temperature dropped to 800 K.

42 ENGINEERING↗

Icing and De-Icing of a Propeller with Internal Electric Blade Heaters

An investigation has been made in the NACA Cleveland icing research tunnel to determine the de-icing effectiveness of an experimental configuration of an Internal electric propeller-blade heater. Two atmospheric Icing conditions and two propeller operating conditions were Investigated, In experiments with unheated blades and with heat applied to the blades both continuously and cyclically. Data are presented to show the effect of propeller speed., ambient air temperature and liquid-water concentration, and the duration of the heat-on and cycle times on the power requirements and de-Icing performance of the blade heaters. The extent of ice-covered area on the blades for various icing ax4 operating conditions has been determined. The largest iced area was obtained at the higher ambient-air temperatures and at low propeller speed. The ohord.wise extent of Icing In practically every case was greater than that covered by blade heaters. Adequate de-icing in the heated area with continuous application of heat was obtained with the power available but a maximum power, input of 1250 watts per blade was insufficient for cyclic de-Icing for the range of conditions investigated. Blade-surface temperature rates of rise of 0.2 to 0.7 F per second were obtained and the minimum cooling period for cyclic de-icing was found to be approximately 2-1/2 times the heating period.

Lewis, James P.↗

Geology and distribution of impact craters on Venus - What are they telling us?

Data on the distribution of impact craters on Venus are analyzed in relation to the geologic history of Venus and the effects of high ambient pressures and temperatures on the cratering process itself. The cratering record of Venus is discussed in terms of size, number, spatial distribution, and state of preservation of craters. The morphology of Venusian craters is examined as a function of the diameter, and features unique to these craters are discussed. Attention is also given to several craters that illustrate important features of Venusian crater; surface 'splotches' that are closely related in origin to impact craters; and implications of the distribution of severely modified craters for Venus' recent geologic history.

Schaber, G. G.↗

Cosmology with liquid mirror telescopes

Liquid mirrors provide an exciting means to obtain large optical telescopes for substantially lower costs than conventional technologies. The liquid mirror concept has been demonstrated in the lab with the construction of a diffraction limited 1.5 m mirror. The mirror surface, using liquid mercury, forms a perfect parabolic shape when the mirror cell is rotated at a uniform velocity. A liquid mirror must be able to support a heavy mercury load with minimal flexure and have a fundamental resonant frequency that is as high as possible, to suppress the amplitude of surface waves caused by small vibrations transmitted to the mirror. To minimize the transmission of vibrations to the liquid surface, the entire mirror rests on an air bearing. This necessitates the mirror cell being lightweight, due to the limited load capabilities of the air bearing. The mirror components must also have physical characteristics which minimize the effects of thermal expansion with ambient temperature fluctuations in the observatory. In addition, the 2.7 m mirror construction is designed so that the techniques used may be readily extended to the construction of large mirrors. To attain the goals of a lightweight, rigid mirror, a composite laminant construction was used. The mirror consists of a foam core cut to the desired parabolic shape, with an accuracy of a few mm. An aluminum hub serves as an anchor for the foam and skin, and allows precise centering of the mirror on the air bearing and drive system. Several plys of Kevlar, covered in an epoxy matrix, are then applied to the foam. A final layer of pure epoxy is formed by spin casting. This final layer is parabolic to within a fraction of a mm. An aluminum ring bonded to the circumference of the mirror retains the mercury, and incorporates stainless-steel hard-points for the attachment of balance weights.

Hogg, David W.↗

Fatigue Crack Growth Rate Test Results for Al-Li 2195 Parent Metal, Variable Polarity Plasma Arc Welds and Friction Stir Welds

The fatigue crack growth rate of aluminum-lithium (Al-Li) alloy 2195 plate and weldments was determined at 200-F, ambient temperature and -320-F. The effects of stress ratio (R), welding process, orientation and thickness were studied. Results are compared with plate data from the Space Shuttle Super Lightweight Tank (SLWT) allowables program. Data from the current series of tests, both plate and weldment, falls within the range of data generated during the SLWT allowables program.

Hafley, Robert A.↗

SiC Fiber-Reinforced Celsian Composites

Celsian is a promising matrix material for fiber-reinforced composites for high temperature structural applications. Processing and fabrication of small diameter multifilament silicon carbide tow reinforced celsian matrix composites are described. Mechanical and microstructural properties of these composites at ambient and elevated temperatures are presented. Effects of high-temperature exposures in air on the mechanical behavior of these composites are also given. The composites show mechanical integrity up to ~1100 C but degrade at higher temperatures in oxidizing atmospheres. A model has been proposed for the degradation of these composites in oxidizing atmospheres at high temperatures.

Bansal, Narottam P.↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗

Abundance of spring‐ and winter‐active arthropods declines with warming

Abstract Because ectotherm activity and metabolism are sensitive to temperature, terrestrial arthropods may be especially responsive to ongoing climatic warming. Here, we quantified responses of arthropod abundance to two years of warming in an outdoor temperature manipulation experiment at Duke Forest, North Carolina, USA. Nine open‐top chambers were individually heated year‐round from 1.5° to 5.5°C above ambient temperature. From two years of monthly pitfall trapping, we collected and identified 4,468 arthropods representing 24 orders. We initially predicted that arthropods would experience the greatest negative effects of experimental warming during the summer months, when temperatures reach their yearly maximum and arthropods may be close to their maximum thermal tolerance limits. Instead, we found that the strongest negative effects on arthropod abundance occurred during the winter and spring, when ambient temperatures are relatively cooler, whereas the effects of experimental warming on abundance were not significant during the summer or fall. During the spring of 2012, the warmest spring on record for the southeastern USA, total arthropod abundance declined 20% per °C of experimental warming. Abundance declines were driven largely by flies (Diptera), which were the most abundant insect order, representing approximately a third of all arthropods collected. The most abundant arthropod family, Mycetophilidae (fungus gnats), declined 64% per °C of warming during the spring of 2012. Although previous research on climatic warming has focused on the impact of maximum yearly temperatures on organismal performance, our results are more consistent with the cool‐season sensitivity hypothesis, which posits that arthropods adapted for cooler conditions are likely to face the strongest negative effects of warming during the cooler seasons.

54 ENVIRONMENTAL SCIENCES↗

Cryogenic Insulation Standard Data and Methodologies Project

Extending some recent developments in the area of technical consensus standards for cryogenic thermal insulation systems, a preliminary Inter-Laboratory Study of foam insulation materials was performed by NASA Kennedy Space Center and LeTourneau University. The initial focus was ambient pressure cryogenic boil off testing using the Cryostat-400 flat-plate instrument. Completion of a test facility at LETU has enabled direct, comparative testing, using identical cryostat instruments and methods, and the production of standard thermal data sets for a number of materials under sub-ambient conditions. The two sets of measurements were analyzed and indicate there is reasonable agreement between the two laboratories. Based on cryogenic boiloff calorimetry, new equipment and methods for testing thermal insulation systems have been successfully developed. These boiloff instruments (or cryostats) include both flat plate and cylindrical models and are applicable to a wide range of different materials under a wide range of test conditions. Test measurements are generally made at large temperature difference (boundary temperatures of 293 K and 78 K are typical) and include the full vacuum pressure range. Results are generally reported in effective thermal conductivity (ke) and mean heat flux (q) through the insulation system. The new cryostat instruments provide an effective and reliable way to characterize the thermal performance of materials under subambient conditions. Proven in through thousands of tests of hundreds of material systems, they have supported a wide range of aerospace, industry, and research projects. Boiloff testing technology is not just for cryogenic testing but is a cost effective, field-representative methodology to test any material or system for applications at sub-ambient temperatures. This technology, when adequately coupled with a technical standards basis, can provide a cost-effective, field-representative methodology to test any material or system for applications at sub-ambient to cryogenic temperatures. A growing need for energy efficiency and cryogenic applications is creating a worldwide demand for improved thermal insulation systems for low temperatures. The need for thermal characterization of these systems and materials raises a corresponding need for insulation test standards and thermal data targeted for cryogenic-vacuum applications. Such standards have a strong correlation to energy, transportation, and environment and the advancement of new materials technologies in these areas. In conjunction with this project, two new standards on cryogenic insulation were recently published by ASTM International: C1774 and C740. Following the requirements of NPR 7120.10, Technical Standards for NASA Programs and Projects, the appropriate information in this report can be provided to the NASA Chief Engineer as input for NASA's annual report to NIST, as required by OMB Circular No. A-119, describing NASA's use of voluntary consensus standards and participation in the development of voluntary consensus standards and bodies.

Technology Portfolio System↗

Soil Temperature Sensor Data, 2025, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville, Tennessee: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset includes 16 CSV files documenting soil temperature measurements recorded by HOBO Pendant MX Water Temperature Data Loggers. Data collection for all sites began on January 1, 2025. The end time for each sensor is provided in the End Time_2025.csv file. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Radiation effects on selected electronics parts from the solar max satellite

The Solar Maximum Satellite was launched on February 14, 1980. Problems with the Main Electronics Box (MEB) were experienced in the period July 10 to September 30, 1980. Failure occurred in the October to November time frame. Replacement of the Main Electronic Box (MEB) was performed in April 1984. The failed original MEB was returned to Earth and offered an opportunity to study some electronic parts which had spent 50 months in the natural radiation environment of a low Earth orbit (LEO) spacecraft. Spare parts were annealed at ambient temperatures on the ground. Dose rate effects between the flight and laboratory environments were compared.

R H Maurer↗

Effects of Warming and Elevated CO2 on Stomatal Conductance and Chlorophyll Fluorescence of C3 and C4 Coastal Wetland Species

Abstract Coastal wetland communities provide valuable ecosystem services such as erosion prevention, soil accretion, and essential habitat for coastal wildlife, but are some of the most vulnerable to the threats of climate change. This work investigates the combined effects of two climate stressors, elevated temperature (ambient, + 1.7 °C, + 3.4 °C, and 5.1 °C) and elevated CO 2 ( e CO 2 ), on leaf physiological traits of dominant salt marsh plant species. The research took place at the Salt Marsh Accretion Response to Temperature eXperiment (SMARTX) at the Smithsonian Environmental Research Center, which includes two plant communities: a C 3 sedge community and a C 4 grass community. Here we present data collected over five years on rates of stomatal conductance (g s ), quantum efficiency of PSII photochemistry ( F v / F m ), and rates of electron transport (ETR max ). We found that both warming and e CO 2 caused declines in all traits, but the warming effects were greater for the C 3 sedge. This species showed a strong negative stomatal response to warming in 2017 and 2018 (28% and 17% reduction, respectively in + 5.1 °C). However, in later years the negative response to warming was dampened to < 7%, indicating that S. americanus was able to partially acclimate to the warming over time. In 2022, we found that sedges growing in the combined + 5.1 °C e CO 2 plots exhibited more significant declines in g s , F v /F m , and ETR max than in either treatment individually. These results are important for predicting future trends in growth of wetland species, which serve as a large carbon sink that may help mitigate the effects of climate change.

54 ENVIRONMENTAL SCIENCES↗

Effects of microgravity on urinary osteopontin

Increased risk of renal stone formation during space flight has been linked primarily to increased calcium excretion from bone demineralization induced by space flight. Other factors contributing to increased risk include increased urinary calcium oxalate supersaturation, while urinary citrate, magnesium and volume are all decreased. The aim of this study was to increase the predictive value of stone risk profiles for crew members during space flight by evaluating the excretion of urinary protein inhibitors of calcium crystallization so that more comprehensive stone risk profiles could relate mineral saturation to the concentrations of inhibitor proteins. Levels of urinary osteopontin (uropontin) are reported in a series of 14 astronauts studied before, during, and after space flights. During space flight, a compensatory increase in uropontin excretion was not observed. However, the uropontin excretion of a majority of astronauts was increased during the period after space flight and was maximal at 2 wk after landing. The downward shift in the molecular size of uropontin observed in samples obtained during space flight was shown to result from storage at ambient temperature during flight, rather than an effect of microgravity on uropontin synthesis.

NASA Experiment Number 9401651↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This, in turn, is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study, we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in enhanced geothermal system binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data, we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost. These results make a case for the inclusion of location-based weather data as inputs to supply curves that are used in capacity expansion models for the prediction of future geothermal deployment scenarios.

ambient temperature↗