Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

fluxfinder: An R Package for Reproducible Calculation and Initial Processing of Greenhouse Gas Fluxes From Static Chamber Measurements

Fluxes of greenhouse gases are a critical component of the earth's natural climate, but anthropogenic emissions have created an imbalance and resulted in global climate change. Quantifying the emission of these gases is vital to our understanding of their sources and sinks, both natural and anthropogenic. The static chamber method, in which a system of interest is enclosed, and gas concentrations are measured over time, is widely used to estimate fluxes of greenhouse gases. With the development of instruments such as infrared gas analyzers (IRGAs) supporting high-frequency concentration data, there is a growing need for open-source workflows to calculate fluxes. Here we present fluxfinder, an R package designed to support reproducible calculations and processing of greenhouse gas fluxes measured with the static chamber method. The package includes raw data file parsing from widely used IRGAs, metadata matching, unit conversion, flux estimations, and initial quality assurance/quality control (QA/QC). Diagnostic graphical plots provide a transparent way to differentiate between measurement issues and nonlinear behavior. The package is also designed to be easily integrated with the gasfluxes package for further fitting of nonlinear concentration-time models, allowing alternative or additional flux QA/QC. The fluxfinder package offers a flexible workflow that is easily adaptable to promote open and reproducible greenhouse gas flux estimations.

Wilson, Stephanie J.↗

Active learning path-dependent properties using a cloud-based materials acceleration platform

Solid state materials are central to many modern technologies in which a given material may be exposed to a variety of environments. The material properties often vary with the sequence of environments in an irreversible manner, resulting in a quintessential path-dependency in experimental observables. While sequential learning techniques have been effectively deployed for accelerating learning of state properties of materials, they often use a consistent environment path in all experiments. To elevate such techniques for making optimal decisions in experimental investigations of path-dependent properties, we introduce an iterated expected information gain acquisition function that optimizes over entire experimental trajectories. This approach is implemented within a cloud-based Materials Acceleration Platform architecture utilizing an event-driven stateful broker coupled with remote HELAO (Hierarchical Experimental Laboratory Automation and Orchestration) instances and an AI science manager. The platform's efficacy was demonstrated through a case study optimizing multi-step spectro-electrochemical experiments to identify optically stable potential windows in (Co–Ni–Sb)O z metal oxides. The system successfully integrated AI-driven experiment design, remote laboratory automation, and cloud-based data infrastructure, validating the platform's capability for managing complex, adaptive, path-dependent workflows in materials discovery.

Guevarra, Dan [California Institute of Technology ↗

G4VG

G4VG reads the in-memory Geant4 geometry (the volume hierarchy and physical shape descriptions defined by a user application) and produces an equivalent VecGeom representation. This provides a direct bridge between Geant4 detector descriptions and VecGeom-based applications, eliminating the need for manual export pipelines or specialized GDML workflows. The code is adapted from the Celeritas project and developed as an independent utility for broader reuse.

Johnson, SethR [Oak Ridge National Laboratory] (00↗

SmoQyDQMC.jl: A flexible implementation of determinant quantum Monte Carlo for Hubbard and electron-phonon interactions

We introduce the SmoQyDQMC.jl package, a Julia implementation of the determinant quantum Monte Carlo algorithm. SmoQyDQMC.jl supports generalized tight-binding Hamiltonians with on-site Hubbard and generalized electron-phonon ( e e -ph) interactions, including non-linear e e -ph coupling and anharmonic lattice potentials. Our implementation uses hybrid Monte Carlo methods with exact forces for sampling the phonon fields, enabling efficient simulation of low-energy phonon branches, including acoustic phonons. The SmoQyDQMC.jl package also uses a flexible scripting interface, allowing users to adapt it to different workflows and interface with other software packages in the Julia ecosystem. The code for this package can be downloaded from our GitHub repository at https://github.com/SmoQySuite/SmoQyDQMC.jl or installed using the Julia package manager. The online documentation, including examples, can be obtained from our document page at https://smoqysuite.github.io/SmoQyDQMC.jl/stable/.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Codebase release r0.3 for SmoQyDQMC.jl

We introduce the SmoQyDQMC.jl package, a Julia implementation of the determinant quantum Monte Carlo algorithm. SmoQyDQMC.jl supports generalized tight-binding Hamiltonians with on-site Hubbard and generalized electron-phonon ( e e -ph) interactions, including non-linear e e -ph coupling and anharmonic lattice potentials. Our implementation uses hybrid Monte Carlo methods with exact forces for sampling the phonon fields, enabling efficient simulation of low-energy phonon branches, including acoustic phonons. The SmoQyDQMC.jl package also uses a flexible scripting interface, allowing users to adapt it to different workflows and interface with other software packages in the Julia ecosystem. The code for this package can be downloaded from our GitHub repository at https://github.com/SmoQySuite/SmoQyDQMC.jl or installed using the Julia package manager. The online documentation, including examples, can be obtained from our document page at https://smoqysuite.github.io/SmoQyDQMC.jl/stable/.

Cohen-Stead, Benjamin (ORCID:0000000279156280)↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

SU-E-J-127: Implementation of An Online Replanning Tool for VMAT Using Flattening Filter-Free Beams

Purpose: This is to report the implementation of an online replanning tool based on segment aperture morphing (SAM) for VMAT with flattening filter free (FFF) beams. Methods: Previously reported SAM algorithm modified to accommodate VMAT with FFF beams was implemented in a tool that was interfaced with a treatment planning system (Monaco, Elekta). The tool allows (1) to output the beam parameters of the original VMAT plan from Monaco, and (2) to input the apertures generated from the SAM algorithm into Monaco for the dose calculation on daily CT/CBCT/MRI in the following steps:(1) Quickly generating target contour based on the image of the day, using an auto-segmentation tool (ADMIRE, Elekta) with manual editing if necessary; (2) Morphing apertures based on the SAM in the original VMAT plan to account for the interfractional change of the target from the planning to the daily images; (3) Calculating dose distribution for new apertures with the same numbers of MU as in the original plan; (4) Transferring the new plan into a record & verify system (MOSAIQ, Elekta); (5) Performing a pre-delivery QA based on software; (6) Delivering the adaptive plan for the fraction.This workflow was implemented on a 16-CPU (2.6 GHz dual-core) hardware with GPU and was tested for sample cases of prostate, pancreas and lung tumors. Results: The online replanning process can be completed within 10 minutes. The adaptive plans generally have improved the plan quality when compared to the IGRT repositioning plans. The adaptive plans with FFF beams have better normal tissue sparing as compared with those of FF beams. Conclusion: The online replanning tool based on SAM can quickly generate adaptive VMAT plans using FFF beams with improved plan quality than those from the IGRT repositioning plans based on daily CT/CBCT/MRI and can be used clinically. This research was supported by Elekta Inc. (Crawley, UK)

60 APPLIED LIFE SCIENCES↗

A New Integrated Analysis Suite for Fast-Ion Study in KSTAR

Here, an integrated workflow for fast-ion analysis was developed by adapting the One Modeling Framework for Integrated Task (OMFIT) workflow manager to support a standard and unified analysis platform for KSTAR users. The newly established analysis suite offers a graphical user interface–based workflow to enable users to readily access and handle experimental data archived in various data formats and servers. Further, users can analyze the data by importing modules designed for conducting certain tasks, such as profile fitting, equilibrium reconstruction, and postprocessing of tokamak data. The procedures for preparing the inputs for fast-ion simulations are streamlined by a common workflow manager, which enables the parallel processing of various tasks to efficiently analyze large fast-ion datasets. The OMFIT platform comprises a flexible Python-based application that enables users to freely manipulate the Python scripts for applications that are unavailable in the standard workflow. The framework also offers mapping tools to translate the output data into the Integrated Modeling and Analysis Suite format to maintain application compatibility for future ITER burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARS: Malleable Actor-Critic Reinforcement Learning Scheduler

In this paper, we introduce MARS, a new scheduling system for HPC-cloud infrastructures based on a cost-aware, flexible reinforcement learning approach, which serves as an intermediate layer for next generation HPC-cloud resource manager. MARS ensembles the pre-trained models from heuristic workloads and decides on the most cost-effective strategy for optimization. A whole workflow application would be split into several optimizable dependent sub-tasks, then based on the pre- defined resource management plan, a reward will be generated after executing a scheduled task. Lastly, MARS updates the Deep Neural Network (DNN) model based on the reward. MARS is designed to optimize the existing models through reinforcement mechanisms. MARS adapts to the dynamics of workflow applications, selects the most cost-effective scheduling solution among pre-built scheduling strategies (backfilling, SJF, etc.) and self- learning deep neural network model at run-time. We evaluate MARS with different real-world workflow traces. MARS can achieve 5%-60% increased performance compare to state-of-the- art approaches.

Baheri, Betis↗

SU-E-J-181: Magnetic Resonance Image-Guided Radiation Therapy Workflow: Initial Clinical Experience

Purpose: The aims of this work are to describe the workflow and initial clinical experience treating patients with an MRI-guided radiotherapy (MRIGRT) system. Methods: Patient treatments with a novel MR-IGRT system started at our institution in mid-January. The system consists of an on-board 0.35-T MRI, with IMRT-capable delivery via doubly-focused MLCs on three {sup 60} Co heads. In addition to volumetric MR-imaging, real-time planar imaging is performed during treatment. So far, eleven patients started treatment (six finished), ranging from bladder to lung SBRT. While the system is capable of online adaptive radiotherapy and gating, a conventional workflow was used to start, consisting of volumetric imaging for patient setup using visible tumor, evaluation of tumor motion outside of PTV on cine images, and real-time imaging. Workflow times were collected and evaluated to increase efficiency and evaluate feasibility of adding the adaptive and gating features while maintaining a reasonable patient throughput. Results: For the first month, physicians attended every fraction to provide guidance on identifying the tumor and an acceptable level of positioning and anatomical deviation. Average total treatment times (including setup) were reduced from 55 to 45 min after physician presence was no longer required and the therapists had learned to align patients based on soft-tissue imaging. Presently, the source strengths were at half maximum (7.7K Ci each), therefore beam-on times will be reduced after source replacement. Current patient load is 10 per day, with increase to 25 anticipated in the near future. Conclusion: On-board, real-time MRI-guided RT has been incorporated into clinical use. Treatment times were kept to reasonable lengths while including volumetric imaging, previews of tumor movement, and physician evaluation. Workflow and timing is being continuously evaluated to increase efficiency. In near future, adaptive and gating capabilities of the system will be implemented.

60 APPLIED LIFE SCIENCES↗

Simulated Online Adaptive Magnetic Resonance–Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages

Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day” (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model

Purpose: The clinical commissioning of IMRT subject to a magnetic field is challenging. The purpose of this work is to develop a GPU-accelerated Monte Carlo dose calculation platform based on PENELOPE and then use the platform to validate a vendor-provided MRIdian head model toward quality assurance of clinical IMRT treatment plans subject to a 0.35 T magnetic field. Methods: PENELOPE was first translated from FORTRAN to C++ and the result was confirmed to produce equivalent results to the original code. The C++ code was then adapted to CUDA in a workflow optimized for GPU architecture. The original code was expanded to include voxelized transport with Woodcock tracking, faster electron/positron propagation in a magnetic field, and several features that make gPENELOPE highly user-friendly. Moreover, the vendor-provided MRIdian head model was incorporated into the code in an effort to apply gPENELOPE as both an accurate and rapid dose validation system. A set of experimental measurements were performed on the MRIdian system to examine the accuracy of both the head model and gPENELOPE. Ultimately, gPENELOPE was applied toward independent validation of patient doses calculated by MRIdian’s KMC. Results: An acceleration factor of 152 was achieved in comparison to the original single-thread FORTRAN implementation with the original accuracy being preserved. For 16 treatment plans including stomach (4), lung (2), liver (3), adrenal gland (2), pancreas (2), spleen(1), mediastinum (1), and breast (1), the MRIdian dose calculation engine agrees with gPENELOPE with a mean gamma passing rate of 99.1% ± 0.6% (2%/2 mm). Conclusions: A Monte Carlo simulation platform was developed based on a GPU- accelerated version of PENELOPE. This platform was used to validate that both the vendor-provided head model and fast Monte Carlo engine used by the MRIdian system are accurate in modeling radiation transport in a patient using 2%/2 mm gamma criteria. Future applications of this platform will include dose validation and accumulation, IMRT optimization, and dosimetry system modeling for next generation MR-IGRT systems.

60 APPLIED LIFE SCIENCES↗

A high-throughput experimentation platform for data-driven discovery in electrochemistry

Automating electrochemical analyses combined with artificial intelligence is poised to accelerate discoveries in renewable energy sciences and technologies. This study presents an automated high-throughput electrochemical characterization (AHTech) platform as a cost-effective and versatile tool for rapidly assessing liquid analytes. The Python-controlled platform combines a liquid handling robot, potentiostat, and customizable microelectrode bundles for diverse, reproducible electrochemical measurements in microtiter plates, minimizing chemical consumption and manual effort. To showcase the capability of AHTech, we screened a library of 180 small molecules as electrolyte additives for aqueous zinc metal batteries, generating data for training machine learning models to predict Coulombic efficiencies. Key molecular features governing additive performance were elucidated using Shapley Additive exPlanations and Spearman’s correlation, pinpointing high-performance candidates like cis-4-hydroxy-d-proline, which achieved an average Coulombic efficiency of 99.52% over 200 cycles. The workflow established herein is highly adaptable, offering a powerful framework for accelerating the exploration and optimization of extensive chemical spaces across diverse energy storage and conversion fields.

Lin, Dian-Zhao [Johns Hopkins University, Baltimor↗

Foundation Models for Zero-Shot Segmentation of Scientific Images without AI-Ready Data

Zero-shot and prompt-based models have excelled at visual reasoning tasks by leveraging large-scale natural image corpora, but they often fail on sparse and domain-specific scientific image data. We introduce Zenesis, a no-code interactive computer vision platform designed to reduce data readiness bottlenecks in scientific imaging workflows. Zenesis integrates lightweight multimodal adaptation for zero-shot inference on raw scientific data, human-in-the-loop refinement, and heuristic-based temporal enhancement. We validate our approach on Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) datasets of catalyst-loaded membranes. Zenesis outperforms baselines, achieving an average accuracy of 0.947, Intersection over Union (IoU) of 0.858, and Dice score of 0.923 on amorphous catalyst samples; and 0.987 accuracy, 0.857 IoU, and 0.923 Dice on crystalline samples. These results represent a significant performance gain over conventional methods such as Otsu thresholding and standalone models like the Segment Anything Model (SAM). Zenesis enables effective image segmentation in domains where annotated datasets are limited, offering a scalable solution for scientific discovery.

Mukherjee, Shubhabrata↗

PPI DataHub Project Data Package: S. elongatus PCC 7942 Limited Proteolysis and Thermal Proteome Profiling Structural Proteomics (JM-PB-DP3)

The purpose of this experiment was to investigate structural alterations in proteins involved in central carbon metabolism and photosynthetic electron transfer pathways in Synechococcus elongatus PCC 7942. Sample data was obtained from S. elongatus cell lysates using three complementary mass spectrometry (MS) techniques using limited proteolysis (LiP-MS), thermal proteome profiling (TPP-MS), and redox enrichment (Redox-MS) in evaluating alterations solvent accessibility and structural stability caused by light perturbation at the molecular level. Experimentally processed sample data for LiP and TPP proteomic datasets were derived from the same cell culture stock, prepared simultaneously in parallel, and acquired by mass spectrometry. Processed datasets are openly accessible from the download button and contain secondary processed proteomic results files, computed outputs, and supporting metadata materials. Experimental samples processed for LiP-MS label-free quantification (LFQ) or TPP-MS tandem mass tag (TMT) 10-plex were acquired using a Q-Exactive HF-X mass spectrometer and processed/compiled using either MSGF+ (v2024.03.26) or ​​​​PlexedPiper for proteome evaluation. Additional software supporting downstream proteomic analysis include FragPipe (v.4.0), MSFragger (v.22.1), and an adapted Microbial Isolate LiP Analysis Workflow (located at Zenodo). Processed proteomic data downloads include a sample naming key, normalized quantification results files, and processed protein annotated abundance files.

59 BASIC BIOLOGICAL SCIENCES↗

Subtask 1.5 – CO2 Injection Monitoring with an Optimized Scalable, Automated, Semipermanent Seismic Array

The scalable, automated, semipermanent seismic array (SASSA) method is a flexible and relatively cost-effective surface geophysical method for regular time-lapse monitoring of the movement of injected carbon dioxide (CO2) in a reservoir for CO2 enhanced oil recovery (EOR) or geologic CO2 storage operations. It has the advantages of a low-environmental-footprint while monitoring regions of a reservoir from the surface without the need for a regular grid distribution of receivers. Automated data collection is possible. As only time-lapse amplitude changes at the reservoir level due to CO2 movement within the reservoir are monitored, the turnaround time to deliver results from the SASSA method can be short, without the need for long, time-consuming data-processing workflows. As data is collected and processed, incremental information can be provided to the field operator. The Energy & Environmental Research Center (EERC) conducted a SASSA field test from September 2018 to November 2020 in a portion of the Bell Creek Field in Montana, which implemented new CO2 EOR field activities during the study period. Lessons learned from a proof-of-concept study were incorporated to improve the data quality of the SASSA method and demonstrate the viability of the technology. The EERC implemented several enhancements to improve data quality, including 1) an iterative survey design, which allowed placing the receivers in strategic locations where the movement of the CO2 in the reservoir could be tracked with minimum interference by the cultural noise in the study area; 2) the use of powerful seismic sources in the form of surface orbital vibrators, and 3) data acquisition during optimal periods. History-matched reservoir simulation was performed to predict gas saturation and pressure response induced by CO2 injection in the study area. The results were compared with the SASSA-measured responses to CO2 injection as a partial validation technique. A match between the two methods was observed for most of the SASSA points predicted to have intersected a CO2 saturation change. The validated results provide confidence that the SASSA method can be used independently as a CO2 saturation monitoring technique. As data are collected and processed, incremental information can be provided to the field operator. The critical components of the SASSA workflow for a successful application of the method are the following: Iterative survey design with information about CO2 injection activities from the oilfield operator. A detailed CO2 injection plan is the key driver to select the strategic monitoring location of the SASSA sensors. After this information is incorporated in the initial distribution of sources and receivers in the study area, high-resolution satellite images are used to identify ground locations not affected by cultural noise sources, such as power lines, pipelines/flow lines, or roadways. In the next iteration of the survey design, a scouting trip to the study area is needed to understand more details of the noise sources identified in the previous step and the intensity of the field activities that can also generate noise during the monitoring. Integrating the information from the scouting trip into the survey design to select the optimum source and receiver locations is the final step. Noise attenuation. The variety of noise types during seismic monitoring of an oil field is enormous. Tailored noise characterization and processing at a node-by-node level can enhance the performance and sensitivity of the SASSA technique. Future advancements that could improve the efficiency and application of the SASSA technology include: Gaining a better understanding of the noise field produced by the seismic source to aid the choice of receiver location. Surface noise from the source can overwhelm the small signal changes due to CO2 that the SASSA method measures. Improved data-processing workflow to automatically analyze and adapt to dynamic noise conditions associated with industrial settings. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE- FE0024233.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Boundary-Aware Adversarial Learning Domain Adaption and Active Learning for Cross-Sensor Building Extraction

The use of convolutional neural networks (CNNs) for building extraction from remote sensing images has been widely studied and many public datasets have been made available for accelerating development of these CNN models. Yet adapting pretrained models at scale in real-world scenarios remains a challenging task. The main barrier is that certain new labels are still needed to compensate for domain shifting between the labeled data and new images that potentially cover new geographic locations or that are from a different sensor. In this article, we propose to add informatively labeled samples from a new image pool under the paradigm of active learning. To select the most useful samples based on model uncertainty, we first tackle the problem of uncalibrated uncertainty estimation due to distribution shifting by adapting feature extractors with boundary-based adversarial learning. Calibrated uncertainty is used as the query criterion in the active learning process, where the most uncertain samples are selected for annotation and included for model retraining. The proposed workflow was tested with three data pairs in which each workflow represents a scenario often encountered in real-world applications, including adapting pretrained models to new images collected with different sensors or to new geographic areas where appearances and types of buildings are very different. Compared to several baselines, including random sampling, temperature scaling (a well-known uncertainty calibration technique), different query strategies, and active domain adaptation methods, the proposed workflow shows that strategically querying a smaller set of samples for labeling achieves comparable or better building extraction performance. The proposed method reduces the number of labeled samples required to achieve sufficient model accuracy, thus significantly reducing hundreds of person-hours for labeled data creation. In addition, we include a few considerations when deploying this workflow in a GPU cluster that can be easily adapted to achieve operational building extraction model retraining.

97 MATHEMATICS AND COMPUTING↗

Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications

Purpose: To demonstrate the feasibility of online adaptive magnetic resonance (MR) image guided radiation therapy (MR-IGRT) through reporting of our initial clinical experience and workflow considerations. Methods and Materials: The first clinically deployed online adaptive MR-IGRT system consisted of a split 0.35T MR scanner straddling a ring gantry with 3 multileaf collimator-equipped {sup 60}Co heads. The unit is supported by a Monte Carlo–based treatment planning system that allows real-time adaptive planning with the patient on the table. All patients undergo computed tomography and MR imaging (MRI) simulation for initial treatment planning. A volumetric MRI scan is acquired for each patient at the daily treatment setup. Deformable registration is performed using the planning computed tomography data set, which allows for the transfer of the initial contours and the electron density map to the daily MRI scan. The deformed electron density map is then used to recalculate the original plan on the daily MRI scan for physician evaluation. Recontouring and plan reoptimization are performed when required, and patient-specific quality assurance (QA) is performed using an independent in-house software system. Results: The first online adaptive MR-IGRT treatments consisted of 5 patients with abdominopelvic malignancies. The clinical setting included neoadjuvant colorectal (n=3), unresectable gastric (n=1), and unresectable pheochromocytoma (n=1). Recontouring and reoptimization were deemed necessary for 3 of 5 patients, and the initial plan was deemed sufficient for 2 of the 5 patients. The reasons for plan adaptation included tumor progression or regression and a change in small bowel anatomy. In a subsequently expanded cohort of 170 fractions (20 patients), 52 fractions (30.6%) were reoptimized online, and 92 fractions (54.1%) were treated with an online-adapted or previously adapted plan. The median time for recontouring, reoptimization, and QA was 26 minutes. Conclusion: Online adaptive MR-IGRT has been successfully implemented with planning and QA workflow suitable for routine clinical application. Clinical trials are in development to formally evaluate adaptive treatments for a variety of disease sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗