Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

Plasma jet effects on the ionospheric plasma

Heavy ion beams were injected into the ionospheric plasma (experiments ARCS 1 and ARCS 2). In ARCS 1, operation of a 25eV argon ion source, mounted on a plasma diagnostic payload, produced an accelerated electron population; broadband electric field turbulence; large, spin synchronized electric field perturbations; and depletions of thermal ions. In ARCS 2, the ion source was deployed upward along the local magnetic field direction away from the diagnostic payload, and observed effects are contained within several meters of the ion source. However, enhanced wave levels near the LHR frequency are observed at distances up to 1 km, as are the injected ions themselves. A measurement of the dominant wavelength of the enhanced waves is consistent with an inference based upon the accelerated electron population seen in ARCS 1. This electron population is not evident during ARCS 2.

Moore, T. E.↗

Single-Shot Reconstruction of Electron Beam Longitudinal Phase Space in a Laser Wakefield Accelerator

We report on a single-shot longitudinal phase-space reconstruction diagnostic for electron beams in a laser wakefield accelerator via the experimental observation of distinct periodic modulations in the angularly resolved spectra. Such modulated angular spectra arise as a result of the direct interaction between the ultrarelativistic electron beam and the laser driver in the presence of the wakefield. A constrained theoretical model for the coupled oscillator, assisted by a genetic algorithm, can recreate the experimental electron spectra and, thus, fully reconstructs the longitudinal phase-space distribution of the electron beam with a temporal resolution of approximately 1.3 fs. In particular, it reveals the slice energy spread of the electron beam, which is important to measure for applications such as x-ray free electron lasers. In our experiment, the root-mean-square energy spread retrieved is bounded at 9.9 MeV, corresponding to a 0.9%–3.0% relative spread, despite the overall GeV energy beam having approximately 100% relative energy spread.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive autoencoder latent space tuning for more robust machine learning beyond the training set for six-dimensional phase space diagnostics of a time-varying ultrafast electron-diffraction compact accelerator

In this work, we present a general adaptive latent space tuning approach for improving the robustness of machine learning tools with respect to time variation and distribution shift. We demonstrate our approach by developing an encoder-decoder convolutional neural network-based virtual 6D phase space diagnostic of charged particle beams in the HiRES ultrafast electron diffraction (UED) compact particle accelerator with uncertainty quantification. Our method utilizes model-independent adaptive feedback to tune a low dimensional 2D latent space representation of ~1 million dimensional objects which are the 15 unique 2D projections (x, y),...,(z, p z ) of the 6D phase space (x, y, z, p x , p y , p z ) of the charged particle beams. We demonstrate our method with numerical studies of short electron bunches utilizing experimentally measured UED input beam distributions.

43 PARTICLE ACCELERATORS↗

Patterns of Care, Tolerability, and Safety of the First Cohort of Patients Treated on a Novel High-Field MR-Linac Within the MOMENTUM Study: Initial Results From a Prospective Multi-Institutional Registry

High-field magnetic resonance-linear accelerators (MR-Linacs), linear accelerators combined with a diagnostic magnetic resonance imaging (MRI) scanner and online adaptive workflow, potentially give rise to novel online anatomic and response adaptive radiation therapy paradigms. The first high-field (1.5T) MR-Linac received regulatory approval in late 2018, and little is known about clinical use, patient tolerability of daily high-field MRI, and toxicity of treatments. Herein we report the initial experience within the MOMENTUM Study (NCT04075305), a prospective international registry of the MR-Linac Consortium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

Realizing the scientific program with polarized ion beams at the future BNL Electron Ion Collider

Polarized ion beams at the Electron Ion Collider (EIC) are essential to address some of the most important open questions at the twenty-first century frontiers of understanding of the fundamental structure of matter. Here, in this work, we summarize the science case and identify polarized 2 H, 3 He, 6 Li, and 7 Li ion beams as critical technology that will enable experiments which address the most important science. Furthermore, we discuss the required ion polarimetry and spin manipulation at the EIC. The current EIC accelerator design is presented. We identify a significant research and development effort across national and international laboratories and universities that is required over about a decade to realize the polarized ion beams and estimate (based on previous experience) that it will require about 20 full-time equivalent (FTE) over 10 years (or a total of about 200 FTE-years) of personnel, including graduate students, postdoctoral researchers, technicians, and engineers. Attracting, educating, and training a new generation of physicists in experimental spin techniques will be essential for the successful realization. Artificial intelligence and machine learning are seen as having significant potential for both acceleration of research and development and amplification of discovery in the optimal realization of this unique quantum technology on a cutting-edge collider. The research and development effort is synergistic with research in atomic physics and fusion energy science.

43 PARTICLE ACCELERATORS↗

Improved calibration of rf cavities for relativistic electron beams: Effects of secondary corrections and experimental verification

In the aspect of longitudinal beam bunching, the bunching strength can be controlled by the rf cavity phase and voltage. However, these machine parameters are different from those that interact with the beam itself. In order to gain control of the beam-cavity interaction, cavity calibration must be performed. Furthermore, it relies on fitting the beam energy gain versus cavity phase to a calibration function. Under the conventional assumption of relativistic beam conditions, the calibration function is a first harmonic sinusoidal function (a sinusoidal function with a period of 2π). However, this expression is insufficient for a high-voltage bunching cavity. Due to beam acceleration inside the cavity, an energy bias and a second harmonic function should be included to modify the conventional calibration function, even for a relativistic electron beam. In this paper, we will derive this modification and provide a comparison to both the Coherent Electron Cooling Experiment and the IMPACT T simulation, respectively.

43 PARTICLE ACCELERATORS↗