Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Durability evaluation of a Fe–N–C catalyst in polymer electrolyte fuel cell environment via accelerated stress tests

In this work, an “atomically-dispersed” iron-nitrogen-carbon (Fe–N–C) catalyst was used to provide a systematic comparison of platinum group metal (PGM)-free electrocatalyst degradation as a function of accelerated stress tests (ASTs) in an acidic polymer electrolyte fuel cell (PEFC). It was determined that the majority of catalyst degradation was caused by cell operation in presence of O 2 . In contrast, potential cycling of the Fe–N–C-containing cathode under inert atmosphere over typical PEFC cathode operation from 0.95 to 0.6 V had little to no effect. The increase in kinetic overpotential is shown to be the major source of the PEFC performance decrease during the ASTs. These results continue to showcase the need for development of robust PGM-free electrocatalysts in concert with improved electrochemical performance.

25 ENERGY STORAGE↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

FY2022 Status Report: Cold Spray for Canister SCC Mitigation and Repair

This progress report describes work performed during FY22 at Sandia National Laboratories (SNL) to assess the corrosion performance of cold spray coatings to enable optimization of cold spray for the purposes of mitigation and/or repair of potentially susceptible regions, corrosion, or stress corrosion cracking (SCC) in austenitic stainless steel for spent nuclear fuel (SNF) storage. Of particular concern is SCC, by which a through-wall crack could potentially form in a canister outer wall over time intervals that may be shorter than possible dry storage times. In FY21, initial corrosion explorations of cold spray coating were evaluated and in FY22, an expanded set of cold spray coatings with in-depth analysis of post-exposure accelerated testing was explored. Additionally, relevant atmospheric exposure testing was carried out and initial results are presented herein. The corrosion attack from the accelerated testing and more realistic atmospheric exposures environments were compared to identify potentially deleterious factors for corrosion as well as help to understand the applicability of accelerated testing for cold spray optimization. This initial analysis will help to enable optimization of the corrosion resistance cold spray, one of the more promising coating and repair techniques, for potential application in an SNF environment. Learnings from both are summarized, and implications and future work are presented in this report.

36 MATERIALS SCIENCE↗

Computational Modeling of Photovoltaic Mini-Modules Undergoing Accelerated Stress Testing

A finite element model of a four-cell photovoltaic mini-module was developed and compared to experimental results from an accelerated stress test protocol in order to validate that computational models can accurately represent their physical counterparts when subjected to mechanical loading and to assess mini-module representativeness against full scale photovoltaic modules. Deflected shapes across the simulated mini-modules were compared to measured mini-module shapes when subjected to various pressure loads. Displaced mini-module shape results constrained to the experimental protocols of 0.4 mm and 1.1 mm of displacement at the mini-module center were compared to experimental results of full-size modules subjected to module qualification test load levels of 1.0 kPa and 2.4 kPa, to assess if the bending of mini-modules was representative of full-sized modules under the load. Temperature cycling was incorporated into the model to simulate the impacts of stress due to thermal expansion of the backsheet and cells. A preliminary uncertainty analysis was performed to show how variations in material properties and geometric parameters change the simulation results.

computational modeling↗

Examining Light-Induced Degradation with Combined-Accelerated Stress Testing

While further understanding is sought, the results suggest that a module can show no degradation in performance through a qualification test light soak, (IEC 61215: 2021 MQT 19.1 requirement of 10 kW minimum on one side). Yet, such cells may degrade significantly by LID under conditions within the statistical extremes of the natural environment applied in combined-accelerated stress testing (CAST).

combined-accelerated stress testing↗

Validation of Advanced Photovoltaic Module Materials and Processes by Combined-Accelerated Stress Testing (C-AST)

Tessolar module technology was developed to allow the incorporation of 5 incremental module material innovations. Combined, these innovations may improve the efficiency and durability of the standard silicon cell module. The innovations evaluated are: electrically conductive adhesive (ECA) replacing soldering of tabbing ribbons, light-capturing ribbon (LCR), silicone encapsulant, 2 mm front glass with backsheet, and a polymer-composite module frame. Tessolar-constructed individually encapsulated cells incorporating the material innovations are used to assemble 60-cell modules. 2 x 2 cell mini-modules of the same materials were produced for combined-accelerated stress testing (C-AST). C-AST results demonstrate that the 2 x 2 cell mini-module of Tessolar construction out-performed mini-modules using both ECA with EVA and standard solder with EVA constructions in power production over 108 cycles of testing.

14 SOLAR ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Prototype Installation and Testing Awardee: Accelerate Wind

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Accelerate Wind for Prototype Installation and Testing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

Electrolyzer Performance Loss from Accelerated Stress Tests and Corresponding Changes to Catalyst Layers and Interfaces

Stress tests are developed for proton exchange membrane electrolyzers that utilize low catalyst loading, elevated potential, and frequent cycling with square- and triangle-waves to accelerate anode catalyst layer degradation during intermittent operation. Kinetics drive performance losses (ohmic/transport secondary) and are accompanied by decreasing exchange current density, decreasing cyclic voltammetric capacitance, and increasing polarization resistance. Decreased kinetics are likely due to a combination of iridium (Ir) migration into electrochemically inaccessible locations in the anode or membrane, Ir particle growth (supported by X-ray scattering), changes in the extent of the Ir oxidation state (supported by X-ray absorption spectroscopy), and anode catalyst layer reordering. Decreasing catalyst/transport layer contact and catalyst/membrane interfacial tearing may add contact resistances and account for increasing ohmic losses. Performance losses for low and moderate catalyst loading, as well as from accelerated and model wind/solar cycling protocols, were likewise dominated by kinetics but vary in severity. Additionally, accelerated cycling (1 cycle per minute) appears to reasonably accelerate relevant loss mechanisms and can be used to project electrolyzer lifetime from anode deterioration. Ongoing accelerated stress test development and studies into performance loss mechanisms will continue to be critical as electrolysis shifts to intermittent power and low-cost applications.

30 DIRECT ENERGY CONVERSION↗

Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.

bifacial modules↗

Using Explainable Artificial Intelligence to Predict Perovskite Solar Cell Electrical Metastability from Operando Photoluminescence Images in Accelerated Stress Testing

Metal halide perovskite (MHP) solar cells exhibit a metastable response to bias governed by coupled ionic–electronic processes, complicating the conventional reciprocity relation between luminescence intensity and device open-circuit voltage (V oc ). This limits the use of luminescence as a diagnostic for device screening or accelerated stress testing, motivating new approaches that can interpret photoluminescence (PL) signals under nonequilibrium conditions. From the artificial intelligence perspective, we develop an explainable deep learning framework that integrates convolutional neural networks (CNN), long short-term memory (LSTM) layers, and an attention mechanism to learn spatiotemporal features from operando photoluminescence PL image sequences. The model achieves a mean absolute error of ±0.027 V in predicting open-circuit voltage transients and reduces extreme-tail errors by up to 78% compared to physics-based reciprocity calculations. Gradient-weighted Class Activation Mapping (Grad-CAM) provides interpretability by highlighting physically meaningful regions such as electrode edges and emergent defect features. From the engineering application perspective, this framework enables accurate, contactless prediction of device V oc and identification of degradation-relevant features during accelerated aging of perovskite solar cells. This approach demonstrates how explainable AI can enhance operando diagnostics and reliability analysis in photovoltaic devices under nonequilibrium conditions.

14 SOLAR ENERGY↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

ACCELERATED CREEP TEST (ACT) QUALIFICATION OF CREEP RESISTANCE USING THE WCS CONSTITUTIVE MODEL AND STEPPED ISOSTRESS METHOD (SSM)

In this study, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire-Cano-Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing (CCT) is a long-term continuous process, in fact, the ASME B&PV III requires that 10,000+ hours of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle (TTSSP) that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The stepped isostress method (SSM) has been developed which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750°C and predictions are compared to CCT data. The WCS model has proven to make long-term predictions for stress-rupture, minimum-creep-strain-rate (MCSR), creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are post-audit validated using the National Institute of Material Science (NIMS) database. Similarly, the MCSR predictions are compared from previous studies. Finally the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and Industrial Gas Turbines (IGT).

36 MATERIALS SCIENCE↗

Photovoltaic Cable Jackets: A Comparison of Representative Products Using Combined-Accelerated Stress Testing [Slides]

Photovoltaic (PV) cables facilitate the distribution of electricity collected from modules to the energy grid. Durable cabling enables continuous operation of PV installations, whereas cables with a lifetime less than the modules must be replaced - reducing electricity generation and adding to the operating expense. This study primarily focusses on the aging of the key cable types using the combined-accelerated stress testing (C-AST) protocol. Representative cables for utility, building, and control/auxiliary applications were examined. Cable jacket materials examined include: polyolefin, polyethylene, polyamide, poly(vinyl chloride), chlorinated polyethylene, thermoplastic elastomer, and ethylene propylene diene monomer rubber. Specimen characterizations applied include: optical microscopy, mechanical profilometry, instrumented indentation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). A variety of performance and durability characteristics were observed, depending on the base material, polymer formulation, and jacket color. The results from C-AST are analyzed and discussed relative to a recent industry survey on electronic balance of system components in addition to a recent study where similar cables were aged using steady state ultraviolet weathering (International Electrotechnical Commission Technical Specification 62788-7-2). Recommendations are made for the screening, industry qualification, and service life prediction of PV cable jackets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerated Creep Test Qualification of Creep-Resistance Using the Wilshire–Cano–Stewart Constitutive Model and Stepped Isostress Method

In this paper, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire–Cano–Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing is a long-term continuous process; in fact, the ASME B&PV III requires that 10,000+ h of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The SSM has been developed, which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750 °C and predictions are compared to conventional creep testing data. The WCS model has proven to make long-term predictions for stress-rupture, MCSR, creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are postaudit validated using the National Institute of Material Science database. Similarly, the MCSR predictions are compared from previous studies. Finally, the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and industrial gas turbines.

42 ENGINEERING↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗