Probing autoionization decay lifetimes of the 4d−16ℓ core-excited states in xenon using attosecond noncollinear four-wave-mixing spectroscopy

The decay of core-excited states is a sensitive probe of autoionization dynamics and correlation effects in many-electron systems, occurring on ultrafast timescales. Xenon, with its dense manifold of autoionizing resonances that can be coupled with near-infrared light, provides a platform to investigate these processes. In this work, the autoionization decay lifetimes of 4d-16ℓ (ℓ = s, p, d, …) core-excited states in xenon atoms are probed with extreme ultraviolet (XUV) attosecond noncollinear four-wave-mixing (FWM) spectroscopy. The 4d{5/2,3/2}-16p XUV-bright states (optically dipole-allowed) exhibit decay lifetimes of ∼6 fs, which is consistent with spectator-type decay. In contrast, the 4d{5/2,3/2}-16s and 4d{5/2,3/2}-16d XUV-dark states (optically dipole forbidden) show longer decay lifetimes of ∼20 fs. Photoionization calculations confirm that all core-hole states with 4d character should decay via spectator channels in ≤6 fs, suggesting that the apparently longer dark-state decay times arise from an alternative mechanism. A few-level simulation of the FWM process shows that the inclusion of a nearby, longer-lived dark state can mimic the experimental FWM signal, suggesting population cycling with a second electronic state with non-4d character. Ab initio calculations support the presence of such multielectron excited states in the 60-70 eV range. These results demonstrate that FWM signals can encode coupled-state dynamics when probing complex systems, highlighting the importance of combining theoretical and experimental approaches to disentangle accurate core-level decay pathways and lifetimes.

Puskar, Nicolette G↗

Validation of the VUV-reflective coating for next-generation liquid xenon detectors

Abstract Coating detector materials with films highly reflective in the vacuum ultraviolet region improves sensitivity of the next-generation rare-event detectors that use liquid xenon. In this work, we investigate the MgF 2 -Al-MgF 2 coating designed to achieve high reflectance at 175 nm, the mean wavelength of liquid xenon (LXe) scintillation. The coating was applied to an unpolished, passivated copper substrate mimicking a realistic detector component of the proposed nEXO experiment, as well as to two unpassivated substrates with “high” and “average” levels of polishing. After confirming the composition and morphology of the thin-film coating using TEM and EDS, the samples underwent reflectance measurements in LXe and gaseous nitrogen (GN2). Measurements in LXe exposed the coated samples to -100°C for several hours. No peeling of the coatings was observed after several thermal cycles. Polishing is found to strongly correlate with the measured specular reflectance (R spec ). In particular, 5.8(5)% specular spike reflectance in LXe was measured for the realistic sample at 20° of incidence, while the values for similar angles of incidence on the high and average polish samples are 62.3(1.3)% and 27.4(7)%, respectively. At large angles (66°–75°), theR spec in LXe for the three samples increases to 23(5)%, 80(8)%, and 84(18)%, respectively. The R spec at around 45° was measured in both GN2 and LXe for average polish sample and shows a reasonable agreement. Importantly, the total reflectance of the samples is comparable and estimated to be 92(8)%, 85(8)%, and 83(8)% in GN2 for the realistic, average, and high polish samples, respectively. This is considered satisfactory for the next-generation LXe experiments that could benefit from using reflective films, such as nEXO and DARWIN, thus validating the design of the coating.

Instruments & Instrumentation↗

Quartz fluorescence backgrounds in xenon particle detectors

It has been known for almost a decade that delayed photon noise with a power law time profile follows scintillation pulses in liquid xenon particle detectors. The origin of the noise has remained unknown, and in the past two years, has become an overwhelming background for low-threshold dark matter searches aimed at 𝒪⁡(10) GeV dark matter particle masses, as well as measurements of coherent neutrino-nucleus scattering of 8 B solar neutrinos. We have performed a comprehensive series of tests in a small liquid xenon cell at LBL, from which we conclude that the dominant component of this delayed photon noise is due to UV-induced fluorescence of quartz photosensor windows.

crystal optics↗

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon fluoride solutions effective as fluorinating agents

Solutions of xenon fluorides in anhydrous hydrogen fluoride have few disruptive effects and leave a residue consisting of gaseous xenon, which can be recovered and refluorinated. This mild agent can be used with materials which normally must be fluorinated with fluorine alone at high temperatures.

Hyman, H. H.↗

Extinct lunar radio activities - Xenon from Pu-244 and I-129 in Apollo 14 breccias.

Two Apollo 14 breccias have been found to contain xenon from the spontaneous fission of 82 my Pu-244. A third contains 60 times as much fission xenon as local uranium can account for and is probably of similar character. One of the breccias shows a Xe-129 excess most likely due to the decay of 17 my I-129. That these components can be separated and identified at all implies that complete isotopic homogenization has not occurred over a period which encompasses both extinction of these radionuclides and compaction of the breccias into their final form. In this sense isotope pre-history has been preserved in some lunar breccias providing information that pre-dates the formation of the rock itself (as determined by conventional techniques).

Behrmann, C. J.↗

Stimulated emission in multiple-photon-pumped xenon and argon excimers.

A pumping process involving the multiphoton absorption of laser radiation at 3547 and 2660 A is employed in the investigation. Typically, about 25% of the incident pumping radiation is absorbed and effective in producing excimer fluorescence. The four cases studied include 2660-A-pumped argon, 2660-A-pumped xenon, 3547-A-pumped xenon, and 3547-A-pumped argon. Results concerning the on-axis and off-axis fluorescence obtained from the excimers are presented in a graph.

Harris, S. E.↗

Long term spectral irradiance measurements of a 1000-watt xenon arc lamp

Spectral irradiance measurements over the range of 200 to 1060 nm were made on a 1000-watt xenon arc lamp over a period of 1500 hours. Four sets of measurements were made after periods of 70, 525, 1000, and 1500 hours of operation. The lamp (Hanovia Compact Xenon Arc Lamp) was mounted in the NASA Solar Irradiation System. When used in the System, the lamp is used as the radiating source for six test stations. Measurements were made of both the longterm stability (or variation of spectral irradiance as a function of time) and the actual spectral irradiance incident on the test specimen.

Schneider, W. E.↗

Evidence of charge exchange pumping in calcium-xenon system

Presented evidence shows that charge exchanges between xenon ions and calcium atoms may produce an inversion between 5s or 4d and 4p energy levels of calcium ions. The dependence of measured intensity ratios on power input to the xenon plasma indicates that charge exchange pumping of the 5s and 4d levels predominates over electron collisional pumping of these levels.

Chubb, D. L.↗

Experimental investigations of argon and xenon ion sources

The multipole thruster was used to investigate the use of argon and xenon propellants as possible alternatives to the electric thruster propellants of mercury and cesium. The multipole approach was used because of its general high performance level. The design employed, using flat and cylindrical rolled sections of sheet metal, was selected for ease of fabrication, design, assembly, and modification. All testing was conducted in a vacuum facility and the pumping was accomplished by a 0.8 m diffusion pump together with liquid nitrogen cooled liner. Minimum discharge losses were in the 200-250 ev. ion range for both argon and xenon. Flatness parameters were typically in the 0.70-0.75 range.

Kaufman, H. R.↗

Spectrum of carbonaceous-chondrite fission xenon

Estimations of the fission spectrum in xenon isotopes from the progenitor of the strange carbonaceous-chondrite xenon must take account of p-process nucleosynthesis if the latter is the source of anomalous Xe-124, 126. Sample calculations of the p-process yields illustrate the magnitude of the effect, which can greatly increase the estimated Xe-132 fission yield.

Clayton, D. D.↗

A measurement of the relativistic rise in xenon-filled ionisation chambers for cosmic ray iron

The relativistic rise of ionization in a pair of xenon-filled pulse ion chambers was measured for primary iron nuclei during a recent balloon flight. Energy calibration over the range 21.5-60 GeV/n was made with a Freon-12 gas Cerenkov detector. This allowed a comparison with recent calculations of the relativistic rise in xenon counters and an estimate of the ion chamber resolution above 21.5 GeV/n to be made.

Gregory, J. C.↗

Xenon diffusion following ion implantation into feldspar - Dependence on implantation dose

The diffusion properties of xenon implanted into feldspar, a major mineral in meteorites and lunar samples, are investigated in light of the importance of xenon diffusion in the interpretation of early solar system chronologies and the retention time of solar-wind-implanted Xe. Known doses of Xe ions were implanted at an energy of 200 keV into single-crystal plagioclase targets, and depth profiles were measured by alpha particle backscattering before and after annealing for one hour at 900 or 1000 C. The fraction of Xe retained following annealing is found to be strongly dependent on implantation dose, being greatest at a dose of 3 x 10 to the 15th ions/sq cm and decreasing at higher and lower doses. Xe retention is also observed to be unaffected by two-step anneals, or by implantation with He or Ar. Three models of the dose-dependent diffusion properties are considered, including epitaxial crystal regrowth during annealing controlled by the extent of radiation damage, the creation of trapping sites by radiation damage, and the inhibition of recrystallization by Xe during annealing

Melcher, C. L.↗

Performance characteristics of ring-cusp thrusters with xenon propellant

The performance characteristics and operating envelope of several 30-cm ring-cusp ion thrusters with xenon propellant were investigated. Results indicate a strong performance dependence on the discharge chamber boundary magnetic fields and resultant distribution of electron currents. Significant improvements in discharge performance over J-series divergent-field thrusters were achieved for large throttling ranges, which translate into reduced cathode emission currents and reduced power dissipation which should be of significant benefit for operation at thruster power levels in excess of 10 kW. Mass spectrometry of the ion beam was documented for both the ring-cusp and J-series thrusters with xenon propellant for determination of overall thruster efficiency, and lifetime. Based on the lower centerline values of doubly charged ions in the ion beam and the lower operating discharge voltage, the screen grid erosion rate of the ring-cusp thruster is expected to be lower than the divergent-field J-series thruster by a factor of 2.

Patterson, M. J.↗

Performance characteristics of ring-cusp thrusters with xenon propellant

The performance characteristics and operating envelope of several 30-cm ring-cusp ion thrusters with xenon propellant were investigated. Results indicate a strong performance dependence on the discharge chamber boundary magnetic fields and resultant distribution of electron currents. Significant improvements in discharge performance over J-series divergent-field thrusters were achieved for large throttling ranges, which translate into reduced cathode emission currents and reduced power dissipation which should be of significant benefit for operation at thruster power levels in excess of 10 kW. Mass spectrometer of the ion beam was documented for both the ring-cusp and J-series thrusters with xenon propellant for determination of overall thruster efficiency, and lifetime. Based on the lower centerline values of doubly charged ions in the ion beam and the lower operating discharge voltage, the screen grid erosion rate of the ring-cusp thruster is expected to be lower than the divergent-field J-series thruster by a factor of 2.