Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparative operando XPS studies of quasi-Fermi level splitting and open-circuit voltage in CZTSe/CdS and CIGS/CdS junctions and device structures

This contribution describes operando x-ray photoelectron spectroscopy (opXPS) studies of Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTSe) absorber layers and device structures. X-ray-excited valence-band and core-level spectra were acquired on bare absorber surfaces and after CdS and ZnO:Al depositions in standard absorber/CdS/ZnO/ZnO:Al device stacks. OpXPS data sets were acquired at various x-ray fluxes, with and without white-light illumination. From these measurements, quasi-Fermi level splitting (ΔE F ) values in the absorber/CdS junctions were measured directly as a function of excitation conditions. For both CIGS and CZTSe, results show that ..delta..EF proportional to the full open-circuit voltage (V OC ) of the completed devices is present after the deposition of the CdS layer - i.e., E F = qV OC - demonstrating that the so-called V OC deficit in CZTSe solar cells is also present at this stage of processing. The authors find that photoexcitation due to x-rays or stray visible light during XPS or similar measurements can produce measurable photovoltages in materials, absorber/CdS junctions, and finished devices. In situ current density versus voltage measurements on a typical CIGS device reveal that x-ray-induced photoexcitation associated with typical XPS measurement conditions is equivalent to ~3 x 10 -3 suns, which in this study produced V OC = 440 mV. These findings demonstrate that accounting for photoexcitation conditions during XPS or similar measurements can improve band-offset determinations and produce more reliable values for the junction built-in voltage. The implications of the study findings on the CZTSe V OC deficit and device performance are discussed.

36 MATERIALS SCIENCE↗

Guide to Making XPS Measurements on Nanoparticles

This guide briefly summarizes issues and considerations important for the use of X-ray Photoelectron Spectroscopy (XPS) for characterizing nanoparticles, which are important in many areas of science and technology. Because the surfaces play a major role in determining nanoparticle behaviors, XPS is an increasingly useful tool for understanding their properties, including addressing variations and non-reproducibility issues associated with these materials. The unusual physical and chemical behaviors of these particles must be considered in preparing and characterizing these materials. This guide is one of a series intended to highlight best practices in the use of XPS.

Baer, Donald R.↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗

Analysis of nickel sulfoselenide materials by XPS

Metal chalcogenides are of interest as electrocatalysts, battery materials, and more. XPS is a valuable tool for studying changes to these materials before and after catalysis, making reference spectra for the pristine materials valuable. Here, we present XPS spectra for a family of nickel sulfoselenide (NiSSe) materials based on the Ni 3 X 2 crystal structure, Ni 3 S 2-x Se x . XPS surveys and high-resolution spectra of Ni 2p, S 2p, S 2s, Se 3d, Se 3p, and Se 3s were recorded using Al K α radiation.

36 MATERIALS SCIENCE↗

Effects of the low Earth orbit space environment on the surface chemistry of Kapton polyimide film: An XPS study

Kapton H (DuPont Trademark) polyimide specimens exposed to the low earth (LEO) space environment suffered significant weathering with surface erosions of approximately 8.0 microns. Despite these effects, no significant changes in bulk chemistry were observed. X-ray photoelectron spectroscopy (XPS) was used to determine local changes induced from approximately 25 percent in 1980 vintage ground control specimens to nearly 53 percent in space exposed specimens. The greatest increase was observed for the divalent oxygen moieties, although a slight increase in carbonyl oxygen was also measured. Furthermore, the chemical shifts of all XPS peaks of space-exposed Kapton are shifted to higher energy. This is consistent with a higher oxidation state of the space exposed surface. Finally, space exposed specimens had distinct silicon peaks (2p 100 eV and 2s 149 eV) in their XPS spectra in agreement with widespread reports of silicon contamination throughout the LDEF satellite. These results are discussed in terms of surface reactivity of the polyimide exposed to the LEO environment and the chemical nature of contaminants deposited on flight surfaces due to satellite outgassing.

Lee, Myung↗

XPS Study of Plasma- and Argon Ion-Sputtered Polytetrafluoroethylene

The similarity of plasma-polymerized tetrafluoroethylene (PPTFE) and the fluoropolymer film deposited by rf (radio frequency) plasma sputtering (SPTFE) of polytetrafluoroethylene (PTFE), noted earlier in the literature, has been reconfirmed. FT-IR (Fourier Transform Infrared), XPS (X ray Photoelectron Spectroscopy) and UV (ultraviolet) spectroscopy has been employed in apparently the first study to involve preparation of PPTFE and SPTFE in the same reactor and under comparable low-power plasma conditions. Most of the work concerned the use of He or Ar as sputtering gas, but some runs were also carried out with the other rare gases Ne, Kr and Xe. The C1s XPS spectra of SPTFE films displayed a relatively higher content of CF2 groups, and yielded higher F/C (fluorine / carbon) ratios, than PPTFE films, while the SPTFE films were somewhat more transparent in the UV than PPTFE. The F/C ratios for SPTFE were essentially independent of the rare gas used for sputtering. Increasing rf power from 10 to 50 W for Xe plasma-sputtering of PTFE resulted in successively lower F/C ratios (1.55 to 1.21), accompanied by sputtering of the glass reactor occurring at 40 W and above. Some limited XPS, FT-IR and UV data are presented on Ar ion-sputtered PTFE.

Golub, Morton A.↗

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗

Selective thermal evolution of native oxide layer in Nb and Nb$_3$Sn-coated SRF grade Nb: An in-situ angular XPS study

This contribution discusses the results of an in-situ angular XPS study on the thermal evolution of the native oxide layer on Nb3Sn and pure Nb. XPS data were recorded with conventional spectrometers using an AlK(alpha) X-ray source for spectra collected up to 600 C, and an MgK(Alpha) X-rays source for temperatures above 600 C. The effect of the thickness, composition, and thermal stability of that oxide layer is relevant to understanding the functional properties of superconducting radiofrequency (SRF) cavities used in particle accelerators. There is a consensus that oxide plays a role in surface resistance (Rs). The focus of this study is Nb3Sn, which is a promising material that is used in the manufacturing of superconducting radiofrequency (SRF) cavities as well as in quantum sensing, and pure Nb, which was included in the study for comparison. The thermal evolution of the oxide layer in these two materials is found to be quite different, which is ascribed to the influence of the Sn atom on the reactivity of the Nb atom in Nb3Sn films. Nb and Sn atoms in this intermetallic solid have different electronegativity, and the Sn atom can reduce electron density around neighbouring Nb atoms in the solid, thus reducing their reactivity for oxygen. This is shown in the thickness, composition, and thermal stability of the oxide layer formed on Nb3Sn. The XPS spectra were complemented by grazing incident XRD patterns collected using the ESRF synchrotron radiation facility. The results discussed herein shed light on oxide evolution in the Nb3Sn compound and guide its processing for potential applications of the Nb3Sn-based SRF cavities in accelerators and other superconducting devices.

Cano, Arely↗

Effects of non-monochromaticity in laboratory XPS: Representative example of pyrimidine

The Mg and Al K α radiation used in standard laboratory sources for X-Ray Photoelectron Spectroscopy, XPS, is not naturally monochromatic because the spin orbit splitting of the Mg and Al 2p shells is not normally resolved. However, since the 2p spin-orbit splitting of the K α1 and K α2 X-Rays in these light atoms is small, it is normally ignored. In the present work, the consequences of the departure from monochromaticity is explicitly shown to be extremely small for the representative case of the C(1 s) ionizations in the XPS of the pyrimidine molecule. Furthermore, this conclusion is general and does not depend on the particular molecule studied since the K α1 and K α2 BE splittings reflect the spin-orbit splittings in the X-Ray source.

Binding Energies (BEs)↗

Deriving Stable Peak Models to Fit Complex XPS Data From Cu Contaminated Pt Electrocatalysts

X-ray Photoelectron Spectroscopy spectra peak models, designed to partition photoemission signals emanating from different elements or chemical states within an atom, are fitted to data limited to an energy interval over which inelastically scattered photoemission signal can be estimated. While the choice of background approximation and line shapes of components to the peak model requires careful consideration, the energy interval used to define the data to which the peak model is optimized has a significant impact on the final peak model. The relationship between the background intensity and data intensity at the start and end of the energy interval dictates the line shapes used in the peak model. In this work, we devise a method to peak fit a complex overlapping Cu 3p and Pt 4f XPS peak structure to perform the elemental quantification. We first use an Al 2s peak to illustrate how background curves approach data at the limits of the energy interval over which the background is defined, influencing the analysis of XPS spectra. Next, we demonstrate the nature of interactions between specific line shapes (Voigt and pseudo-Voigt profiles) suitable for photoemission peaks and a specific background curve (Shirley) and a peak model is presented that includes components to the peak model that accommodates background intensity during fitting of the peak model to data. The peak model allowed for quantification of the contributions of Pt 4f peaks emanating from the substrate that exhibits strong asymmetry in the presence of the inhomogeneously distributed Cu species, mostly of Lorentzian character.

XPS↗

Combining PCA and nonlinear fitting of peak models to re-evaluate C 1s XPS spectrum of cellulose

Cellulose is an example of a material that responds to XPS by the creation of new chemistry not present in the as-received sample. While improvements in instrumentation may be seen in general as beneficial to surface science, recent studies have shown that the consequences for some materials are detrimental. Here, in this work, these problems are illustrated through an analysis of cellulose spectra obtained during a degradation study. C 1s spectra are decomposed into two well-formed component curves that are open to chemical interpretation. In particular, a component-curve representative of pure cellulose is obtained as well as a second component curve that implies cellulose is degraded through the creation of carbon chemistry involving C—O, C$=$O and O—C$=$O. Since cellulose is a crystalline material, formed through the alignment of molecules under the influence of hydrogen bonds, the analysis and findings presented in this paper are relevant to any material analyzed by XPS whose properties are dependent on hydrogen bonds. The analysis techniques are based on an informed vectorial approach, which extracts directly from data spectral shapes that are used to monitor sample degradation via linear least squares optimization. Related mathematics of Principal Component Analysis and linear analysis are presented.

36 MATERIALS SCIENCE↗

The Interpretation of XPS Spectra: Insights Into Materials Properties

We review basic and advanced concepts needed for the correct analysis of XPS features. We place these concepts on rigorous foundations and explore their physical and chemical meanings without stressing the derivation of the mathematical formulations, which can be found in the cited literature. The significance and value of combining theory and experiment is demonstrated by discussions of the physical and chemical origins of the main and satellite XPS features for a variety of molecular and condensed phase materials.

Environmental Molecular Sciences Laboratory↗

Quantifying the Impact of Nanoparticle Coatings and Non-uniformities on XPS Analysis: Gold/silver Core-shell Nanoparticles

Abstract or short description: Spectral modeling of photoelectrons can serve as a valuable tool when combined with X-ray photoelectron spectroscopy (XPS) analysis. Herein, a new version of the NIST Simulation of Electron Spectra for Surface Analysis (SESSA 2.0) software, capable of directly simulating spherical multilayer NPs, was applied to model citrate stabilized Au/Ag-core/shell nanoparticles (NPs). The NPs were characterized using XPS and scanning transmission electron microscopy (STEM) to determine the composition and morphology of the NPs. The Au/Ag-core/shell NPs were observed to be polydispersed in size, non-circular, and contain off-centered Au-cores. Using the average NP dimensions determined from STEM analysis, SESSA spectral modeling indicated that washed Au/Ag-core shell NPs were stabilized with a 0.8 nm l

Core-shell nanoparticles↗

Exploring the Electrochemical Stability Window of an All-Solid-State Composite Cathode via a Novel Operando Tender XPS Setup

All-solid-state batteries (ASSBs) have the potential to provide greater energy density than conventional batteries based on liquid electrolytes. Here, an operando ASSB cell setup for tender X-ray photoelectron spectroscopy (XPS) was developed, and the interface of a Ni-rich layered transition metal oxide cathode active material (CAM) and an Li 6 PS 5 Cl (LPSCl) solid electrolyte (SE) was evaluated during initial charge/discharge cycles. After validating the cell performance against a conventional pouch cell operated at high compression, intermittent galvanostatic cycling was performed, and XPS data were recorded as a function of state of charge (SOC). Upon the initial charge of the cell to ≈3.3 V Li , the LPSCl appears to decompose into LiCl, Li 3 PS 4 , and polysulfides, whose amount gradually increases with potential. Upon further charge, at a potential higher than ≈3.8 V Li , initially, present sulfate and sulfite impurities decompose, and at ≈74% SOC (corresponding to a cathode potential of ≈4.10 V Li ), surface reconstruction of the CAM particles due to lattice oxygen release is detected. In addition, at potentials beyond ≈4.6 V Li , a decrease of the S 1s counts of the sum of the LPSCl, the thiophosphate, and polysulfide species suggests the formation of elemental sulfur that is lost via sublimation into the vacuum chamber.

25 ENERGY STORAGE↗

Structural model of homogeneous As–S glasses derived from Raman spectroscopy and high-resolution XPS

The structure of homogeneous bulk As x S 100- x (25 ≤ x ≤ 42) glasses, prepared by the conventional rocking–melting–quenching method, was investigated using high-resolution X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. It is shown that the main building blocks of their glass networks are regular AsS 3/2 pyramids and sulfur chains. In the S-rich domain, the existence of quasi-tetrahedral (QT) S = As(S 1/2 ) 3 units is deduced from XPS data, but with a concentration not exceeding ~3–5% of total atomic sites. Therefore, QT units do not appear as primary building blocks of the glass backbone in these materials, and an optimally-constrained network may not be an appropriate description for glasses when x < 40. Finally, it is shown that, in contrast to Se-based glasses, the ‘chain-crossing’ model is only partially applicable to sulfide glasses.

36 MATERIALS SCIENCE↗

XPS analysis of molecular contamination and sp 2 amorphous carbon on oxidized (100) diamond

The efficacy of oxygen (O) surface terminations on diamond is an important factor for the performance and stability for diamond-based quantum sensors and electronics. Given the wide breadth of O-termination techniques, it can be difficult to discern which method would yield the highest and most consistent O coverage. Furthermore, the interpretation of surface characterization techniques is complicated by surface morphology and purity, which if not accounted for will yield inconsistent determination of the oxygen coverage. We present a comprehensive approach to consistently prepare and analyze oxygen termination of surfaces on (100) single-crystalline diamond. We report on x-ray photoelectron spectroscopy (XPS) characterization of diamond surfaces treated with six oxidation methods that include various wet chemical oxidation techniques, photochemical oxidation with UV illumination, and steam oxidation using atomic layer deposition (ALD). Our analysis entails a rigorous XPS peak-fitting procedure for measuring the functionalization of O-terminated diamond. The findings herein have provided molecular-level insights on oxidized surfaces in (100) diamond, including the demonstration of clear correlation between the measured oxygen atomic percentage and the presence of molecular contaminants containing nitrogen, silicon, and sulfur. We also provide a comparison of the sp 2 carbon content with the O1s atomic percentage and discern a correlation with the diamond samples treated with dry oxidation which eventually tapers off at a max O1s atomic percentage value of 7.09 ± 0.40%. Given these results, we conclude that the dry oxidation methods yield some of the highest oxygen amounts, with the ALD water vapor technique proving to be the cleanest technique out of all the oxidation methods explored in this work.

XPS↗

XPS Determination of Uranium Oxidations States

This contribution is both a review of different aspects of the XPS spectra that can help one determine U oxidation states and a personal perspective on how to effectively model the XPS of complicated mixed valence U phases. After a discussion of the valence band, the focus lingers on the U4f region, where the use of binding energies, satellite structures, and peak shapes is discussed in some detail. Binding energies were shown to be very dependent on composition/structure and consequently unreliable guides to oxidation state, particularly where assignment of composition is difficult. Likewise, the spin orbit split 4f7/2 and 4f5/2 peak shapes do not carry significant information on oxidation states. In contrast, both satellite-primary peak binding energy separations, as well as intensities too lesser extent, are relatively insensitive to composition/structure within the oxide-hydroxide-hydrate system and can be used to both identify and help quantify U oxidation states in mixed valence phases. An example of the usefulness of the satellite structure in constraining the interpretation of a complex multivalence U compound is given.

54 ENVIRONMENTAL SCIENCES↗

XPS characterization of polymer–monocalcium aluminate interface

The aim of this paper is the introduction of a sophisticated testing method, X-ray photoelectron spectroscopy (XPS), used to study the interface between the hydrated cement phase and polymer after mechanochemical activation, which is fundamental for the creation of macro-defect-free (MDF) composites. The XPS results clearly explain the hypothesis of a chemical reaction mechanism in the interphase regions affecting the final properties of the MDF materials.

36 MATERIALS SCIENCE↗