At least 91 records · Page 5

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Residual Stress Analysis of Overspeeded Disk with Central Hole by X-ray Diffraction

An X-ray - diffraction analysis of residual surface stresses after plastic strain was introduced in a parallel-sided 3S-O aluminum disk with a central hole by two types of centrifugal overspeed is reported. Both tangential and radial stresses were generally tensile with large local variations near the hole where surface stresses may have been partly superficial. These stresses were both tensile and compressive dependent on the distance from the disk center when mass compression was effected near the hole.

ALUMINUM↗

Apollo 15 orbital science summary.

In this paper, summary results of the Apollo 15 orbital science payload are given, and some quick-look results of Apollo 16 are discussed. Geochemical instruments, consisting of gamma-ray, X-ray, and alpha particle spectrometers, have provided a chemical map of the lunar surface flown over by Apollo 15. The Laser Altimeter and frontside gravity data have shown some unexpected results with regard to the lunar shape, and provided new basis for understanding lunar mascons. A magnetometer, aboard the small subsatellite, has located magnetic anomalies principally on the lunar farside, and has shown that the small lunar magnetic field is smoother on the frontside than on the back. The mass spectrometer, in orbit aboard the Command and Service Modules, has measured unexpectedly large populations of molecules at orbital altitude (110 km), mostly due to spacecraft contamination. Two major camera systems have provided the first systematic metric quality photography and concurrent high resolution stereo coverage of the lunar surface.

Esenwein, G. F.↗

Progress in Development of Methods in Bone Densitometry

The effects of weightlessness and decreased activity on the astronaut's musculoskeletal system during prolonged space flight, missions are of concern to NASA. This problem was anticipated from the knowledge that human subjects lose significant quantities of calcium from the skeleton during periods of bedrest, immobilization, and water immersion. An accurate method of measurement of the changes in mineral content of the skeleton is required not only in the space program but also in the biological, medical, and dental fields for mineral metabolism studies and for studying various pathological conditions of the skeleton and teeth. This method is a difficult one requiring the coordinated efforts of physiologists, biophysicists, radiologists, and clinicians. The densitometry methods reported in this conference which have been used or are being developed include X-ray, beta excited X-rays, radioisotopes, sonic vibration, and neutron activation analysis Studies in the Gemini, Biosatellite, and Apollo flights use the X-ray bone densitometry method which requires making X-rays before and after the flights. An in-flight method of bone densitometry would be valuable, and use of radioisotope sources has been suggested. Many advances in bone densitometry have been made in the last five years, and the urgency of the requirement makes this working conference timely and valuable. In such a rapidly developing field with investigators working independently in a variety of scientific disciplines, a working conference is of great value in exchanging information and ideas, critically evaluating approaches and methods, and pointing out new research pathways.

DENSITOMETER↗

Report of astronomy study group

Experiments on earth and moon dealing with radio, optical, X-ray and gamma ray astronomy based on Lunar Exploration System for Apollo /LESA/ REPORT

RADIO ASTRONOMY↗

A discussion of the H-alpha filamentary nebulae and galactic structure in the Cygnus region

From observation of the galactic structure in Cygnus, the system of filamentary nebulae was found to lie at a distance of roughly 1.5 kpc, in the same region as about half the thermal radio sources in Cygnus X, the supernova remnant near gamma Cygni, and the association Cygnus OB2, in the direction of which the X-ray source Cygnus XR-3 is observed. The source of excitation was probably the pulse of radiation from a supernova explosion, as proposed in the case of Gum nebula. However continuing excitation by early stars in the region of Cygnus X cannot be excluded.

Matthews, T. A.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

Glancing incidence optics for X-ray and ultraviolet astronomy.

Glancing incidence telescopes of the kind first described by Wolter have now been physically realized, so that it is possible to obtain high-resolution images of celestial objects at all wavelengths greater than about 3 A. The GSFC-MSFC X-ray telescope for the Apollo telescope mount uses Wolter type 1 optics and is capable of forming images of the sun in the 8-70 A region with spatial resolution of the order of one arc second. The GSFC extreme ultraviolet spectroheliometer for OSO H uses type 2 optics and can obtain images of the sun in spectral lines in the 170-400 A region with a spatial resolution of about ten arc seconds. Theoretical (ray trace) and laboratory data on these systems are presented.

Underwood, J. H.↗