Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantifying uncertainty in analysis of shockless dynamic compression experiments on platinum. I. Inverse Lagrangian analysis

Absolute measurements of solid-material compressibility by magnetically driven shockless dynamic compression experiments to multi-megabar pressures have the potential to greatly improve the accuracy and precision of pressure calibration standards for use in diamond anvil cell experiments. Here, to this end, we apply characteristics-based inverse Lagrangian analysis (ILA) to 11 sets of ramp-compression data on pure platinum (Pt) metal and then reduce the resulting weighted-mean stress–strain curve to the principal isentrope and room-temperature isotherm using simple models for yield stress and Grüneisen parameter. We introduce several improvements to methods for ILA and quasi-isentrope reduction, the latter including calculation of corrections in wave speed instead of stress and pressure to render results largely independent of initial yield stress while enforcing thermodynamic consistency near zero pressure. More importantly, we quantify in detail the propagation of experimental uncertainty through ILA and model uncertainty through quasi-isentrope reduction, considering all potential sources of error except the electrode and window material models used in ILA. Compared to previous approaches, we find larger uncertainty in longitudinal stress. Monte Carlo analysis demonstrates that uncertainty in the yield-stress model constitutes by far the largest contribution to uncertainty in quasi-isentrope reduction corrections. We present a new room-temperature isotherm for Pt up to 444 GPa, with 1-sigma uncertainty at that pressure of just under ±1.2%; the latter is about a factor of three smaller than uncertainty previously reported for multi-megabar ramp-compression experiments on Pt. The result is well represented by a Vinet-form compression curve with (isothermal) bulk modulus K 0 = 270.3 ± 3.8 GPa, pressure derivative K$^{'}_{0}$= 5.66 ± 0.10, and correlation coefficient $R_{K_{0},K^{'}_{0}}$= –0.843.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock-Induced Optical Changes in AI 2 O 3 at 200 GPa; Implications for Shock Temperature Measurements in Metals [Book Chapter]

A knowledge of the optical property of window materials at shock pressures above 100 GPa is crucial for determining shock temperatures in metals. We have examined the optical properties of Al 2 O 3 at 200-300 GPa pressures using a time-resolved optical method. The strong emission and the partial opacity are observed from the shocked Al 2 O 3 . Wavelength- and time-dependence of the emission will be presented. A new electro-optical technique facilitating time-resolved optical measurements at a 2-stage light gas gun will be described.

36 MATERIALS SCIENCE↗

Electronic, elastic, and optical properties of monolayer BC{sub 2}N

The structural stability, electronic structure, elasticity, and optical properties of four types of monolayer BC{sub 2}N have been investigated from first principles using calculation based on density functional theory. The results show that the structural stability of BC{sub 2}N increases with the number of C–C and B–N bonds. By calculating the two-dimensional Young's modulus, shear modulus, Poisson's ratio, and shear anisotropic factors in different directions, four structures present various anisotropies and the most stable structure is almost isotropic. For C-type BC{sub 2}N, the values of two-dimensional Young's modulus, shear modulus, and bulk modulus (309, 128, 195 GPa m{sup −1}), are smaller than those of graphene (343, 151, 208) but bigger than those of h-BN (286, 185, 116). Furthermore, the dielectric function, refractive index, reflectivity, absorption coefficient, and energy loss spectrum are also calculated to investigate the mechanism underpinning the optical transitions in BC{sub 2}N, revealing monolayer BC{sub 2}N as a candidate window material. - Graphical abstract: Schematic diagram of BC{sub 2}N under the biaxial tensile strain. Changes in the valence-band top and the conduction-band bottom of BC{sub 2}N with increasing strain.

36 MATERIALS SCIENCE↗

Enhanced UV light detection using a p-terphenyl wavelength shifter

Here, UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below $300\,\text{nm}$. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between $200\,\text{nm}$ and $400\,\text{nm}$. The gain factor ranges up to 5.4 $\pm$ 0.5 at a wavelength of $215\,\text{nm}$, with a material load of $110\pm10\,\mu\text{g}/\text{cm}^2$ ($894\,\text{nm}$). The wavelength shifter was found to be fully transparent for wavelengths greater than $300\,\text{nm}$. The resulting gain in detection efficiency, when used in a typical Cherenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold Cherenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the refractive index of shocked [100] lithium fluoride to the limit of transmissibility

Lithium fluoride (LiF) is a common window material used in shock- and ramp-compression experiments because it displays a host of positive attributes in these applications. Most commonly, it is used to maintain stress at an interface and velocimetry techniques are used to record the particle velocity at that interface. In this application, LiF remains transparent to stresses up to 200 GPa. In this stress range, LiF has an elastic-plastic response with a very low (<0.5 GPa) elastic precursor and exhibits no known solid-solid phase transformations. However, because the density dependence of the refractive index of LiF does not follow the Gladstone-Dale relation, the measured particle velocity at this interface is not the true particle velocity and must be corrected. For that reason, the measured velocity is often referred to as the apparent velocity in these types of experiments. In this article, we describe a series of shock-compression experiments that have been performed to determine the refractive index of LiF at the two most commonly used wavelengths (532 nm and 1550 nm) between 35 and 200 GPa to high precision. A modified form of the Gladstone-Dale relation was found to work best to fit the determined values of refractive index. In addition, we provide a direct relationship between the apparent and true particle velocity to correct experimentally obtained wave profiles by others using these velocimetry techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cross-Propagation Sum-Frequency Generation Vibrational Spectroscopy

Here we report the theory formulation and the experiment realization of sum-frequency generation vibrational spectroscopy (SFG-VS) in the cross-propagation (XP) geometry or configuration. In the XP geometry, the visible and the infrared (IR) beams in the SFG experiment are delivered to the same location on the surface from visible and IR incident planes perpendicular to each other, avoiding the requirement to have windows or optics to be transparent to both the visible and IR frequencies. Therefore, the XP geometry is applicable to study surfaces in the enclosed vacuum or high pressure chambers with far infrared (FIR) frequencies that can directly access the metal oxide and other lower frequency surface modes, with much broader selection of visible and IR transparent window materials.

Co-propagation↗

Shock-induced melting of [100] lithium fluoride: Sound speed and Hugoniot measurements to 230 GPa

Although [100] lithium flouride (LiF) is the most widely used optical window material in dynamic compression experiments, its high stress (>100 GPa) shock compression response, including melting, is not well understood. To address this need, we measured wave profiles in plate impact experiments to determine the Hugoniot states and longitudinal sound speeds in [100] LiF crystals shock compressed to 231 GPa. The measured peak states are fitted well by a linear shock velocity-particle velocity relation, providing an accurate determination of the LiF Hugoniot curve to significantly higher stresses than previous experiments. The longitudinal sound speeds show a near linear increase with density compression to 182 GPa. Between 182 GPa and 195 GPa, the sound speed and the longitudinal modulus decrease abruptly, due to shock-induced melting. The increasing sound speeds and moduli at higher stresses suggest that shock compressed LiF is fully liquid at 195 GPa and above, allowing determination of the Gruneisen parameter for liquid LiF. Here, the melt stress determined here differs from that predicted by current multiphase equations of state for LiF. Our results provide important insight into the high stress solid and liquid states of shock compressed LiF and point to the need for an improved multiphase equation of state at high pressures and high temperatures.

36 MATERIALS SCIENCE↗

Ab initiomany-body Green's function calculations of optical properties of LiF at high pressures

We present density functional theory (DFT) + quasiparticle self-energy (G 0 W 0 )+ Bethe-Salpeter calculations of the real and imaginary parts of the long-wavelength dielectric function of LiF between ambient pressure and P=5 Mbars. While the optical absorption spectrum is predicted to show dramatic pressure-dependent features above the optical gap, the index of refraction well below the gap is shown to exhibit the same trends as that seen in both DFT calculations and experiment: a roughly linear increase with density. This increase does not result from a decrease in the band gap, but rather follows from the increase in oscillator strength which counteracts a smaller increase in band gap with P. Our calculations also suggest that the index of refraction (for visible and near-UV light) of the higher-T B 2 phase should be quite close to that of the B 1 (ambient crystalline) phase. These findings may be of interest to researchers who use LiF as a window material in dynamic compression experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers

The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of multipixel photon counters from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at the Brookhaven National Laboratory and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10 8 to 10 12 n/cm 2 . The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This paper was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Characterization of the ionization chamber for the SPIDER detector

We request 3 days of ATLAS beams for testing the ionization chamber component of the SPIDER detector, a spectrometer for mea suring the mass yields of neutron-induced fission fragments. The ion ization chamber will be a stand alone detector to be coupled to the end of the beam pipe at zero degrees. These tests are a mass and energy specific characterization of the ionization chamber operating conditions specific to SPIDER, including entrance window material options. Once tested, the results will be applied to the energy cal ibration process of SPIDER, a crucial step to achieving high mass resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of High-Entropy Alloys for Accelerator Beam Window Applications

Particle production targets and accelerator beam windows receive millions of high-energy/intensity beam pulses throughout their service lifetime. For next-generation multi-MW accelerators, it is necessary for beam windows to be able to withstand higher levels of thermal shock and radiation damage, while also having good high-temperature mechanical properties. Novel High-Entropy Alloys (HEAs) that form a single-phase microstructure, have nanoscale precipitates, and are made from low-Z elements are good candidates for beam window materials. This is due to their high-temperature strength and high resistance to radiation-induced swelling and hardening, as well as their beam transparency, allowing for maximized particle production and a longer service lifetime.

Kidwell, Tristan [U. Chicago (main)] (ORCID:000900↗

Improved transmittance measurement with a magnesium oxide coated integrating sphere

Simple and convenient technique has been found for extending transmittance measurement capability of conventional magnesium oxide coated integrating sphere system at low (near ultraviolet) wavelengths. Technique can be used to determine effect of contaminants on window materials and can also be used for measurements on thermal control coatings and telescope mirrors.

Bowman, R. L.↗

Optical polarimetry: Instrumentation and applications; Proceedings of the Seminar, San Diego, Calif., August 23, 24, 1977

Instrumentation used in optical polarimetry is discussed with reference to high-resolution spectropolarimetry, an orbiter cloud photopolarimeter, X-ray polarimeters, and the design of a self-nulling ellipsometer. Consideration is given to surface and thin-film ellipsometry noting studies of electrochemical surface layers, surface anisotropy, polish layers on infrared window materials, and anodic films. Papers on biological, chemical, and physical polarimetry are presented including birefringence in biological materials, vibrational optical activity, and the optical determination of the thermodynamic phase diagram of a metamagnet. Remote sensing is discussed in terms of polarization imagery, the optical polarimetry of particulate surfaces, and techniques and applications of elliptical polarimetry in astronomy and atmospheric studies.

Azzam, R. M. A.↗

Radiation studies of optical and electronic components used in astronomical satellite studies

The synchronous orbit of the IUE carries the satellite through Earth's outer electron belt. A 40 mCi Sr90 source was used to simulate these electrons. A 5 mCi source of Co60 was used to simulate bremmstrahlung. A 10 MeV electron Linac and a 1.7 MeV electron Van de Graaf wer used to investigate the energy dependence of radiation effects and to perform radiations at a high flux rate. A 100 MeV proton cyclotron was used to simulate cosmic rays. Results are presented for three instrument systems of the IUE and measurements for specific components are reported. The three instrument systems were the ultraviolet converter, the fine error sensor (FES), and the SEC vidicon camera tube. The components were optical glasses, electronic components, silicon photodiodes, and UV window materials.

Becher, J.↗

Flow visualization in the Langley 0.3-meter Transonic Cryogenic Tunnel and preliminary plans for the National Transonic Facility

Design problems associated with the integration of flow visualization in cryogenic facilities are discussed. The possible effects from the cryogenic environment (i.e., window distortion due to thermal contraction both in the mounts and in the window material itself and turbulence in the flow due to injected LN2) are examined. The flow visualization techniques studied are schlieren, shadowgraph, moire deflectometry, and holographic interferometry. The test beds for this work are a Langley in-house cryogenic test chamber and the 0.3-Meter Transonic Cryogenic Tunnel.

Rhodes, D. B.↗

Intensified-CCD focal plane detector for space applications A second generation

An intensified-CCD detector system developed for space applications from commercially available components is described. This detector uses components which are readily available and are mechanically, thermally, and optically coupled to produce the final compact system. The CCD is cooled using a Peltier-effect thermoelectric cooler to reduce thermal noise. The image is formed on the photocathode of a proximity-focused image intensifier and is transferred fiber-optically from the intensifier to the CDD. Various photocathode and window materials are used to optimize the system for use within the wavelength range extending from the far UV to the near IR. The basic design, including the image intensifier, intensifier-CCD interface, CCD array, cooling, electronics, and mounting, and the detector performance are described in detail.

Torr, M. R.↗