Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIND TUNNELS - OPEN THROAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Aerodynamic characteristics of a large-scale semispan model with a swept wing and an augmented jet flap with hypermixing nozzles

The aerodynamic characteristics of the augmentor wing concept with hypermixing primary nozzles were investigated. A large-scale semispan model in the Ames 40- by 80-Foot Wind Tunnel and Static Test Facility was used. The trailing edge, augmentor flap system occupied 65% of the span and consisted of two fixed pivot flaps. The nozzle system consisted of hypermixing, lobe primary nozzles, and BLC slot nozzles at the forward inlet, both sides and ends of the throat, and at the aft flap. The entire wing leading edge was fitted with a 10% chord slat and a blowing slot. Outboard of the flap was a blown aileron. The model was tested statically and at forward speed. Primary parameters and their ranges included angle of attack from -12 to 32 degrees, flap angles of 20, 30, 45, 60 and 70 degrees, and deflection and diffuser area ratios from 1.16 to 2.22. Thrust coefficients ranged from 0 to 2.73, while nozzle pressure ratios varied from 1.0 to 2.34. Reynolds number per foot varied from 0 to 1.4 million. Analysis of the data indicated a maximum static, gross augmentation of 1.53 at a flap angle of 45 degrees. Analysis also indicated that the configuration was an efficient powered lift device and that the net thrust was comparable with augmentor wings of similar static performance. Performance at forward speed was best at a diffuser area ratio of 1.37.

Aiken, T. N.↗

Computation of nonequilibrium viscous flows in arc-jet wind tunnel nozzles

The axisymmetric Navier-Stokes equations are numerically solved for air flows in converging-diverging conical nozzles. A nonequilibrium formulation with a two-temperature thermochemical model has been employed for vibrationally excited, partially dissociated and ionized air. Evaluations of the formulation is made through comparisons of the computed flow quantities with the experimental data obtained in expanding arc-jet nozzle flows. Two sets of experimental data obtained in conical nozzles with geometric exit-to-throat area ratios of 625 and 8100 cover reservoir pressures ranging from 5 to 95 atm and enthalpies from 5 to 10 MJ/kg. The computed results are in good agreement with local mass flux, Pitot pressure, and static wall pressure measurements at the nozzle exit. For low pressure reservoir conditions, comparisons of computations with the experimental data indicate that the wall catalycity is very important in predicting species mole fraction at the nozzle exit since gas phase chemistry is frozen. The current computations overpredict the atomic oxygen concentrations which in turn results in underprediction of the vibrational temperature.

Gokcen, Tahir↗

Fluid flow analysis of a hot-core hypersonic wind-tunnel nozzle concept

A hypersonic-wind-tunnel nozzle concept which incorporates a hot-core flow surrounded by an annular flow of cold air offers a promising technique for maximizing the model size while minimizing the power required to heat the test core. This capability becomes especially important when providing the true-temperature duplication needed for hypersonic propulsion testing. Several two-dimensional wind-tunnel nozzle configurations that are designed according to this concept are analyzed by using recently developed analytical techniques for prediction of the boundary-layer growth and the mixing between the hot and cold coaxial supersonic airflows. The analyses indicate that introduction of the cold annular flow near the throat results in an unacceptable test core for the nozzle size and stagnation conditions considered because of both mixing and condensation effects. Use of a half-nozzle with a ramp on the flat portion does not appear promising because of the thick boundary layer associated with the extra length. However, the analyses indicate that if the cold annular flow is introduced at the exit of a full two-dimensional nozzle, an acceptable test core will be produced. Predictions of the mixing between the hot and cold supersonic streams for this configuration show that mixing effects from the cold flow do not appreciably penetrate into the hot core for the large downstream distances of interest.

Anders, J. B.↗

Investigation of Net-Thrust and Base-Pressure Characteristics of Cylindrical Afterbodies with Clustered Supersonic Nozzles at Transonic Mach Numbers

A wind-tunnel investigation has been conducted at Mach numbers from 0.9 to 1.4 to determine the net-thrust and base-pressure characteristics of cylindrical afterbodies having clustered supersonic nozzles. The design Mach numbers of the nozzles were 2.0 and 2.5 and the number of clustered nozzles ranged from two to six. The nozzles had throat-to- base diameter ratios of 0.155, 0.225, 0.278, and 0.320. Some models were tested with various configurations of extended, shrouded, flush, and canted nozzles. The nozzles discharged unheated air from the base at ratios of jet total pressure to free-stream static pressure ranging from 1 to approximately 20. The results of this investigation showed that both the ratio of total exit area to base area and the number of jets affect the net-thrust factor to a significant degree for the extended-nozzle configurations. Good net-thrust factors were obtained with all the model configurations near the design jet total-pressure ratio; however, the extended-nozzle configuration had the highest net-thrust factor over the test jet total- pressure-ratio range. Canting the twin nozzles outward resulted in a favorable thrust factor over a limited jet total-pressure-ratio range, and surrounding the nozzles with a single shroud reduced thrust factors for the range of jet total-pressure ratio of this investigation.

Andrews, Earl H., Jr.↗

Wind tunnel investigation of three axisymmetric cowls of different lengths at Mach numbers from 0.60 to 0.92

Pressure distributions on three inlets having different cowl lengths were obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (highlight diameter to maximum diameter) was 0.85 and the cowl length ratios (cowl length to maximum diameter) were 0.337, 0.439, and 0.547. The cowls had identical nondimensionalized (with respect to cowl length) external geometry and identical internal geometry. The internal contraction ratio (highlight area to throat area) was 1.250. The inlets had longitudinal rows of static pressure orifices on the top and bottom (external) surfaces and on the contraction (internal) and diffuser surfaces. The afterbody was cylindrical in shape, and its diameter was equal to the maximum diameter of the cowl. Depending on the cowl configuration and free-stream Mach number, the mass-flow ratio varied between 0.27 and 0.87 during the tests. Angle of attack varied from 0 to 4.1 deg at selected Mach numbers and mass-flow ratios, and the Reynolds number varied with the Mach number from 3.2x10(exp 6) to 4.2x10(exp 6) per foot.

Re, Richard J.↗

Analysis of results from wind tunnel tests of inlets for an advanced turboprop nacelle installation

Inlets for tractor installations of advanced turboprop propulsion systems were tested in three phases, covering a period from November, 1982 to January, 1984. Nacelle inlet configuration types included single scoop, twin scoop, and annular arrangements. Tests were performed with and without boundary layer diverters and several different diverter heights were tested for the single scoop inlet. This same inlet was also tested at two different axial positions. Test Mach numbers ranged from Mach 0.20 to 0.80. Types of data taken were: (1) internal and external pressures, including inlet throat recoveries; (2) balance forces, including thrust-minus-drag; and (3) propellar blade stresses.

Hancock, J. P.↗

Flow separation in inlets at incidence angles

Wind-tunnel pressure data and flow pictures obtained for two two-dimensional inlet models have been examined to study the internal flow structure and separation at large incidence angles. The inlet models were 12-in. high (diffuser exit height) and had internal contraction ratio of 1.21 and 1.17. They were tested at low forward speeds over a wide range of throat Mach numbers (inlet mass flow rates) and angles of incidence. Characteristic features of the internal flow such as a drastic change of pressure gradient near the highlight, local separation bubbles and shock/boundary-layer interactions have been indicated and discussed. For a few specific cases, the experimental surface pressure distributions have been compared with theoretical predictions.

Jakubowski, A. K.↗

Investigation of a mixed compression axisymmetric inlet at Mach number 5.3

The hypersonic diffuser portion of an uncooled high performance mixed compression, axisymmetric inlet suitable for subsonic burning engines was designed and tested. Performance of a model with a 25.4-cm capture diameter was measured in a wind tunnel and the results were compared with theoretical predictions calculated by a comprehensive computer program. All tests were conducted at a Mach number of 5.3 at a total temperature of 667 K and a total pressure of 11.57 atm. The angle of attack ranged from 0 to + or - 3 deg. Performance at angle of attack remained high. Reasonably high performance in the throat (maximum throat pitot-pressure recovery of 77 percent and an average value of 58 percent) was obtained at 0 deg angle of attack with relatively large amounts of boundary-layer bleed (11 to 22 percent of the capture mass flow). The computer program used in the design of this inlet is considered marginally adequate for predicting hypersonic inlet flow fields. Although the program as it now exists is very useful, an improved computer program that more accurately predicts the boundary layer and the shock-wave-boundary-layer interaction and accounts for boundary-layer bleed should be developed for reliability predicting hypersonic inlet flow fields.

Latham, E. A.↗

Wind-tunnel tests on a 3-dimensional fixed-geometry scramjet inlet at M = 2.30 to 4.60

Wind-tunnel tests were conducted on a baseline scramjet inlet model having fixed geometry and swept leading edges at M = 2.30, 2.96, 3.95, and 4.60 in the Langley unitary plan wind tunnel. The unit Reynolds number of the tests was held constant at 6.56 million per meter (2 million per foot). The objectives of the tests were to establish inlet performance and starting characteristics in the lower Mach number range of operation (less than M = 5). Surface pressures obtained on the inlet components are presented, along with the results of the internal flow surveys made at the throat and capture stations of the inlet. Contour plots of the inlet-flow-field parameters such as Mach numbers, pressure recovery, flow capture, local static and total pressure ratios at the survey stations are shown for the test Mach numbers.

Mueller, J. N.↗

Airflow calibration of a bellmouth inlet for measurement of compressor airflow in turbine-powered propulsion simulators

The development of turbine-powered propulsion simulators for high-speed wind tunnel models requires a bellmouth inlet which can accurately measure compressor-inlet airflow. A bellmouth inlet was instrumented with total pressure probes, static pressure probes, and thermocouples for airflow measurement. The bellmouth flowmeter against a critical venturi flowmeter was calibrated. The calibration was done at four inlet pressures ranging from 58 to 114 kPa. The bellmouth discharge coefficient varied as a function of bellmouth-throat Mach number. Over the range of Reynolds number and Mach number tested the Reynolds number was not a significant influence on the discharge coefficient. The overall accuracy of the bellmouth inlet as a flowmeter was estimated to be + or - 0.5% of the flowmeter reading.

Smith, S. C.↗

Flow in a discrete slotted nozzle with massive injection

An experimental investigation has been conducted to determine the effect of massive wall injection on the flow characteristics in a slotted nozzle. Some of the experiments were performed on a water table with a slotted-nozzle test section. This has 45 deg and 15 deg half angles of convergence and divergence, respectively, throat radius of 2.5 inches, and throat width of 3 inches. The hydraulic analogy was employed to qualitatively extend the results to a compressible gas flow through the nozzle. Experimental results from the water table include contours of constant Froude and Mach number with and without injection. Photographic results are also presented for the injection through slots of CO2 and Freon-12 into a main-stream air flow in a convergent-divergent nozzle in a wind tunnel. Schlieren photographs were used to visualize the flow, and qualititative agreement between the results from the gas tunnel and water table is good.

Perkins, H. C.↗

Computer analysis of flow perturbations generated by placement of choke bumps in a wind tunnel

An inviscid analytical study was conducted to determine the upstream flow perturbations caused by placing choke bumps in a wind tunnel. A computer program based on the stream-tube curvature method was used to calculate the resulting flow fields for a nominal free-stream Mach number range of 0.6 to 0.9. The choke bump geometry was also varied to investigate the effect of bump shape on the disturbance produced. Results from the study indicate that a region of significant variation from the free-stream conditions exists upstream of the throat of the tunnel. The extent of the disturbance region was, as a rule, dependent on Mach number and the geometry of the choke bump. In general, the upstream disturbance distance decreased for increasing nominal free-stream Mach number and for decreasing length-to-height ratio of the bump. A polynomial-curve choke bump usually produced less of a disturbance than did a circular-arc bump and going to an axisymmetric configuration (modeling choke bumps on all the tunnel walls) generally resulted in a lower disturbance than with the corresponding two dimensional case.

Campbell, R. L.↗

A Wind Tunnel Investigation of Three NACA 1-Series Inlets at Mach Numbers up to 0.92

Pressure distributions on three NACA 1-series inlets have been obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (ratio of cowl highlight diameter to cowl maximum diameter) was 0.85 for all three inlets. The cowl length ratio (ratio of cowl length to cowl maximum diameter) was 1.0 for two of the inlets (NACA 1-85-100) and 0.439 for the other (NACA 1-85-43.9) inlet. One of the inlets with a cowl length ratio of 1.0 had an internal contraction ratio (ratio of highlight area to throat area) of 1.009 and the other had a contraction ratio of 1.250. The inlet with a cowl length ratio of 0.439 also had an internal contraction ratio of 1.250. All three inlets had longitudinal rows of static pressure orifices on the top and bottom external cowl surfaces. The inlet with a contraction ratio of 1.009 also had a row of static pressure orifices on the side of the cowl (external surface). The two inlets with a contraction ratio of 1.250 had a longitudinal row of static pressure orifices on the diffuser surface.

Re, Richard J.↗

Fluctuating disturbances in a Mach 5 wind tunnel

An experimental investigation has been conducted to determine the source and nature of disturbances in the settling chamber and test section of a Mach 5 wind tunnel. Various changes in the air supply piping to the wind tunnel are shown to influence the disturbance levels in the settling chamber. These levels were reduced by the use of an acoustic muffler section in the settling chamber. Three nozzles were tested with the same settling chamber and hot-wire measurements indicated that the test section disturbances were entirely acoustic. Significant reductions in the test section noise levels were obtained with an electroplated nozzle utilizing boundary-layer removal upstream of the throat. The source of test section noise is shown to be different for laminar and turbulent nozzle-wall boundary layers.

Anders, J. B.↗

Static performance of vectoring/reversing non-axisymmetric nozzles

An experimental program sponsored by the Air Force Flight Dynamics Laboratory is currently in progress to determine the internal and installed performance characteristics of five different thrust vectoring/reversing non-axisymmetric nozzle concepts for tactical fighter aircraft applications. Internal performance characteristics for the five non-axisymmetric nozzles and an advanced technology axisymmetric baseline nozzle were determined in static tests conducted in January 1977 at the NASA-Langley Research Center. The non-axisymmetric nozzle models were tested at thrust deflection angles of up to 30 degrees from horizontal at throat areas associated with both dry and afterburning power. In addition, dry power reverse thrust geometries were tested for three of the concepts. The best designs demonstrated internal performance levels essentially equivalent to the baseline axisymmetric nozzle at unvectored conditions. The best designs also gave minimum performance losses due to vectoring, and reverse thrust levels up to 50% of maximum dry power forward thrust. The installed performance characteristics will be established based on wind tunnel testing to be conducted at Arnold Engineering Development Center in the fall of 1977.

Willard, C. M.↗

Incidence angle bounds for lip flow separation of three 13.97-centimeter-diameter inlets

Low speed wind tunnel tests were conducted to establish a procedure for determining inlet-lip flow separation and to make preliminary examination of the incidence angle bounds for lip flow separation on inlets intended for the nacelles of STOL (short takeoff and landing) aircraft. Three inlets were tested. Two of the inlets had short centerbodies with lower lip area contraction ratios of 1.30 and 1.44. The third inlet had a cylindrical centerbody extended forward into the inlet throat with a lower lip area contraction ratio of 1.44. The inlets were sized to fit a 13.97 centimeter-diameter fan. For inlet throat Mach numbers less than about 0.43, the lip flow separation angle was increased by either increasing the ratio of throat velocity to freestream velocity (Vt/Vo) or by increasing the lower lip area contraction ratio. For throat Mach numbers greater than a certain value (ranging from 0.43 to 0.52), increasing throat Mach number in some cases resulted in a decrease in the lip flow separation angle. Extending a cylindrical centerbody into the inlet throat increased the flow separation angle for nearly all values of Vt/Vo.

Luidens, R. W.↗

Isolated testing of highly maneuverable inlet con cepts

Ten percent scale models of a Mach 2.2 two dimensional inlet and a Mach 2.0 axisymmetric inlet were tested in the NASA Lewis Research Center 8'x6' Supersonic Wind Tunnel as part of a cooperative effort with the McDonnell Aircraft Company. The objective of this effort was to test methods designed to increase the maneuvering performance of fighter aircraft inlets. Maneuvering improvement concepts were tested up to 40-deg angle of attack for Mach numbers of 0.6 and 0.9, and up to 25 deg for Mach numbers 1.2 and 1.4. Maneuvering improvement concepts included a rotating cowl lip, auxiliary inlets aft of the inlet throat, and a retracting centerbody for the axisymmetric inlet. Test results show that the rotating cowl design was effective in improving subsonic maneuvering performance for both inlets. Auxiliary inlets did not produce significant performance increases for either model. The retracted centerbody resulted in some performance benefits at high angles of attack. None of the maneuvering improvement concepts were effective at Mach 1.2 and 1.4.

Norby, W. P.↗

Performance of the high speed anechoic wind tunnel at Lyon University

The characteristics of the feed duct, the wind tunnel, and the experiments run in the convergent-divergent anechoic wind tunnel at Lyon University are described. The wind tunnel was designed to eliminate noise from the entrance of air or from flow interactions with the tunnel walls so that noise caused by the flow-test structure interactions can be studied. The channel contains 1 x 1 x 0.2 m glass and metal foil baffles spaced 0.2 m apart. The flow is forced by a 350 kW fan in the primary circuit, and a 110 kW blower in the secondary circuit. The primary circuit features a factor of four throat reductions, followed by a 1.6 reduction before the test section. Upstream and downstream sensors permit monitoring of the anechoic effectiveness of the channel. Other sensors allow modeling of the flow structures in the tunnel. The tunnel was used to examine turbulent boundary layers in flows up to 140 m/sec, tubulence-excited vibrations in walls, and the effects of laminar and turbulent flows on the appearance and locations of noise sources.

Sunyach, M.↗