Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WATER VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Water vapor profiling using microwave radiometry

Water vapor is one of the most important constituents in the Earth's atmosphere. Its spatial and temporal variations affect a wide spectrum of meteorological phenomena ranging from the formation of clouds to the development of severe storms. The passive microwave technique offers an excellent means for water vapor measurements. It can provide both day and night coverage under most cloud conditions. Two water vapor absorption features, at 22 and 183 GHz, were explored in the past years. The line strengths of these features differ by nearly two orders of magnitude. As a consequence, the techniques and the final products of water vapor measurements are also quite different. The research effort in the past few years was to improve and extend the retrieval algorithm to the measurements of water vapor profiles under cloudy conditions. In addition, the retrieval of total precipitable water using 183 GHz measurements, but in a manner analogous to the use of 22 GHz measurements, to increase measurement sensitivity for atmospheres of very low moisture content was also explored.

Wang, J. R.↗

Processes Controlling Water Vapor in the Winter Arctic Stratospheric Middleworld

Water vapor in the winter arctic stratospheric middleworld is import-an: for two reasons: (1) the arctic middleworld is a source of air for the upper Troposphere because of the generally downward motion, and thus its water vapor content helps determine upper tropospheric water, a critical part of the earth's radiation budget; and (2) under appropriate conditions, relative humidities will be large, even to the point of stratospheric cirrus cloud formation, leading to the production of active chlorine species that could destroy ozone. On a number of occasions during SOLVE, clouds were observed in the stratospheric middleworld by the DC-8 aircraft. These tended to coincide with regions of low temperatures, though some cases suggest water vapor enhancements due to troposphere-to-stratosphere transport. The goal of this work is to understand the importance of processes in and at the edge of the arctic stratospheric middleworld in determining water vapor at these levels. Specifically, is water vapor at these levels determined largely by the descent of air from above, or are clouds both within and at the edge of the stratospheric middleworld potentially important? How important is troposphere-to-stratosphere transport of air in determining stratospheric middleworld water vapor content? To this end, we will first examine the minimum saturation mixing ratios along theta/EPV tubes during the SOLVE winter and compare these with DC-8 water vapor observations. This will be a rough indicator of how high relative humidities can get, and the likelihood of cirrus cloud formation in various parts of the stratospheric middleworld. We will then examine saturation mixing ratios along both diabatic and adiabatic trajectories, comparing these values with actual aircraft water vapor observations, both in situ and remote. Finally, we will attempt to actually predict water vapor using minimum saturation mixing ratios along trajectories, cloud injection (derived from satellite imagery) along trajectories, and suitable initial conditions.

Pfister, Leonhard↗

Characterization of Upper Troposphere Water Vapor Measurements during AFWEX using LASE

Water vapor profiles from NASA's Lidar Atmospheric Sensing Experiment (LASE) system acquired during the ARM/FIRE Water Vapor Experiment (AFWEX) are used to characterize upper troposphere water vapor (UTWV) measured by ground-based Raman lidars, radiosondes, and in situ aircraft sensors. Initial comparisons showed the average Vaisala radiosonde measurements to be 5-15% drier than the average LASE, Raman lidar, and DC-8 in situ diode laser hygrometer measurements. We show that corrections to the Raman lidar and Vaisala measurements significantly reduce these differences. Precipitable water vapor (PWV) derived from the LASE water vapor profiles agrees within 3% on average with PWV derived from the ARM ground-based microwave radiometer (MWR). The agreement among the LASE, Raman lidar, and MWR measurements demonstrates how the LASE measurements can be used to characterize both profile and column water vapor measurements and that ARM Raman lidar, when calibrated using the MWR PWV, can provide accurate UTWV measurements.

Ferrare, R. A.↗

Method and apparatus for continuous removal of water vapors from gases

A method for continuously removing water vapor from a carrier gas is disclosed. This method includes, first, causing direct contact of the carrier gas with a liquid mixture in a separation chamber, the carrier gas condensing at a lower temperature than the water vapor. A combination of chemical effects cause the water vapor to condense, complex, or both condense and complex with the liquid mixture. The liquid mixture is chosen from the group consisting of: first, a combination of components that can be maintained in a liquid phase at a temperature below the water vapor's condensation point, whereby the water vapor condenses into the liquid mixture; second, a combination of components where at least one component forms a chemical complex with the water vapor and thereby extracts at least a portion of the water vapor from the carrier gas; and third, a combination of components that can both be maintained in a liquid phase at a temperature below the water vapor's condensation point, and wherein at least one component forms a chemical complex with the water vapor and thereby extracts at least a portion of the water vapor from the carrier gas. The liquid mixture is then reconstituted after passing through the separation chamber by a chemical separation process chosen to remove an equivalent amount of the water vapor from the liquid mixture as was removed from the carrier gas. The reconstituted liquid mixture is restored to temperature and pressure through heat exchange, compression, and expansion, as necessary, in preparation for recycling back to the separation chamber. The liquid mixture is then returned to the separation chamber. In this manner, the carrier gas leaving the exchanger has between 1% and 100% of the water vapor removed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A differential absorption technique to estimate atmospheric total water vapor amounts

Vertically integrated water-vapor amounts can be remotely determined by measuring the solar radiance reflected by the earth's surface with satellites or aircraft-based instruments. The technique is based on the method by Fowle (1912, 1913) and utilizes the 0.940-micron water-vapor band to retrieve total-water-vapor data that is independent of surface reflectance properties and other atmospheric constituents. A channel combination is proposed to provide more accurate results, the SE-590 spectrometer is used to verify the data, and the effects of atmospheric photon backscattering is examined. The spectrometer and radiosonde data confirm the accuracy of using a narrow and a wide channel centered on the same wavelength to determine water vapor amounts. The technique is suitable for cloudless conditions and can contribute to atmospheric corrections of land-surface parameters.

Frouin, Robert↗

The Use of Sage Water Vapor Data for Investigating Climate Change Issues

SAGE water vapor data has proven valuable for addressing several of the important issues in climate change research. It has been used to investigate how the upper troposphere water vapor responds to warming and convection, a key question in understanding the water vapor feedback to anthropogenic global warming. In the case of summer versus winter differences, SAGE results showed that the upper tropospheric relative humidity remained approximately constant; this result was in general agreement with how a GCM handled the seasonal difference, and gave credence to the argument that the GCM was not overestimating the water vapor feedback associated with convection. In addition, the convection-water vapor relationship was investigated further using SAGE water vapor and ISCCP cloud data. The results showed that upper tropospheric drying did appear to occur simultaneously with deep convective events in the tropics, only to be replaced by moistening a few hours later, associated (most likely) with the reevaporation of moisture from anvil clouds. The total effect was, again, a moistening of the upper troposphere associated with convection. Calculation of the actual trends in upper tropospheric moisture is a potential goal for SAGE data usage; trends calculated with radiosonde data, or instruments calibrated with radiosonde data have the problem of the effect of changing radiosonde instruments. SAGE data have in effect been used to compare different radiosondes through comparisons, and could continue to do so. SAGE 3 should also help clarify the absolute accuracy of SAGE retrievals in the troposphere. and its consequences. Model results show that water vapor increases can help explain the observations of stratospheric cooling, along with increasing C02 and ozone reduction. SAGE has been shown to provide trends similar to those of some other satellite and in situ retrievals, with increasing water vapor over time. However, SAGE is impacted by aerosol contamination which must be removed from the data; approaches used in the past will be reviewed. The SAGE water vapor errors, if taken literally, would make it hard to justify using SAGE data for such trends, and the error bars must be investigated. Stratospheric water vapor increases, like tropospheric increases, would lead to noticeable warming at the surface, and their changes must be quantified.

Rind, D.↗

High altitude aircraft water vapor measurements.

A hygrometer for water vapor measurements from an aircraft was developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on the NASA Convair 990 and on a USAF B-57 aircraft. Water vapor measurements from the Convair 990 were conducted up to 40,000 ft with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 ft.

Hilsenrath, E.↗

Line shape parameters of air-broadened water vapor transitions in the nu(1) and nu(3) spectral region

A Bruker IFS-120HR Fourier transform spectrometer located at the Pacific Northwest Laboratory (PNNL) in Richland, Washington was used to record a series of spectra of pure H2O and air-broadened H2O in the regions of the ¦1 and ¦3 bands (3450-4000 cm-1) at different pressures, mperatures and volume mixing ratios of H2O in air. 18 high-resolution, high signal- to-noise (S/N) ratio absorption spectra were recorded at T = 268, 296 and 353 K using two temperature-controlled absorption cells with path lengths of 9.906(1) and 19.95(1) cm. The resolution of the spectra recorded with the 9.906 cm and 19.95 cm absorption cells was 0.006 and 0.008 cm-1, respectively. A multispectrum nonlinear least squares fitting technique was employed to fit all the eighteen spectra simultaneously to retrieve 313 accurate line positions, 315 intensities, 229 Lorentz air-broadened half- width and 213 air-shift coefficients and their temperature dependences (136 for air-broadened width and 128 for air-shift coefficients, respectively). Room temperature self-broadened half-width coefficients for 209 transitions and self-shift coefficients for 106 transitions were also measured. Line mixing coefficients were experimentally determined for isolated sets of 10 transition pairs for H2O-air and 8 transition pairs for H2O-H2O using the off-diagonal relaxation matrix element formalism, and 85 quadratic speed dependence parameters were measured. Modified Complex Robert-Bonamy (MCRB) calculations of self-, and air-broadened (from N2- and O2-broadening) half-width and air-shift coefficients, and temperature dependence exponents of air-broadened half-width coefficients are made. The measurements and calculations are compared with each other and with similar parameters reported in the literature.

H2O, spectral line shapes, air-broadening, tempera↗

Investigation of water vapor motion winds from geostationary satellites

Water vapor imagery from geostationary satellites has been available for over a decade. These data are used extensively by operational analysts and forecasters, mainly in a qualitative mode (Weldon and Holmes 1991). In addition to qualitative applications, motions deduced in animated water vapor imagery can be used to infer wind fields in cloudless regimes, thereby augmenting the information provided by cloud-drift wind vectors. Early attempts at quantifying the data by tracking features in water vapor imagery met with modest success (Stewart et al. 1985; Hayden and Stewart 1987). More recently, automated techniques have been developed and refined, and have resulted in upper-level wind observations comparable in quality to current operational cloud-tracked winds (Laurent 1993). In a recent study by Velden et al. (1993) it was demonstrated that wind sets derived from Meteosat-3 (M-3) water vapor imagery can provide important environmental wind information in data void areas surrounding tropical cyclones, and can positively impact objective track forecasts. M-3 was repositioned to 75W by the European Space Agency in 1992 in order to provide complete coverage of the Atlantic Ocean. Data from this satellite are being transmitted to the U.S. for operational use. Compared with the current GOES-7 (G-7) satellite (positioned near 112W), the M-3 water vapor channel contains a superior horizontal resolution (5 km vs. 16 km ). In this paper, we examine wind sets derived using automated procedures from both GOES-7 and Meteosat-3 full disk water vapor imagery in order to assess this data as a potentially important source of large-scale wind information. As part of a product demonstration wind sets were produced twice a day at CIMSS during a six-week period in March and April (1994). These data sets are assessed in terms of geographic coverage, statistical accuracy, and meteorological impact through preliminary results of numerical model forecast studies.

Velden, Christopher S.↗

Model polymer etching and surface modification by a time modulated RF plasma jet: role of atomic oxygen and water vapor

The surface interaction of a well-characterized time modulated radio frequency (RF) plasma jet with polystyrene, poly(methyl methacrylate) and poly(vinyl alcohol) as model polymers is investigated. The RF plasma jet shows fast polymer etching but mild chemical modification with a characteristic carbonate ester and NO formation on the etched surface. By varying the plasma treatment conditions including feed gas composition, environment gaseous composition, and treatment distance, we find that short lived species, especially atomic O for Ar/1% O 2 and 1% air plasma and OH for Ar/1% H 2 O plasma, play an essential role for polymer etching. For O 2 containing plasma, we find that atomic O initiates polymer etching and the etching depth mirrors the measured decay of O atoms in the gas phase as the nozzlesurface distance increases. Here, the etching reaction probability of an O atom ranging from 10 –4 to 10 –3 is consistent with low pressure plasma research. We also find that adding O 2 and H 2 O simultaneously into Ar feed gas quenches polymer etching compared to adding them separately which suggests the reduction of O and OH density in Ar/O 2 /H 2 O plasma.

atomic O↗

Possible near-IR channels for remote sensing precipitable water vapor from geostationary satellite platforms

Remote sensing of troposheric water vapor profiles from current geostationary weather satellites is made using a few broadband infrared (IR) channels in the 6-13 micron region. Uncertainties greater than 20% exist in derived water vapor values just above the surface from the IR emission measurements. In this paper, we propose three near-IR channels, one within the 0.94-micron water vapor band absorption region, and the other two in nearby atmospheric windows, for remote sensing of precipitable water vapor over land areas, excluding lakes and rivers, during daytime from future geostationary satellite platforms. The physical principles are as follows. The reflectance of most surface targets varies approximately linearly with wavelength near 1 micron. The solar radiation on the sun-surface-sensor ray path is attenuated by atmospheric water vapor. The ratio of the radiance from the absorption channel with the radiances from the two window channels removes the surface reflectance effects and yields approximately the mean atmospheric water vapor transmittance of the absorption channel. The integrated water vapor amount from ground to space can be obtained with a precision of better than 5% from the mean transmittance. Because surface reflectances vary slowly with time, temporal variation of precipitable water vapor can be determined reliably. High spatial resolution, precipitable water vapor images are derived from spectral data collected by the Airborne Visable-Infrared Imaging Spectrometer, which measures solar radiation reflected by the surface in the 0.4-2.5 micron region in 10-nm channels and has a ground instantaneous field of view of 20 m from its platform on an ER-2 aircraft at 20 km. The proposed near-IR reflectance technique would complement the IR emission techniques for remote sensing of water vapor profiles from geostationary satellite platforms, especially in the boundary layer where most of the water vapor is located.

Gao, B.-C.↗

Electrification in Hurricanes over the Tropical Americas: Implication for Stratospheric Water Vapor

This study explores the relation between lightning activity and water vapor in the Tropical Tropopause Layer (TTL) over hurricane systems in the Tropical Americas. The hypothesis herein is that hurricanes that exhibit enhanced lightning activity are associated with stronger updrafts that can transport more moisture directly into the TTL (and subsequently into the tropical stratosphere) or even directly into the tropical stratosphere over this region. The TTL over the Tropical Americas, which includes the Caribbean and Gulf of Mexico, is of particular interest, because summertime cold point tropopause is the lowest in height and thus the warmest in temperature over the tropics. The latter condition implies higher saturation values and thus potential for more water vapor to enter the stratosphere. Climate forecast is very sensitive to stratospheric water vapor abundance, because of the key role that water vapor plays in regulating the chemical and radiative properties of the stratosphere. Given the potential for increases in hurricane intensity and frequency under predicted warmer conditions, it becomes essential to understand the effect of hurricanes on stratospheric water vapor. In this study, we use a combination of ground and space-borne observations as well as trajectory calculations. The observations include: cloud-to-ground (CG) lightning data from the U.S. National Lightning Detection Network (NLDN), geostationary infrared observations from the National Climatic Data Center Hurricane Satellite (HURSAT) data set, cloud properties from Aqua-MODIS, and water vapor from Aura-MLS. We analyze hurricanes from the 2005 season when Aura-MLS data are available, namely: Dennis, Emily, Katrina, Rita, and Wilma. Our analysis consists of examining CG lightning, cloud-top properties, and TTL water vapor (i.e., 100 and 147 mb) over the hurricane while it remains over water in the Tropical Americas region. We investigate daily as well as diurnal statistical properties. The hurricanes analyzed in this study showed that lightning activity is negatively correlated with minimum infrared brightness temperature and positively correlated with 100-mb water vapor. An examination of the maxima in water vapor observed over the hurricane not only shows larger magnitudes, but also larger differences between water vapor averages and water vapor maxima over the hurricane as lightning activity increases. Trajectory calculations are performed using the Flextra model in order to investigate the fate of the moister air masses found in the TTL.

Pittman, Jasna V.↗

ZnO($10\bar 10$) Surface Hydroxylation under Ambient Water Vapor

The interaction of water vapor with a single crystal ZnO($10\bar 10$) surface was investigated using synchrotron-based ambient pressure X-ray photoelectron spectroscopy (APXPS). Two isobaric experiments were performed at 0.3 and 0.07 Torr water vapor pressure at sample temperatures ranging from 750 to 295 K up to a maximum of 2% relative humidity (RH). Below 10–4 % RH the ZnO($10\bar 10$) interface is covered with ~0.25 monolayers of OH groups attributed to dissociation at nonstoichiometric defect sites. At ~10–4 % RH there is a sharp onset in increased surface hydroxylation attributed to reaction at stoichiometric terrace sites. The surface saturates with an OH monolayer ~0.26 nm thick and occurs in the absence of any observable molecularly bound water, suggesting the formation of a 1 × 1 dissociated monolayer structure. This is in stark contrast to ultrahigh vacuum experiments and molecular simulations that show the optimum structure is a 2 × 1 partially dissociated H2O/OH monolayer. The sharp onset to terrace site hydroxylation at ~10–4 % RH for ZnO($10\bar 10$) contrasts with APXPS observations for MgO(100) which show a sharp onset at 10–2 % RH. A surface thermodynamic analysis reveals that this shift to lower RH for ZnO($10\bar 10$) compared to MgO(100) is due to a more favorable Gibbs free energy for terrace site hydroxylation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗