Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WATER GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microwave irradiation assisted rapid synthesis of Fe-Ru bimetallic nanoparticles and their catalytic properties in water-gas shift reaction

Fe-Ru bimetallic nanoparticles were prepared by a microwave irradiation assisted glycol reduction method using poly-N-vinyl-2-pyrrolidone (PVP) as protective agent. The structure and morphology of the nanoparticles were characterized by X-ray diffraction (XRD), energy-dispersive X-ray analysis (EDXA) and high-resolution transmission electron microscopy (HRTEM). EDXA and XRD analysis confirmed the presence of Fe and Ru. The bimetallic nanoparticles were subsequently loaded onto an MgAl{sub 2}O{sub 4} supporter with K{sub 2}O as promoters and used as catalyst for water-gas shift reaction. The results indicated that the FeRu bimetallic nanoparticles exhibit high catalytic activity for water-gas shift reaction due to the synergistic effect between iron and ruthenium. Potassium oxide can enhance the CO selectivity of the catalyst significantly besides increasing the catalyst activity.

36 MATERIALS SCIENCE↗

Elucidation of the Reaction Mechanism for High-Temperature Water Gas Shift over an Industrial-Type Copper–Chromium–Iron Oxide Catalyst

The water gas shift (WGS) reaction is of critical importance for the chemical industry, as it constitutes, coupled with methane reforming, the main industrial route to produce hydrogen. Copper–chromium–iron oxide-based catalysts have been widely used for the high-temperature WGS reaction industrially. The WGS reaction mechanism by the CuCrFeO x catalyst has been debated for years, mainly between a “redox” mechanism involving the participation of atomic oxygen from the catalyst and an “associative” mechanism proceeding via a surface formate-like intermediate. Here, advanced in situ characterization techniques (infrared spectroscopy, temperature-programmed surface reaction (TPSR), near-ambient pressure XPS (NAP-XPS), and inelastic neutron scattering (INS)) were applied to determine the nature of the catalyst surface and identify surface intermediate species under WGS reaction conditions. The surface of the CuCrFeO x catalyst is found to be dynamic and becomes partially reduced under WGS reaction conditions, forming metallic Cu nanoparticles on Fe 3 O 4 . Neither in situ IR not INS spectroscopy detect the presence of surface formate species during WGS. TPSR experiments demonstrate that the evolution of CO 2 and H 2 from the CO/H 2 O reactants follows different kinetics than the evolution of CO 2 and H 2 from HCOOH decomposition (molecule mimicking the associative mechanism). Steady-state isotopic transient kinetic analysis (SSITKA) (CO + H 2 16 O → CO + H 2 18 O) exhibited significant 16 O/ 18 O scrambling, characteristic of a redox mechanism. Computed activation energies for elementary steps for the redox and associative mechanism by density functional theory (DFT) simulations indicate that the redox mechanism is favored over the associative mechanism. The combined spectroscopic, computational, and kinetic evidence in the present study finally resolves the WGS reaction mechanism on the industrial-type high-temperature CuCrFeO x catalyst that is shown to proceed via the redox mechanism.

SSITKA↗

Performance of Au/M(x)O(y)/TiO(2) Catalysts in Water-Gas Shift Reaction

Our group recently developed a series of Au/M{sub x}O{sub y}/TiO{sub 2} catalysts for CO oxidation, and demonstrated that some of these catalysts are still active after high-temperature treatment whereas Au/TiO{sub 2} deactivates significantly due to the sintering of gold nanoparticles at elevated temperatures (Ma Z, Overbury SH, Dai S (2007) J Mol Catal A 273:97). In the current work, the performance of Au/M{sub x}O{sub y}/TiO{sub 2} (M = Al, Ca, Fe, Zn, Ga, Y, Zr, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Yb) catalysts in water-gas shift (WGS) reaction was evaluated. The influences of different metal oxide (M{sub x}O{sub y}) additives and pretreatment temperatures were investigated, and the catalyst stability as a function of reaction time on stream was tested. Some of these novel gold catalysts, with high activity and stability in water-gas shift, furnish new possibilities for further fundamental research and industrial development.

36 MATERIALS SCIENCE↗

On the Importance of Metal–Oxide Interface Sites for the Water–Gas Shift Reaction Over Pt/CeO2 Catalysts

The mechanism of water–gas shift reaction at the three-phase boundary of Pt/CeO2 catalysts has been investigated using density functional theory and microkinetic modeling to better understand the importance of metal–oxide interface sites in heterogeneous catalysis. Analysis of a microkinetic model based on parameters obtained from first principles suggests that both the “Redox pathway” and the “Associative carboxyl pathway with redox regeneration” could operate on Pt/CeO2 catalysts. Although (1) only few interfacial Pt atoms are found to be catalytically active at low temperatures due to strong adsorption of CO and (2) interfacial O–H bond breakage is difficult due to the high reducibility of ceria, interface sites are 2–3 orders of magnitude more active than Pt (1 1 1) and stepped Pt surface sites and therefore effectively determine the overall activity of Pt/CeO2. The high activity of Pt/CeO2 interface sites originates from a significantly enhanced water activation and dissociation at interfacial oxygen vacancies.

Environmental Molecular Sciences Laboratory↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CsO x Nanostructures on Au(111): Morphology- and Size-dependent Activity for the Water–Gas Shift Reaction

Alkali oxides are typically used as promoters of heterogeneous catalysts for the water–gas shift (WGS; H 2 O + CO → H 2 + CO 2 ) reaction. On Au(111), CsO x exhibits diverse nanostructures at varying coverages, as revealed by scanning tunneling microscopy. Clusters of cesium oxide (Cs 2 O 2 ) nucleate at elbow sites of the Au(111) herringbone when θ Cs is less than 0.1 ML. Subsequently, these clusters transform into two-dimensional (2D) islands (Cs 2 O, Cs 2 O 2 , CsO 2 ) as the cesium coverage increases (θ Cs > 0.1 ML). Both types of CsO x nanostructures enable the WGS process on Au(111). The highest activity was seen for the cesium oxide clusters which facilitated the partial dissociation of water and binding of CO. The CO ads and OH ads groups were not strongly bound and probably reacted to yield a short-lived HOCO intermediate that led to gaseous H 2 and CO 2 . The 2D islands of CsO x also enabled the WGS but their efficiency was reduced due to the formation of cesium hydroxide compounds (limiting mobility of OH groups) and the generation of CO 3 and C species (blocking of active centers). The fact that the performance of the CsO x /Au(111) catalysts changed dramatically with variations in the chemical properties of the CsO x nanostructures indicates that the alkali oxide was an integral part of the active phase, playing a central role in the activation and conversion of the reactants. To attach the label of “promoter” to CsO x is a simplification that does not help in the design and optimization of catalysts for C1 chemistry. In conclusion, to achieve a rational design, one must consider the structural and chemical properties of the alkali oxide.

36 MATERIALS SCIENCE↗

Water-gas Shift Reaction on oxide/Cu(111): Rational Catalyst Screening from Density Functional Theory

Developing improved catalysts based on a fundamental understanding of reaction mechanism has become one of the grand challenges in catalysis. A theoretical understanding and screening the metal-oxide composite catalysts for the water-gas shift (WGS) reaction is presented here. Density functional theory was employed to identify the key step for the WGS reaction on the Au, Cu-oxide catalysts, where the calculated reaction energy for water dissociation correlates well with the experimental measured WGS activity. Accordingly, the calculated reaction energy for water dissociation was used as the scaling descriptor to screen the inverse model catalysts, oxide/Cu(111), for the better WGS activity. Our calculations predict that the WGS activity increases in a sequence: Cu(111), ZnO/Cu(111) < TiO{sub 2}/Cu(111), ZrO{sub 2}/Cu(111) < MoO{sub 3}/Cu(111). Our results imply that the high performances of Au, Cu-oxide nanocatalysts in the WGS reaction rely heavily on the direct participation of both oxide and metal sites. The degree that the oxide is reduced by Cu plays an important role in determining the WGS activity of oxide/Cu catalysts. The reducible oxide can be transformed from the fully oxidized form to the reduced form due to the interaction with Cu and, therefore, the transfer of electron density from Cu, which helps in releasing the bottleneck water dissociation and, therefore, facilitating the WGS reaction on copper.

30 DIRECT ENERGY CONVERSION↗

Titania-Supported Single-Atom Platinum Catalyst for Water-Gas Shift Reaction

Density functional theory (DFT) and microkinetic modeling are used to examine the water-gas shift (WGS) reaction on TiO 2 (110)-supported single Pt atoms. A CO-adsorbed Pt atom supported on a TiO 2 surface exhibits a lower activity for the WGS than the Pt 2+ ion supported on a doped TiO 2 surface, although DFT predicts the CO-adsorbed Pt on an undoped TiO 2 surface to be thermodynamically more stable. Finally, trends observed in WGS activity for different active sites of TiO 2 -supported Pt catalysts can be explained in terms of CO adsorption strength and the ability to form an oxygen vacancy on the oxide support.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Study of Support Effects for the Water-Gas-Shift Reaction over Cu

The water–gas-shift (WGS) reaction was studied on a series of supported Cu catalysts in which the MgAl 2 O 4 (MAO) support was modified by depositing ZnO, CeO 2 , Mn2O 3 and CoO using Atomic Layer Deposition (ALD). Addition of Cu by one ALD cycle gave rise to catalysts with nominally 1-wt% Cu. A 1.1-wt% Cu/MAO catalyst prepared by ALD exhibited twice the dispersion but ten times the WGS activity of a 1-wt% Cu/MAO catalyst prepared by impregnation, implying that the reaction is structure sensitive. However, Cu catalysts prepared with the ZnO, CeO 2 , and Mn 2 O 3 films showed negligible differences from that of the Cu/MAO catalyst, implying that these oxides did not promote the reaction. Cu catalysts prepared on the CoO film showed a slightly lower activity, possibly due to alloy formation. The implications of these results for the development of better WGS catalysts is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Characterization of CuFe2O4 and Cu/Fe3O4 Water-Gas Shift Catalysts

Mixtures of copper and iron oxides are used as industrial catalysts for the water-gas shift (WGS, CO + H2O f H2 + CO2). In-situ time-resolved X-ray diffraction, X-ray absorption fine structure, and atomic pair distribution function analysis were used to study the reduction of CuFe2O4 with CO and the behavior of CuFe2O4 and Cu/Fe2O3 catalysts under WGS reaction conditions. MetalToxygenTmetal interactions enhance the stability of Cu 2+ and Fe 3+ in the CuFe2O4 lattice, and the mixed-metal oxide is much more difficult to reduce than CuO or Fe2O3. Furthermore, after heating mixtures of CuFe2O4/CuO in the presence of CO or CO/H2O, the cations of CuO migrate into octahedral sites of the CuFe2O4 lattice at temperatures (200-250 C) in which CuO is not stable. Above 250 C, copper leaves the oxide, the occupancy of the octahedral sites in CuFe2O4 decreases, and diffraction lines for metallic Cu appear. From 350 to 450 C, there is a massive reduction of CuFe2O4 with the formation of metallic Cu and Fe3O4. At this point, the sample becomes catalytically active for the production of H2 from the reaction of H2O with CO. Neutral Cu 0 (i.e., no Cu 1+ or Cu 2+ cations) is the active species in the catalysts, but interactions with the oxide support cannot be neglected. These studies illustrate the importance of in situ characterization when dealing with mixed-metal oxide WGS catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ Characterization of CuFe2O4 and Cu/Fe3O4 Water-Gas Shift Catalysts

Mixtures of copper and iron oxides are used as industrial catalysts for the water-gas shift (WGS, CO + H2O → H2 + CO2). In-situ time-resolved X-ray diffraction, X-ray absorption fine structure, and atomic pair distribution function analysis were used to study the reduction of CuFe2O4 with CO and the behavior of CuFe2O4 and Cu/Fe2O3 catalysts under WGS reaction conditions. Metal↔oxygen↔metal interactions enhance the stability of Cu2+ and Fe3+ in the CuFe2O4 lattice, and the mixed-metal oxide is much more difficult to reduce than CuO or Fe2O3. Furthermore, after heating mixtures of CuFe2O4/CuO in the presence of CO or CO/H2O, the cations of CuO migrate into octahedral sites of the CuFe2O4 lattice at temperatures (200-250 oC) in which CuO is not stable. Above 250 oC, copper leaves the oxide, the occupancy of the octahedral sites in CuFe2O4 decreases, and diffraction lines for metallic Cu appear. From 350 to 450 oC, there is a massive reduction of CuFe2O4 with the formation of metallic Cu and Fe3O4. At this point, the sample becomes catalytically active for the production of H2 from the reaction of H2O with CO. Neutral Cu0 (i.e. no Cu+1 or Cu+2 cations) is the active species in the catalysts, but interactions with the oxide support are necessary in order to obtain high catalytic activity. These studies illustrate the importance of in-situ characterization when dealing with mixed-metal oxide WGS catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Redistribution of Ru in Fe 2 O 3 –Ru Nanocatalysts through an Oxidative Pretreatment Improves Reverse Water–Gas Shift Activity

We have synthesized Fe–Ru nanoparticles via a solvothermal method to create catalysts for the reverse water–gas shift reaction and demonstrated the impact of reductive and oxidative pretreatments on both catalytic performance and structure. Catalytic testing showed improved activity after exposure to O 2 at 600 °C. In contrast, the activity became lower if then exposed to H 2 at 600 °C. Environmental scanning transmission electron microscopy and scanning electron microscopy showed that exposure to O 2 at 600 °C changes the morphology and completely oxidizes Fe into Fe 2 O 3 . Exposure to H 2 at elevated temperature caused Ru coalescence at the surface of the nanoparticle, forming clusters which decreased the optimization of Ru. Reoxidation of the particles exposed to H 2 , however, caused a redistribution of Ru that appears beneficial in maximizing Ru exposure and synergy with Fe oxide, with no major changes in the morphology and oxide structure. Furthermore, our diagnostics demonstrate the complex and reversible rearrangements possible in these multicomponent particles and the benefits of oxidative pretreatment to enhance or regenerate Fe–Ru catalysts in other important catalytic reactions such as Fischer–Tropsch synthesis.

Fe−Ru nanoparticles↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

03 NATURAL GAS↗

The effect of PdZn particle size on reverse-water-gas-shift reaction

The effect of PdZn particle size on the catalytic activity of Pd/ZnO catalysts for the reverse-water-gas-shift (RWGS) reaction was studied. The PdZn particle size was varied by adjusting Pd loading and reducing the catalysts at different temperatures. XRD and IR spectroscopy characterization confirmed the absence of metallic Pd on the catalyst surface. Consequently, the effect of PdZn alloy particle size on the RWGS reaction can be unambiguously studied without the complication of reactions catalyzed by metallic Pd. The results indicated that the turnover frequency increases as the PdZn crystallite size decreases. Interestingly, this structure relationship between PdZn particle size and RWGS activity is consistent with that previously observed for the steam reforming of methanol, i.e., higher CO selectivity on smaller PdZn particles. Thus, RWGS has been identified as a likely potential reaction pathway to undesired CO formation in methanol steam reforming on Pd/ZnO catalysts for hydrogen production.

08 HYDROGEN↗

Carbon Nanotube Formation on Cr-Doped Ferrite Catalyst during Water Gas Shift Membrane Reaction: Mechanistic Implications and Extended Studies on Dry Gas Conversions

A nanocrystalline chromium-doped ferrite (FeCr) catalyst was shown to coproduce H2 and multiwalled carbon nanotubes (MWCNTs) during water gas shift (WGS) reaction in a H2-permselective zeolite membrane reactor (MR) at reaction pressures of ~20 bar. The FeCr catalyst was further demonstrated in the synthesis of highly crystalline and dimensionally uniform MWCNTs from a dry gas mixture of CO and CH4, which were the apparent sources for MWCNT growth in the WGS MR. In both the WGS MR and dry gas reactions, the operating temperature was 500 °C, which is significantly lower than those commonly used in MWCNT production by chemical vapor deposition (CVD) method from CO, CH4, or any other precursor gases. Extensive ex situ characterizations of the reaction products revealed that the FeCr catalyst remained in partially reduced states of Fe3+/Fe2+ and Cr6+/Cr3+ in WGS membrane reaction while further reduction of Fe2+ to Fe0 occurred in the CO/CH4 dry gas environments. The formation of the metallic Fe nanoparticles or catalyst surface dramatically improved the crystallinity and dimensional uniformity of the MWCNTs from dry gas reaction as compared to that from WGS reaction in the MR. Reaction of the CO/CH4 mixture containing 500 ppmv H2S also resulted in high-quality MWCNTs similar to those from the H2S-free feed gas, demonstrating excellent sulfur tolerance of the FeCr catalyst that is practically meaningful for utilization of biogas and cheap coal-derived syngas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗