Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voxels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Improved accuracy of S-value-based dosimetry: a guide to transition from Cristy–Eckerman to ICRP adult phantoms

Background: In 2016, the International Commission on Radiological Protection (ICRP) published the results of Monte Carlo simulations performed using updated and anatomically realistic voxelized phantoms. The resulting specific absorbed fractions are based on more realistic human anatomy than those computed in the stylized, geometrical Cristy–Eckerman (CE) phantom. Despite this development, the ICRP-absorbed fractions have not been widely adopted for radiopharmaceutical dosimetry. To help make the transition, we have established a correspondence between source and target tissues defined in the CE phantom and those defined in the ICRP phantoms. Results: The ICRP phantom has 79 source regions and 43 target regions in comparison with the 23 source and 18 target tissue regions defined in the CE phantom. The ICRP phantom provides tissue regions with greater anatomical detail. Some of this additional detail is focused on radiation protection and dosimetry of inhaled/ingested radioactivity. Some, but not all, of this detail is useful and appropriate for radiopharmaceutical therapy. We have established the correspondence between CE and ICRP phantom source and target regions and attempted to highlight the ICRP source tissues relevant to radiopharmaceutical therapy (RPT). This paper provides tables and figures highlighting the correspondences established. Conclusion: The results provide assistance in transitioning from CE-stylized phantoms to the anatomically accurate voxelized ICRP phantoms. It provides specific guidance for porting the total absorbed activity for regions as defined in the CE phantom to regions within the ICRP phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

SOC Synthetic Microstructure Bank

QUICK START: Start with property_library.html (can be found by typing the filename into the query box) and use the interactive table to filter, sort, and select a microstructure with the desired properties. Search for the alphabetic code to obtain the corresponding dataset. Full description: This is a bank of 1,970 unique 3-phase electrode microstructure files. When you account for reassigning phase IDs (e.g. declare that 1=Ni and 2=pore, instead of 1=pore and 2=Ni), it actually represents 5,910 unique electrode microstructures, each of which could be considered to be either an air or a fuel electrode (e.g. declare that the phase IDs correspond to pore, Ni, and YSZ; or that they correspond to pore, LSCF, and GDC; or whatever electron-conductor and ion-conductor combination is being studied). The voxel size is 50 nm and each electrode file contains a 4x4 grid of (12.5 micron)^3 sub-volumes. If placed together in a grid, they comprise a 50x50x12.5 micron electrode (note that the interfaces between sub-volumes will be sharp; this can be mitigated via simulating annealing/relaxation). The sub-volumes can also be used individually for a reasonably sized 12.5 micron cubic region-of-interest. A user can simply consider the voxel size to be a different value to rescale the volumes (and all of their morphological features, including particle size) as desired. These microstructures were generated using DREAM3D. The general procedure is outlined in https://doi.org/10.1016/j.jpowsour.2018.03.025 The file names are an alphabetic code having to do with the input parameters used in DREAM3D when they were generated. Most users would be best served by starting with the file property_library.html or property_library_subvols.html (which lists properties for each individual subvolume). These files contain a catalogue of the actual, measured properties of every microstructure in the database. Any combination of property values can be filtered and sorted until a desired electrode is found, at which point the user can find the file corresponding to that alphabetic code. The properties in the catalogue include connected TPB density, and for each phase: phase fraction, average particle size, polydispersity of particle size, tortuosity, and connected pair-wise interfacial area. They also include what fraction of each property is connected through to the interfaces of the volume. If the desired combination of properties is not found at first, remember that the phase IDs can be re-assigned arbitrarily, e.g. swapping 1s and 2s. In fact, the database was generated with this in mind so as not to generate redundant microstructures. If the database does not contain the desired property combinations, try to search for the other possible permutations of those properties with re-assigned phase IDs. Please cite https://doi.org/10.1149/10301.0909ecst for use. Please contact the maintainer, William K. Epting, for additional information or assistance.

3D microstructure↗

SOC Microstructural Analyzer

This program was designed to analyze the 3-phase microstructure of the electrodes of a solid oxide fuel cell (SOFC) or electrolysis cell (SOEC), both referred to in combination as a solid oxide cell (SOC). It is agnostic to the exact system, so it could be repurposed to analyze any 3-phase microstructure. This tool directly analyzes segmented voxel-based data that has been segmented into phase IDs (1,2,3). The voxels will be analyzed directly for: - tortuosity factors - triple phase boundaries - 2-phase interfacial areas, using a meshed isosurface - mean diameters of each phase, using an inscribed sphere method - standard deviation of the diameters of each phase, from the same inscribed sphere data - connectivity information Comprehensive information is available in the readme file (within the zipped repository in Markdown language, and also available here as a rendered PDF). Please cite this page / DOI, as well as https://doi.org/10.1111/jace.14775, for usage.

3D microstructure↗

Tomographic optical emission spectroscopy of atmospheric pressure plasma interacting with complex surfaces

Plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and interfacing material properties. For example, guided streamers that transition to surface ionization waves (SIWs) and propagate over structured dielectrics experience field enhancements that can lead to localized increases in ionization rates and complex 3D configurations that are difficult to analyze. Investigating these configurations requires techniques than can provide a more complete 3D picture. To help address this capability gap, a tomographic optical emission spectroscopy (tomo-OES) diagnostic system has been developed at Sandia National Laboratories that can resolve SIWs. The system includes four intensified cameras that measure the angular projections of the plasma light emission through bandpass filters. A dot calibration target co-registers each angular projection to the same voxel grid and an algebraic reconstruction technique (ART) recovers the light intensity at each voxel. An atmospheric pressure plasma jet (APPJ), provided by Peter Bruggeman, has been investigated and representative results are shown in Figure 1. Here, a bandpass filter was used to isolate emission from the N 2 second positive system (SPS) at 337.1 nm to capture the transition of the streamer to SIW on a planar dielectric surface (relative permittivity 3.3) located 3 mm below the APPJ [3]. The surface wave velocity was 3.5x10 4 (m/s), consistent with measurements made by Steven Shannon. Characterization of this APPJ will support the group effort of standing up a reproducible APPJ across institutions for applications such as liquid treatment, catalysis, and plasma aided combustion. Future work will investigate non-planar surfaces and eventually develop tomographic laser-induced fluorescence (tomo-LIF) approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alpha-Quartz Plastic Strength Investigation Via Diffraction Experiments on Novaculite Using A D-Dia and Elastic Plastic Self- Consistent Interpretation [Thesis}

X-Ray Tomography. Porosity is commonly measured using mercury injection (MI) or water immersion porosimeter (WIP). Both MI and WIP utilize pressure to fill open voids with mercury or water respectively. A measure of the volume change of the sample is then used to estimate the percentage of open voids. However, for the purpose of rheological study it is important to get an accurate measure of open and closed voids. X-ray tomography has been selected as it offers a three-dimensional view into the sample that can quantify all pores limited only by the voxel size which is in the micron range for this study. Radiographs for tomography were collected at the Material Science and Technology Division at Los Alamos National Lab using the Carl Zeiss Xradio 520 instrument and Scout-and-Scan version 16.1 operating software. Two samples were imaged, the starting material and the deformed sample SiO2_65. 3001 radiographs were taken of the starting material with a 6 second exposure time using a 4x objective lens. The x-ray beam was set to 60 kilovoltage peak (kVp) and 5 watts. 1901 radiographs were taken of SiO2_65 with a 25 second exposure time using a 10x objective lens. The x-ray beam was set to 80 kVp and 7 watts. Radiograph files were analyzed by Brian Patterson using Avizo. Void and inclusion volumes were output by voxel sized (1.03 μm) slices, used to calculate a total percentage volume for the starting material.

36 MATERIALS SCIENCE↗

Cooling rate and dendrite spacing control in direct metal deposition printed Cu-Fe alloys

Over the last several decades, additive manufacturing (AM) has been primarily used for rapid prototyping or to create novel geometries that would be difficult or impossible to create by normal manufacturing methods. More recently, research has been focused on expanding the list of materials that can be made through additive manufacturing, opening a greater range of material properties for this manufacturing method. Due to the unusual conditions during AM, including the high cooling rates and voxel by voxel method of production, AM parts often have anisotropic material microstructures and properties. In this investigation, the laser power, composition, and nozzle head speed during direct metal deposition of copper-iron alloys was varied to understand how the grain structure within the printed parts could be changed and controlled. The resulting dendrite spacing was measured and compared to calculated cooling rates from Gaussian beams on flat plates under similar material and laser properties, which resulted in a cooling rate to dendrite spacing relationship following an inverse square root, as is found in other dendritic systems [Young and Kerkwood, Metall. Trans. A 6, 197–205 (1975)]. Thus, it is demonstrated that in the Cu-Fe system, dendrite spacing can be controlled through manipulation of printing parameters.

36 MATERIALS SCIENCE↗

Method for beam hardening correction in quantitative computed X-ray tomography

Each voxel is assumed to contain exactly two distinct materials, with the volume fraction of each material being iteratively calculated. According to the method, the spectrum of the X-ray beam must be known, and the attenuation spectra of the materials in the object must be known, and be monotonically decreasing with increasing X-ray photon energy. Then, a volume fraction is estimated for the voxel, and the spectrum is iteratively calculated.

Yan, Chye Hwang↗

Analysis of Mass Averaged Tissue Doses in CAM, CAF, MAX, and FAX

To estimate astronaut health risk due to space radiation, one must have the ability to calculate exposure-related quantities averaged over specific organs and tissue types. In this study, we first examine the anatomical properties of the Computerized Anatomical Man (CAM), Computerized Anatomical Female (CAF), Male Adult voXel (MAX), and Female Adult voXel (FAX) models by comparing the masses of various tissues to the reference values specified by the International Commission on Radiological Protection (ICRP). Major discrepancies are found between the CAM and CAF tissue masses and the ICRP reference data for almost all of the tissues. We next examine the distribution of target points used with the deterministic transport code HZETRN to compute mass averaged exposure quantities. A numerical algorithm is used to generate multiple point distributions for many of the effective dose tissues identified in CAM, CAF, MAX, and FAX. It is concluded that the previously published CAM and CAF point distributions were under-sampled and that the set of point distributions presented here should be adequate for future studies involving CAM, CAF, MAX, or FAX. It is concluded that MAX and FAX are more accurate than CAM and CAF for space radiation analyses.

Slaba, Tony C.↗

3D Visualization of Monte-Carlo Simulation's of HZE Track Structure and Initial Chemical Species

Heavy ions biophysics is important for space radiation risk assessment [1] and hadron-therapy [2]. The characteristic of heavy ions tracks include a very high energy deposition region close to the track (<20 nm) denoted as the track core, and an outer penumbra region consisting of individual secondary electrons (6-rays). A still open question is the radiobiological effects of 6- rays relative to the track core. Of importance is the induction of double-strand breaks (DSB) [3] and oxidative damage to the biomolecules and the tissue matrix, considered the most important lesions for acute and long term effects of radiation. In this work, we have simulated a 56Fe26+ ion track of 1 GeV/amu with our Monte-Carlo code RITRACKS [4]. The simulation results have been used to calculate the energy depiction and initial chemical species in a "voxelized" space, which is then visualized in 3D. Several voxels with dose >1000 Gy are found in the penumbra, some located ~0.1 mm from the track core. In computational models, the DSB induction probability is calculated with radial dose [6], which may not take into account the higher RBE of electron track ends for DSB induction. Therefore, these simulations should help improve models of DSB induction and our understanding of heavy ions biophysics.

Plante, Ianik↗

Calculation of Dose Deposition in Nanovolumes and Simulation of gamma-H2AX Experiments

Monte-Carlo track structure simulations can accurately simulate experimental data: a) Frequency of target hits. b) Dose per event. c) Dose per ion. d) Radial dose. The dose is uniform in micrometers sized voxels; at the nanometer scale, the difference in energy deposition between high and low-LET radiations appears. The calculated 3D distribution of dose voxels, combined with chromosomes simulated by random walk is very similar to the distribution of DSB observed with gamma-H2AX experiments. This is further evidenced by applying a visualization threshold on dose.

Plante, Ianik↗

Development of the Code RITRACKS

A document discusses the code RITRACKS (Relativistic Ion Tracks), which was developed to simulate heavy ion track structure at the microscopic and nanoscopic scales. It is a Monte-Carlo code that simulates the production of radiolytic species in water, event-by-event, and which may be used to simulate tracks and also to calculate dose in targets and voxels of different sizes. The dose deposited by the radiation can be calculated in nanovolumes (voxels). RITRACKS allows simulation of radiation tracks without the need of extensive knowledge of computer programming or Monte-Carlo simulations. It is installed as a regular application on Windows systems. The main input parameters entered by the user are the type and energy of the ion, the length and size of the irradiated volume, the number of ions impacting the volume, and the number of histories. The simulation can be started after the input parameters are entered in the GUI. The number of each kind of interactions for each track is shown in the result details window. The tracks can be visualized in 3D after the simulation is complete. It is also possible to see the time evolution of the tracks and zoom on specific parts of the tracks. The software RITRACKS can be very useful for radiation scientists to investigate various problems in the fields of radiation physics, radiation chemistry, and radiation biology. For example, it can be used to simulate electron ejection experiments (radiation physics).

Plante, Ianik↗

Simulations of DSB Yields and Radiation-induced Chromosomal Aberrations in Human Cells Based on the Stochastic Track Structure Induced by HZE Particles

The formation of double‐strand breaks (DSBs) and chromosomal aberrations (CAs) is of great importance in radiation research and, specifically, in space applications. We are presenting a new particle track and DNA damage model, in which the particle stochastic track structure is combined with the random walk (RW) structure of chromosomes in a cell nucleus. The motivation for this effort stems from the fact that the model with the RW chromosomes, NASARTI (NASA radiation track image) previously relied on amorphous track structure, while the stochastic track structure model RITRACKS (Relativistic Ion Tracks) was focused on more microscopic targets than the entire genome. We have combined chromosomes simulated by RWs with stochastic track structure, which uses nanoscopic dose calculations performed with the Monte‐Carlo simulation by RITRACKS in a voxelized space. The new simulations produce the number of DSBs as function of dose and particle fluence for high‐energy particles, including iron, carbon and protons, using voxels of 20 nm dimension. The combined model also calculates yields of radiation‐induced CAs and unrejoined chromosome breaks in normal and repair deficient cells. The joined computational model is calibrated using the relative frequencies and distributions of chromosomal aberrations reported in the literature. The model considers fractionated deposition of energy to approximate dose rates of the space flight environment. The joined model also predicts of the yields and sizes of translocations, dicentrics, rings, and more complex‐type aberrations formed in the G0/G1 cell cycle phase during the first cell division after irradiation. We found that the main advantage of the joined model is our ability to simulate small doses: 0.05‐0.5 Gy. At such low doses, the stochastic track structure proved to be indispensable, as the action of individual delta‐rays becomes more important.

Ponomarev, Artem↗

Simulations of DSB Yields and Radiation-induced Chromosomal Aberrations in Human Cells Based on the Stochastic Track Structure iIduced by HZE Particles

The formation of double‐strand breaks (DSBs) and chromosomal aberrations (CAs) is of great importance in radiation research and, specifically, in space applications. We are presenting a new particle track and DNA damage model, in which the particle stochastic track structure is combined with the random walk (RW) structure of chromosomes in a cell nucleus. The motivation for this effort stems from the fact that the model with the RW chromosomes, NASARTI (NASA radiation track image) previously relied on amorphous track structure, while the stochastic track structure model RITRACKS (Relativistic Ion Tracks) was focused on more microscopic targets than the entire genome. We have combined chromosomes simulated by RWs with stochastic track structure, which uses nanoscopic dose calculations performed with the Monte‐Carlo simulation by RITRACKS in a voxelized space. The new simulations produce the number of DSBs as function of dose and particle fluence for high‐energy particles, including iron, carbon and protons, using voxels of 20 nm dimension. The combined model also calculates yields of radiation‐induced CAs and unrejoined chromosome breaks in normal and repair deficient cells. The joined computational model is calibrated using the relative frequencies and distributions of chromosomal aberrations reported in the literature. The model considers fractionated deposition of energy to approximate dose rates of the space flight environment. The joined model also predicts of the yields and sizes of translocations, dicentrics, rings, and more complex‐type aberrations formed in the G0/G1 cell cycle phase during the first cell division after irradiation. We found that the main advantage of the joined model is our ability to simulate small doses: 0.05‐0.5 Gy. At such low doses, the stochastic track structure proved to be indispensable, as the action of individual delta‐rays becomes more important.

Ponomarev, Artem↗

Focal Gray Matter Plasticity as a Function of Long Duration Bedrest: Preliminary Results

Long duration spaceflight (i.e., 22 days or longer) has been associated with changes in sensorimotor systems, resulting in difficulties that astronauts experience with posture control, locomotion, and manual control. It is unknown whether and how spaceflight impacts sensorimotor brain structure and function, and whether such changes may potentially underlie behavioral effects. Long duration head down tilt bed rest has been used repeatedly as an exclusionary analog to study microgravity effects on the sensorimotor system [1]. Bed rest mimics microgravity in body unloading and bodily fluid shifts. We are currently testing sensorimotor function, brain structure, and brain function pre and post a 70‐day bed rest period. We will acquire the same measures on NASA crewmembers starting in 2014. Here we present the results of the first eight bed rest subjects. Subjects were assessed at 12 and 7 days before‐, at 7, 30, and ~70 days in‐, and at 8 and 12 days post 70 days of bed rest at the NASA bed rest facility, UTMB, Galveston, TX, USA. At each time point structural MRI scans (i.e., high resolution T1‐weighted imaging and Diffusion Tensor Imaging (DTI)) were obtained using a 3T Siemens scanner. Focal changes over time in gray matter density were assessed using the voxel based morphometry 8 (VBM8) toolbox under SPM. Focal changes in white matter microstructural integrity were assessed using tract based spatial statistics (TBSS) as part of the FMRIB software library (FSL). TBSS registers all DTI scans to standard space. It subsequently creates a study specific white matter skeleton of the major white matter tracts. Non‐parametric permutation based t‐tests and ANOVA's were used for voxel‐wise comparison of the skeletons. For both VBM and TBSS, comparison of the two pre bed rest measurements did not show significant differences. VBM analysis revealed decreased gray matter density in bilateral areas including the frontal medial cortex, the insular cortex and the caudate nucleus from pre to in bed rest. Over the same time period, there was an increase in gray matter density in the cerebellum, occipital, and parietal cortices. The majority of these changes did not recover from during to post bed rest. TBSS analyses will also be presented. Extended bed rest, which is an analog for microgravity, can result in gray matter changes and potentially in microstructural white matter changes in areas that are important for neuromotor behavior and cognition. These changes did not recover at two weeks post bed rest. These results have significant public health implications, and will also aid in interpretation of our future data obtained pre and post spaceflight. Whether the effects of bed rest wear off at longer times post bed rest, and if they are associated with behavior are important questions that warrant further research.

Koppelmans, V.↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

Prisk, Gordon Kim↗

Applicability of the Nasa Galactic Cosmic Ray Simulator for Mice, Rats, and Minipigs

Space radiation poses multiple health risks to astronauts including cancer, cardiovascular disease, and damage to the central nervous system. Radiation from galactic cosmic rays (GCR) is the main source of these risks for missions beyond low Earth orbit to the moon and beyond. A galactic cosmic ray simulator (GCRsim) was developed at the NASA Space Radiation Laboratory to better understand and mitigate these risks by simulating the complex mixed field of the GCR environment at a ground-based facility. The GCRsim delivers a radiation field to cell and animal models in a laboratory setting that is comparable to the shielded radiation environment within internal organs of astronauts in deep space missions. Previous verification studies using Monte Carlo simulations with mouse (Digimouse) and rat (Digirat) digital phantoms showed that the GCRsim yields acceptable dose homogeneity within the internal organs of these animals. Spectral characteristics of the intended space radiation environment are also accurately reproduced at radiosensitive sites in both phantoms. In this work, similar Monte Carlo simulations were performed in a minipig model (Digipig) to show the applicability and limitations of the current GCRsim for larger animal model systems. The results showed dose homogeneity in internal organs of the three animal models with GCRsim irradiation. While slightly lower average doses were seen in the minipig compared to the external beam dose, the individual voxel doses in slices of the phantoms were found to be within 6%–8% of the average voxel dose, establishing that the GCRsim can still provide a relatively homogeneous irradiation within larger animals. Furthermore, simulated dose and fluence spectral results across the relevant linear energy transfer (LET) range agreed well with the reference field in the most relevant regions of the spectra, further verifying that the GCRsim beam represents the reference field in larger animals.

Galactic cosmic rays↗