Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VoR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of spaceflight on ocular counterrolling and the spatial orientation of the vestibular system

We recorded the horizontal (yaw), vertical (pitch), and torsional (roll) eye movements of two rhesus monkeys with scleral search coils before and after the COSMOS Biosatellite 2229 Flight. The aim was to determine effects of adaptation to microgravity on the vestibulo-ocular reflex (VOR). The animals flew for 11 days. The first postflight tests were 22 h and 55 h after landing, and testing extended for 11 days after reentry. There were four significant effects of spaceflight on functions related to spatial orientation: (1) Compensatory ocular counterrolling (OCR) was reduced by about 70% for static and dynamic head tilts with regard to gravity. The reduction in OCR persisted in the two animals throughout postflight testing. (2) The gain of the torsional component of the angular VOR (roll VOR) was decreased by 15% and 50% in the two animals over the same period. (3) An up-down asymmetry of nystagmus, present in the two monkeys before flight was reduced after exposure to microgravity. (4) The spatial orientation of velocity storage was shifted in the one monkey that could be tested soon after flight. Before flight, the yaw axis eigenvector of optokinetic afternystagmus was close to gravity when the animal was upright or tilted. After flight, the yaw orientation vector was shifted toward the body yaw axis. By 7 days after recovery, it had reverted to a gravitational orientation. We postulate that spaceflight causes changes in the vestibular system which reflect adaptation of spatial orientation from a gravitational to a body frame of reference. These changes are likely to play a role in the postural, locomotor, and gaze instability demonstrated on reentry after spaceflight.

Non-NASA Center↗

Contribution of irregular semicircular canal afferents to the horizontal vestibuloocular response during constant velocity rotation

1. The effects of constant anodal currents (100 microA) delivered bilaterally to both labyrinths on the horizontal vestibuloocular response (VOR) were studied in squirrel monkeys during steps of angular velocity in the dark. We report that bilateral anodal currents decreased eye velocity approximately 30-50% during the period of galvanic stimulation without a change in the time constant of VOR. The decrease in eye velocity, present during steps of angular velocity, was not observed during sinusoidal head rotation at 0.2, 0.5, and 1 Hz. The results suggest that responses from irregular vestibular afferents influence VOR amplitude during constant velocity rotation.

NASA Discipline Neuroscience↗

Three dimensional eye movements of squirrel monkeys following postrotatory tilt

Three-dimensional squirrel monkey eye movements were recorded during and immediately following rotation around an earth-vertical yaw axis (160 degrees/s steady state, 100 degrees/s2 acceleration and deceleration). To study interactions between the horizontal angular vestibulo-ocular reflex (VOR) and head orientation, postrotatory VOR alignment was changed relative to gravity by tilting the head out of the horizontal plane (pitch or roll tilt between 15 degrees and 90 degrees) immediately after cessation of motion. Results showed that in addition to post rotatory horizontal nystagmus, vertical nystagmus followed tilts to the left or right (roll), and torsional nystagmus followed forward or backward (pitch) tilts. When the time course and spatial orientation of eye velocity were considered in three dimensions, the axis of eye rotation always shifted toward alignment with gravity, and the postrotatory horizontal VOR decay was accelerated by the tilts. These phenomena may reflect a neural process that resolves the sensory conflict induced by this postrotatory tilt paradigm.

NASA Program Space Physiology and Countermeasures↗

Binocular Coordination of the Human Vestibulo-Ocular Reflex during Off-axis Pitch Rotation

Head movements in the sagittal pitch plane typically involve off-axis rotation requiring both vertical and horizontal vergence ocular reflexes to compensate for angular and translational motion relative to visual targets of interest. The purpose of this study was to compare passive pitch VOR responses during rotation about an Earth-vertical axis (canal only cues) with off-axis rotation (canal and otolith cues). Methods. Eleven human subjects were oscillated sinusoidally at 0.13, 0.3 and 0.56 Hz while lying left-side down with the interaural axis either aligned with the axis of rotation or offset by 50 cm. In a second set of measurements, twelve subjects were also tested during sinusoidally varying centrifugation over the same frequency range. The modulation of vertical and horizontal vergence ocular responses was measured with a binocular videography system. Results. Off-axis pitch rotation enhanced the vertical VOR at lower frequencies and enhanced the vergence VOR at higher frequencies. During sinusoidally varying centrifugation, the opposite trend was observed for vergence, with both vertical and vergence vestibulo-ocular reflexes being suppressed at the highest frequency. Discussion. These differential effects of off-axis rotation over the 0.13 to 0.56 Hz range are consistent with the hypothesis that otolith-ocular reflexes are segregated in part on the basis of stimulus frequency. At the lower frequencies, tilt otolith-ocular responses compensate for declining canal input. At higher frequencies, translational otolith-ocular reflexes compensate for declining visual contributions to the kinematic demands required for fixating near targets.

Wood, S. J.↗

Effect of Target Location on Dynamic Visual Acuity During Passive Horizontal Rotation

The vestibulo-ocular reflex (VOR) generates eye rotation to compensate for potential retinal slip in the specific plane of head movement. Dynamic visual acuity (DVA) has been utilized as a functional measure of the VOR. The purpose of this study was to examine changes in accuracy and reaction time when performing a DVA task with targets offset from the plane of rotation, e.g. offset vertically during horizontal rotation. Visual acuity was measured in 12 healthy subjects as they moved a hand-held joystick to indicate the orientation of a computer-generated Landolt C "as quickly and accurately as possible." Acuity thresholds were established with optotypes presented centrally on a wall-mounted LCD screen at 1.3 m distance, first without motion (static condition) and then while oscillating at 0.8 Hz (DVA, peak velocity 60 deg/s). The effect of target location was then measured during horizontal rotation with the optotypes randomly presented in one of nine different locations on the screen (offset up to 10 deg). The optotype size (logMar 0, 0.2 or 0.4, corresponding to Snellen range 20/20 to 20/50) and presentation duration (150, 300 and 450 ms) were counter-balanced across five trials, each utilizing horizontal rotation at 0.8 Hz. Dynamic acuity was reduced relative to static acuity in 7 of 12 subjects by one step size. During the random target trials, both accuracy and reaction time improved proportional to optotype size. Accuracy and reaction time also improved between 150 ms and 300 ms presentation durations. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements when acquiring vertical targets. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of motion. Both reaction time and accuracy are functionally relevant DVA parameters of VOR function.

Appelbaum, Meghan↗

Dynamic Visual Acuity: a Functionally Relevant Research Tool

Coordinated movements between the eyes and head are required to maintain a stable retinal image during head and body motion. The vestibulo-ocular reflex (VOR) plays a significant role in this gaze control system that functions well for most daily activities. However, certain environmental conditions or interruptions in normal VOR function can lead to inadequate ocular compensation, resulting in oscillopsia, or blurred vision. It is therefore possible to use acuity to determine when the environmental conditions, VOR function, or the combination of the two is not conductive for maintaining clear vision. Over several years we have designed and tested several tests of dynamic visual acuity (DVA). Early tests used the difference between standing and walking acuity to assess decrements in the gaze stabilization system after spaceflight. Supporting ground-based studies measured the responses from patients with bilateral vestibular dysfunction and explored the effects of visual target viewing distance and gait cycle events on walking acuity. Results from these studies show that DVA is affected by spaceflight, is degraded in patients with vestibular dysfunction, changes with target distance, and is not consistent across the gait cycle. We have recently expanded our research to include studies in which seated subjects are translated or rotated passively. Preliminary results from this work indicate that gaze stabilization ability may differ between similar active and passive conditions, may change with age, and can be affected by the location of the visual target with respect to the axis of motion. Use of DVA as a diagnostic tool is becoming more popular but the functional nature of the acuity outcome measure also makes it ideal for identifying conditions that could lead to degraded vision. By doing so, steps can be taken to alter the problematic environments to improve the man-machine interface and optimize performance.

Peters, Brian T.↗

A Sparse Matrix Approach for Simultaneous Quantification of Nystagmus and Saccade

The vestibulo-ocular reflex (VOR) consists of two intermingled non-linear subsystems; namely, nystagmus and saccade. Typically, nystagmus is analysed using a single sufficiently long signal or a concatenation of them. Saccade information is not analysed and discarded due to insufficient data length to provide consistent and minimum variance estimates. This paper presents a novel sparse matrix approach to system identification of the VOR. It allows for the simultaneous estimation of both nystagmus and saccade signals. We show via simulation of the VOR that our technique provides consistent and unbiased estimates in the presence of output additive noise.

Kukreja, Sunil L.↗

Next Generation Life Support Project Status

Next Generation Life Support (NGLS) is one of several technology development projects sponsored by NASA s Game Changing Development Program. The NGLS Project is developing life support technologies (including water recovery and space suit life support technologies) needed for humans to live and work productively in space. NGLS has three project tasks: Variable Oxygen Regulator (VOR), Rapid Cycle Amine (RCA) swing bed, and Alternative Water Processor (AWP). The RCA swing bed and VOR tasks are directed at key technology needs for the Portable Life Support System (PLSS) for an Advanced Extravehicular Mobility Unit, with focus on test article development and integrated testing in an Advanced PLSS in cooperation with the Advanced Extra Vehicular Activity (EVA) Project. An RCA swing-bed provides integrated carbon dioxide removal and humidity control that can be regenerated in real time during an EVA. The VOR technology will significantly increase the number of pressure settings available to the space suit. Current space suit pressure regulators are limited to only two settings whereas the adjustability of the advanced regulator will be nearly continuous. The AWP effort, based on natural biological processes and membrane-based secondary treatment, will result in the development of a system capable of recycling wastewater from sources expected in future exploration missions, including hygiene and laundry water. This paper will provide a status of technology development activities and future plans.

Barta, Daniel J.↗

Stroboscopic Goggles as a Countermeasure for Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing, the vestibular system and the central nervous system, responsible for coordinating head and eye movements via the vestibulo-occular reflex (VOR), are adapted to microgravity and must re-adapt to the Earth's gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. These effects are caused by retinal slip, or the inability to keep an image focused on their retina, which is thought to drive motion sickness symptoms experienced upon landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Peters et al. (2011) find that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. Previously, the use of stroboscopic goggles has shown to be effective in minimizing motion sickness symptoms due to retinal slip (Reschke et al. 2007). In this study, we simulated the decrement in DVA caused by sensorimotor re-adaptation by using minifying lenses and then testing the efficacy of stroboscopic goggles in preventing retinal slip and improving DVA. Dynamic visual acuity is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is motor-driven and oscillates vertically at 2 Hz with a vertical displacement of +/- 2 cm to simulate the vertical translations that occur while walking. As the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous responses of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. We found that healthy subjects (n=20) have a significantly impaired DVA while wearing the minifying lenses, demonstrating that the VOR is in an adaptive state and retinal slip is occurring. When subjects' acuity was tested wearing the stroboscopic goggles with the minifying lenses, there was no significant difference in their DVA compared to their baseline DVA. This suggests that stroboscopic goggles are preventing retinal slip and would function as an efficient countermeasure for VOR adaptations and thus help mitigate landing sickness symptoms experienced by long-duration crewmembers. These goggles might also be used to counter blurred vision (caused by retinal slip) experienced by crewmembers during launch where the vehicle vibrations are greatest. The stroboscopic effect could be built into a section of their head mounted displays on the visor of their helmets to be used in these high vibration situation if a mission critical task is necessary.

Rosenberg, M. J. F.↗

Broadcast control of air traffic

The proceedings of a conference on the Omega navigation system are presented. Three significant low frequency/very low frequency possibilities are considered as follows: (1) use of Worldwide (WW) Omega, (2) use of an Omega-like system optimized for aviation in the continental United States, (3) a mix use of WW Omega and Vor, U.S. Omega and VOR, and U.S./WW Omega. It is concluded that all possibilites can be tested with current plans for WW Omega.

Litchford, G. B.↗

Flight evaluation of advanced navigation techniques for general aviation using frequency scanning

Experiments on an automatic multisensor navigation concept are being conducted in a Cessna 402B. The test system consists of VOR, DME, and air data sensors controlled by a Hewlett Packard 9820A electronic calculator which processes the data and, by means of a four-state Kalman filter, outputs position and ground and wind velocities to a map display. Novel features which make such a system potentially low-cost include frequency-scanning operation of a single VOR receiver and a single DME transceiver and use of a shed-vortex true airspeed sensor. Results obtained during flight in a local area where six to eight DME NAVAIDS were receivable yielded better than 1/4-mile accuracy.

Jackson, C. T., Jr.↗

Loran-C flight data base

Loran-C time-difference data were collected on January 9, 1979 during a flight from Athens, Ohio to Madison VOR in Connecticut, thence to Millville VOR in New Jersey, and a landing at Atlantic City NAFEC. Portions of the return trip to Athens, Ohio were also recorded. Loran-C GRI data frames were recorded using the 99600 U. S. Northeast Loran chain stations Seneca/Nantucket (TDA) and Seneca/Carolina Beach (TDB). The GRI sequence number TDA and TDB were recorded as integer numbers, with the TD's in integer microseconds. Actual time-of-day can be determined from the data start time, plus the time per GRI and the sequence number. The low cost Loran-C receiver was used to obtain the time-difference data for each GRI. Data was recorded on digital magnetic tape and post-processed into latitude and longitude using an IBM system/370 computer.

Lilley, R. W.↗

Effects of digital altimetry on pilot workload

A series of VOR-DME instrument landing approaches was flown in the DC-9 full-workload simulator to compare pilot performance, scan behavior, and workload when using a computer-drum-pointer altimeter (CDPA) and a digital altimeter (DA). Six pilots executed two sets of instrument landing approaches, with a CDPA on one set and a DA on the other set. Pilot scanning parameters, flight performance, and subjective opinion data were evaluated. It is found that the processes of gathering information from the CDPA and the DA are different. The DA requires a higher mental workload than the CDPA for a VOR-DME type landing approach. Mental processing of altitude information after transitioning back to the attitude indicator is more evident with the DA than with the CDPA.

Harris, R. L., Sr.↗

Effects of digital altimetry on pilot workload

A series of VOR-DME instrument landing approaches was flown in the DC-9 full-workload simulator to compare pilot performance, scan behavior, and workload when using a computer-drum-pointer altimeter (CDPA) and a digital altimeter (DA). Six pilots executed two sets of instrument landing approaches, with a CDPA on one set and a DA on the other set. Pilot scanning parameters, flight performance, and subjective opinion data were evaluated. It is found that the processes of gathering information from the CDPA and the DA are different. The DA requires a higher mental workload than the CDPA for a VOR-DME type landing approach. Mental processing of altitude information after transitioning back to the attitude indicator is more evident with the DA than with the CDPA.

Harris, R. L., Sr.↗

Lack of effects of astemizole on vestibular ocular reflex, motion sickness, and cognitive performance in man

Astemizole was orally administered to 20 subjects in a randomized, double-blind design to assess the efficacy of this peripherally active antihistamine as an antimotion sickness drug possessing no central side-effects. Measures of vestibular ocular reflex (VOR) were made to evaluate the agent as a selective vestibular depressant. Following one week of orally administered astemizole (30 mg daily), a Staircase Profile Test, a VOR test, and a variety of tests of cognitive performance were administered. These tests revealed no statistically significant effects of astemizole. This leads to the conclusion that, although the drug probably reaches the peripheral vestibular apparatus in man by crossing the blood-vestibular barrier, a selective peripheral antihistamine (H1) action is inadequate to control motion sickness induced through cross-coupled accelerative semicircular canal stimulation in a rotating chair.

Kohl, Randall L.↗

The Chinchilla's vestibulo-ocular reflex

The horizontal vestibulo-ocular reflex (VOR) was measured and characterized in seven adult chinchillas using 0.01 to 1.0 Hz angular velocity sinusoids. Gains were less than compensatory, and were variable from day to day, but phases were highly repeatable both within and between animals. The best fitting transfer function to the average data of all animals had a dominant time constant of 7.5 sec, and an adaptation operator with a time constant of 24.0 sec. There were certain nonlinearities in the horizontal VOR of this animal, and it was difficult to elicit a robust optokinetic response. Results are discussed in relation to similar measurements in other species.

Merwin, W. H., Jr.↗

Relation between perception of vertical axis rotation and vestibulo-ocular reflex symmetry

Subjects seated in a vertical axis rotation chair controlled their rotational velocity by adjusting a potentiometer. Their goal was to null out pseudorandom rotational perturbations in order to remain perceptually stationary. Most subjects showed a slow linear drift of velocity (a constant acceleration) to one side when they were deprived of an earth-fixed visual reference. The amplitude and direction of this drift can be considered a measure of a static bias in the subject's perception of rotation. The presence of a perceptual bias is consistent with a small, constant imbalance of vestibular function which could be of either central or peripheral origin. Deviations from perfect vestibulocular reflex (VOR) symmetry are also assumed to be related to imbalances in either peripheral or central vestibular function. Researchers looked for correlations between perceptual bias and various measures of vestibular reflex symmetry that might suggest a common source for both reflective and perceptual imbalances. No correlations were found. Measurement errors could not account for these results since repeated tests on the same subjects of both perceptual bias and VOR symmetry were well correlated.

Peterka, Robert J.↗

Comparison of smooth pursuit and combined eye-head tracking in human subjects with deficient labyrinthine function

The effects of deficient labyrinthine function on smooth visual tracking with the eyes and head were investigated, using ten patients with bilateral peripheral vestibular disease and ten normal controls. Active, combined eye-head tracking (EHT) was significantly better in patients than smooth pursuit with the eyes alone, whereas normal subjects pursued equally well in both cases. Compensatory eye movements during active head rotation in darkness were always less in patients than in normal subjects. These data were used to examine current hypotheses that postulate central cancellation of the vestibulo-ocular reflex (VOR) during EHT. A model that proposes summation of an integral smooth pursuit command and VOR/compensatory eye movements is consistent with the findings. Observation of passive EHT (visual fixation of a head-fixed target during en bloc rotation) appears to indicate that in this mode parametric gain changes contribute to modulation of the VOR.

Leigh, R. J.↗