Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISCOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Towards P3HT Inkjet Printability of Sensors

Here we propose a method to inkjet print sensors using P3HT and present the data that demonstrates the printability potential of this material. Poly(3-Hexylthiophene) commonly known as P3HT is a semiconductor polymer that is usually used as a hole transporting material in the fabrication of transistors, and perovskite solar cells. There is a desire to transpose this technology to inkjet printing to ease the testing and researching of semiconductor polymers. However, there has been not success in the inkjet printability of P3HT due to the lack of key information such as viscosity and surface tension and the additional issues of using a strong solvent to dilute P3HT. In this work we propose a method to inkjet print P3HT sensors using a commercially available inkjet printer. This method is reinforced with the measurements obtained from a viscometer and surface tensiometer.

Marquez, Jesus↗

Electrospinner Upgrades for Nanofiber Production

Electrospinning is an inexpensive method for producing nanofibers, with applications in accelerator targets, air filtration, and biomedicine. This project aims to upgrade and test an existing roll-to-roll electrospinner that is economical for industrial production. Our unit cannot adjust spinneret to collector separation and thus nanofiber diameter (application dependent). The electro-spinneret channel also does not have lateral adjustment capabilities. Lastly, the viscosities of our polymers have not been quantified, which can inform future injector nozzle designs. Modeling was done with Siemens NX CAD, and viscosity was measured using a Brookfield DVE-LV viscometer. A dual scissor lift design was approved, and construction was started, along with channel modifications. Viscosity measurements of polyvinyldimethylformamide were recorded with inconsistent results. Going forward, the scissor lift and channel modifications will be evaluated with our electrospinner. Future viscosity trials must be completed in accordance with testing requirements. The optimization of electrospinner units can make nanofiber production more feasible for many industries.

Black, Niko↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Completion of Transport Property Measurements on Multiple Actinide Fluoride Mixtures

One of the missions of the US Department of Energy’s Office of Nuclear Energy (DOE-NE) Molten Salt Reactor (MSR) Campaign under the Advanced Reactor Technology program has been to experimentally measure thermophysical properties of MSR-relevent salt systems, with the intent of supporting the development of the Molten Salt Thermal Properties Database (MSTDB). This database is jointly funded by the DOE-NE Nuclear Energy Advanced Modeling and Simulation Program and the MSR Campaign. Multiple DOE national laboratories, including Oak Ridge National Laboratory (ORNL), have been conducting measurements of thermophysical properties to support MSTDB development and provide MSR developers with access to new data that has been measured using modern methodologies and more advanced sample characterization techniques. These data may either fill gaps in the database or provide updated higher quality data to replace legacy data. Researchers at ORNL have recognized significant gaps in the transport property data of actinide-bearing fluoride salt systems of MSR industry interest. Moreover, for the data present in MSTDB in this category, the uncertainty margins are generally high, leading to questionability in our current understanding of the thermophysical characterization of actinide fluoride mixtures. As such, the focus of this study has been to generate new transport property data of actinide fluoride mixtures that are of immediate interest to MSR developers. Specifically, the mixtures NaF-UF 4 (78 - 22 mol%) and NaF-KF-UF 4 (57-16.04-26.91 mol%) have been studied—NaF-UF 4 for thermal conductivity and viscosity and NaF-KF-UF 4 for viscosity. Thermal conductivity measurements have been conducted with a variable gap apparatus, whereas viscosity has been measured with a rolling ball viscometer. Methodological and calibration details are provided for both measurement processes, along with measurement system updates that have enabled easier manufacturing of components and fewer challenges associated with conducting the measurements themselves. The resultant data collected for NaF-UF 4 (78–22 mol%) and NaF-KF-UF 4 (57-16.04-26.91 mol%) have been compared with relevant mixture data within the thermophysical arm of the MSTDB (MSTDB-TP).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Viscosity and density of methanol/water mixtures at low temperatures

Viscosity and density are measured at low temperatures for three methanol/water mixtures. Viscosity is determined by a modified falling cylinder method or a calibrated viscometer. Density is determined by the volume of each mixture contained in a calibrated glass cell placed in a constant-temperature bath.

Austin, J. G.↗

High pressure pulsed capillary viscometry

An analytical and test program was conducted in order to establish the feasibility of a multichamber pulsed-capillary viscometer. The initial design incorporated a piston, ram, and seals which produced measured pulses up to 30,000 psi in the closed chamber system. Pressure pulses from one to ten milliseconds were investigated in a system volume of 1 cuin. Four test fluids: a MIL-L-7808, a 5P4E polyphenyl ether, a MIL-L-23699A, and a synthetic hydrocarbon were examined in the test pressure assembly. The pressure-viscosity coefficient and viscosity delay time were determined for the MIL-L-7808 lubricant tested.

Smith, R. L.↗

Investigations of lubricant rheology as applied to elastohydrodynamic lubrication

The pressure viscometer was modified to permit the measurement of viscosity at elevated pressures and shear stresses up to 5 x 10 to the 6th power N/sq m (720 psi). This shear stress is within a factor of three of the shear stress occurring in a sliding ehd point contact such as occurs in the ehd simulator. Viscosity data were taken on five lubricant samples, and it was found that viscous heating effects on the viscosity were predominant and not non-Newtonian behavior at the high shear stresses. The development of the infrared temperature measuring technique for the ehd simulator was completed, and temperature data for a set of operating conditions and one lubricant are reported. The numerical analysis of the behavior of nonlinear lubricants in the lubrication of rollers is reported.

Carlson, S.↗

Pressure-viscosity measurements for several lubricants to 5.5 x 10 to the 8th power Newtons per square meter (8 x 10 to the 4th psi) and 149 C (300 F)

A capillary viscometer was used to measure viscosity as a function of pressure, temperature, and shear stress for a number of lubricants. The conditions under which the measurements were made are specified. The results obtained for each material are analyzed. It was determined that all pressure-viscosity coefficients decreased with increasing temperature. Data from other techniques such as optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry were compared with the results obtained.

Jones, W. R.↗

Pressure-viscosity measurements for several lubricants to 550 meganewtons per square meter /80,000 PSI/ and 149 C /300 F/

The viscosities of a number of liquid lubricants and lubricant formulations, determined as function of pressure, temperature, and shear stress by means of a high-pressure capillary viscometer, are reviewed. Where possible, these results are compared with those obtained by other techniques (optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry).

Jones, W. R., Jr.↗

U.S. National Congress of Applied Mechanics, 7th, University of Colorado, Boulder, Colo., June 3-7, 1974, Proceedings

A series of experimental, theoretical, and review papers dealing with various aspects of applied mechanics, including structural analysis, mathematical methods, and fluid dynamics. Some of the topics covered are: the direct formulation of two-dimensional mechanics problems, the mechanical aspects of athletics, Laplace's tidal equations, cochlear mechanics, dynamic constitutive equations, optical techniques for the determination of displacement and strain fields, chemical and biochemical problems involving nonlinear diffusion processes, thermal stresses, the rotating rod viscometer, finite-element methods in plasticity, ships of minimum resistance, and wide-band random vibration of structures. Individual items are announced in this issue.

Source record↗

Measurement of viscosity and elasticity of lubricants at high pressures

The oscillating quartz crystal viscometer has been used to investigate possible viscoelastic behavior in synthetic lubricating fluids and to obtain viscosity-pressure-temperature data for these fluids at temperatures to 300 F and pressures to 40,000 psig. The effect of pressure and temperature on the density of the test fluids was measured concurrently with the viscosity measurements. Viscoelastic behavior of one fluid, di-(2-ethylhexyl) sebacate, was observed over a range of pressures. These data were used to compute the reduced shear elastic (storage) modulus and reduced loss modulus for this fluid at atmospheric pressure and 100 F as functions of reduced frequency.

Rein, R. G., Jr.↗

Rheology of composite solid propellants during motor casting

Results of casting studies are reviewed so as to define the viscosity criteria insuring the fabrication of defect-free grains. The rheology of uncured propellants is analyzed showing that a realistic assessment of a propellant's flow properties must include measurement of viscosity as a function of shear stress and time after curing agent. Methods for measuring propellant viscosity are discussed, with particular attention given to the Haake-Rotovisko rotational viscometer. The effects of propellant compositional and processing variables on apparent viscosity are examined, as are results relating rheological behavior to grain defect formation during casting.

Klager, K.↗

Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

Saaski, E. W.↗

Surface temperatures and glassy state investigations in tribology

Measurements were made of the limiting shear stress for two naphthenic oils of differing molecular weight and three blends of the lower molecular weight oil and polymers of differing molecular weight. All reached the same limiting shear stress for the same temperature and pressure; although the polymer solutions reduced the limiting shear stress by about fifteen percent. A falling body viscometer was constructed to operate to 230 C and to 0.6 GPa and another was constructed to extend the pressure range to 1.1 GPa. A concentrated contact simulator was developed which allows recording of the traction force while the slide-roll ratio is continuously varied and the rolling speed is maintained essentially constant. Measurement of lubricant minimum film thickness of elliptical EHD contacts of various aspect ratios were made by optical interferometry. The experimental data were thirty percent greater than that predicted by the Hamrock and Dowson model. Preliminary development of the application of a scanning infrared radiation system to a tribological system was completed.

Bair, S.↗