Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VANES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cooling Strategies for Vane Leading Edges in a Syngas Environment Including Effects of Deposition and Turbulence

The Department of Energy has goals to move land based gas turbine systems to alternate fuels including coal derived synthetic gas and hydrogen. Coal is the most abundant energy resource in the US and in the world and it is economically advantageous to develop power systems which can use coal. Integrated gasification combined cycles are (IGCC) expected to allow the clean use of coal derived fuels while improving the ability to capture and sequester carbon dioxide. These cycles will need to maintain or increase turbine entry temperatures to develop competitive efficiencies. The use of coal derived syngas introduces a range of potential contaminants into the hot section of the gas turbine including sulfur, iron, calcium, and various alkali metals. Depending on the effectiveness of the gas clean up processes, there exists significant likelihood that the remaining materials will become molten in the combustion process and potentially deposit on downstream turbine surfaces. Past evidence suggests that deposition will be a strong function of increasing temperature. Currently, even with the best gas cleanup processes a small level of particulate matter in the syngas is expected. Consequently, particulate deposition is expected to be an important consideration in the design of turbine components. The leading edge region of first stage vanes most often have higher deposition rates than other areas due to strong fluid acceleration and streamline curvature in the vicinity of the surface. This region remains one of the most difficult areas in a turbine nozzle to cool due to high inlet temperatures and only a small pressure ratio for cooling. The leading edge of a vane often has relatively high heat transfer coefficients and is often cooled using showerhead film cooling arrays. The throat of the first stage nozzle is another area where deposition potentially has a strongly adverse effect on turbine performance as this region meters the turbine inlet flow. Based on roughness levels found on in service vanes (Bons, et al., 2001, up to 300 microns) flow blockage in first stage turbine nozzles can easily reach 1 to 2 percent in conventional turbines. Deposition levels in syngas fueled gas turbines are expected to be even more problematic. The likelihood of significant deposition to the leading edge of vanes in a syngas environment indicates the need to examine this effect on the leading edge cooling problem. It is critical to understand the influence of leading edge geometry and turbulence on deposition rates for both internally and showerhead cooled leading edge regions. The expected level of deposition in a vane stagnation region not only significantly changes the heat transfer problem but also suggests that cooling arrays may clog. Addressing the cooling issue suggests a need to better understand stagnation region heat transfer with realistic roughness as well as the other variables affecting transport near the leading edge. Also, the question of whether leading edge regions can be cooled internally with modern cooling approaches should also be raised, thus avoiding the clogging issue. Addressing deposition in the pressure side throat region of the nozzle is another critical issue for this environment. Issues such as examining the protective effect of slot and full coverage discrete-hole film cooling on limiting deposition as well as the influence of roughness and turbulence on effectiveness should be raised. The objective of this present study is to address these technical challenges to help enable the development of high efficiency syngas tolerant gas turbine engines.

01 COAL, LIGNITE, AND PEAT↗

An adverse effect of film cooling on the suction surface of a turbine vane

Film-cooling-air ejection from the suction surface of a turbine vane was investigated. This investigation was conducted in a four-vane cascade on a J75 size turbine vane which had a row of holes near the leading edge. The experimental data are presented. It was found that a small amount of film-cooling air has a detrimental effect on the downstream vane wall cooling effectiveness. It was also shown that the presence of the film-cooling holes, without blowing, also cause an increase in vane wall temperatures. These results came from an increase in the gas-side heat transfer coefficient that was apparently caused by a laminar or transitional boundary layer becoming transitional or turbulent.

Gladden, H. J.↗

Comparison of cooling effectiveness of turbine vanes with and without film cooling

The cooling effectiveness of three film-cooled vanes were compared to the cooling effectiveness of two non-film-cooled vanes. The comparison indicated that, for the vane configurations and test conditions examined, film cooling had an adverse effect near the suction-surface trailing edge of the vanes. Film cooling was found to be beneficial on the pressure surface of the vanes.

Yeh, F. C.↗

Fast response vanes for sensing flow patterns in helicopter rotor environment

Wind tunnel experiments were conducted on four small-scale flow-direction vanes for the determination of aerodynamic response. The tests were further extended to include a standard sized low-inertia vane currently employed in aircraft flight testing. The four test vanes had different aspect ratios and were about 35 percent of the surface area of the standard vane. The test results indicate satisfactory damping and frequency response for all vanes tested and compare favorably with the standard design.

Barna, P. S.↗

Aerodynamic performance of a ceramic-coated core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a core turbine vane with a ceramic coating was investigated experimentally in a two-dimensional cascade of 10 vanes. The vane was first tested with a rough coating and then retested after the coating had been smoothed. The test fluid was atmospheric air. The cascade tests covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey results and overall performance in terms of flow angle, weight flow, and kinetic energy loss. The performance of the ceramic-coated vanes is compared with the performance of an uncoated vane having a similar profile.

Stabe, R. G.↗

Effects of long-chord acoustically treated stator vanes on fan noise. 1: Effect of long chord (taped stator)

A set of long-chord stator vanes was designed to replace the vanes in an existing fan stage. The long vanes consisted of a turning section and axial extension pieces, both of which incorporated acoustic damping material. The acoustic damping material was made inactive for these tests by covering with metal tape, and the stator vanes were tested in three length configurations. Compared to the values for the original stage, broadband noise was reduced in the middle to high frequencies with the long stator vanes, but a broadband noise increase was observed at the low frequencies. No change was observed in the blade passage tone, but some aft end reduction in the overtones was observed.

Dittmar, J. H.↗

Effects of long-chord acoustically treated stator vanes on fan noise. 2: Effect of acoustical treatment

A set of long chord stator vanes was designed to replace the vanes in an existing fan stage. The long chord stator vanes consisted of a turning section and axial extension pieces, all of which incorporated acoustic damping material. The long chord stator vanes were tested in two lengths, with the long version giving more noise reduction than the short, primarily because of the additional lining material. The noise reduction achieved with the acoustically treated long chord stator vanes was compared with the reduction achieved by an acoustically treated exhaust splitter. The long chord stator was at least as good as the splitter as a method for incorporating acoustic lining material. In addition, comparing an acoustic three ring inlet and an acoustic wall-only inlet discloses that the wall-only inlet could be used in an engine where the noise reduction requirements are not too stringent.

Dittmar, J. H.↗

Effect of endwall cooling on secondary flows in turbine stator vanes

The effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a core turbine stator vane was determined. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects were obtained. Two endwall cooling configurations were tested. In the first configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In the second configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented towards the vane pressure stator. In both cases the stator vanes were solid and uncooled so that the effect of endwall cooling was obtained directly. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows at the design, mean-radius, critical velocity ratio of 0.778. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator.

Goldman, L. J.↗

Effect of endwall cooling on secondary flows in turbine stator vanes

An experimental investigation was performed to determine the effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a coreturbine stator vane. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects could be obtained. Two endwall cooling configurations were tested. In the first configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In the second configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented toward the vane pressure surface. In both cases the stator vanes were solid and uncooled so that the effect of endwall cooling could be obtained directly. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows at the design, mean-radius, critical velocity ratio of 0.778. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator. Comparisons were made between the two cooled-endwall configurations and with the results obtained previously for solid endwalls.

Goldman, L. J.↗

Effect of cooling-hole geometry on aerodynamic performance of a film-cooled turbine vane tested with cold air in a two-dimensional cascade

The effect of the orientation and cooling-hole size on turbine-vane aerodynamic losses was evaluated. The contribution of individual vane regions to the overall effect was also investigated. Test configurations were based upon a representative configuration having 45 spanwise rows of holes spaced about the entire vane profile. Nominal hole diameters of 0.0254 and 0.0356 cm and nominal hole orientations of 35 deg, 45 deg, and 55 deg from the local vane surface and 0 deg, 45 deg, and 90 deg from the main-stream flow direction were investigated. Flow conditions and aerodynamic losses were determined by vane-exit surveys of total pressure, static pressure, and flow angle.

Kline, J. F.↗

Use of leaning vanes in a two stage fan

The use of leaning vanes for tone noise reduction was examined in terms of their application in a typical two-stage high pressure ratio fan. In particular for stages designed with outlet guide vanes and zero swirl between stages, leaning the vanes of the first stage stator was studied, since increasing the number of vanes and the gap between stages do not provide the desired advantage. It was shown that noise reduction at higher harmonics of blade passing frequency can be obtained by leaning the vanes.

Rao, G. V. R.↗

Design, durability and low cost processing technology for composite fan exit guide vanes

A program was conducted to design, fabricate and test a durable, low cost, lightweight composite fan exit guide vane for high bypass ratio gas turbine engine application. Eight candidate material/design combinations were evaluated by NASTRAN finite element analysis. Four of these candidate systems were selected for composite vane fabrication by two vendors. A core and shell vane design was chosen in which the unidirectional graphite core fiber was the same for all candidates. The shell material, fiber orientation and ply configuration were varied. Material tests were performed on raw material and composite specimens to establish specification requirements. Composite vanes were nondestructively inspected and subsequently fatigue tested in both dry and 'wet' conditions. The program provided relevant data with respect to design analysis, materials properties, inspection standards, improved durability, weight benefits and part price of the composite fan exit guide vane.

Blecherman, S. S.↗

Investigation of Power Requirements for Ice Prevention and Cyclical De-Icing of Inlet Guide Vanes with Internal Electric Heaters

An investigation was conducted to determine the electric power requirements necessary for ice protection of inlet guide vanes by continuous heating and by cyclical de-icing. Data are presented to show the effect of ambient-air temperature, liquid-water content, air velocity, heat-on period, and cycle times on the power requirements for these two methods of ice protection. The results showed that for a hypothetical engine using 28 inlet guide vanes under similar icing conditions, cyclical de-icing can provide a total power saving as high as 79 percent over that required for continuous heating. Heat-on periods in the order of 10 seconds with a cycle ratio of about 1:7 resulted in the best over-all performance with respect to total power requirements and aerodynamic losses during the heat-off period. Power requirements reported herein may be reduced by as much as 25 percent by achieving a more uniform surface-temperature distribution. A parameter in terms of engine mass flow, vane size, vane surface temperature, and the icing conditions ahead of the inlet guide vanes.was developed by which an extension of the experimental data to icing conditions and inlet guide vanes, other than those investigated was possible.

VonGlahn, Uwe↗

Aerodynamic performance of high turning core turbine vanes in a two dimensional cascade

Experimental and theoretical aerodynamic performance data are presented for four uncooled high turning core turbine vanes with exit angles of 74.9, 75.0, 77.5, and 79.6 degrees in a two dimensional cascade. Data for a more conservative 67.0 degree vane are included for comparison. Correction of the experimental aftermix kinetic energy losses to a common 0.100 centimeter trailing edge thickness yields a linear trend of increased loss from 0.020 to 0.025 as the vane exit angle increases from 67.0 to 79.6 degrees. The theoretical losses show a similar trend. The experimental and theoretical vane surface velocity distributions generally agree within approximately five percent, although the suction surface theoretical velocities are generally higher than the experimental velocities as the vane exit angle increases.

Schwab, J. R.↗

Aerodynamic performance of high turning core turbine vanes in a two-dimensional cascade

Experimental and theoretical aerodynamic performance data are presented for four uncooled high turning core turbine vanes with exit angles of 74.9, 75.0, 77.5, and 79.6 degrees in a two-dimensional cascade. Data for a more conservative 67.0 degree vane are included for comparison. Corection of the experimental aftermix kinetic energy losses to a common 0.100 centimeter trailing edge thickness yields a linear trend of increased loss from 0.020 to 0.025 as the vane exit angle increases from 67.0 to 79.6 degrees. The theoretical losses show a similar trend. The experimental and theoretical vane surface velocity distributions generally agree within approximately five percent, although the suction surface theoretical velocities are generally higher than the experimental velocities as the vane exit angle increases.

Schwab, J. R.↗

Two-dimensional wake characteristics of inlet vanes for open-circuit wind tunnels

This paper summarizes the near-field flow characteristics measured downstream of a half-scale two-dimensional wind-tunnel model of the inlet vanes designed for the National Full-Scale Facilities Complex at NASA Ames Research Center. Variations on this baseline were tested to determine how the downstream flow field is affected. Evaluations of the various configurations were made by the use of hot-wire surveys across the flow-field. These traverses yielded the properties of total pressure, boundary layers, and turbulence in the wake of the vanes. It was found that large variations in the flow field characteristics downstream of the vanes are achieved by the use of various arrangements of splitter vanes, vortex generators, screens, tail extensions, and honeycomb. Separation on the boat-tails of the vanes can be controlled and turbulence reduced by suitable combinations of screens or honeycomb or both. The penalties associated with each modification in terms of increased pressure loss are also presented.

Dudley, M. R.↗

Wind tunnel turning vanes of modern design

Rehabilitation of the Altitude Wind Tunnel includes the need for new corner turning vanes to match its upgraded performance. The design and experimental performance results from a 0.1-full scale model of the highest speed corner (M = 0.35) are presented and discussed along with some two dimensional inviscid analyses of two vaned corners. With a vane designed by an inverse two dimensional technique, the overall corner loss was about 12% of the inlet dynamic pressure of which about 4% was caused by vane skin friction. Comparable values with a conventionally designed circular arc vane were about 14% overall with about 7% due to skin friction.

Gelder, T. F.↗

Static internal performance of a single-engine onaxisymmetric-nozzle vaned-thrust-reverser design with thrust modulation capabilities

An investigation has been conducted at wind-off conditions in the stati-test facility of the Langley 16-Foot Transonic Tunnel. The tests were conducted on a single-engine reverser configuration with partial and full reverse-thrust modulation capabilities. The reverser design had four ports with equal areas. These ports were angled outboard 30 deg from the vertical impart of a splay angle to the reverse exhaust flow. This splaying of reverser flow was intended to prevent impingement of exhaust flow on empennage surfaces and to help avoid inlet reingestion of exhaust gas when the reverser is integrated into an actual airplane configuration. External vane boxes were located directly over each of the four ports to provide variation of reverser efflux angle from 140 deg to 26 deg (measured forward from the horizontal reference axis). The reverser model was tested with both a butterfly-type inner door and an internal slider door to provide area control for each individual port. In addition, main nozzle throat area and vector angle were varied to examine various methods of modulating thrust levels. Other model variables included vane box configuration (four or six vanes per box), orientation of external vane boxes with respect to internal port walls (splay angle shims), and vane box sideplates. Nozzle pressure ratio was varied from 2.0 approximately 7.0.

Leavitt, L. D.↗