Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasonic Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development and Certification of Ultrasonic Background Noise Test (UBNT) System for use on the International Space Station (ISS)

As a next step in the development and implementation of an on-board leak detection and localization system on the International Space Station (ISS), there is a documented need to obtain measurements of the ultrasonic background noise levels that exist within the ISS. This need is documented in the ISS Integrated Risk Management System (IRMA), Watch Item #4669. To address this, scientists and engineers from the Langley Research Center (LaRC) and the Johnson Space Center (JSC), proposed to the NASA Engineering and Safety Center (NESC) and the ISS Vehicle Office a joint assessment to develop a flight package as a Station Development Test Objective (SDTO) that would perform ultrasonic background noise measurements within the United States (US) controlled ISS structure. This document contains the results of the assessment

Prosser, William H.↗

Ultrasonic water column probe speeds up testing of welds

Ultrasonic device consisting of a coaxial rod and transducer enclosed in a cylindrical probe which is filled with deionized or distilled water speeds up the testing of welds. Rubber diaphragm is molded to produce the desired test beam angle.

Hoop, J. M.↗

Analytical Ultrasonics in Materials Research and Testing

Research results in analytical ultrasonics for characterizing structural materials from metals and ceramics to composites are presented. General topics covered by the conference included: status and advances in analytical ultrasonics for characterizing material microstructures and mechanical properties; status and prospects for ultrasonic measurements of microdamage, degradation, and underlying morphological factors; status and problems in precision measurements of frequency-dependent velocity and attenuation for materials analysis; procedures and requirements for automated, digital signal acquisition, processing, analysis, and interpretation; incentives for analytical ultrasonics in materials research and materials processing, testing, and inspection; and examples of progress in ultrasonics for interrelating microstructure, mechanical properites, and dynamic response.

Vary, A.↗

Ultrasonic Gear Steel Fatigue at NASA

Gear tooth bending fatigue life is one of the main drivers of rotorcraft gear box weight and maintenance cost. Depending on rotorcraft gearbox speed, 10,000 flight hours can easily mean reaching gear tooth bending fatigue cycles in the 10^10 cycle regime. Traditionally gear fatigue life in the 10^10 cycle regime is estimated based on empirical correction factors applied to the traditional fatigue limit of 10^7 cycles. In order to improve on this method of life prediction, enable better gear box design, and reduce gear box maintenance cost, NASA has started an ultrasonic gear steel fatigue program to quantify the 10^10 life of gear steels. Ultrasonic fatigue testing makes use of piezo electric actuators and resonance to generate stress-strain cycles at 20 kHz. The ability to test gear steals at 20 kHz reduces test time for 10^10 cycles from roughly 16 years with traditional 20 Hz testing to 6 days. In this presentation, the establishment of NASA's ultrasonic test capability, results to date, and future testing plans will be discussed.

Tallerico, Thomas F.↗

A preliminary investigation of acousto-ultrasonic NDE of metal matrix composite test specimens

Acousto-ultrasonic (AU) measurements were performed on a series of tensile specimens composed of 8 laminated layers of continuous, SiC fiber reinforced Ti-15-3 matrix. The following subject areas are covered: AU signal analysis; tensile behavior; AU and interrupted tensile tests; AU and thermally cycled specimens; AU and stiffness; and AU and specimen geometry.

Kautz, Harold E.↗

Spark ultrasonic transducer

Nondestructive testing by spark transducer induces ultrasonic pulses in materials without physical contact. High power pulse generator connected to step up transformer produces sparking between two tungsten rods and ultrasonic energy pulses in test samples placed between rods.

Hoop, J. M.↗

Fresnel lenses for ultrasonic inspection

Ultrasonic Fresnel lenses are effective focusing elements with potential applications in ultrasonic "contact" testing for defects in materials. Ultrasonic beams focused on concave lenses are used successfully with immersion transducers, for which test object is immersed in water bath. However, for large objects, objects that are already installed, objects on production lines, and objects that can be damaged by water, contact testing is more practical than immersion.

Kammerer, C. C.↗

Signal processing methodologies for an acoustic fetal heart rate monitor

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.

Pretlow, Robert A., III↗

DONAR - A computer processing system to extend ultrasonic pulse-echo testing.

A dedicated general purpose digital computer has been built on the principle of a sampled-data system to run an ultrasonic subsystem under programmed control. A most significant application is the ability to extract a signal from an interfering background. As illustrated in the paper, a 1 mm diameter transducer was used to measure the diameter of a 2.5 mm OD plastics tube with 0.4 mm wall thickness. Echoes from all four surfaces were displayed and the measurements indicated an uncertainty of less than 0.1 mm.

Lees, S.↗

Portable apparatus with CRT display for nondestructive testing of concrete by the ultrasonic pulse method

The development of methods for the nondestructive study of concrete structures is discussed. The nondestructive test procedure is based on the method of ultrasonic pulse transmission through the material. The measurements indicate that the elastic properties of concrete or other heterogeneous materials are a function of the rate of ultrasonic propagation. Diagrams of the test equipment are provided. Mathematical models are included to support the theoretical aspects.

Manta, G.↗

Ultrasonics. Volume 3 - Applications

Selection of test equipment, techniques, and methods for ultrasonic testing - programmed instruction textbook on nondestructive testing

Source record↗

Review of IRT CFD & Diffuser Study Results - February 2024 Test Entries

In February 2024, multiple test entries were conducted in the NASA Glenn Research Center Icing Research Tunnel (IRT) to collect CFD validation data, particularly near the facility heat exchanger inlet and outlet planes, measure the boundary layer characteristics in the test section, and survey the diffuser flow field. The CFD validation testing utilized ultrasonic anemometers to acquire 3-components of flow velocity at the inlet and outlet planes across a row of heat exchanger blocks. The test section boundary layer surveys used 18-inch boundary layer rakes centered on each of the four test section surfaces with pitot tubes at turntable centerline. The diffuser study included surveys at three streamwise positions within the diffuser with a 5-hole flow angularity probe at between 3 and 7 lateral locations at a given streamwise position. All IRT diffuser data were acquired with the flow angularity probe at the centerline of the test section. An ultrasonic anemometer was also used in the diffuser to survey near-wall velocity profiles.

Icing↗

Ultrasonic emission method enables testing of adhesive bonds

Detection of acoustic energy emitted by adhesive bonds subjected to tensile stresses at frequencies above sixteen kilocycles per second is used as a method for determining bond strength. This method is used in measuring adhesive bond strengths on metal honeycomb core panels.

Frank, L.↗

An approach for relating the results of quantitative nondestructive evaluation to intrinsic properties of high-performance materials

One of the most difficult problems the manufacturing community has faced during recent years has been to accurately assess the physical state of anisotropic high-performance materials by nondestructive means. In order to advance the design of ultrasonic nondestructive testing systems, a more fundamental understanding of how ultrasonic waves travel and interact within the anisotropic material is needed. The relationship between the ultrasonic and engineering parameters needs to be explored to understand their mutual dependence. One common denominator is provided by the elastic constants. The preparation of specific graphite/epoxy samples to be used in the experimental investigation of the anisotropic properties (through the measurement of the elastic stiffness constants) is discussed. Accurate measurements of these constants will depend upon knowledge of refraction effects as well as the direction of group velocity propagation. The continuing effort for the development of improved visualization techniques for physical parameters is discussed. Group velocity images are presented and discussed. In order to fully understand the relationship between the ultrasonic and the common engineering parameters, the physical interpretation of the linear elastic coefficients (the quantities that relate applied stresses to resulting strains) are discussed. This discussion builds a more intuitional understanding of how the ultrasonic parameters are related to the traditional engineering parameters.

Miller, James G.↗