Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UO2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molybdenum-UO2 cermet irradiation at 1145 K.

Two molybdenum-uranium dioxide cermet fuel pins with molybdenum clad were fission-heated in a forced-convection helium coolant for sufficient time to achieve 5.3% burnup. The cermet core contained 20 wt % of 93.2% enriched uranium dioxide. The results were as follows: there was no visible change in the appearance of the molybdenum clad during irradiation; the maximum increase in diameter of the fuel pins was 0.8%; there was no migration of uranium dioxide along grain boundaries and no evident interaction between molybdenum and uranium dioxide; and, finally, approximately 12% of the fission gas formed was released from the cermet core into the gas plenum.

Mcdonald, G.↗

The Manufacture of W-UO2 Fuel Elements for NTP Using the Hot Isostatic Pressing Consolidation Process

NTP is attractive for space exploration because: (1) Higher Isp than traditional chemical rockets (2)Shorter trip times (3) Reduced propellant mass (4) Increased payload. Lack of qualified fuel material is a key risk (cost, schedule, and performance). Development of stable fuel form is a critical path, long lead activity. Goals of this project are: Mature CERMET and Graphite based fuel materials and Develop and demonstrate critical technologies and capabilities.

Broadway, Jeramie↗

Advances in the Development of a WCl6 CVD System for Coating UO2 Powders with Tungsten

Demonstrated viability and utilization of: a) Fluidized powder bed. b) WCl6 CVD process. c) Coated spherical particles with tungsten. The highly corrosive nature of the WCl6 solid reagent limits material of construction. Indications that identifying optimized process variables with require substantial effort and will likely vary with changes in fuel requirements.

Mireles, Omar R.↗

Dopant Effects of UO2

Explore the source record for details and available documents.

Widgeon Paisner, Scarlett↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dissolution of Mechanically Mixed UO2-PuO2 and Insoluble Residue Characteristics

During the reprocessing operations of mixed oxide fuel the dissolution step plays a very important role in the attainment of an acceptable plutonium recovery yield. The importance of this step on the overall fuel cycle was recognized by many authors but was especially treated in depth by Lerch [1] and Nicholson [2].

De Regge, P.↗

Structure and Process of Managing the UO2 Dry In-Pile Fracture Test Irradiation Experiment

The management and structure of a novel research and development (R&D) project can be hard to navigate. This is especially true when it involves nuclear fuel. Familiarity with institutional safety and procedural requirements, a well defined scope, and accurate cost estimates can all help ensure successful project management from start to finish. The Dry In-Pile Fracture Test (DRIFT) experiments performed at the Transient Test Reactor Facility are an excellent example of managing an R&D project within its scope and budget constraints. The objective of the DRIFT test was to develop fracture propagation data in a manner consistent with light-water reactors to validate and improve the fracture propagation models of uranium oxide fuels in the MOOSE (Multiphysics Object-Oriented Simulation Environment)-BISON-Marmot code framework [1].

99 GENERAL AND MISCELLANEOUS↗

Electrochemical Corrosion of SIMFUEL: Effects of dissolved H2 and noble metal particles

This report describes the results from electrochemical corrosion tests that were conducted using simulated spent fuel (SIMFUEL) materials comprised of UO2 and surrogate fission products. Two SIMFUEL compositions were tested to quantify the effect of noble metal inclusions and dissolved H2 on the UO2 dissolution rate. One material consisted of UO2 with added lanthanide oxides (UO2 N) and the other consisted of UO2 with added lanthanide oxides and noble metals (UO2-H) at concentrations to simulate high burnup fuel. The electrochemical corrosion tests on the SIMFUEL materials were conducted in aqueous electrolyte solutions (pH 10) that were either saturated with air or purged with a H2/Ar gas mixture to maintain a constant dissolved H2 concentration. The results from electrochemical corrosion tests on SIMFUEL can be applied to qualitatively understand and also quantify the separate effects of water chemistry and fuel composition on the degradation behavior of the UO2 matrix. Open circuit potential (OCP) measurements on a SIMFUEL material of known composition (i.e., known fraction of NMPs at the fuel surface) immersed in a known solution chemistry (i.e., pH, Eh, [O2], [H2]) at known temperature provide qualitative insight into the degradation behavior of the UO2 matrix. If the OCP is above the threshold potential at which the oxidative dissolution of U(IV) to U(VI) occurs, the SNF is expected to degrade by oxidative processes under the experimental conditions. The net currents that are measured during potentiostatic tests, during which the surface potential of the SIMFUEL material is fixed by a potentiostat, can be used to quantify the UO2 degradation rate and optimize the rate constant values used in the Fuel Matrix Degradation Model (FMDM) for half reactions that occur on the SNF surface. Specifically, electrochemical measurements enable the estimation of the total anodic current at ECORR–which is the surface potential at which the total anodic and total cathodic currents are equal–so that the rate constant values for key reactions can be calculated. The open circuit potential measurements, potentiostatic tests, surface property measurements (scanning electron microscopy images and electrochemical impedence spectroscopy plots), and solution elemental composition analyses are being performed to update and optimize the FMDM. A case study is presented herein to show how electrochemical corrosion test results and accompanying characterization results for the UO2 N material in air-saturated solution can be used to validate the SNF surface reaction module of the FMDM. Future electrochemical tests will be conducted to provide quantitative information on the effects of NM content (burnup), H2 concentration, water chemistry, temperature, and galvanic couples with cladding and EBS alloys on UO2 degradation that can be used to improve the accuracy and functionality of the FMDM.

Thomas, Sara↗

Effect of Added Gadolinium Oxide on the Thermal Air Oxidation of Uranium Dioxide

To develop a more reliable and stable UO2-based nuclear fuel, the Pacific Northwest National Laboratory (PNNL) investigated modifying fuel with several soluble lanthanides and zirconium. This article provides the results of these studies investigating gadolinium doping at levels up to 10 mass%. The authors characterized and compared commercially- and PNNL-prepared gadolinium-doped UO2 to determine the oxygen-to-metal ratio, elemental distribution, chemical composition, physical appearance, lattice parameters, and grain structure using atomic force microscopy, scanning electron microscopy coupled with energy dispersive spectroscopy, and X-ray diffractometry. After confirming PNNL-prepared UO2 and (Gd,U)O2 were similar to commercially prepared UO2 and (Gd,U)O2, we measured the thermal behavior of these gadolinium-doped UO2 materials to air oxidation using differential scanning calorimetry and thermogravimetric analysis. Addition of gadolinium stabilized the first oxidation product U4¬O9/U3O7 and slowed the subsequent oxidation to U3O8. Comparison of our measured two-step oxidation of UO2 to U3O8 at 325°C to common gas/solid kinetic reaction models found that each oxidation step is best described as a convolution of kinetic behaviors; the gadolinium insertion into the UO2 lattice enforces a significant alteration in mechanism and oxidation rate. Noticeable changes in mechanism become apparent between 1% and 3% gadolinium content.

Uranium Dioxide, Gadolinium Oxide, Thermal Air Oxi↗

Measurement of kernel swelling and buffer densification in irradiated UCO and UO 2 TRISO fuel particles from AGR-2

The second Advanced Gas Reactor irradiation (AGR-2) featured UCO tristructural isotropic (TRISO)-coated particle fuel and, for comparison purposes, UO2 TRISO fuel. Particles from three UCO fuel compacts and one UO2 fuel compact were chosen for analysis of kernel swelling and buffer shrinkage. Both kernel swelling and buffer shrinkage are common elements of TRISO fuel performance models. More recently, the AGR program has determined that buffer shrinkage may impact the integrity of the inner pyrolytic carbon (IPyC) layer, which may impact SiC layer integrity (particularly during high-temperature heating tests). Therefore, measurements of buffer irradiation-induced shrinkage may be useful in improving existing models and developing new models that capture buffer-IPyC-SiC-fission product interactions observed in recent AGR post-irradiation examination (PIE). TRISO particles were mounted in epoxy, ground, polished, and imaged via optical microscopy in four separate iterations. Each of the four iterations revealed progressively deeper cross sections within the particles. Images collected from each iteration were analyzed for the circumferences/radii of the kernel, buffer, IPyC, and SiC. Spheres were fit to each set of measurements to generate spherical radii representative of the components of the fuel particle. From these radii, volumes were computed and compared to the as-fabricated volumes. UCO kernel swelling was similar among the three AGR-2 compacts ranging from approximately 28 to 32%. This is only slightly higher swelling than was measured in an earlier study of an AGR-1 compact. However, the burnup at which this swelling occurred in AGR-2 was lower than in AGR-1, indicating a faster swelling rate for the AGR-2 kernels for the irradiation conditions covered by these compacts. The AGR-2 UO2 kernel swelling was less, at 9.9%, comparable to other studies of UO2 kernel swelling. While AGR-2 UCO and UO2 kernels demonstrated different rates of swelling, the extent of buffer shrinkage was similar among the two fuel types, ranging from 24-28%. For comparison, a prior study showed that AGR-1 Compact 1-3-1 experienced 39% buffer shrinkage. A commonly-observed post-irradiation particle morphology is where the buffer pulls away from the IPyC (at least in some regions of the particle). Besides the possibility of the buffer degrading the IPyC when it pulls away from the IPyC, this gap is significant because it may also reduce heat transfer within the particle. Average AGR-2 buffer-IPyC gaps were similar for the UCO and UO2 particles, ranging from 22.2 to 26.0 µm. This is similar to what was measured for AGR-1 Compact 1-3-1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A NanoSIMS 50 L Investigation into Improving the Precision and Accuracy of the 235U/238U Ratio Determination by Using the Molecular 235U16O and 238U16O Secondary Ions

A NanoSIMS 50 L was used to study the relationship between the 235U/238U atomic and 235U16O/238U16O molecular uranium isotope ratios determined from a variety of uranium compounds (UO2, UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4) and silicates (NIST-610 glass and the Plesovice zircon reference materials, both containing µg/g uranium). Because there is typically a greater abundance of 235U16O+ and 238U16O+ molecular secondary ions than 235U+ and 238U+ atomic ions when uranium-bearing materials are sputtered with an oxygen primary ion beam, the goal was to understand whether use of 235U16O/238U16O has the potential for improved accuracy and precision when compared to the 235U/238U ratio. The UO2 and silicate reference materials showed the greatest potential for improved accuracy and precision through use of the 235U16O/238U16O ratio as compared to the 235U/238U ratio. For the UO2, which was investigated at a variety of primary beam currents, and the silicate reference materials, which were only investigated using a single primary beam current, this improvement was especially pronounced at low 235U+ count rates. In contrast, comparison of the 235U16O/238U16O ratio versus the 235U/238U ratio from the other uranium compounds clearly indicates that the 235U16O/238U16O ratio results in worse precision and accuracy. This behavior is based on the observation that the atomic (235U+ and 238U+) to molecular (235U16O+ and 238U16O+) secondary ion production rates remain internally consistent within the UO2 and silicate reference materials, whereas it is highly variable in the other uranium compounds. Efforts to understand the origin of this behavior suggest that irregular sample surface topography, and/or molecular interferences arising from the manner in which the UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4 were prepared, may be a major contributing factor to the inconsistent relationship between the observed atomic and molecular secondary ion yields. Overall, the results suggest that for certain bulk compositions, use of the 235U16O/238U16O may be a viable approach to improving the precision and accuracy in situations where a relatively low 235U+ count rate is expected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗