Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASONOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-Dose, Single-Fraction Irradiation Rapidly Reduces Tumor Vasculature and Perfusion in a Xenograft Model of Neuroblastoma

Purpose: To characterize the effects of high-dose radiation therapy (HDRT) on neuroblastoma tumor vasculature, including the endothelial cell (EC)–pericyte interaction as a potential target for combined treatment with antiangiogenic agents. Methods and Materials: The vascular effects of radiation therapy were examined in a xenograft model of high-risk neuroblastoma. In vivo 3-dimensional contrast-enhanced ultrasonography (3D-CEUS) imaging and immunohistochemistry (IHC) were performed. Results: HDRT significantly reduced tumor blood volume 6 hours after irradiation compared with the lower doses used in conventionally fractionated radiation. There was a 63% decrease in tumor blood volume after 12-Gy radiation compared with a 24% decrease after 2 Gy. Analysis of tumor vasculature by lectin angiography showed a significant loss of small vessel ends at 6 hours. IHC revealed a significant loss of ECs at 6 and 72 hours after HDRT, with an accompanying loss of immature and mature pericytes at 72 hours. Conclusions: HDRT affects tumor vasculature in a manner not observed at lower doses. The main observation was an early reduction in tumor perfusion resulting from a reduction of small vessel ends with a corresponding loss of endothelial cells and pericytes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Edema and Seed Displacements Affect Intraoperative Permanent Prostate Brachytherapy Dosimetry

Purpose: We sought to identify the intraoperative displacement patterns of seeds and to evaluate the correlation of intraoperative dosimetry with day 30 for permanent prostate brachytherapy. Methods and Materials: We analyzed the data from 699 patients. Intraoperative dosimetry was acquired using transrectal ultrasonography (TRUS) and C-arm cone beam computed tomography (CBCT). Intraoperative dosimetry (minimal dose to 40%-95% of the volume [D{sub 40}-D{sub 95}]) was compared with the day 30 dosimetry for both modalities. An additional edema-compensating comparison was performed for D{sub 90}. Stranded seeds were linked between TRUS and CBCT using an automatic and fast linking procedure. Displacement patterns were analyzed for each seed implantation location. Results: On average, an intraoperative (TRUS to CBCT) D{sub 90} decline of 10.6% ± 7.4% was observed. Intraoperative CBCT D{sub 90} showed a greater correlation (R{sup 2} = 0.33) with respect to Day 30 than did TRUS (R{sup 2} = 0.17). Compensating for edema, the correlation increased to 0.41 for CBCT and 0.38 for TRUS. The mean absolute intraoperative seed displacement was 3.9 ± 2.0 mm. The largest seed displacements were observed near the rectal wall. The central and posterior seeds showed less caudal displacement than lateral and anterior seeds. Seeds that were implanted closer to the base showed more divergence than seeds close to the apex. Conclusions: Intraoperative CBCT D{sub 90} showed a greater correlation with the day 30 dosimetry than intraoperative TRUS. Edema seemed to cause most of the systematic difference between the intraoperative and day 30 dosimetry. Seeds near the rectal wall showed the most displacement, comparing TRUS and CBCT, probably because of TRUS probe–induced prostate deformation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and testing of ultrasound probe adapters for a robotic imaging platform

Medical imaging-based triage is a critical tool for emergency medicine in both civilian and military settings. Ultrasound imaging can be used to rapidly identify free fluid in abdominal and thoracic cavities which could necessitate immediate surgical intervention. However, proper ultrasound image capture requires a skilled ultrasonography technician who is likely unavailable at the point of injury where resources are limited. Instead, robotics and computer vision technology can simplify image acquisition. As a first step towards this larger goal, here, we focus on the development of prototypes for ultrasound probe securement using a robotics platform. The ability of four probe adapter technologies to precisely capture images at anatomical locations, repeatedly, and with different ultrasound transducer types were evaluated across more than five scoring criteria. Testing demonstrated two of the adapters outperformed the traditional robot gripper and manual image capture, with a compact, rotating design compatible with wireless imaging technology being most suitable for use at the point of injury. Next steps will integrate the robotic platform with computer vision and deep learning image interpretation models to automate image capture and diagnosis. This will lower the skill threshold needed for medical imaging-based triage, enabling this procedure to be available at or near the point of injury.

47 OTHER INSTRUMENTATION↗

Cardiovascular Imaging and Image Processing: Theory and Practice - 1975

Ultrasonography was examined in regard to the developmental highlights and present applicatons of cardiac ultrasound. Doppler ultrasonic techniques and the technology of miniature acoustic element arrays were reported. X-ray angiography was discussed with special considerations on quantitative three dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body. Nuclear cardiography and scintigraphy, three--dimensional imaging of the myocardium with isotopes, and the commercialization of the echocardioscope were studied.

Harrison, Donald C.↗

Cardiovascular imaging and image processing: Theory and practice - 1975; Proceedings of the Conference, Stanford University, Stanford, Calif., July 10-12, 1975

The present collection of papers outlines advances in ultrasonography, scintigraphy, and commercialization of medical technology as applied to cardiovascular diagnosis in research and clinical practice. Particular attention is given to instrumentation, image processing and display. As necessary concomitants to mathematical analysis, recently improved magnetic recording methods using tape or disks and high-speed computers of large capacity are coming into use. Major topics include Doppler ultrasonic techniques, high-speed cineradiography, three-dimensional imaging of the myocardium with isotopes, sector-scanning echocardiography, and commercialization of the echocardioscope. Individual items are announced in this issue.

Harrison, D. C.↗

Leg muscle volume during 30-day 6-degree head-down bed rest with isotonic and isokinetic exercise training

Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.

Greenleaf, J. E.↗

Lower Extremity Muscle Thickness During 30-Day 6 degrees Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

Muscle thickness was measured in 19 Bed-Rested (BR) men (32-42 year) subjected to IsoTonic (ITE, cycle orgometer) and IsoKi- netic (IKE, torque orgometer) lower extremity exercise training, and NO Exercise (NOE) training. Thickness was measured with ultrasonography in anterior thigh-Rectus Femoris (RF) and Vastus Intermadius (VI), and combined posterior log-soleus, flexor ballucis longus, and tibialis posterior (S + FHL +TP) - muscles. Compared with ambulatory control values, thickness of the (S + FHL + TP) decreased by 90%-12% (p less than 0.05) In all three test groups. The (RF) thickness was unchanged in the two exercise groups, but decreased by 10% (p less than 0.05) in the NOE. The (VI) thickness was unchanged In the ITE group, but decreased by 12%-l6% (p less than 0.05) in the IKE and NOE groups. Thus, intensive, alternating, isotonic cycle ergometer exercise training is as effective as intensive, intermittent, isokinetic exercise training for maintaining thicknesses of rectus femoris and vastus lntermedius anterior thigh muscles, but not posterior log muscles, during prolonged BR deconditioning.

Ellis, S.↗

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗

Effect of perturbations and a meal on superior mesenteric artery flow in patients with orthostatic hypotension

Our aims were to evaluate to role of superior mesenteric blood flow in the pathophysiology of orthostatic hypotension in patients with generalized autonomic failure. METHODS: Twelve patients with symptomatic neurogenic orthostatic hypotension and 12 healthy controls underwent superior mesenteric artery flow measurements using Doppler ultrasonography during head-up tilt and tilt plus meal ingestion. Autonomic failure was assessed using standard tests of the function of the sympathetic adrenergic, cardiovagal and postganglionic sympathetic sudomotor function. RESULTS: Superior mesenteric flow volume and time-averaged velocity were similar in patients and controls at supine rest; however, responses to cold pressor test and upright tilt were attenuated (p < 0.05) in patients compared to controls. Head-up tilt after the meal evoked a profound fall of blood pressure and mesenteric blood flow in the patients; the reduction of mesenteric blood flow correlated (r = 0.89) with the fall of blood pressure in these patients, providing another manifestation of failed baroreflexes. We make the novel finding that the severity of postprandial orthostatic hypotension regressed negatively with the postprandial increase in mesenteric flow in patients with orthostatic hypotension. CONCLUSION: Mesenteric flow is under baroreflex control, which when defective, results in, or worsens orthostatic hypotension. Its large size and baroreflexivity renders it quantitatively important in the maintenance of postural normotension. The effects of orthostatic stress can be significantly attenuated by reducing the splanchnic-mesenteric volume increase in response to food. Evaluation of mesenteric flow in response to eating and head-up tilt provide important information on intra-abdominal sympathetic adrenergic function, and the ability of the patient to cope with orthostatic stress.

Non-NASA Center↗

Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

NASA Discipline Number 26-10↗

Ocular examination for trauma; clinical ultrasound aboard the International Space Station

BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

Clinical Trial↗

Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

Hurst, Victor↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique Into a Clinical Monitoring Tool for Space Flight

Emergency medicine physicians recently adopted the use of ultrasonography to quickly measure optic nerve sheath diameter (ONSD) as concomitant with increased intracranial pressure. NASA Space and Clinical Operations Division has been using ground and on-orbit ultrasound capabilities since 2009 to consider this anatomical measure as a proxy for intracranial pressure in the microgravity environment. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut-off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before missions. Crew Surgeon clinical decision-making is complicated by the fact that many astronauts have history of previous spaceflights. Data will be presented characterizing the distribution of baseline ONSD in the astronaut corps, longitudinal trends in-flight, and the predictive power of this measure related to increased intracranial pressure outcomes.

Mason, Sara S.↗

Evidence Based Medicine in Space Flight: Evaluation of Inflight Vision Data for Operational Decision-Making

Due to recently identified vision changes associated with space flight, JSC Space and Clinical Operations (SCO) implemented broad mission‐related vision testing starting in 2009. Optical Coherence Tomography (OCT), 3 Tesla Brain and Orbit MRIs, Optical Biometry were implemented terrestrially for clinical monitoring. While no inflight vision testing was in place, already available onorbit technology was leveraged to facilitate in‐flight clinical monitoring, including visual acuity, Amsler grid, tonometry, and ultrasonography. In 2013, on‐orbit testing capabilities were expanded to include contrast sensitivity testing and OCT. As these additional testing capabilities have been added, resource prioritization, particularly crew time, is under evaluation.

Van Baalen, Mary↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique into a Clinical Monitoring Tool for Spaceflight

Ultrasonography is increasingly used to quickly measure optic nerve sheath diameter (ONSD) when increased intracranial pressure (ICP) is suspected. NASA Space and Clinical Operations Division has been using ground and on‐orbit ultrasound since 2009 as a proxy for ICP in non‐acute monitoring for space medicine purposes. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut‐off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before launch. Crew Surgeon clinical decision‐making is complicated by the fact that many astronauts have history of previous spaceflights. Our data characterize the distribution of baseline ONSD in the astronaut corps, its longitudinal trends in long‐duration spaceflight, and the predictive power of this measure related to increased ICP outcomes.

Mason, Sara↗

Expanding Biological Repository Data Available for Sharing and Knowledge Discovery

Biology has developed next-generation data science and alternative analytical approaches with methodologies which require principal investigator (PI) experimental assay data be re-used. This new approach involves mining multiple datasets at once from various hierarchical organizations of biological complexity, while concurrently evaluating how experimental factors affect endpoints of standard assays. The purpose of the NASA Ames Life Sciences Data Archive (ALSDA) is to collect, curate, and make findable, accessible, interoperable, and reusable (FAIR) all non-human space-relevant biological data. These data include mission metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery, and subject-experienced telemetry (radiation, temperature, humidity, acoustics, vibrations). ALSDA has transformed to bring current biological repository data and all future collected data into this new scientific data mining reality. It has integrated into the ‘NASA Open Science’ group of projects to facilitate a suite of new tools and workflows to improve data accessibility and reusability by implementing data management plans, automating data submission agreements, and adopting the single-point-of-entry data submission portal, originally developed by NASA GeneLab. These systems required ALSDA to develop science assay configurations for the submission portal, capturing essential assay parameters according to established norms in each sub-field within biology. The submission portal expedites data collection by enhancing ease of PI data submission, providing a user interface and specificity for which data is to be submitted. ALSDA datasets are curated to maintain rich metadata, accuracy of datasets, data transparency, provenance, and additionally ensure data are machine-readable (e.g., R and Python languages). ALSDA integration with GeneLab and its analysis portals enable higher-order physiological-level datasets be mined in conjunction with -omics datasets. As ALSDA physiological-level datasets are published (micro-computed tomography, histology, intraocular pressure, hormonal assays, immunostaining, ultrasonography), the merging of hierarchical organizations of biological complexity from spaceflight will enable new knowledge discovery approaches.

Ryan T Scott↗

Results of a 3-day Pilot Study to Validate Planetary Prebreathe Protocols Using a 56.5 kPa 34% O2, 66% N2 Saturation Cabin Atmosphere

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies was initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 3-day human-in-the-loop system checkout. METHODS: Six volunteers acclimated to the 56.6kPa/34% O2 66% N2 environment for 48hrs prior to conducting a 20-minute prebreathe and a 6-hour simulated EVA at 34kPa/85% O2 / 15% N2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs. Decompression stress was evaluated by serial doppler and echocardiographs, as well as by clinical features of DCS signs/symptoms. RESULTS AND DISCUSSION: Preliminary data analysis noted venous gas emboli (VGE) in 3 of 6 subjects, with peak Grade II VGE by Doppler and peak E-B score of 5 by cardiac ultrasonography. No volunteers were diagnosed with DCS during this initial test. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Validation of exploration prebreathe protocols has since been initiated with an 11-day saturation test using the same facility and protocol.

Alejandro Garbino↗

Biological Data for Deep Space Mission Support

Increased biomedical risks and challenges associated with deep space missions (cis-Lunar, Mars transit, Mars surface) require new knowledge discovery and development of novel ecosystem and biomedical support capabilities. This paradigm shift supporting distant and long-duration missions requires biological data to be findable, accessible, interoperable, reusable (FAIR), and maximally open-access (i.e., there is a data governance continuum from closed to mediated to embargoed to open). The NASA “Open Science Data Repositories” (OSDR) aims to meet scientific, technical, and operational spaceflight needs, and offers the ability to upload, download, search, share, analyze, and visualize data across physiological, behavioral, ‘omics, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive (ALSDA), and NASA Biological Institutional Scientific Collection (NBISC). In the past year, ALSDA has undergone a transformation in its data collection, curation, and architecture methods. Standardizing non-genomic (phenotypic) datasets was, and will continue to be, a challenge because of their diverse nature (e.g., molecular, cellular, tissue, whole organism behavior; micro-computed tomography, intraocular pressure, fluorescence microscopy, western blot, ultrasonography; tabular, images, video). This year ALSDA, alongside GeneLab, introduced the Biological Data Management Environment (BDME) with the purpose to accept submission of data from space relevant experiments including spaceflight, radiation, simulated gravity, gravitropism, isolation and confinement, hostile closed environments and/or distance from Earth. In addition to bringing together omics, phenotypic, physiological, bioimaging, and behavioral data into one repository. By integrating with GeneLab a multi-project submission portal aims to reduce the burden on PIs submitting data and enabling the discovery of both omics and phenotypic data. The purpose of ALSDA is to collect, curate, and make all non-human space-relevant biological data maximally findable, accessible, interoperable, and reusable (FAIR). These scope of ALSDA data collected and submitted by PIs include study design metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). In 2021, a community of researchers rallied to form the ALSDA Analysis Working Group (AWG) and provided scientific consensus on dataset sample and assay metadata. The community and excitement around the ALSDA/OSDR system has already led to several data reuse studies, demonstrating value using machine learning (ML), knowledge graphs, and meta-analysis approaches.

space biology↗