Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Two-Phase Heat Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hydrodynamic models of the cometary atmosphere

Self-consistent transonic multifluid solutions for the dynamical and thermal structure of the two-phase dusty gas atmosphere of a comet containing a dirty H2O-clathrate ice nucleus have been obtained. This was done by solving a simultaneous set of differential equations representing conservation of number density, momentum, and energy, as well as the transfer of solar radiation responsible for the major photolytic processes and nuclear heating. The results presented include velocity and Mach number profiles of heavy species and the velocity of dust within the subsonic and supersonic regions, temperature profiles of the dust and gas in the supersonic region, and radial profiles of electron and ion densities in the collision-dominated region.

Mendis, D. A.

Review of Orbital Propellant Transfer Techniques and the Feasibility of a Thermal Bootstrap Propellant Transfer Concepts

This study was performed in support of the NASA Task B-2 Study Plan for Space Basing. The nature of space-based operations implies that orbital transfer of propellant is a prime consideration. The intent of this report is (1) to report on the findings and recommendations of existing literature on space-based propellant transfer techniques, and (2) to determine possible alternatives to the recommended methods. The reviewed literature recommends, in general, the use of conventional liquid transfer techniques (i.e., pumping) in conjunction with an artificially induced gravitational field. An alternate concept that was studied, the Thermal Bootstrap Transfer Process, is based on the compression of a two-phase fluid with subsequent condensation to a liquid (vapor compression/condensation). This concept utilizes the intrinsic energy capacities of the tanks and propellant by exploiting temperature differentials and available energy differences. The results indicate the thermodynamic feasibility of the Thermal Bootstrap Transfer Process for a specific range of tank sizes, temperatures, fill-factors and receiver tank heat transfer coefficients.

Yoshikawa, H. H.

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Design and test of a pumped two-phase mounting plate

The design, fabrication, and testing of the full-scale development unit of a pumped two-phase mounting plate (TPMP) used in advanced two-phase spacecraft thermal control systems are described. The mounting plate is tested with R-11 in the evaporator mode for total heat loads of over 3000 watts and local heat fluxes over 4 W/sq cm, and in the condenser mode with condenser loads from 60 to 400 watts and inlet qualities from 8 to 94 percent. The calculated heat-transfer coefficients are between 0.66 and 1.0 W/sq cm/C and are nearly independent of the flow rate and heat load except at very low heat loads. It is shown that the TPMP can be run with inlet conditions down to 22 C subcooling without any significant gradients in the plate and that it performs well with nonuniform heat fluxes.

Grote, M. G.

ASRDI oxygen technology survey. Volume 3: Heat transfer and fluid dynamics. Abstracts of selected technical reports and publications

Selected information is presented from an assemblage of reports and publications on heat transfer and fluid dynamics with direct applicability to oxygen systems. For each document cited, an abstract has been prepared together with key words and a listing of most important references found in the document. Additionally, an author index, a subject index, and a key word index have been provided to simplify the retrieval of specific information from this work. In each subject area - e.g., boiling heat transfer - the individual citations are listed alphabetically by first author, with review papers dually noted under the appropriate subject category and under review papers. Of the documents reviewed and evaluated for inclusion in this publication, coverage of existing information directly concerned with oxygen was given primary emphasis. However, work not specifically oxygen-designated but considered applicable to oxygen by the reviewer e.g., a two-phase friction factor correlation derived from nitrogen experiments is occasionally given where no actual oxygen data exist, as an aid to the reader. Approximately 130 abstracts are listed.

Schmidt, A. F.

MOSCATO Development and Integration in Fiscal Year 2025: Implementation of Multiphase, Multiphysics Modeling Capabilities for Molten Salt Systems

MOSCATO (Molten Salt Chemistry and Transport) is a multiphysics code that provides high-fidelity, coupled simulations of fluid flow, heat transfer, mass transfer, chemistry, electrochemical phenomena, and alloy corrosion for molten salt systems. In FY25, significant developments were made to the code package, enhancing its capabilities for modeling all relevant phenomena within operating moltens salt reactors (MSRs). The developments and activities in FY25 included: 1. Implementation of Level-Set methods to enable modeling of single-bubble behavior in molten salts. In FY25, the Level-Set two-phase flow modeling implementation was improved to simulate single bubble behavior with molten salt media. The large density and viscosity ratios between typical gases and molten salt liquids present challenges for these types of numerical solvers. With enhancements to the pressure projection method, MOSCATO’s Level-Set solver was able to be successfully validated to experiments related to helium bubble rise in stagnant molten salt. The simulated bubble rising velocity showed reasonable good agreement with experimental measurements. The bubble shape and dynamics were also visually compared with experimental snapshots, demonstrating a good qualitative match. 2. Generation of mass transfer correlations for multiphase flow systems. To enable calculations of the tritium transport across the interface between gas bubbles and salt, we modeled high- Schmidt-number mass transfer around a sphere across a broad range of Reynolds numbers. The mesh near the sphere surface was highly refined to resolve steep concentration gradients caused by the low diffusion coefficient. Literature-based mass transfer correlations were compared with the numerical results, and modifications were proposed to improve agreement, particularly at higher Schmidt numbers. These mass transfer correlations were subsequently provided to other national laboratories to help enable high quality mass transfer simulations using lower-order solvers under development within the NEAMS program. 3. Preliminary implementation of a bubbly flow solver. To model bubbly flow in molten salt, we implemented a bubbly flow solver for void fractions less than 5%. To do so, an algebraic relative velocity model that assumes small bubbles with rapid momentum equilibration was added to MOSCATO to compute bubble velocities. Preliminary comparisons with experimental data showed reasonable agreement, and further improvements are underway. 4. Generation of mass transfer correlations for MSRE subchannel The Molten-Salt Reactor Experiment (MSRE) was a landmark historical project that demonstrated the feasibility of molten-salt reactor technology. The MSRE campaign also generated a significant body of experimental data and reports that continue to support molten-salt–related research. In this report, the MSRE core subchannel was used as the reference geometry for a mass transfer study performed with MOSCATO. The geometry and computational mesh were adapted from a previous study, providing adequate resolution for the relatively low Reynolds number in this case. Additional mesh refinement was applied to reach higher Schmidt numbers, enabling the derivation of a reliable mass-transfer correlation for the present scenario. 5. Simulations of oxygen ingressions into molten salt. In the previous fiscal year, we initiated a study to simulate oxygen ingression in stagnant salt. As oxygen enters the salt through its surface, it reacts with Ce 3+ to form solid CeO 2 and other reaction products. To more fully capture the complex diffusion-convection-reaction mechanisms, capabilities for modeling natural convection in the salt vessel were added. These were needed as the flow of the ingressed gas induced flow in the salt caused by surface shear and non-isothermal effects. With these updated physics in place, we were able to successfully reproduce the experimental results for the rate of change of CeCl 3 concentrations versus time. 6. Flow corrosion model validation. In FY24, MOSCATO’s corrosion model was validated against static corrosion experiments. In FY25, this work was extended to a flow corrosion experiment, where FLiNaK salt was driven by natural convection, with initial salt impurities to initiate corrosion. Despite uncertainties in parameters such as elemental diffusion coefficients in the alloy and unknown H + concentrations, the simulations achieved good agreement with experimental results, especially in predicting sample mass losses.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Heat Transfer and Fluid Mechanics Institute, Meeting, 26th, Washington State University, Pullman, Wash., June 26-28, 1978, Proceedings

Papers are presented on the heat transfer and fluid mechanics in energy systems including diesel combustion analysis using rapid sampling and the numerical simulation of thermal response of architectural structures. Experiments associated with hypersonic boundary layers, the prediction of nozzle-wall pressure distribution, and the effects of nozzle geometry on an axisymmetric thrust augmentor are outlined. Predictions are made of film thickness on a roll-metering device and the thermal characteristics of multiple-surface submerged condenser modules are described. Numerical studies are made of the interaction between natural and forced convection in a complex geometry and of pressure drop and holdup in two-phase stratified flow. A numerical solution is given for viscous flows at high Reynolds numbers and for compressible boundary layer flows near separation or reattachment. The structure and transport properties in turbulent shear flows are reviewed along with the spectra of Reynolds stresses in a developing pipe flow.

Crowe, C. T.

A pumped, two-phase flow heat transport system for orbiting instrument payloads

A pumped two-phase (heat absorption/heat rejection) thermal transport system for orbiting instrument payloads is investigated. The thermofluid characteristics necessary for the system design are discussed. A preliminary design with a series arrangement of four instrument heat stations and six radiators in a single loop is described in detail, and the total mass is estimated to be 134 kg, with the radiators, instrument heat stations, and fluid reservoir accounting for approximately 86, 24, and 12 kg, respectively. The evaluation of preliminary test results shows that the system has potential advantages; however, further research is necessary in the areas of one-g and zero-g heat transfer coefficients/fluid regimes, fluid by-pass temperature control, and reliability of small pumps.

Fowle, A. A.

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE neams program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework. This report summarizes recent advances in developing an integrated system- and engineering-scale modeling capability for the msr concept, which has gained significant interest in recent years. A consistent framework was established by coupling Pronghorn and SAM through the Saline interface, with thermophysical properties provided by the Molten Salt Thermal Property Database (MSTDB-TP). Further improvements were made to the coupling schemes and domain-overlapping strategies, enhancing the stability and robustness of multi-code simulations. Verification and validation efforts demonstrate the accuracy of this integration across a range of benchmark problems, including one-dimensional heated pipe flows, three-dimensional natural convection loops with evolving isotopic compositions, and \gls{msre} demonstration cases. Within Pronghorn, new capabilities were introduced to model corrosion and noble-metal plating phenomena, supported by an extended thermal-hydraulics framework and refined turbulence treatments. To capture two-phase flow behavior, a multiphase Euler–Euler model was implemented in Pronghorn, including advanced closure relations, high-resolution advection techniques, and capillary force reconstruction. Preliminary verification cases confirm the fidelity of the approach, while planned validation efforts target canonical multiphase benchmarks and application to msr components such as the msre pump bowl. Finally, updates to SAM’s msr mass transfer modeling were extended to consider noble gas migration into porous structures like graphite. The point kinetics model was updated to include reactivity feedback contributions from any defined species, such as xenon. The gas transport model was expanded for applicability to gas mixtures, bubble efflux phenomena, and species transport between liquid and gas phases. A selection of multi-scale Sherwood number correlations from MOSCATO/NekRS and multi-phase correlations from literature have been added for improved accuracy in calculating mass transfer coefficients. A companion effort on developing system-level redox corrosion has also been incorporated into SAM. Collectively, these enhancements strengthen the predictive capability of SAM and Pronghorn for simulating MSR thermal-hydraulics, corrosion, multiphase behavior, and fission-product transport, providing a more complete toolset for design, safety analysis, and licensing support of next-generation \gls{msr}s.

42 - ENGINEERING

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Deflagration to Detonation Transition Update: XDDT Code Modularization

A legacy FORTRAN 77 implementation of the Baer–Nunziato two-phase mixture theory for deflagration-to-detonation transition (DDT) in reactive granular materials—hereafter the XDDT (eXplosive DDT) code—has been modularized to Fortran 90 with modular structure, external input files, and adaptive mesh capability. During validation, two code defects were identified and corrected: an inconsistency in the nodal solid pressure evaluation and a nonphysical burn-front tracking criterion. The ignition criterion was also corrected to use the granular surface temperature from the interface heat transfer model, matching the original Baer implementation. An initial attempt to validate against Figure 3 of the original Baer and Nunziato (1986) paper revealed that the code’s detonation velocity on a 201-node mesh (5.5 km/s) was approximately 21% below the expected Chapman–Jouguet value for 70% TMD HMX (∼7 km/s). Validation was redirected to the piston-driven DDT experiments of McAfee et al. (1989), Shot B-9036, for which well-characterized ionization-pin data are available. With the compaction-burn coefficient calibrated to 𝐶 𝛼 = 75, the XDDT code reproduces the DDT transition time to within 0.4% and produces a steady-state detonation velocity within 4% of the McAfee experimental value of 6.36 km/s. The burn model was generalized to support pressure-dependent exponents, enabling application to nitrocellulose-based ball propellants (TS3659) with a cube-root pressure dependence. Validation against the Sandusky/Baer PDC82 piston-impact experiment yielded a reactive wave velocity of 2.3–2.8 km/s, in good agreement with the experimental value of ∼2.2 km/s, and wave coalescence within 5% of the experimental timing. The mathematical model, input parameter requirements, and a roadmap for extending XDDT to PETN with an autocatalytic burn model are presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF

Assessment of analytical techniques for predicting solid propellant exhaust plumes

The calculation of solid propellant exhaust plume flow fields is addressed. Two major areas covered are: (1) the applicability of empirical data currently available to define particle drag coefficients, heat transfer coefficients, mean particle size and particle size distributions, and (2) thermochemical modeling of the gaseous phase of the flow field. Comparisons of experimentally measured and analytically predicted data are made. The experimental data were obtained for subscale solid propellant motors with aluminum loadings of 2, 10 and 15%. Analytical predictions were made using a fully coupled two-phase numerical solution. Data comparisons will be presented for radial distributions at plume axial stations of 5, 12, 16 and 20 diameters.

Tevepaugh, J. A.

Conceptual design for spacelab two-phase flow experiments

KC-135 aircraft tests confirmed the gravity sensitivity of two phase flow correlations. The prime component of the apparatus is a 1.5 cm dia by 90 cm fused quartz tube test section selected for visual observation. The water-cabin air system with water recycle was a clear choice for a flow regime-pressure drop test since it was used satisfactorily on KC-135 tests. Freon-11 with either overboard dump or with liquid-recycle will be used for the heat transfer test. The two experiments use common hardware. The experimental plan covers 120 data points in six hours with mass velocities from 10 to 640 kg/sec-sq m and qualities 0.01 to 0.64. The apparatus with pump, separator, storage tank and controls is mounted in a double spacelab rack. Supporting hardware, procedures, measured variables and program costs are defined.

Bradshaw, R. D.

Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

Saaski, E. W.

A swirl flow evaporative cold plate

A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

Niggemann, R. E.

Two-phase flows within systems with ambient pressure

In systems where the design inlet and outlet pressures are maintained above the thermodynamic critical pressure, it is often assumed that two phase flows within the system cannot occur. Designers rely on this simple rule of thumb to circumvent problems associated with a highly compressible two phase flow occurring within the supercritical pressure system along with the uncertainties in rotordynamics, load capacity, heat transfer, fluid mechanics, and thermophysical property variations. The simple rule of thumb is adequate in many low power designs but is inadequate for high performance turbomachines and linear systems, where two phase regions can exist even though outlet pressure is greater than critical pressure. Rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two phase zone can differ significantly from those for a single-phase zone. Using the Reynolds equation the angular velocity, eccentricity, geometry, and ambient conditions are varied to determine the point of two phase flow incipience.

Hendricks, R. C.