Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transition Edge Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme provides for the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of ~16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G’s measurements of sky power on large angular scales. Measurements further show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

47 OTHER INSTRUMENTATION↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The POLARBEAR-2 and Simons Array Focal Plane Fabrication Status

We present on the status of POLARBEAR-2 A (PB2-A) focal plane fabrication. The PB2-A is the first of three telescopes in the Simons Array, which is an array of three cosmic microwave background polarization-sensitive telescopes located at the POLARBEAR site in Northern Chile. As the successor to the PB experiment, each telescope and receiver combination is named as PB2-A, PB2-B, and PB2-C. PB2-A and -B will have nearly identical receivers operating at 90 and 150 GHz while PB2-C will house a receiver operating at 220 and 270 GHz. Each receiver contains a focal plane consisting of seven close-hex packed lenslet-coupled sinuous antenna transition edge sensor bolometer arrays. Each array contains 271 dichroic optical pixels, each of which has four TES bolometers for a total of 7588 detectors per receiver. We have produced a set of two types of candidate arrays for PB2-A. The first we call Version 11 (V11) uses a silicon oxide (SiOx) for the transmission lines and crossover process for orthogonal polarizations. The second we call Version 13 (V13) uses silicon nitride (SiNx) for the transmission lines and cross-under process for orthogonal polarizations. We have produced enough of each type of array to fully populate the focal plane of the PB2-A receiver. The average wirebond yield for V11 and V13 arrays is 93.2% and 95.6%, respectively. The V11 arrays had a superconducting transition temperature (T-c) of 452 +/- 15 mK, a normal resistance (R-n) of 1.25 +/- 0.20 Omega, and saturation powers of 5.2 +/- 1.0 pW and 13 +/- 1.2 pW for the 90 and 150 GHz bands, respectively. The V13 arrays had a superconducting transition temperature (T-c) of 456 +/- 6 mK, a normal resistance (R-n) of 1.1 +/- 0.2 Omega, and saturation powers of 10.8 +/- 1.8 pW and 22.9 +/- 2.6 pW for the 90 and 150 GHz bands, respectively. Production and characterization of arrays for PB2-B are ongoing and are expected to be completed by the summer of 2018. We have fabricated the first three candidate arrays for PB2-C but do not have any characterization results to present at this time.

CMB↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Tube Interference in Cryogenic Sensors - Oral Presentation [Slides]

Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

47 OTHER INSTRUMENTATION↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Controlling T c of Iridium films using interfacial proximity effects

High precision calorimetry using superconducting transition edge sensors requires the use of superconducting films with a suitable T c , depending on the application. To advance high-precision macrocalorimetry, we require low-T c films that are easy to fabricate. A simple and effective way to suppress T c of superconducting Iridium through the proximity effect is demonstrated by using Ir/Pt bilayers as well as Au/Ir/Au trilayers. While Ir/Au films fabricated by applying heat to the substrate during Ir deposition have been used in the past for superconducting sensors, we present results of T c suppression on Iridium by deposition at room temperature in Au/Ir/Au trilayers and Ir/Pt bilayers in the range of $\sim$20-100~mK. Measurements of the relative impedance between the Ir/Pt bilayers and Au/Ir/Au trilayers fabricated show factor of $\sim$10 higher values in the Ir/Pt case. These new films could play a key role in the development of scalable superconducting transition edge sensors that require low-T c films to minimize heat capacity and maximize energy resolution, while keeping high-yield fabrication methods.

Hennings-Yeomans, R↗

Error-Correcting Codes for Code-Division Multiplexed TES Detectors

Transition edge sensors (TESs) have proven to be highly sensitive and versatile X-ray spectrometers. Upcoming missions, including Athena X-IFU, will rely on highly multiplexed focal planes where more than 32 TES pixels are read out using a single SQUID amplifier channel. We have implemented an error correction algorithm for code-division multiplexed TES signals that can compensate for potential failures of individual SQUID readout channels and that is both scalable and easily implemented in hardware. We present this algorithm for error correction and show results of laboratory tests to assess algorithm performance at recovering TES channels after a SQUID failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spread-Spectrum SQUID Multiplexer

The transition-edge sensor (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz frequencies. However, the multiplexing factor achievable with microwave SQUIDs is limited by the high slew rate on the leading edge of x-ray pulses. In this paper, we propose a new multiplexing scheme for high-slew-rate TES x-ray calorimeters: the spread-spectrum SQUID multiplexer, which has the potential to enable higher multiplexing factors, especially in applications with lower photon-arrival rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ~2 m 2 of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

47 OTHER INSTRUMENTATION↗

Pulse Tube Interference in Cryogenic Sensor Resonant Circuits (Final Paper)

Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

42 ENGINEERING↗

Developing AlMn Films for Argonne TES Fabrication

The reference design for the next-generation cosmic microwave background (CMB) experiment, CMB-S4, relies on large arrays of transition-edge sensor (TES) bolometers coupled to Superconducting Quantum Interference Device (SQUID)-based readout systems. Mapping the CMB to near cosmic variance limits will enable the search for signatures of inflation and constrain dark energy and neutrino physics. AlMn TESes provide simple film manufacturing and highly uniform arrays over large areas to meet the requirements of the CMB-S 4 experiment. TES parameters such as critical temperature and normal resistance must be tuned to experiment specifications and can be varied based on geometry and steps in the fabrication process such as deposition layering, geometry, and baking time and temperature. Using four-terminal sensing, we measured T C and R N of AlMn 2000 ppm films and devices of varying thicknesses fabricated at Argonne National Laboratory to motivate device geometries and fabrication processes to tune T C to 150–200 mK and R N to ~10 mΩ. Furthermore, measurements of IV curves and time constants for the resulting devices of varying leg length were made using time-division SQUID multiplexing and determined TC, G, k, f 3db , and RN. We present the results of these tests along with the geometries and fabrication steps used to tune the device parameters to the desired limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗