Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Three-dimensional tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Understanding the Effect of Curvature on the Magnetization Reversal of Three-Dimensional Nanohelices

Comprehending the interaction between geometry and magnetism in three-dimensional (3D) nanostructures is important to understand the fundamental physics of domain wall (DW) formation and pinning. Here, we use focused-electron-beam-induced deposition to fabricate magnetic nanohelices with increasing helical curvature with height. Using electron tomography and Lorentz transmission electron microscopy, we reconstruct the 3D structure and magnetization of the nanohelices. The surface curvature, helical curvature, and torsion of the nanohelices are then quantified from the tomographic reconstructions. Furthermore, by using the experimental 3D reconstructions as inputs for micromagnetic simulations, we can reveal the influence of surface and helical curvature on the magnetic reversal mechanism. Hence, we can directly correlate the magnetic behavior of a 3D nanohelix to its experimental structure. In conclusion, these results demonstrate how the control of geometry in nanohelices can be utilized in the stabilization of DWs and control of the response of the nanostructure to applied magnetic fields.

36 MATERIALS SCIENCE↗

Non-averaged single-molecule tertiary structures reveal RNA self-folding through individual-particle cryo-electron tomography

Large-scale and continuous conformational changes in the RNA self-folding process present significant challenges for structural studies, often requiring trade-offs between resolution and observational scope. Here, we utilize individual-particle cryo-electron tomography (IPET) to examine the post-transcriptional self-folding process of designed RNA origami 6-helix bundle with a clasp helix (6HBC). By avoiding selection, classification, averaging, or chemical fixation and optimizing cryo-ET data acquisition parameters, we reconstruct 120 three-dimensional (3D) density maps from 120 individual particles at an electron dose of no more than 168 e - Å -2 , achieving averaged resolutions ranging from 23 to 35 Å, as estimated by Fourier shell correlation (FSC) at 0.5. Each map allows us to identify distinct RNA helices and determine a unique tertiary structure. Statistical analysis of these 120 structures confirms two reported conformations and reveals a range of kinetically trapped, intermediate, and highly compacted states, demonstrating a maturation folding landscape likely driven by helix-helix compaction interactions.

36 MATERIALS SCIENCE↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft X-Ray Tomography Has Evolved into a Powerful Tool for Revealing Cell Structures

Over the past three decades, soft X-ray tomography (SXT) has rapidly evolved from a proof-of-concept microscopy method into a high-throughput quantitative imaging modality. This advancement enables researchers to address central questions in cell biology. Despite its relatively short developmental period compared to light and electron microscopy, SXT has emerged as a powerful imaging technology. It enables measuring chemical changes in cellular organelles, analyzing three-dimensional structures of whole cells and creating digital cellular models to study cell motility. We discuss the unique nature of SXT to visualize cells without fixation or labeling, enabling quantitative analyses of organelle chemical composition. We explore SXT microscopes available worldwide, SXT segmentation software, and the diverse cell types studied using this technique. We conclude with emerging directions in SXT imaging, including a brief discussion of recent discoveries that are highly influential and likely to become integral to cell biology textbooks.

Weinhardt, Venera↗

A microCT-based platform to quantify drug targeting

Abstract Background Heterotopic ossification (HO) is a frequent and debilitating complication of traumatic musculoskeletal injuries and orthopedic procedures. Prophylactic dosing of botulinum toxin type A (BTxA) holds potential as a novel treatment option if accurately distributed throughout soft-tissue volumes where protection is clinically desired. We developed a high-resolution, microcomputed tomography (microCT)-based imaging strategy to assess drug distribution and validated this platform by quantifying distribution achieved via a prototype delivery system versus a single-bolus injection. Methods We injected an iodine-containing contrast agent (iodixanol 320 mg I/mL) into dissected rabbit musculature followed by microCT imaging and analysis. To contrast the performance of distributed versus bolus injections, a three-dimensional (3D) 64-cm 3 -printed soft-tissue holder was developed. A centered 2-cm 3 volume of interest (VOI) was targeted with a single-bolus injection or an equal volume distributed injection delivered via a 3D-printed prototype. VOI drug coverage was quantified as a percentage of the VOI volume that was < 1.0 mm from the injected fluid. Results The microCT-based approach enabled high-resolution quantification of injection distribution within soft tissue. The distributed dosing prototype provided significantly greater tissue coverage of the targeted VOI (72 ± 3%, mean ± standard deviation) when compared to an equal volume bolus dose (43 ± 5%, p = 0.031) while also enhancing the precision of injection targeting. Conclusions A microCT-based imaging technique precisely quantifies drug distribution within a soft-tissue VOI, providing a path to overcome a barrier for clinical translation of prophylactic inhibition of HO by BTxA. Relevance statement This platform will facilitate rapid optimization of injection parameters for clinical devices used to effectively and safely inhibit the formation of heterotopic ossification. Key points • MicroCT provides high-resolution quantification of soft-tissue drug distribution. • Distributed dosing is required to maximize soft-tissue drug coverage. • Imaging platform will enable rapid screening of 3D-printed drug distribution prototypes. Graphical Abstract

Ausk, Brandon J. (ORCID:0000000335338303)↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

Three-dimensional atomic structure and local chemical order of medium- and high-entropy nanoalloys

Medium- and high-entropy alloys (M/HEAs) mix several principal elements with near-equiatomic composition and represent a model-shift strategy for designing previously unknown materials in metallurgy, catalysis and other fields. One of the core hypotheses of M/HEAs is lattice distortion, which has been investigated by different numerical and experimental techniques. However, determining the three-dimensional (3D) lattice distortion in M/HEAs remains a challenge. Moreover, the presumed random elemental mixing in M/HEAs has been questioned by X-ray and neutron studies, atomistic simulations, energy dispersive spectroscopy and electron diffraction, which suggest the existence of local chemical order in M/HEAs. However, direct experimental observation of the 3D local chemical order has been difficult because energy dispersive spectroscopy integrates the composition of atomic columns along the zone axes and diffuse electron reflections may originate from planar defects instead of local chemical order. Here, in this work, we determine the 3D atomic positions of M/HEA nanoparticles using atomic electron tomography and quantitatively characterize the local lattice distortion, strain tensor, twin boundaries, dislocation cores and chemical short-range order (CSRO). We find that the high-entropy alloys have larger local lattice distortion and more heterogeneous strain than the medium-entropy alloys and that strain is correlated to CSRO. We also observe CSRO-mediated twinning in the medium-entropy alloys, that is, twinning occurs in energetically unfavoured CSRO regions but not in energetically favoured CSRO ones, which represents, to our knowledge, the first experimental observation of correlating local chemical order with structural defects in any material. We expect that this work will not only expand our fundamental understanding of this important class of materials but also provide the foundation for tailoring M/HEA properties through engineering lattice distortion and local chemical order.

36 MATERIALS SCIENCE↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards a quantitative understanding of bonding in supersonic single particle impacts: A three-dimensional FIB-SEM exploration

Particle bonding is crucial to coating quality in cold spray, but it has been a challenge to accurately quantify bonding even in single particle impacts. This paper uses FIB-SEM to explicitly map the particle-substrate interface for Cu-on-Cu single microparticle impacts in a full 3D rendering that spans a wide range of impact velocities. This approach permits a detailed quantification of the total bonding area and all of its associated components. In addition to revealing why prior 2D characterization efforts have missed important details about impact bonding, these data quantitatively reveal the evolution of bonding from its onset at the “critical velocity” V cr (where bonding is generally poor, ∼6 %) to its peak at around 1.3‧V cr (where almost 90 % of the particle bonds). Further increase in the velocity to 1.5‧V cr and beyond finds the onset of hydrodynamic penetration and a decrease in bonding. These data then support the development of a simple analytical model based on oxide rarefication and extrusion of bare metal through gaps in the oxide layer as driving the development of bonding. As a result, the model reproduces the experiments and provides guidance on optimization of bonding as a function of material and process parameters.

Analytical methods↗

Three-dimensional structure of buried heterointerfaces revealed by multislice ptychography

Here, we report on the three-dimensional (3D) structure determination of a twisted hexagonal boron nitride (h-BN) heterointerface from a single-view dataset using multislice ptychography. We identify the buried heterointerface between two twisted h-BN flakes with a lateral resolution of 0.57 Å and a depth resolution of 2.5 nm. The latter represents a significant improvement (∼2.7 times) over the aperture-limited depth resolution of incoherent imaging modes, such as annular-dark-field scanning transmission electron microscopy. This improvement is attributed to the diffraction signal extending beyond the aperture edge, with the depth resolution set by the curvature of the Ewald sphere. Future advancements in this approach could enhance the depth resolution to the subnanometer level and enable the identification of individual dopants, defects, and color centers in twisted heterointerfaces and other materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving the stability and performance of MagLIF implosions by applying dielectric coatings and increasing applied B z , fuel preheat, and load current

We report two magnetized liner inertial fusion (MagLIF) experiments that produced record thermonuclear D–D neutron yields of 2.11×10 13 and 2.33×10 13 . These yields are about a factor of two higher than previous MagLIF results. The experiments achieved ion temperatures of 3.0 and 3.3 keV and stagnation pressures of 1.6 and 1.3 Gbar. The inferred Lawson parameters were χ=0.2 and 0.1, which are the largest reported for MagLIF. The performance increase used a high-aspect-ratio beryllium liner with a dielectric coating and modest increases in preheat energy (∼2.2 kJ), peak current (18.5 MA), and axial magnetic field (15 T). Three-dimensional HYDRA simulations are consistent with the measured liner dynamics and fusion outputs. These results indicate a pathway to higher-yield MagLIF designs using coated, high-aspect-ratio liners and improved input parameters. Simulations further suggest that adding an ice fuel layer could increase yield by up to a factor of 2.5 by reducing liner convergence, instability feedthrough, and mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unraveling Impurity-Dependent Morphological and Chemical Evolution of Ni–20Cr Alloy in Eutectic LiCl–KCl Molten Salt

Understanding the interfacial evolution of alloys in molten salt with different amounts of water (H 2 O) and oxygen (O 2 ) impurities is significant for applications in many fields, including concentrated solar power, molten salt reactors, and applications in pyrochemical reprocessing and electrorefining. Additionally, the impurity-driven corrosion mechanisms that lead to various morphological and chemical evolution characteristics at the interfaces of structural alloys and molten salts are not fully understood. In the present work, the three-dimensional (3D) morphological evolution of Ni-20Cr microwires in LiCl-KCl was studied at 500 °C under different moisture and oxygen conditions using in situ synchrotron transmission X-ray microscopy (TXM) and scanning transmission electron microscopy (STEM) techniques. No significant morphological changes were observed in Ni-20Cr microwires under vacuum conditions. However, the wires exhibited distinct morphological evolutions when exposed to molten salt containing H 2 O alone, as well as when both H 2 O and O 2 were present. Furthermore, Cr 2 O 3 precipitates were observed in the molten salt during corrosion with only H 2 O present, while Cr 6+ species were identified in the salt when O 2 was added. Further, these findings are crucial for understanding the corrosion mechanisms of molten salt with different amounts of H 2 O and O 2 contamination, providing insights for developing corrosion mitigation methods and improving the stability of containment alloys in molten salt applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗