Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Three-dimensional tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

76 records · Page 5

Multiscale Failure Analysis of a 3D Woven Unit Cell Containing Defects

Multiscale failure simulations have been performed for a Three-dimensional woven composite unit cell considering five, or more, length scales spanning the woven composite mesoscale to the sub-microscale voids. The multiscale recursive micromechanics approach, which enables recursive integration of general micromechanics theories over an arbitrary number of length scales, has been employed within the NASA Multiscale Analysis Tool. The multiscale model uses both the generalized method of cells and Mori-Tanaka micromechanics theories, and considers failure in the constituent materials using a simple damage model. Baseline results, containing distributed voids, are compared to uniaxial experimental data for an AS4 carbon fiber/ RTM6 epoxy matrix 3D orthogonal woven composite with good agreement in terms of global stiffness and global failure stress. The simulations demonstrate that the 3D woven composite exhibits damage tolerance through sustaining increasing axial load far beyond the first initiation of damage. The multiscale model is used to examine the nonlinear response of the material to other loading conditions. Case studies, motivated by X-ray computed tomography data, are presented on the effects of manufacturing induced voids and cracks.

3D woven↗

Uses of Computed Tomography in the NASA Materials Science Program

Computed Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used to characterize materials in preparation for flight, to determine thermal expansion values, and to examine long duration space grown materials, i.e. meteorites. The work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. This will include both the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along single crystals of germanium-silicon alloys. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication and installation of a single zone furnace incorporating a heat pipe to ensure of high temperature uniformity. At the time of writing the thermal expansion of lead has been measured from room temperature to 900 C. Three methods are available. Digital radiography enable length changes to be determined. Prior to melting the sample is small than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the lead alloyed with antimony is ready for scanning. This corresponds to the planned composition of Dr. Poirier's flight experiment. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the iron-nickel phase has coarsened during slow cooling over hundreds of millions of years.

Engel, H. Peter↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗

Three-Dimensional Reconstruction of Defects and Structures in Additively Manufactured Parts with Automated Serial Sectioning

Metal additive manufacturing (AM) processes have been demonstrated to be effective at reducing costs and lead times associated with complex components for space flight applications. Laser powderbed fusion (L-PBF) is a commonly used AM technology due to the ability to produce complex parts with fine feature resolution in a wide variety of alloys and applications. L-PBF, like many other manufacturing processes, can produce minor flaws in parts when in nominal operation as well as process-escape defects when process abnormalities occur. The effects of the flaws and methods of detecting the flaws are a subject of interest to understand the difficulties in detecting these flaws with current technology and how much risk the flaws or defects pose to potential flight parts. Using a RoboMet.3D automated serial sectioning system, seeded defects as well as minor process flaws can be imaged and reconstructed in three dimensions to compare to non-destructive evaluation (NDE) techniques, such as x-ray computed tomography (CT), neutron CT, and in-situ monitoring. The RoboMet automates the metallography process by automatically grinding, polishing, and imaging samples in a single system and providing the control data for NDE comparisons to know the real size of defects built into coupons. These comparisons provide an understanding behind the technological limitations of the NDE techniques for different alloys. The same serial sectioning methods have also been utilized to characterize the surfaces of parts to reconstruct the surfaces and take measurements of internal features not easily examined with non-destructive methods. Using the RoboMet, fine lattice structures built with L-PBF have been characterized to determine the actual thicknesses of struts and density of the lattice structures. These structures have been used as finer build supports for the L-PBF process, designs for fine catalysts, and other design considerations for small components. The RoboMet data helps to inform the modeling and design efforts around these fine components.

additive manufacturing↗