Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thin Section”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fluid inclusions in stony meteorites - A cautionary note

Newly discovered fluid inclusions in thin sections of Bjurbole chondrules, shergottite EETA79001, lunar meteorite ALHA81005, and Apollo 16 glasses possess physical properties similar to those of fluid inclusions found in thin sections of five stony meteorites recently described by Warner et al. (1983). The distribution and physical properties of these new fluid inclusions indicate they may be artifacts of thin section preparation; it is suggested that saw coolant was sucked into vacuum vesicles in glasses and minerals through submicroscopic fractures produced during sawing. The similarities between these fluid inclusions and fluid inclusions previously described by Warner et al. (1983) indicate that many of the fluid inclusions reported earlier may be artifacts. Consequently, the origin of any fluid inclusions observed in thin sections of extraterrestrial materials must be interpreted with caution. The most probable true extraterrestrial fluid inclusions are those that have been observed in grains prepared without exposure to liquids of any kind.

Rudnick, R. L.↗

Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites was studied. Major organs (brain, lung, liver, kidney, muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. Furthermore, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Drug Distribution Images from Thin Tissue Sections Obtained Using Desorption Electrospray Ionization Tandem Mass Spectrometry and Whole-Body Autoradiography

Desorption electrospray ionization tandem mass spectrometry (DESI-MS/MS) and whole-body autoradiography (WBA) were used for chemical imaging of whole-body thin tissue sections of mice intravenously dosed with propranolol (7.5 mg/kg). DESI-MS/MS imaging utilized selected reaction monitoring detection performed on an AB/MDS SCIEX 4000 QTRAP mass spectrometer equipped with a prototype extended length particle discriminator interface. Propranolol images of the tissue sections using DESI-MS/MS were obtained at surface scan rates of 0.1, 0.5, 2 and 7 mm/s. Although signal decreased with increasing scan rate, useful whole-body images for propranolol were obtained from the tissues even at 7 mm/s, which required just 79 min of analysis time. Attempts to detect and image the distribution of the known propranolol metabolites were unsuccessful. Regions of the tissue sections showing the most radioactivity from WBA sections were excised and analyzed by HPLC with radiochemical detection to determine relative levels of propranolol and metabolites present. Comparison of the DESI-MS/MS signal for propranolol and the radioactivity attributed to propranolol from WBA sections indicated nominal agreement between the two techniques for the amount of propranolol in the brain, lung, and liver. Data from the kidney showed an unexplained disparity between the two techniques. The results of this study show the feasibility of using DESI-MS/MS to obtain useful chemical images of a drug in whole-body thin tissue sections following drug administration at a pharmacologically relevant level. Further optimization to improve sensitivity and enable detection of the drug metabolites will be among the requirements necessary to move DESI-MS/MS chemical imaging forward as a practical tool in drug discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Microstructural evaluation of thin-wall sections of 316L stainless steel produced by laser powder-bed fusion processing

The synthesis of thin wall sections that are only 0.4 mm thick is achieved with LPBF AM. Sample preparation is optimized using metallographic polishing to produce samples with only 0.3 um rms roughness for scanning electron microanalysis with EBSD and EDS. A fully austenitic 316L phase is found without evidence of secondary phases. Unlike some AM products that can readily evidence composition segregation due to solute rejection as attributable to temperature gradients within the solidification

Jankowski, Alan F. [Sandia National Laboratories (↗

Assessing pore network heterogeneity across multiple scales to inform CO2 injection models

Geologic heterogeneity is a key feature that must be considered when translations of scaled data are performed. This paper presents the assessment of geologic heterogeneity using a multiscale workflow that includes image analysis-based methods coupled with well log analysis to provide data in which fractals and machine learning methods estimate the carbon dioxide (CO 2 ) storage resource potential of a reservoir. The heterogeneity of rock properties of the complex Bell Creek reservoir in Montana, USA, was explored at the pore scale (~nm to mm), core scale (~mm to m), and well scale (~cm to m). The data used in this study included advanced image analysis of micro-CT (computed tomography) images (pore scale), thin sections (pore scale), plugs and core images (core scale) and well logs (well scale). The micro-CT images were segmented using a U-net segmentation approach into objects of pores and grains. Further, the segmented images were reconstructed into subvolumes of different sizes. Physical properties (porosity and permeability) and fractal dimensions were calculated for the various subvolumes, and Lorenz coefficient (Lc) values, a single parameter to describe the degree of heterogeneity within a pay zone section, were calculated from thin-section images and well logs. Porosity and fractal dimension values were used to estimate the 188-µm threshold of representative elementary volume (REV) in this study. Both the Lc and fractal dimension values were found to be negatively correlated. When these two parameters are combined, it is possible to discern differences in the complex porous networks of the samples analyzed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Petrographic and spectral study of hydrothermal mineralization in drill core from Hawaii: A potential analog to alteration in the martian subsurface

Abstract Continuous rock core was collected for 1764 m (5786’) on the Pohakuloa Army Training base near the center of the big island of Hawaii. The core traverses basaltic lava flows from the volcano's shield-building phase, and perched aquifers and higher temperature groundwaters were encountered. The collected samples record water-rock interactions of basaltic materials in a setting that may be a model for groundwater interactions on Mars. We collected visible and infrared point spectra of materials in the lowest portion of the core, where alteration was noted to become more prominent. We identified three types of phyllosilicate spectral signatures and three types of zeolites. The phyllosilicates show similarity to those identified on Mars using data from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM). Based on the field survey, 25 depths were selected for sampling and petrographic analysis of thin sections. The spectral data and thin section work have a strong agreement in the types of materials identified by the two different techniques. Both the spectral and petrographic data indicate low to moderate temperature geothermal alteration occurred in the lower half of the core. The field spectra are a useful reconnaissance tool for selecting mineralogic diversity for subsequent higher resolution and more time-consuming laboratory analysis.

Geochemistry & Geophysics↗

Drag measurements of two thin wing sections at different index values

It is stated that the index value 6000, as found in normal tests of wing sections with a 20 cm chord, falls in the same region where the transition of laminar to turbulent flow takes place on thin flat plates. It is to be expected that slightly cambered, thin wing sections will behave similarly. The following test of two such wing sections were made for the purpose of verifying this supposition.

AIRFOILS↗

Liquid Microjunction Surface Sampling Probe Electrospray Mass Spectrometry for Detection of Drugs and Metabolites in Thin Tissue Sections

A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse body tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method Evaluation And Field Sample Measurements For The Rate Of Movement Of The Oxidation Front In Saltstone

The objective of this work was to develop and evaluate a series of methods and validate their capability to measure differences in oxidized versus reduced saltstone. Validated methods were then applied to samples cured under field conditions to simulate Performance Assessment (PA) needs for the Saltstone Disposal Facility (SDF). Four analytical approaches were evaluated using laboratory-cured saltstone samples. These methods were X-ray absorption spectroscopy (XAS), diffuse reflectance spectroscopy (DRS), chemical redox indicators, and thin-section leaching methods. XAS and thin-section leaching methods were validated as viable methods for studying oxidation movement in saltstone. Each method used samples that were spiked with chromium (Cr) as a tracer for oxidation of the saltstone. The two methods were subsequently applied to field-cured samples containing chromium to characterize the oxidation state of chromium as a function of distance from the exposed air/cementitious material surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid microjunction surface sampling of acetaminophen, terfenadine and their metabolites in thin tissue sections

The aim of this paper was to evaluate the analytical performance of a fully automated droplet-based surface-sampling system for determining the distribution of the drugs acetaminophen and terfenadine, and their metabolites, in rat thin tissue sections. The following are the results: The rank order of acetaminophen concentration observed in tissues was stomach > small intestine > liver, while the concentrations of its glucuronide and sulfate metabolites were greatest in the liver and small intestine. Terfenadine was most concentrated in the liver and kidney, while its major metabolite, fexofenadine, was found in the liver and small intestine. In conclusion, the spatial distributions of both drugs and their respective metabolites observed in this work were consistent with previous studies using radiolabeled drugs.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial profiling of stapled α–helical peptide ATSP-7041 in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC-ESI–MS/MS

Here, the application of a fully automated autosampler/HPLC-ESI–MS/MS system for spatially resolved quantitative droplet-based liquid extraction surface sampling/profiling of stapled α–helical peptide ATSP-7041 in mouse whole-body thin tissue sections is reported. 20-μm-thick serial tissue sections of an ATSP-7041 dosed mouse were prepared and the absolute concentration of the targeted peptide was first determined in different organs using 2.3-mm diameter tissue punches, standard bulk tissue extraction protocols, and subsequent HPLC separation and tandem mass spectrometric analysis. The same organs/locations were then analyzed in neighboring tissue sections using the droplet-based surface sampling approach. The observed ATSP-7041 concentration using this method was always significantly lower than that measured by the tissue punch workflow at the same tissue location of a serial section. Calculated extraction efficiencies were 10.7 ± 0.5% (brain), 11.0 ± 3.2% (liver spot 1), 10.7 ± 2.6% (liver spot 2), 15.0 ± 0.6% (lung) and 12.9 ± 0.7% (blood). While these extraction efficiency values were low, they were reproducible within a given organ. This suggests that once the extraction efficiency is established for a given tissue type and drug, the reproducibility of the droplet-based approach could provide a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

60 APPLIED LIFE SCIENCES↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

The oxidation state of sulfur in lunar apatites in meteorites versus Apollo rocks

Sulfur can be present in apatite mineral grains as S6+ [1], S2- [2], or a mixture of the two [3, 4]. The proportion of S6+ to S2- present in the apatite is thought to be predominantly controlled by the prevailing oxygen fugacity (fO2) conditions during crystallization (along with temperature, pressure, and major element composition; [2-4]). Measurements of apatites and proximal residual glass in the lunar basalts 12039 and 10044 by X-ray absorption near-edge structure (XANES) spectroscopy show that sulfur occurs as S2- in both the mesostasis glass and apatite when measurements are performed far from cracks or pits in the thin section [2], consistent with other mineralogical indications of low fO2 (∆IW-1) during petrogenesis. However, analyses of apatite grains in both samples that were acquired near cracks or pits in the thin section sometimes revealed minor but nonnegligible spectral evidence for the presence of S6+ (e.g., S6+/ΣS > 0.03; [2]). This evidence was interpreted as either primary S2- altered to S6+ in the thin section, or S6+ of secondary origin, deposited in the fractures of the samples [2, 5]. It is unknown whether this alteration is lunar or terrestrial in origin, with implications for lunar petrogenesis if lunar [e.g., 5], or sample handling and curation if terrestrial [e.g., 6]. Note: Extended abstract on document.

M. Brounce↗

Carbon analyses of IDP's sectioned in sulfur and supported on beryllium films

Carbon is the only major element in interplanetary dust whose abundance, distribution and chemical state are not well understood. Information about carbon could clarify the relationship between the various classes of IDP's, conventional meteorites, and sources (e.g., comets vs. asteroids). To date, the most reliable estimates of C abundance in Interplanetary Dust Particles (IDP's) have been obtained by analyzing particles on thick-flat Be substrates using thin-window energy-dispersive spectroscopy in the SEM. These estimates of C abundance are valid only if C is homogeneously distributed, because detected C x-rays originate from the outer 0.1 micrometers of the particle. An alternative and potentially more accurate method of measuring C abundances is to analyze multiple thin sections (each less than 0.1 less than 0.1 micrometers thick) of IDP's. These efforts however, have been stymied because of a lack of a suitable non-carbonaceous embedding medium and the availability of C-free conductive substrates. We have embedded and thin-sectioned IDP's in glassy sulfur, and transferred the thin sections to Be support films approximately 25 nm thick. The sections were then analyzed in a 200 KeV analytical TEM. S sublimes rapidly under vacuum in the TEM, leaving non-embedded sections supported on Be. Apart from quantitative C (and O) analyses, S sectioning dramatically expands the range of analytical measurements that can be performed on a single IDP.

Bradley, J. P.↗

Liquid Microjunction Surface Sampling Coupled with High-Pressure Liquid Chromatography-Electrospray Ionization-Mass Spectrometry for Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, two isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmaps of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.

drug metabolism↗

Serial Section Registration of Axonal Confocal Microscopy Datasets for Long-Range Neural Circuit Reconstruction

In the context of long-range digital neural circuit reconstruction, this paper investigates an approach for registering axons across histological serial sections. Tracing distinctly labeled axons over large distances allows neuroscientists to study very explicit relationships between the brain's complex interconnects and, for example, diseases or aberrant development. Large scale histological analysis requires, however, that the tissue be cut into sections. In immunohistochemical studies thin sections are easily distorted due to the cutting, preparation, and slide mounting processes. In this work we target the registration of thin serial sections containing axons. Sections are first traced to extract axon centerlines, and these traces are used to define registration landmarks where they intersect section boundaries. The trace data also provides distinguishing information regarding an axon's size and orientation within a section. We propose the use of these features when pairing axons across sections in addition to utilizing the spatial relationships amongst the landmarks. The global rotation and translation of an unregistered section are accounted for using a random sample consensus (RANSAC) based technique. An iterative nonrigid refinement process using B-spline warping is then used to reconnect axons and produce the sought after connectivity information.

59 BASIC BIOLOGICAL SCIENCES↗