Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “The Pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Metrology of Time-Domain Soft X-Ray Attosecond Pulses and Reevaluation of Pulse Durations of Three Recent Experiments

Attosecond pulses in the soft x-ray (SXR) to water-window energy region offer the tools for creating and studying target-specific localized inner-shell electrons or holes in materials, enabling monitoring or controlling charge and energy flows in a dynamic system on attosecond timescales. Recently, a number of laboratories have reported generation of continuum harmonics in the hundred-electron-volt to kilovolt region with few-cycle long-wavelength mid-infrared lasers. These harmonics have the bandwidth to support pulses with durations of a few to a few-ten attoseconds. But harmonics generated in a gas medium have attochirps that cannot be fully compensated by materials over a broad spectral range; thus, realistically what are the typical shortest attosecond pulses that one can generate? To answer this question, it is essential that the temporal attosecond pulses be accurately characterized. By reanalyzing the soft x-ray attosecond metrology reported in three recent experiments using a newly developed broadband phase retrieval algorithm, we demonstrate here that the generated attosecond pulses in the first two papers have durations of about 60 as, longer than what they have reported. Similarly, the duration from the third experiment is retrieved to be about half of the 322-as upper limit cited in that work. We also introduce the autocorrelation (AC) of the streaking spectrogram. By comparing the ACs from the experiments and from the retrieved SXR pulses, the accuracy of the retrieved results can be directly visualized. Our retrieval method is fast and accurate, and it shall provide a powerful tool for the metrology of the emerging few-ten-attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generation of ultrahigh speed, ultrashort flat-top picosecond electrical pulses by laser pulse shaping and ultrafast electro-optics sampling

A novel method is proposed and demonstrated to generate ultrahigh speed, ultrashort flat-top picosecond electrical pulses by combining laser pulse shaping with ultrafast electro-optics sampling technique. Starting with high repetition rate laser pulses, a sequence of birefringent crystals is employed to produce optical pulses with flat-top temporal profile and tunable duration. Subsequent measurement of optical waveforms by an ultrafast photodetector yields high-speed, ultrashort flat-top picosecond electrical pulses. By using two sets of YVO4 crystals for laser pulse shaping, we report on the generation of 704 MHz, 48 picoseconds and 704 MHz, 88 picoseconds flat-top electrical pulses with 16-30 picoseconds rise or fall time. Lastly, to the best of our knowledge, these results are better than or comparable with the best performance using step recovery diodes and the direct electro-optics sampling technique.

43 PARTICLE ACCELERATORS↗

Extracting cavity and pulse phases from limited data for coherent pulse stacking

Coherent pulse stacking (CPS) is a new time-domain coherent addition technique that stacks several optical pulses into a single output pulse, enabling high pulse energy and high average power. A Z-domain model targeting the pulsed laser is assembled to describe the optical interference process. In this study, an algorithm, extracting the cavity phase and pulse phases from limited data, where only the pulse intensity is available, is developed to diagnose optical cavity resonators. We also implement the algorithm on the cascaded system of multiple optical cavities, achieving phase errors less than 1.0°(root mean square), which could ensure the stability of CPS.

42 ENGINEERING↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

Numerical investigation of the effect of the temporal pulse shape on modification of fused silica by femtosecond pulses

We report the results of numerical studies of the impact of asymmetric femtosecond pulses focused in the bulk of the material on the femtosecond modification of fused silica. It is shown that such pulses lead to localisation of absorption in the process of femtosecond modification and to a decrease in the threshold energy of modification. It is found that the optimal asymmetry parameters for reaching the maximum plasma density in the focusing region depend on the pulse energy: at an initial energy of about 100 nJ, it is preferable to use pulses with positive TOD; however, when the energy is increased, it is preferable to use pulses with negative TOD. This is explained by differences in the dynamics of the processes of absorption of energy of a pulse propagating in the material. (optical fibres, lasers and amplifiers. properties and applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing extreme pulsed lasers through measurements: summary of the pulsed laser metrology workshop

In this report we present consensus findings produced during the pulsed laser metrology (PLM) workshop (Boulder, CO, USA, August 2025). The workshop was a meeting of 35 scientists from private industry, academia, and U.S. government to compile a list of the metrology needs to support extreme pulsed laser development and implementation. We define ‘extreme pulsed lasers’ loosely as those with peak powers above 1 TW or multi-Joule pulse energies. Such lasers are being increasingly used and investigated for use in high energy particle acceleration, short wavelength radiation generation, laser-based fusion, etc. The rapid growth of these fields and the proliferation of extreme lasers for these applications, coupled with the extreme electric fields they generate and relative scarcity of such lasers, presents unique challenges to accuracy in their measurement. The PLM workshop was a two-day event designed to hear from users, developers, and researchers on the current state of optical metrology associated with these extreme pulsed lasers. The goal was to identify the most important measurement challenges limiting development and implementation of these lasers in practical applications. We report here the conclusions and recommendations of this workshop. The hope is that this document will become the first of many iterations which track the status of measurement needs supporting extreme pulsed lasers.

Lasers↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic power and chirp measurements of amplified 19 ps pulses in traveling-wave and reflective semiconductor optical amplifiers using a linear pulse characterization technique

The dynamic chirp and power of amplified pulses in semiconductor optical amplifiers is of importance in the application of these devices as conventional amplifiers and in optical signal processing. Non-linear measurement techniques are appropriate for pulsewidths less than 5 ps but have low sensitivity for wider pulsewidths commonly present in moderate bit rate optical systems. Typical measurements of chirp and power of 20 GHz repetition rate amplified 19 ps pulsewidth pulses in traveling-wave and reflective SOAs are obtained using a linear characterization technique based on small-signal sinusoidal modulation at half the pulse stream repetition rate and post-processing of the resulting optical spectrums. The results show that the amplified pulse dynamic power and chirp can have a complex structure and thereby pulse spectrum, which in turn can influence pulse propagation in optical fiber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Artificial neural network algorithms for pulse shape discrimination and recovery of piled-up pulses in organic scintillators

We developed two neural-network (NN)-based algorithms (fully-connected neural network (Fc-NN) and recurrent neural network (RNN)) to perform pulse shape discrimination (PSD) and identification of piled-up pulses produced by organic scintillators, upon interaction with neutrons and gamma rays. We tested the algorithms on measured and verification sets of data and compared their classification performances to standard approaches. At a high acquisition count rate (100,000 counts per second, cps), in the presence of a gamma-to-neutron ratio of approximately 400–1, the proposed NN-based algorithm achieves a fraction of misclassified neutron, gamma, and piled-up pulses of approximately 1%, 1.8%, and 0.6%, respectively. Compared to the traditional approach, it exhibits 3×, 14×, and 11× improved (lower) miscalculation rates for neutron, gamma, and piled-up pulses, respectively. Here, we also demonstrate the capability of NN-based algorithms of successfully recovering and identifying neutron and gamma ray compositions from piled-up pulses in challenging, high pulse count rate conditions.

42 ENGINEERING↗

Kinetics calculation of fast periodic pulsed reactors using MCNP6

Fast periodic pulsed reactor is a type of reactor in which the fission bursts are formed entirely with external reactivity modulation with a specified time periodicity. This type of reactors could generate much larger intensity of neutron beams for experimental use, compared with the steady state reactors. In the design of fast periodic pulsed reactors, the time dependent simulation of the power pulse is majorly based on a point kinetic model, which is known to have limitations. A more accurate calculation method is desired for the design analyses of fast periodic pulsed reactors. Monte Carlo computer code MCNP6 is used for this task due to its three dimensional transport capability with a continuous energy library. Some new routines were added to simulate the rotation of the movable reflector parts in the time dependent calculation. Fast periodic pulsed reactor IBR-2M was utilized to validate the new routines. This reactor is periodically in prompt supercritical state, which lasts for similar to 400 mu s, during the equilibrium state. This generates long neutron fission chains, which requires tremendously large amount of computation time during Monte Carlo simulations. Russian Roulette was applied for these very long neutron chains in MCNP6 calculation, combined with other approaches to improve the efficiency of the simulations. In the power pulse of the IBR-2M at equilibrium state, there is some discrepancy between the experimental measurements and the calculated results using the point kinetics model. MCNP6 results matches better the experimental measurements, which shows the merit of using MCNP6 calculation relative to the point kinetics model.

Zhong, Z.↗

Laser wake-field acceleration in pre-formed plasma channel created by pre-pulse pedestal of terawatt laser pulse

The role of nanosecond duration pre-pulse pedestal (Amplified Spontaneous Emission (ASE) pre-pulse) in the propagation of 45 fs, 4 TW Ti:Sapphire laser pulse through a helium gas jet target has been investigated. We observed that the pre-pulse pedestal of about 1 ns duration and intensity 3 x 10{sup 12} W/cm{sup 2} creates pre-formed plasma with optical guiding channel like structure in the gas-jet at density around 3 x 10{sup 19} cm{sup -3}. Guiding of the 45 fs laser pulse (I{sub L} = 3 x 10{sup 18} W/cm{sup 2}) in the pre-formed plasma channel, over a distance much longer than the Rayleigh length was also observed. The guiding of the laser pulse resulted in the generation of high energy electron beam by laser wake-field acceleration of self-injected electrons. The accelerated electron beam was quasi-monoenergetic with peak energy up to 50 MeV, low divergence in the range of 3-6 mrad, and bunch charge up to 100 pC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser pulse driven terahertz generation via resonant transition radiation in inhomogeneous plasmas

An intense, short laser pulse propagating across a plasma boundary ponderomotively drives THz radiation. Full format PIC simulations and theoretical analysis are conducted to investigate the properties of this radiation. Simulation results which show the THz emission originates in regions of varying density and covers a broad spectrum with maximum frequency close to the maximum plasma frequency. In the case of a sharp vacuum-plasma boundary, the radiation is generated symmetrically at the plasma entrance and exit, and its properties are independent of plasma density when the density exceeds a characteristic value determined by the product of the plasma frequency and the laser pulse duration. For a diffuse vacuum-plasma boundary, the emission from the plasma entrance and exit is asymmetric: increasing and decreasing density ramps enhance and diminish the radiated energy, respectively. Enhancements by a factor of 50 are found and simulations show that a 1.66 J, 50 fs driver pulse can generate ∼400 μJ of THz radiation in a 1.2 mm increasing density ramp. We present a model that attributes this effect to a plasma resonance process in the density ramp. The results from the model match those of the simulations for ramp lengths less than 600 μm. For longer ramps for which simulations are too time consuming, the model shows that the amount of radiation reaches a maximum at a ramp length determined by collisional absorption.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual moderator studies for the Spallation Neutron Source short-pulse second target station

Candidate moderator configurations for a short-pulse second target station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) have been identified using a global optimizer framework built around the MCNPX particle transport code. Neutron brightness metrics were selected as the figure-of-merit. We assumed that STS would use one out of six proton pulses produced by an SNS accelerator upgraded to operate at 1.3 GeV proton energy, 2.8 MW power and 60 Hz repetition rate. The simulations indicate that the peak brightness can be increased by a factor of 5 and 2.5 on a per proton pulse basis compared to the SNS first target station for both coupled and decoupled para-hydrogen moderators, respectively. Additional increases by factors of 3 and 2 were demonstrated for coupled and decoupled moderators, respectively, by reducing the area of neutron emission from 100 × 100 mm{sup 2} to 20 × 20 mm{sup 2}. This increase in brightness has the potential to translate to an increase of beam intensity at the instruments’ sample positions even though the total neutron emission of the smaller moderator is less than that of the larger. This is especially true for instruments with small samples (beam dimensions). The increased fluxes in the STS moderators come at accelerated poison and de-coupler burnout and higher radiation-induced material damage rates per unit power, which overall translate into lower moderator lifetimes. A first effort was undertaken to group decoupled moderators into a cluster collectively positioning them at the peak neutron production zone in the target and having a three-port neutron emission scheme that complements that of a cylindrical coupled moderator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction

Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. Additionally, the system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10 7 molybdenum Kα photons.

47 OTHER INSTRUMENTATION↗

Compression of pulses during their amplification in the field of a focused counterpropagating pump pulse of the same frequency and width in media with electrostriction nonlinearity

Efficient compression of focused {approx}0.9-ns pulses of a miniature Nd:YAG laser to less than 60 ps is experimentally obtained at their interaction with counterpropagating pulses of the same carrier frequency and width in CCl{sub 4}. In this case, electrostriction interaction (amplification) begins not from the level of spontaneous-scattering noise; therefore, the counterpropagating pulses can be compressed at pump pulse energies below the stimulated Brillouin scattering (SBS) threshold energies. When counterpropagating seed pulses are used, the energy and temporal stability of compressed pulses are several times higher, and their time jitter is smaller than that for SBS compression from the level of spontaneous-scattering noise. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Er/Yb fibre laser system for generating few-cycle 1.6 to 2.0 {mu}m pulses optically synchronised with high-power pulses near 1 {mu}m

This paper presents the concept of fibre laser system design for generating optically synchronised femtosecond pulses at two, greatly differing wavelengths and reports experimental and numerical simulation studies of nonlinear conversion of femtosecond pulses at 1.5 {mu}m wavelength in a dispersion-shifted fibre, with the generation of synchronised pulses in the ranges 1.6 - 2 and 1 - 1.1 {mu}m. We describe a three-stage high-power fibre amplifier of femtosecond pulses at 1 {mu}m and a hybrid Er/Yb fibre laser system that has enabled the generation of 12 fs pulses with a centre wavelength of 1.7 {mu}m, synchronised with high-power (microjoule level) 250 fs pulses at 1.03 {mu}m. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power limitations and pulse distortions in an Yb : KGW chirped-pulse amplification laser system

We have studied self-action effects (self-focusing and self-phase modulation) and stimulated Raman scattering in an Yb : KGW chirped-pulse amplification laser system. The results demonstrate that self-focusing in combination with thermal lensing may significantly limit the chirped pulse energy in this system (down to 200 μJ) even at a relatively long pulse duration (50 ps). Nonlinear lenses in the laser crystals in combination with thermal lenses bring the regenerative amplifier cavity in the laser system to the instability zone and limit the average output power at pulse repetition rates under 50 kHz. Self-phase modulation, a manifestation of self-action, may significantly distort a recompressed femtosecond pulse at energies near the self-focusing threshold. Stimulated Raman scattering in such a laser has a weaker effect on output parameters than do self-focusing and thermal lensing, and Raman spectra are only observed in the case of pulse energy instability. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-optic time lensing with an intense single-cycle terahertz pulse

We demonstrate that an intense single-cycle terahertz (THz) pulse can act as a time lens to phase modulate and compress a copropagating ultrashort laser pulse. By using the THz-induced phase modulation as a time lens and a glass plate as a group velocity dispersive element, we have compressed an unchirped {approx}165 fs laser pulse to {approx}45 fs.

43 PARTICLE ACCELERATORS↗