Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Polymer deformation gage measures thickness change in tensile tests

Lightweight deformation gage attached to a polymer specimen determines the thickness changes undergone by the specimen during the testing of its tensile and elongation properties. Mechanical noise from outside sources is dampened when the assembly is hung on a light rubber band.

Broyles, H. F.↗

Mechanical Tensile Testing of Hiperco 50A at Cryogenic Temperature

Hiperco 50A is a highly desired material for use in cryogenic applications, specifically for adiabatic demagnetization refrigerators (ADRs) due to its magnetic field shielding capabilities. Although the alloy has good strength, there is a concern with the material's brittle behavior which is believed to worsen at low temperature based on previous tests. The testing described here investigates the mechanical properties of Hiperco 50A at cryogenic temperature through mechanical tensile testing to failure and evaluation of the failed coupons. The methods and techniques used to determine the elongation, yield strength, ultimate tensile strength, and break strength of the material as well as the results will be presented here.

material properties↗

In Situ Tensile Testing of Single Crystal Molybdenum Alloy Fibers with Various Dislocation Densities in a Scanning Electron Microscope

In-situ tensile tests have been performed in a dual beam focused ion beam and scanning electron microscope on as-grown and prestrained single-crystal molybdenum-alloy (Mo-alloy) fibers. The fibers had approximately square cross sections with submicron edge lengths and gauge lengths in the range of 9-41 {mu}m. In contrast to previously observed yield strengths near the theoretical strength of 10 GPa in compression tests of {approx}1-3-{mu}m long pillars made from similar Mo-alloy single crystals, a wide scatter of yield strengths between 1 and 10 GPa was observed in the as-grown fibers tested in tension. Deformation was dominated by inhomogeneous plastic events, sometimes including the formation of Lueders bands. In contrast, highly prestrained fibers exhibited stable plastic flow, significantly lower yield strengths of {approx}1 GPa, and stress-strain behavior very similar to that in compression. A simple, statistical model incorporating the measured dislocation densities is developed to explain why the tension and compression results for the as-grown fibers are different.

36 MATERIALS SCIENCE↗

Tensile testing of materials at high temperatures above 1700 °C with in situ synchrotron X-ray micro-tomography

A compact ultrahigh temperature tensile testing instrument has been designed and fabricated for in situ x-ray micro-tomography using synchrotron radiation at the Advanced Light Source, Lawrence Berkeley National Laboratory. It allows for real time x-ray micro-tomographic imaging of test materials under mechanical load at temperatures up to 2300 °C in controlled environments (vacuum or controlled gas flow). Sample heating is by six infrared halogen lamps with ellipsoidal reflectors arranged in a confocal configuration, which generates an approximately spherical zone of high heat flux approximately 5 mm in diameter. Samples are held between grips connected to a motorized stage that loads the samples in tension or compression with forces up to 2.2 kN. The heating chamber and loading system are water-cooled for thermal stability. The entire instrument is mounted on a rotation stage that allows stepwise recording of radiographs over an angular range of 180°. A thin circumferential (360°) aluminum window in the wall of the heating chamber allows the x-rays to pass through the chamber and the sample over the full angular range. The performance of the instrument has been demonstrated by characterizing the evolution of 3D damage mechanisms in ceramic composite materials under tensile loading at 1750 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus for high-throughput sequential tensile testing and methods thereof

The present invention relates, in part, to an apparatus configured to test a plurality of test samples within a sample cartridge. Such an apparatus can facilitate high-throughput tensile testing of such test samples. Also described herein are methods for using such an apparatus and for testing such test samples.

Boyce, Brad↗

Manual for LDEF tensile tests

One of the experiments aboard the NASA Long Duration Exposure Facility (LDEF) consists of a tray of approximately one hundred tensile specimens of several candidate space structure composite materials. During the LDEF flight the materials will be subjected to the space environment and to possible contamination during launch and recovery. Tensile tests of representative samples were made before the LDEF flight to obtain baseline data. Similar tests will be made on control specimens stored on earth for the length of the LDEF flight and on recovered flight specimens. This manual codifies the details of testing, data acquisition, and handling used in obtaining the baseline data so that the same procedures and equipment will be used on the subsequent tests.

Witte, W. G., Jr.↗

Interaction of heat production, strain rate and stress power in a plastically deforming body under tensile test

At high strain rates the heat produced by plastic deformation can give rise to a rate dependent response even if the material has rate independent constitutive equations. This effect has to be evaluated when interpreting a material test, or else it could erroneously be ascribed to viscosity. A general thermodynamic theory of tensile testing of elastic-plastic materials is given in this paper; it is valid for large strain at finite strain rates. It enables discovery of the parameters governing the thermodynamic strain rate effect, provides a method for proper interpretation of the results of the tests of dynamic plasticity, and suggests a way of planning experiments in order to detect the real contribution of viscosity.

Paglietti, A.↗

Effect of thermomechanical processing on the microstructure and retained austenite stability during in situ tensile testing using synchrotron x-ray diffraction of NbMoAI TRIP steel.

In this work we compare and contrast the stability of retained austenite during tensile testing of Nb-Mo-Al transformation-induced plasticity steel subjected to different thermomechanical processing schedules. The obtained microstructures were characterised using optical metallography, transmission electron microscopy and X-ray diffraction. The transformation of retained austenite to martensite under tensile loading was observed by in-situ high energy X-ray diffraction at 1ID / APS. It has been shown that the variations in the microstructure of the steel, such as volume fractions of present phases, their morphology and dimensions, play a critical role in the strain-induced transition of retained austenite to martensite.

36 MATERIALS SCIENCE↗

Lattice strain and damage evolution of 9-12/%Cr ferritic/martensitic steel during in situ tensile test by x-ray diffraction and small angle scattering.

In situ X-ray diffraction and small angle scattering measurements during tensile tests were performed on 9-12% Cr ferritic/martensitic steels. The lattice strains in both particle and matrix phases, along two principal directions, were directly measured. The load transfer between particle and matrix was calculated based on matrix/particle elastic mismatch, matrix plasticity and interface decohesion. In addition, the void or damage evolution during the test was measured using small angle X-ray scattering. By combining stress and void evolution during deformation, the critical interfacial strength for void nucleation was determined, and compared with pre-existing void nucleation criteria. These comparisons show that models overestimate the measured critical strength, and require a larger particle size than measured to match the X-ray observations.

36 MATERIALS SCIENCE↗

Correlating dislocation structures to basal and prismatic slip bands near grain boundaries in tensile-tested Mg–4Al using a multiscale electron microscopy approach

Dislocation structures where basal and prismatic slip bands meet grain boundaries in tensile-tested Mg with 4 wt% Al (Mg–4Al) were studied using a multiscale electron microscopy approach to explore the assumptions made for the dislocation pileup theory: a) slip bands consist of dislocation arrays piling up near grain boundaries, and b) stress concentration in the adjacent grain is solely caused by dislocation pileup. After post-testing electron backscatter diffraction (EBSD) scans, focused-ion-beam (FIB) lift-out specimens were prepared from regions of interest so that the specimen plane is parallel to the bulk sample surface to allow for direct correlation between mesoscale and microscale characterization. High dislocation density and the dislocation arrays in the slip bands corroborated with the first assumption. Evidence of plastic deformation in all grains, however, showed that the second assumption was false. Additionally, dislocation structures including crystal rotation boundaries and dislocations dissociating to the basal plane provide additional stress relief mechanisms near grain boundaries that are not accounted for in many crystal plasticity models, which requires auxiliary models to more accurately predict the stress and strain distribution in a microstructure.

36 MATERIALS SCIENCE↗

Modifications of system for elevated temperature tensile testing and stress-strain measurement of metal matrix composites

Composites consisting of tungsten alloy wires in superalloy matrices are being studied because they offer the potential for increased strength compared to current materials used at temperatures up to at least 1093 C (2000F). Previous research at the NASA Lewis Research Center and at other laboratories in the U.S., Europe, and Japan has demonstrated laboratory feasibility for fiber reinforced superalloys (FRS). The data for the mechanical and physical properties used to evaluate candidate materials is limited and a need exists for a more detailed and complete data base. The focus of this work is to develop a test procedure to provide a more complete FRS data base to quantitatively evaluate the composite's potential for component applications. This paper will describe and discuss the equipment and procedures under development to obtain elevated temperature tensile stress-strain, strength and modulus data for the first generation of tungsten fiber reinforced superalloy composite (TFRS) materials. Tensile stress-strain tests are conducted using a constant crosshead speed tensile testing machine and a modified load-strain measuring apparatus. Elevated temperature tensile tests are performed using a resistance wound commercial furnace capable of heating test specimens up to 1093 C (2000 F). Tensile stress-strain data are obtained for hollow tubular stainless steel specimens serving as a prototype for future composite specimens.

Diaz, J. O.↗

A microdynamic version of the tensile test machine

Very large space structures require structural reactions to control forces associated with nanometer-level displacements; JPL has accordingly built a tensile test machine capable of mN-level force measurements and nm-level displacement measurements, with a view to the study of structural linear joining technology at the lower limit of its resolution. The tester is composed of a moving table that is supported by six flexured legs and a test specimen cantilevered off the table to ground. Three vertical legs contain piezoactuators allowing changes in length up to 200 microns while generating axial load and bending moments. Displacements between ground and table are measured by means of three laser-interferometric channels.

Glaser, R. J.↗

Effect of lateral contraction and magnetism on the energy release upon fracture in metals: First-principles computational tensile tests

On many occasions, there is an energy release upon fracture of materials. Taking the {sigma}5 (210) grain boundary in nickel as an example, we have studied the effect of lateral contraction (the Poisson effect) upon stretching and the effect of magnetism on the energy release at the break point, using density-functional theory computational tensile tests. For both clean and sulfur segregated grain boundaries, our calculations show that the Poisson effect can reduce the total energy of the grain-boundary system remarkably. For {sigma}3 (111) grain boundary, however, lateral optimization of the computation cell has only a minor effect because of the close packing of the Ni (111) plane. Surprisingly, magnetism is found to reduce much of the energy release upon fracture for grain boundaries for such a weak magnetic metal. As a result, the calculated ultimate tensile strength of the material will be significantly diminished. Segregated sulfur atoms reduce the energy barrier between metastable and ground-state configurations in straining procedure. Near the break point, spin polarization of the interfacial atoms is significantly enhanced which introduces an extra energy lowering of the system.

36 MATERIALS SCIENCE↗

Mechanical properties of individual InAs nanowires studied by tensile tests

Mechanical properties of individual InAs nanowires (NWs) synthesized by metal organic chemical vapor deposition (MOCVD) and molecular beam epitaxy (MBE) methods are studied by in-situ tensile tests in a scanning electron microscope and their fracture strength and Young's modulus are obtained. The two types of NWs both exhibit brittle fracture with a maximum elastic strain up to ∼10%. Their fracture strength distributes in a similar range of ∼2–5 GPa with a general trend of increasing with NW volume decrease, which is well described by Weibull statistic with a smaller Weibull modulus and a higher characteristic strength for MOCVD NWs. Young's modulus is determined to be 16–78 GPa with an average value of 45 GPa and no dependence on NW diameter for MOCVD NWs and 34–79 GPa with an average value of 58 GPa for MBE NWs.

36 MATERIALS SCIENCE↗

Direct comparison of nanoindentation and tensile test results on reactor-irradiated materials

Nanoindentation testing has been used for decades to assess materials on a local scale and to obtain fundamental mechanical property parameters. Nuclear materials research often faces the challenge of testing rather small samples due to the hazardous nature, limited space in reactors, and shallow ion-irradiated zones, fostering the need for small-scale mechanical testing (SSMT). As such, correlating the results from SSMT to bulk properties is particularly of interest. Here, this study compares macroscopic tensile test data (yield and flow stresses) to nanoindentation data (hardness) obtained on a number of different neutron-irradiated materials in order to understand the scaling behavior on radiation-damaged samples.

36 MATERIALS SCIENCE↗

Optical strain measuring techniques for high temperature tensile testing

A number of optical techniques used for the analysis of in-plane displacements or strains are reviewed. The application would be for the high temperature, approximately 1430 C (2600 F), tensile testing of ceramic composites in an oxidizing atmosphere. General descriptions of the various techniques and specifics such as gauge lengths and sensitivities are noted. Also, possible problems with the use of each method in the given application are discussed.

Gyekenyesi, John Z.↗

Emerging hierarchical dislocation structures: Insights from scanning electron microscopy-electron backscatter diffraction in situ tensile testing and multifractal analysis

Understanding the evolution of dislocation structures during plastic deformation is critical for predicting the mechanical performance of metallic materials. In this work, we applied in situ scanning electron microscopy/electron backscatter diffraction tensile testing combined with multifractal (MF) analysis to assess deformation-induced dislocation structure evolution in solution-annealed 304 L stainless steel, both in its as-received and neutron-irradiated states (5.4 displacements per atom). The analysis of kernel average misorientation patterns revealed the formation of hierarchical dislocation arrangements that exhibit clear MF scaling behavior. Despite pronounced visual differences between nonirradiated and irradiated specimens—most notably, the appearance of dislocation channels after irradiation—the singularity spectra suggest that both conditions give rise to similar underlying hierarchical structures. MF analysis provides a quantitative measure of the spatial complexity and self-organization of dislocation patterns, highlighting the accelerated emergence and evolution of the dislocation structures in irradiated polycrystalline materials, as well as the limitation of their spatial extent. The findings indicate that irradiation not only modifies microstructure but also alters correlation-driven dislocation organization. More generally, they demonstrate that MF analysis is a powerful tool for probing mesoscale deformation mechanisms.

Dislocation structures↗

Analysis of Sandwich Shells with Metallic Foam Cores based on the Uniaxial Tensile Test

On this work, the authors present the development and evaluation of an innovative system able to perform reliable panels of sandwich sheets with metallic foam cores for industrial applications, especially in automotive and aeronautical industries. This work is divided into two parts; in the first part the mathematical model used to describe the behavior of sandwich shells with metal cores form is presented and some numerical examples are presented. In the second part of this work, the numerical results are validated using the experimental results obtained from the mechanical experiments. Using the isotropic hardening crushable foam constitutive model, available on ABAQUS, a set of different mechanical tests were simulated. The isotropic hardening model available uses a yield surface that is an ellipse centered at the origin in the p-q stress plane. Using this constitutive model, the uniaxial tensile test for this material was simulated, and a comparison with the experimental results was made.

36 MATERIALS SCIENCE↗