Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ASRDI oxygen technology survey. Volume 4: Low temperature measurement

Information is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations.

Sparks, L. L.↗

Pressure and temperature measurement in supercharger investigations

With the further development of the supercharger, requirements with regard to measuring accuracy increase while at the same time the conditions under which the measurements must be carried out become more difficult. The present paper is a contribution toward the improvement and refinement of the measuring methods. For pressure measurements some suggestions are made with regard to design and location of the measuring stations. The question of temperature measurement in rapid air flow is discussed, new instruments for the direct measurement of the temperature in the rapid airstream are described and the results obtained with the various instruments presented.

Franz, A↗

Thin-Filament Pyrometry Developed for Measuring Temperatures in Flames

Many valuable advances in combustion science have come from observations of microgravity flames. This research is contributing to the improved efficiency and reduced emissions of practical combustors and is benefiting terrestrial and spacecraft fire safety. Unfortunately, difficulties associated with microgravity have prevented many types of measurements in microgravity flames. In particular, temperature measurements in flames are extremely important but have been limited in microgravity. A novel method of measuring temperatures in microgravity flames is being developed in-house at the National Center for Microgravity Research and the NASA Glenn Research Center and is described here. Called thin-filament pyrometry, it involves using a camera to determine the local gas temperature from the intensity of inserted fibers glowing in a flame. It is demonstrated here to provide accurate measurements of gas temperatures in a flame simultaneously at many locations. The experiment is shown. The flame is a laminar gas jet diffusion flame fueled by methane (CH4) flowing from a 14-mm round burner at a pressure of 1 atm. A coflowing stream of air is used to prevent flame flicker. Nine glowing fibers are visible. These fibers are made of silicon carbide (SiC) and have a diameter of 15 m (for comparison, the average human hair is 75 m in diameter). Because the fibers are so thin, they do little to disturb the flame and their temperature remains close to that of the local gas. The flame and glowing filaments were imaged with a digital black-and-white video camera. This camera has an imaging area of 1000 by 1000 pixels and a wide dynamic range of 12 bits. The resolution of the camera and optics was 0.1 mm. Optical filters were placed in front of the camera to limit incoming light to 750, 850, 950, and 1050 nm. Temperatures were measured in the same flame in the absence of fibers using 50-m Btype thermocouples. These thermocouples provide very accurate temperatures, but they generally are not useful in microgravity tests because they measure temperature at only one location at a time. Thermocouple measurements at a height of 11 mm above the burner were used to calibrate the thin-filament pyrometry system at all four wavelengths. This calibration was used to perform thin-filament pyrometry at other heights above the burner. One such profile is shown in this graph; this is for a height of 21 mm. The agreement between the pyrometry measurements and thermocouple results at this height is excellent in the range of 1000 to 2000 K, with an estimated uncertainty of 50 K and an estimated upper limit of 2500 K. Neither the thermocouple nor the thin-filament pyrometry temperatures have been corrected for radiation, but the correction is expected to be nearly the same for both methods. We anticipate that thin-filament pyrometry similar to that developed here will become an important diagnostic for studies of microgravity flames owing to its accuracy and its ability to simultaneously measure finely spaced temperatures.

Sunderland, Peter B.↗

Non-contact temperature measurement of a falling drop

The 105 meter drop tube at NASA-Marshall has been used in a number of experiments to determine the effects of containerless, microgravity processing on the undercooling and solidification behavior of metals and alloys. These experiments have been limited, however, because direct temperature measurement of the falling drops has not been available. Undercooling and nucleation temperatures are calculated from thermophysical properties based on droplet cooling models. In most cases these properties are not well known, particularly in the undercooled state. This results in a large amount of uncertainty in the determination of nucleation temperatures. If temperature measurement can be accomplished then the thermal history of the drops could be well documented. This would lead to a better understanding of the thermophysical and thermal radiative properties of undercooled melts. An effort to measure the temperature of a falling drop is under way. The technique uses two color pyrometry and high speed data acquisition. The approach is presented along with some preliminary data from drop tube experiments. The results from droplet cooling models is compared with noncontact temperature measurements.

Hofmeister, William↗

Surface temperature measurements using a thin film thermal array

A thin film device was designed and fabricated to measure surface temperatures. An array of eight integrated thermal sensors are mounted on a 0.002 inch (0.05 mm) Kapton film and multiplexed to obtain an area thermal measurement. The device was tested on a flat plate airfoil and demonstrated a temperature variation of 0.55 C maximum and 0.05 C minimum compared to embedded thermocouples. Future improvements are also discussed.

Dillon-Townes, L. A.↗

Development of a fs/Ps CARS System for Temperature Measurements Within Supersonic and Hypersonic Environments

A hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system was developed for quantitative measurements of temperature in a laboratory-scale supersonic jet facility. Measurements were recorded at low pressures and densities relevant for supersonic and hypersonic environments, with special interest in exploring the feasibility of deploying this technique in the 20-inch Mach 6 and 31-inch Mach 10 wind tunnels located at NASA Langley Research Center. Modifications to the existing supersonic jet facility were made to simulate a test section with a width of 31 inches, so that the size of the test section is relevant for either wind tunnel. The CARS system was designed such that a similar beam geometry can be used in the laboratory to acquire point-based fs/ps CARS measurements along two axes of translation. Rotational Raman transitions of O 2 and N 2 were targeted.

CARS↗

Development of a fs/ps CARS System for Temperature Measurements in Supersonic and Hypersonic Environments

A hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system was developed for quantitative measurements of temperature in a laboratory-scale supersonic jet facility. Measurements were recorded at low pressures and densities relevant for supersonic and hypersonic environments, with special interest in exploring the feasibility of deploying this technique in the 20-inch Mach 6 and 31-inch Mach 10 wind tunnels located at NASA Langley Research Center. Modifications to the existing supersonic jet facility were made to simulate a test section with a width of 31 inches, so that the size of the test section is relevant for either wind tunnel. The CARS system was designed such that a similar beam geometry can be used in the laboratory to acquire point-based fs/ps CARS measurements along two axes of translation. Rotational Raman transitions of O 2 and N 2 were targeted.

CARS↗

Design and simulated performance of a CARS spectrometer for dynamic temperature measurements using electronic heterodyning

A new design for generating CARS signals and for the detection and processing of these signals is presented and evaluated. The design is based on electronic heterodyning of the CARS spectrum of nitrogen at two selected narrowband frequencies, ratioing the resulting signal strengths, and comparing this ratio with a theoretically derived temperature scale. A reference cell is incorporated into the design for system calibration and for accurate temperature measurements. The spectrometer is found capable of measuring temperature in the submillisecond time scale with an accuracy of 10 percent in the 1000-2000 K temperature range. A typical result using the Hg(x)Cd(1-x)Te photomixer for T = 1500 K, Delta T = 50 K is a SNR of 21 dB and a data collection rate of 300 Hz.

Deen, M. Jamal↗

CARS Temperature Measurements in Turbulent and Supersonic Facilities

This paper documents the development of the National Aeronautics and Space Administration s (NASA) Langley Research Center ( LaRC) Coherent Antistokes Raman Spectroscopy (CARS) systems for measurements of temperature in a turbulent subsonic or supersonic reacting hydrogen-air environment. Spectra data provides temperature data when compared to a precalculated library of nitrogen CARS spectra. Library validity was confirmed by comparing CARS temperatures derived through the library with three different techniques for determination of the temperature in hydrogen-air combustion and an electrically heated furnace. The CARS system has been used to survey temperature profiles in the simulated flow of a supersonic combustion ramjet (scramjet) model. Measurement results will be discussed.

Jarrett, O., Jr.↗

Temperature Measurement of a Glass Material Using a Multiwavelength Pyrometer

Temperature measurement of a substance that is transparent using the traditional 1-color, 2-color and other pyrometers has been difficult. The radiation detected by pyrometers do not come from a well defined location in the transparent body. The multiwavelength pyrometer developed at the NASA Lewis Research Center can measure the surface temperature of many materials. We show in this paper that it also measures the surface and a bulk subsurface temperature of transparent materials like glass.

Ng, Daniel↗

High data density temperature measurement for quasi steady-state flows

A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermocouple and the two data sets show excellent agreement This instrument maintains the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction.

Mercer, Carolyn R.↗

High Data Density Temperature Measurement for Quasi Steady-State Flows

A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermo-couple and the two data sets show excellent agreement. This instrument maintains the compact, robust design of Linniks point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts with very high data density and with automated data reduction.

Mercer, C. R.↗