Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRIGGER LOGIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3 He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252 Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Open questions: The disrupted circuitry of the cancer cell

Every new decade of biology brings with it a change in outlook driven by new technologies and fresh perspectives. Such is the case for cancer and how we consider the disease. The advent of molecular biology led to the identification of altered signaling molecules and 'oncogenes' that were proposed to drive uncontrolled cell proliferation. The rise of cell biology and new imaging and culturing technologies led to the idea that disruptions in the extracellular environment prime cells for transformation. In the current genomics era, cancer is most commonly seen as a genetic disorder where an unstable genome gives rise to a variety of different cell variants that are selected for proliferation and survival. All of these views are partially correct, of course, and are simply different ways of saying that genetic alterations in cancer cells result in a loss of growth homeostasis. They also take the view that molecular changes 'drive' a cell to grow uncontrollably, rather than tip the balance from one normal state (quiescence) to another (proliferation). Underlying this oversimplification is a profound ignorance of what controls homeostatic cell growth in the first place and how specific mutations impact it.

cancer↗

Orion Artemis I Descent and Landing Performance

The Artemis I mission successfully demonstrated the Orion Multi-Purpose Crew Module ability to trigger parachute deployment, control angular rate and touch-down heading using reaction control jets while under parachutes, and automatically detect splashdown. Guidance and control logic is implemented to initiate para-chute events in a favorable dynamic state and select a touchdown heading direction that will minimize impact loads at splashdown. Detection of splashdown inhibits control to prevent firing reaction control jets under water and begin the transition into post-landing activities that cut parachutes and deploy the Crew Module Up-righting System (CMUS). This paper presents analysis of Orion descent and landing guidance and control performance for the Artemis I mission utilizing imagery taken from the vehicle, recorded flight data, and results from high fidelity simulations.

Artemis 1↗

Wide Range SET Pulse Measurement

A method for measuring a wide range of SET pulses is demonstrated. Use of dynamic logic, faster than ordinary CMOS, allows capture of short pulses. A weighted binning of SET lengths allows measurement of a wide range of pulse lengths with compact circuitry. A pulse-length-conservative pulse combiner tree routes SETs from combinational logic to the measurement circuit, allowing SET measurements in circuits that cannot easily be arranged in long chains. The method is applied to add-multiplex combinational logic, and to an array of NFET routing switches, at .35 micron. Pulses are captured in a chain of Domino Logic AND gates. Propagation through the chain is frozen on the trailing edge by dropping low the second "enable" input to the AND gates. Capacitive loading is increased in the latter stages to create an approximately logarithmic weighted binning, so that a broad range of pulse lengths can be captured with a 10 stage capture chain. Simulations show pulses can be captured which are 1/5th the length of those typically captured with leading edge triggered latch methods, and less than the length of those captured with a trailing edge latch method. After capture, the pulse pattern is transferred to an SEU protected shift register for readout. 64 instances of each of two types of logic are used as targets. One is a full adder with a 4 to 1 mux on its inputs. The other is a 4 x 4 NFET routing matrix. The outputs are passed through buffered XNOR comparators to identify pulses, which are merged in a buffered not-nand (OR) tree designed to avoid pulse absorption as much as possible. The output from each of the two test circuits are input into separate pulse measurement circuits. Test inputs were provided so that the circuit could be bench tested and calibrated. A third SET measurement circuit with no inputs was used to judge the contribution from direct hits on the measurement circuit. Heavy ions were used with an LET range from 12 to 176. At LET of 21 and below, the very small number of SETs were not significantly higher in the test over the control circuits. At higher LET the test circuit SETs are one or two orders of magnitude greater than for the control circuit. The NFET circuit produces more and slightly longer SETs as expected. But the differences do not appear to be significant enough to modify strategies now used to avoid capture of SETs in chips such as FPGAs. Complete data and graphs will be in the full paper / presentation. In the summary figure below left, NOCL is the reference circuit without any input, and number of stages triggered is plotted. Simulation at right shows the smallest pulse captured (stage 2) at about 300 ps. Our conclusion is that the method is promising, but that improvements in the merge network are desirable before applying in a deep submicron process

Shuler, Robert L.↗

Conditional guide RNA deactivation by mRNA and small molecule triggers in Saccharomyces cerevisiae

CRISPR interference (CRISPRi) technologies have revolutionized bioengineering by providing precise tools for gene expression modulation, enabling targeted gene perturbation and metabolic pathway optimization. Despite these advances, achieving dynamic control over gene expression by CRISPR-based regulation remains a challenge due to its inherently static nature. Utilizing toehold-mediated strand displacement and ligand-responsive ribozymes (aptazymes), this study introduces switchable guide RNAs (gRNAs) that facilitate tunable gene expression mediated by mRNA or small molecule signals. We demonstrate complete silencing of gRNA via strategically designed 5’ or 3’ extensions that impede the gRNA spacer or the dCas9 handle, with subsequent restoration of function through sequestration or cleavage of the obstructive sequence. The resulting toehold-embedded or aptazyme-embedded gRNAs can be deactivated by specific signals, including two full-length translatable mRNAs and two small molecule triggers, thereby lifting CRISPRi repression on targeted genes. This modular approach allows for gRNA-based biocomputing through multi-layer or multi-input genetic logic gates in Saccharomyces cerevisiae . Offering a versatile strategy for post-CRISPR regulation in response to environmental signals or cellular states, this methodology expands the toolkit in eukaryotic systems for reversible control of gene expression.

Aptazyme↗

Dragonfly Preparation for Powered Flight: Lander Separation State Control to Ensure Successful Landing

NASA’s Dragonfly mission, led by The Johns Hopkins University Applied Physics Laboratory, is a relocatable octocopter lander to study Saturn’s largest moon Titan. The scientific goals of the mission include studying Titan’s prebiotic chemistry, geology, and atmosphere. Upon Titan arrival, the lander will enter the atmosphere, descend on a parachute to a ground-relative altitude of about 1000 m before being released, and then fly on internal power down to the surface. To guarantee desirable initial conditions for the lander release, the lander must meet certain angular rate conditions. These conditions include reducing the spin rate about the vertical axis to 4.9 deg/sec, using the rotors as actuators; and releasing with a negative pitch rate (rotating nose down) to ensure a successful transition to powered flight. This is achieved using a release trigger. Achieving these desired rates for lander release is part of the mission phase known as ‘preparation for powered flight’ (PPF). This paper proposes controls and logic to achieve the desired conditions for releasing the lander from the parachute.

Flight Mechanics↗

Dragonfly Preparation for Powered Flight: Lander Separation State Control to Ensure Successful Landing

NASA’s Dragonfly mission, led by The Johns Hopkins University Applied Physics Laboratory, is a relocatable octocopter lander to study Saturn’s largest moon Titan. The scientific goals of the mission include studying Titan’s prebiotic chemistry, geology, and atmosphere. Upon Titan arrival, the lander will enter the atmosphere, descend on a parachute to a ground-relative altitude of about 1000 m before being released, and then fly on internal power down to the surface. To guarantee desirable initial conditions for the lander release, the lander must meet certain angular rate conditions. These conditions include reducing the spin rate about the vertical axis to 4.9 deg/sec, using the rotors as actuators; and releasing with a negative pitch rate (rotating nose down) to ensure a successful transition to powered flight. This is achieved using a release trigger. Achieving these desired rates for lander release is part of the mission phase known as ‘preparation for powered flight’ (PPF). This paper proposes controls and logic to achieve the desired conditions for releasing the lander from the parachute.

Flight Mechanics↗

FPGA/ASIC framework and method for requirements-based trust assessment

Described herein are various technologies for metrics-based assessment and trust verification of netlists for hardware logic devices (e.g., ASICs, FPGAs, etc.). A computing system translates a netlist of a hardware logic device into a Boolean network. The computing system generates and assigns metrics to edges of the Boolean network. The metrics comprise a coverage metric, a rare trigger metric, and an influence metric. Based upon the metrics, the computing system assigns the nodes in the Boolean network criticality values. The computing system determines a likelihood of a vulnerability in the netlist based upon the criticality values. The computing can output an indication as to whether the netlist is trusted based upon the determined likelihood of a vulnerability in the netlist.

97 MATHEMATICS AND COMPUTING↗

Signal processing in the neutral-trigger system of the CMD-3 detector

A method for calorimeter-signal processing intended for deriving input signals for the neutral trigger is considered. An algorithm for digitizing signals is described in detail, along with a simulation of its operation. A brief account of data obtained in tests of a prototype of the signal-processing module that employs the developed algorithm is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-Flight EDL Entry Guidance Performance for the 2011 Mars Science Laboratory Mission

Mars Science Laboratory landed Curiosity in Gale Crater on 5 Aug 2012. Curiosity landed successfully only 2.2 km away from the expected target given the onboard navigation state. Better than the average Apollo capsule splashdown miss distance. A late bank reversal and a suspected tail wind contributed to this slight miss. Entry guidance is derived from the Apollo capsule "final phase" logic and adjusts the range flown during entry by varying the direction of the lift vector (i.e., bank angle). Refinement of the guidance gains and alternative parachute deploy triggers to reduce the ellipse size will be studied for future Mars landing missions.

Mendeck, G.↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

A multi-layer SEU mitigation strategy to improve FPGA design robustness for the ATLAS muon spectrometer upgrade

We present a multi-layer single-event upset mitigation strategy implemented in a low-cost Xilinx Artix-7 FPGA. The implementation is targeted for a trigger data router for the ATLAS muon spectrometer upgrade. The mitigation strategy employs three layers of protection to improve overall FPGA design robustness: use of triple-modular redundancy for FPGA fabric logic and embedded soft-error mitigation in the first layer; further enhancement with multi-boot FPGA reconfiguration across multiple copies of configuration memory in the second layer; and FPGA power cycling and configuration memory re-initialization in the third layer. Here, the effectiveness of this scheme has been evaluated at two different neutron facilities, LANSCE and NCSR ‘‘Demokritos’’, with 800 MeV and 25 MeV beam energies, respectively. Testing was performed with a similar configuration to that planned for final operation. We discuss the testing strategy and summarize the test results to estimate the expected data loss over 10 years of operation in the ATLAS experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First GRB detections with the AGILE Minicalorimeter

The Minicalorimeter (MCAL) onboard the AGILE satellite is a 1400 cm{sup 2} scintillation detector sensitive in the energy range 0.3-200 MeV. MCAL works both as a slave of the AGILE Silicon Tracker and as an autonomous detector for transient events (BURST mode). A dedicated onboard Burst Search logic scans BURST mode data in search of count rate increase. Peculiar characteristics of the detector are the high energy spectral coverage and a timing resolution of about 2 microseconds. Even if a trigger is not issued, BURST mode data are used to build a broad band energy spectrum (scientific ratemeters) organized in 11 bands for each of the two MCAL detection planes, with a time resolution of 1 second. After the first engineering commissioning phase, following the AGILE launch on 23rd April 2007, between 22nd June and 5th November 2007 eighteen GRBs were detected offline in the scientific ratemeters data, with a detection rate of about one per week. In this paper the capabilities of the detector will be described and an overview of the first detected GRBs will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust quantum gates via a photon triggering electromagnetically induced transparency

We propose a scheme to achieve a parallelized controlled-NOT (c-not) gate based on electromagnetically induced transparency (EIT) and cavity-assisted photon scattering. By using the flying photon as the control bit, we can implement a conditional transfer between two logical states of an atom trapped in the cavity with high fidelity and on a microsecond time scale. Thanks to the fact that the photon is well suited for scalable quantum computation, a quantum c-not gate between the single-photon pulses and the nonlocal gate on remote atoms are obtained by reflecting the photon pulse from an optical cavity with a single-trapped atom. Our protocol is robust for spontaneous emission and works quite well in the bad-cavity limit, which makes it more applicable in the laboratory with current experimental techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An all-electronic fail-safe for stimulated Brillouin scattering suppression

The mitigation of transverse stimulated Brillouin scattering (SBS) via phase modulation is mandatory to avoid damage in high-energy laser systems. A novel fail-safe system that indirectly monitors the optical bandwidth applied to suppress SBS by monitoring the input, reflected, and through rf power of the SBS-suppression lithium-niobate phase modulator is demonstrated. The fail-safe system has high sensitivity and reliability provided by optimized redundant circuits for power monitoring and fail-safe decision logic. Calibration of the fail-safe’s thresholds is straightforward. Furthermore, the fail-safe circuitry reacts within 45 ns to stop an incorrectly modulated pulse by blocking the propagation of an electronic timing trigger.

fail-safe↗

Lightning tracking system

A system is described for locating lightning strikes by developing the coordinates of a pair of lines, each of which is produced at a reference sensing station. At each station there are a pair of directional antennas which produce analog signals responsive to a lightning stroke. These analog signals are fed to a pair of integrators which integrate the signals for a predetermined period of time so as to produce the X and Y coordinate of a particular line. The analog signals are also fed through a square rooter, a Schmitt trigger circuit, and flip-flops to produce pulses for starting and stopping the integrators. The system at the remote station is similar to that at the central station and is tied to the circuitry at the central station through logic circuits to minimize the chance of error from spurious signals. Computers, printers, and plotters are utilized to plot the exact location of the lightning stroke.

Wojtasinski, R. J.↗

Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗