Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Comparison of Several Methods of Measuring Ignition Lag in a Compression-ignition Engine

The ignition lag of a fuel oil in the combustion chamber of a high speed compression-ignition engine was measured by three different methods. The start of injection of the fuel as observed with a Stoborama was taken as the start of the period of ignition lag in all cases. The end of the period of ignition lag was determined by observation of the appearance of incandescence in the combustion chamber, by inspection of a pressure-time card for evidence of pressure rise, and by analysis of the indicator card for evidence of the combustion of a small but definite quantity of fuel. A comparison of the values for ignition lags obtained by these three methods indicates that the appearance of incandescence is later than other evidences of the start of combustion, that visual inspection of a pressure-time diagram gives consistent and usable values with a minimum requirement of time and/or apparatus, and that analysis of the indicator card is not worth while for ignition lag alone.

Spanogle, J A↗

Structural Fluctuations and Thermophysical Properties of Molten II-VI Compounds

The objectives of the project are to conduct ground-based experimental and theoretical research on the structural fluctuations and thermophysical properties of molten II-VI compounds to enhance the basic understanding of the existing flight experiments in microgravity materials science programs as well as to study the fundamental heterophase fluctuation phenomena in these melts by: 1) conducting neutron scattering analysis and measuring quantitatively the relevant thermophysical properties of the II-VI melts (such as viscosity, electrical conductivity, thermal diffusivity and density) as well as the relaxation characteristics of these properties to advance the understanding of the structural properties and the relaxation phenomena in these melts and 2) performing theoretical analyses on the melt systems to interpret the experimental results. All the facilities required for the experimental measurements have been procured, installed and tested. Thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range of 500 C to 900 C. The measured diffusivity as a function of temperature agrees fairly well with published data. However, a relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the melt, was observed for the first time. An apparatus based on the transient torque induced by a rotating magnetic field has been developed to determine the viscosity and electrical conductivity of semiconducting liquids. Viscosity measurements on molten tellurium showed a similar relaxation behavior to the measured diffusivity. The density and volume expansion coefficients for pure Te and HgTe melts were measured as a function of temperature using a pycnometric method. A density maximum was found for both melts but no relaxation behavior was observed. Neutron scattering experiments were performed on the HgTe and HgZnTe melts and the results on pair distribution showed better resolution than previously reported. A simple kinetic theory, which contains the formation reactions of Te polymerization that increases the molecular weight, was proposed to interpret the relaxation behavior of HgZnTe viscosity data.

Su, Ching-Hua↗

Structural Fluctuation and Thermophysical Properties of Molten II-VI Compounds

The objectives of the project is to conduct ground-based experimental and theoretical research on the structural fluctuations and thermophysical properties of molten II-VI compounds to enhance the basic understanding of the existing flight experiments in microgravity materials science programs and to study the fundamental heterophase fluctuations phenomena in these melts by: 1) Conducting neutron scattering analysis and measuring quantitatively the relevant thermophysical properties of the II-VI melts such as viscosity, electrical conductivity, thermal diffusivity and density as well as the relaxation characteristics of these properties to advance the understanding of the structural properties and the relaxation phenomena in these melts and 2) Performing theoretical analyses on the melt systems to interpret the experimental results. All the facilities required for the experimental measurements have been procured, installed and tested. A relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the sample, was observed for the first time. An apparatus based on the transient torque induced by a rotating magnetic field has been developed to determine the viscosity and electrical conductivity of semiconducting liquids. Viscosity measurements on molten tellurium showed similar relaxation behavior as the measured diffusivity. Neutron scattering experiments were performed on the HgTe and HgZnTe melts and the results on pair distribution showed better resolution than previous reported.

Source record↗

Microresonator and associated method for producing and controlling photonic signals with a photonic bandgap delay apparatus

By applying a photonic signal to a microresonator that includes a photonic bandgap delay apparatus having a photonic band edge transmission resonance at the frequency of the photonic signal, the microresonator imparts a predetermined delay to the photonic signal. The photonic bandgap delay apparatus also preferably has a photonic band edge transmission resonance bandwidth which is at least as wide as the bandwidth of the photonic signal such that a uniform delay is imparted over the entire bandwidth of the photonic signal. The microresonator also includes a microresonator cavity, typically defined by a pair of switchable mirrors, within which the photonic bandgap delay apparatus is disposed. By requiring the photonic signal to oscillate within the microresonator cavity so as to pass through the photonic bandgap delay apparatus several times, the microresonator can controllably impart an adjustable delay to the photonic signal.

Fork, Richard Lynn↗

NASA Tech Briefs, February 2001

The topics include: 1) Application Briefs; 2) National Design Engineering Show Preview; 3) Marketing Inventions to Increase Income; 4) A Personal-Computer-Based Physiological Training System; 5) Reconfigurable Arrays of Transistors for Evolvable Hardware; 6) Active Tactile Display Device for Reading by a Blind Person; 7) Program Automates Management of IBM VM Computer Systems; 8) System for Monitoring the Environment of a Spacecraft Launch; 9) Measurement of Stresses and Strains in Muscles and Tendons; 10) Optical Measurement of Temperatures in Muscles and Tendons; 11) Small Low-Temperature Thermometer With Nanokelvin Resolution; 12) Heterodyne Interferometer With Phase-Modulated Carrier; 13) Rechargeable Batteries Based on Intercalation in Graphite; 14) Signal Processor for Doppler Measurements in Icing Research; 15) Model Optimizes Drying of Wet Sheets; 16) High-Performance POSS-Modified Polymeric Composites; 17) Model Simulates Semi-Solid Material Processing; 18) Modular Cryogenic Insulation; 19) Passive Venting for Alleviating Helicopter Tail-Boom Loads; 20) Computer Program Predicts Rocket Noise; 21) Process for Polishing Bare Aluminum to High Optical Quality; 22) External Adhesive Pressure-Wall Patch; 23) Java Implementation of Information-Sharing Protocol; 24) Electronic Bulletin Board Publishes Schedules in Real Time; 25) Apparatus Would Extract Water From the Martian Atmosphere; 26) Review of Research on Supercritical vs Subcritical Fluids; 27) Hybrid Regenerative Water-Recycling System; 28) Study of Fusion-Driven Plasma Thruster With Magnetic Nozzle; 29) Liquid/Vapor-Hydrazine Thruster Would Produce Small Impulses; and 30) Thruster Based on Sublimation of Solid Hydrazine

Source record↗

Conversion and Extraction of Insoluble Organic Materials in Meteorites

We endeavor to develop and implement methods in our laboratory to convert and extract insoluble organic materials (IOM) from low car-bon bearing meteorites (such as ordinary chondrites) and Precambrian terrestrial rocks for the purpose of determining IOM structure and prebiotic chemistries preserved in these types of samples. The general scheme of converting and extracting IOM in samples is summarized in Figure 1. First, powdered samples are solvent extracted in a micro-Soxhlet apparatus multiple times using solvents ranging from non-polar to polar (hexane - non-polar, dichloromethane - non-polar to polar, methanol - polar protic, and acetonitrile - polar aprotic). Second, solid residue from solvent extractions is processed using strong acids, hydrochloric and hydrofluoric, to dissolve minerals and isolate IOM. Third, the isolated IOM is subjected to both thermal (pyrolysis) and chemical (oxidation) degradation to release compounds from the macromolecular material. Finally, products from oxidation and pyrolysis are analyzed by gas chromatography - mass spectrometry (GCMS). We are working toward an integrated method and analysis scheme that will allow us to determine prebiotic chemistries in ordinary chondrites and Precambrian terrestrial rocks. Powerful techniques that we are including are stepwise, flash, and gradual pyrolysis and ruthenium tetroxide oxidation. More details of the integrated scheme will be presented.

Locke, Darren R.↗

Methods and apparatus for calibration and response time testing of level sensors

Systems and methods of diagnosing performance of a level sensor of a fluid test chamber, including a data acquisition and processing unit configured to receive output signals of one or more level sensors that are installed to a fluid chamber, the data acquisition and processing unit being configured to connect to the one or more level sensors to record and process the output signals to test operation of the one or more level sensors.

Hashemian, Alexander Hashem↗

Method and Apparatus for the Collection Storage and Real Time Analysis of Blood and Other Bodily Fluids

The present invention provides an apparatus for separating a relatively large volume of blood into cellular and acellular fractions without the need for centrifugation. The apparatus comprises a housing divided by a fibrous filter into a blood sample collection chamber having a volume of at least about 1 milliliter and a serum sample collection chamber. The fibrous filter has a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein (or an animal or vegetable equivalent thereof). The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber.

Whitson, Peggy A.↗

First Measurements of High Frequency Cross-Spectra from a Pair of Large Michelson Interferometers

Measurements are reported of the cross-correlation of spectra of differential position signals from the Fermilab Holometer, a pair of colocated 39 m long, high power Michelson interferometers with flat broadband frequency response in the MHz range. The instrument obtains sensitivity to high frequency correlated signals far exceeding any previous measurement in a broad frequency band extending beyond the 3.8 MHz inverse light-crossing time of the apparatus. The dominant but uncorrelated shot noise is averaged down over 2×108 independent spectral measurements with 381 Hz frequency resolution to obtain 2.1×10-20m/Hz sensitivity to stationary signals. For signal bandwidths Δf>11 kHz, the sensitivity to strain h or shear power spectral density of classical or exotic origin surpasses a milestone PSDδh

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near real-time stereo vision system

The apparatus for a near real-time stereo vision system for use with a robotic vehicle is described. The system is comprised of two cameras mounted on three-axis rotation platforms, image-processing boards, a CPU, and specialized stereo vision algorithms. Bandpass-filtered image pyramids are computed, stereo matching is performed by least-squares correlation, and confidence ranges are estimated by means of Bayes' theorem. In particular, Laplacian image pyramids are built and disparity maps are produced from the 60 x 64 level of the pyramids at rates of up to 2 seconds per image pair. The first autonomous cross-country robotic traverses (of up to 100 meters) have been achieved using the stereo vision system of the present invention with all computing done onboard the vehicle. The overall approach disclosed herein provides a unifying paradigm for practical domain-independent stereo ranging.

Anderson, Charles H.↗

Method and Apparatus for the Collection, Storage, and Real Time Analysis of Blood and Other Bodily Fluids

The present invention provides a method and apparatus for separating a blood sample having a volume of up to about 20 milliliters into cellular and acellular fractions. The apparatus includes a housing divided by a fibrous filter into a blood sample collection chamber having a volume of at least about 1 milliliter and a serum sample collection chamber. The fibrous filter has a pore size of less than about 3 microns, and is coated with a mixture including between about 1-40 wt/vol % mannitol and between about 0.1-15 wt/vol % of plasma fraction protein (or an animal or vegetable equivalent thereof). The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber.

Whiitson, Peggy A.↗

Methods and Apparatus for Aggregation of Multiple Pulse Code Modulation Channels into a Signal Time Division Multiplexing Stream

Methods and apparatus are provided for telemetry processing using a telemetry processor. The telemetry processor can include a plurality of communications interfaces, a computer processor, and data storage. The telemetry processor can buffer sensor data by: receiving a frame of sensor data using a first communications interface and clock data using a second communications interface, receiving an end of frame signal using a third communications interface, and storing the received frame of sensor data in the data storage. After buffering the sensor data, the telemetry processor can generate an encapsulated data packet including a single encapsulated data packet header, the buffered sensor data, and identifiers identifying telemetry devices that provided the sensor data. A format of the encapsulated data packet can comply with a Consultative Committee for Space Data Systems (CCSDS) standard. The telemetry processor can send the encapsulated data packet using a fourth and a fifth communications interfaces.

Chang, Chen J.↗

Method and apparatus for the collection, storage, and real time analysis of blood and other bodily fluids

The present invention provides a simple, portable, relatively inexpensive apparatus for accurately and efficiently collecting, separating, testing, and even storing between about 1-20 ml, preferably about 1-10 ml, of blood or other bodily fluid in situ. The apparatus includes a collection chamber bounded on its sides by an opening in a sheet of material, preferably clear plastic, abutting a filter card. The filter card is made of fibrous material, preferably less than about a millimeter thick, having an average pore size of less than about 3 microns. Preferably, the fibers are glass and the fibrous material has an average pore size of about 1 micron. The fibrous material is treated with a carbohydrate/protein mixture which contains between about 1-40 percent wt/vol carbohydrate and about 0.1-15 percent wt/vol nonspecific protein, preferably between about 10-20 percent carbohydrate and about 5-8 percent protein. A preferred carbohydrate/protein mixture comprises about 10 percent mannitol and about 6 percent albumin. The blood or other fluid moves through the filter card by capillary action aided by an absorbent matrix with a high Klemm factor which abuts the filter card. The absorbent matrix and/or filter card can be treated with a wide spectrum of test reagents. The speed, cleanliness, and efficiency of the separation process can be altered by: (a) changing the absolute concentration of the carbohydrate/protein mixture; (b) applying positive or negative pressure to one side of the filter; and/or (c) varying the relative density and pore size of the filter card and absorbent matrix.

Whitson, Peggy A.↗

Sensing device and method for measuring emission time delay during irradiation of targeted samples

An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.

Danielson, J. D. Sheldon↗

Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers

Closed-cycle Joule-Thomson (JT) cryocoolers have been developed at National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) with the aim of realizing a liquid-helium-free calibration apparatus for cryogenic thermometers between 0.65 K and 25 K. The latest JT cryocooler at NMIJ/AIST consists of a {sup 3}He JT cooling circuit and a pulse tube mechanical refrigerator. The characteristics of the apparatus including a residual gas analysis of the JT cooling circuit are presented in this paper. Currently the initial cool-down is performed using a heat-exchange gas. It normally takes about 30 h to reduce the temperature from room temperature to 5 K at the thermometer comparison block of the apparatus. The correct timing of the removal of the heatexchange gas is important for the efficient operation of the apparatus. Incomplete removal of the heat-exchange gas induces excess heat load on the apparatus and thermal disturbances. Some examples of abrupt temperature bursts are discussed in this paper. Mechanical refrigerators generate cyclic mechanical vibrations, and precision resistance thermometers are usually very sensitive to a mechanical vibration. The measured vibration level of the developed apparatus is reported. The damage to the apparatus due to the magnitude 9.0 earthquake on March 11, 2011, and possible countermeasures in the case of future earthquakes are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for granting processors access to a resource

An apparatus and method for granting one or more requesting entities access to a resource in a predetermined time interval. The apparatus includes a first circuit receiving one or more request signals, and implementing logic for assigning a priority to the one or more request signals, and, generating a set of first_request signals based on the priorities assigned. One or more priority select circuits for receiving the set of first_request signals and generating corresponding one or more fixed grant signals representing one or more highest priority request signals when asserted during the predetermined time interval. A second circuit device receives the one or more fixed grant signals generates one or more grant signals associated with one or more highest priority request signals assigned, the grant signals for enabling one or more respective requesting entities access to the resource in the predetermined time interval, wherein the priority assigned to the one or more request signals changes each successive predetermined time interval. In one embodiment, the assigned priority is based on a numerical pattern, the first circuit changing the numerical pattern with respect to the first_request signals generated at each successive predetermined time interval.

Blumrich, Matthias A↗

Focusing properties of near-field time reversal

A time-reversal mirror (TRM) is a plane apparatus that generates the time symmetric of a wave produced by an initial source. Here we look for the conditions to obtain subwavelength focusing when the initial source is in the near field of the TRM and the propagating medium is homogeneous and isotropic. Three variants of TRM are studied: TRM made of monopoles, dipoles, or both of them. The analysis is performed in terms of evanescent and propagative waves. We conclude that only the dipole-TRM leads to subwavelength focusing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗